Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.7 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹43.3 L+₹7.6 L (21.1%)Rejected-Finance INDEX NO E 29 CWE JRC 352 3 GURU NANAK PURA EAST JALANDHAR CITY PIN 144001 | JALANDHAR CITY | JALANDHAR | PUNJAB | 144001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹47.3 L+₹11.5 L (32.3%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
20 Sept 2022, 6:00 pmClosed
Garrison Engineer (East) Jalandhar Cantt
Garrison Engineer (East) Jalandhar Cantt
REPAIR/ MAINT OF CERTAIN INTERNAL, EXTERNAL ELECTRIC SERVICES, WATER SUPPLY SERVICES, AUMMER APPLIANCES AND OTHER MISC E/M NATURE WORK OF J-1 AND J-2 LOC UNDER GE (EAST) JALANDHAR CANTT
2022_MES_547122_1
GE/JULL/ET-52/2022-23
Open Tender
Civil Works
Item Rate
273 days
Jalandhar Cantt
As per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jalandhar Cantt
₹95,000
Yes
20 Oct 2022
23 Aug 2022
27 Sept 2022
23 Aug 2022
20 Sept 2022
8 Sept 2022
Amount
Taking down carefully existing point wiring of any type (i.e. on wooden batten, surface conduit, casing capping or concealed conduit) complete for light, fan socket or power point with fitting Supply and fixing fixtures such as ceiling rose, electric fittings, holders, switches, sockets wooden batten, conduit etc including accessories such as wooden gutties/ rawl plug, screw etc including removing materials from site and making good disturbed surface of walls, floors etc. complete all as specified and directed
Material and labour for point wiring with 1.5 sqmm (nominal area), 1100 volt grade PVC insulated FRLS type multi stranded copper conductor cable drawn in and including concealed rigid PVC conduit medium grade ISI marked with accessories including cutting chases for laying of conduit/ fixing of boxes in walls/ floors etc including making good to disturbed surfaces as per adjoining specification and terminated in concealed terminal boxes including MS concealed terminal boxes with plastic laminated bakelite sheet top cover 3mm thick make hylum or equivalent fixed with nickel polished screws with washers and earth continuity PVC insulated FRLS type cable with stranded copper conductor of size 1.5 sqmm (nominal area) green colour as earth wire connected with earth dolly for one light point controlled one switch complete all as specified and as directed.
All as per Srl Item No. 2.00 but one fan point controlled by one switch
All as per Srl Item No. 2.00 but for 3 pin 5 Amp socket point controlled by one switch on independent board.
All as per Srl Item No. 2.00 but one socket point controlled by one the same board 3 pin 5 Amp with other switch
All as per Srl Item No. 2.00 but 3 pin 15 Amp socket outlet with 2.5 sqmm PVC insulated FRLS copper cable and 2.5 sqmm PVC insulated FRLS copper cable for continuous earth continuity conductor all as specified and directed.
Supply and fixing in replacement switch modular type, 6 Amps, 240 volt AC single pole, one way including taking down existing switch complete all as specified.
Supply and fixing in replacement switch modular type, 15 Amps, 240 volt AC single pole, one way including taking down existing switch complete all as specified.
Supply and fixing socket outlet 6/10 Amp, 5 pin modular type including taking down existing socket complete all as specified.
Supply and fixing socket outlet multipurpose 3 in 1, 6 pin, 6/16 Amps, modular type including taking down existing socket complete all as specified.
Supply and fixing modular bell push button complete all as specified.
Supply and fixing blanking strips (dummy) 1 module for modular switch board complete all as specified
Material and labour in replacement of submain wiring with two single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 4.0 sqmm 1100 volts grade including and 4.0 sqmm PVC insulated, multi stranded, unsheathed copper wire green in colour as earthing lead drawn through in existing PVC/ steel rigid conduit complete all as specified. Make: Two run of 4.0 sqmm cable and one run of 4.0 sqmm cable as earth continuity conductor shall be measured & paid as one unit
Material and labour in replacement of submain wiring with two single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 6.0 sqmm 1100 volts grade including and 6.0 sqmm PVC insulated, multi stranded, unsheathed copper wire green in colour as earthing lead drawn through in existing PVC/ steel rigid conduit complete all as specified. Make: Two run of 6.0 sqmm cable and one run of 6.0 sqmm cable as earth continuity conductor shall be measured & paid as one unit
Material and labour in replacement of submain wiring with two single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 10.0 sqmm 1100 volts grade including and 10.0 sqmm PVC insulated, multi stranded, unsheathed copper wire green in colour as earthing lead drawn through in existing PVC/ steel rigid conduit complete all as specified. Make: Two run of 10.0 sqmm cable and one run of 10.0 sqmm cable as earth continuity conductor shall be measured & paid as one unit
Supply and fixing in repair aesthetically designed linear mirror light 14 watt with provided with high output PMMA diffuser for glare free light, dimension 600mm including taking down old one with all accessories and making good the existing disturb surface complete all as specified and directed.
Supply and fixing decorative wall light fixture made up of polycarbonate, suitable for lamp type 9 watt retrofit LED lamp including 9 watt LED lamp (B-22 base) of same make as fitting including removing old fitting complete all as specified
Supply and fixing square surface mounted ACE LED SURFACE DOWNLIGHTER of 16 watt 6500K of size 155mm x 155mm having surface mounting convertible feature including RING to convert recess into surface complete all as specified and directed
Supply and fixing surface mounting energy saving LED tube light fitting, T8 (4 ft), 1 x 18 W, 6500 K, 2100 lumen, 230 V, ultra bright, glass shell, glare free, white light, wide angle, double side connection retrofit with G 13 lamp holders with inbuilt driver including pre-coated CRCA covered batten, box type, prewired including removing old fitting complete all as specified and directed.
Supply and fixing energy saving surface mounting bulk head luminaire with polycarbonate diffuser LED integral fitting 10 watt (min), IP-54, complete all as specified and directed.
Supply and fixing in replacement of ball bearing 6201 of ceiling fan complete including testing of fans complete all as specified and directed.
Supply and fixing in replacement of ball bearing 6202 of ceiling fan complete including testing of fans complete all as specified and directed.
Supply and fixing in replacement of gun metal bush of suitable size for ceiling fan complete all as specified
Supply and fixing in replacement capacitor 2.5 MFD complete all as specified and directed.
Material and labour for rewinding of ceiling fan motor 240 volt, 50 Hz, 1400 mm sweep, any make, with super enameled copper winding wire of existing size, same No. of turns, wound with machine, providing insulation material of E-grading, varnishing, connection with flexible copper wire 3 core upto connector block complete all as specified and directed.
Material and labour for rewinding of ceiling fan motor 240 volt, 50 Hz, 1200 mm sweep, any make, with super enameled copper winding wire of existing size, same No. of turns, wound with machine, providing insulation material of E-grading, varnishing, connection with flexible copper wire 0.472mm dia upto connector block complete all as specified and directed.
Material and labour for rewinding of exhaust fan motor 240 volt, 50 Hz, 300 mm sweep, any make, with super enameled copper winding wire of existing size, same No. of turns, wound with machine, providing insulation material of E-grading, varnishing, connection with flexible copper wire 3 core upto connector block complete all as specified and directed.
Material and labour for rewinding of exhaust fan motor 240 volt, 50 Hz, 450 mm sweep, any make, with super enameled copper winding wire of existing size, same No. of turns, wound with machine, providing insulation material of E-grading, varnishing, connection with flexible copper wire 3 core upto connector block complete all as specified and directed.
Taking down ceiling fans, any make and size, removing electrical connection, dismantling blades etc, opening of motor, cleaning of fan body and blades using detergent, greasing and oiling of serviceable ball bearing, bushes, replacement of defective/ unserviceable ball bearing and other parts, reassembling motor and fan, testing and hanging in position complete all as specified and directed. Make: Spare parts shall be measured & paid separately.
Taking down exhaust fans, any make and size, removing electrical connection, dismantling blades etc, opening of motor, cleaning of fan body and blades using detergent, greasing and oiling of serviceable ball bearing, bushes, replacement of defective/ unserviceable ball bearing and other parts, reassembling motor and fan, testing and hanging in position complete all as specified and directed. Make: Spare parts shall be measured & paid separately.
Supply and fixing apparatus assembly complete with incoming/ outgoing brass pipe complete with gasket, nuts, bolts, washers as required for make of Bajaj Shakti water heater of capacity 15 ltr capacity complete all as specified and directed.
Supply and fixing apparatus assembly complete with incoming/ outgoing brass pipe complete with gasket, nuts, bolts, washers as required for make of Bajaj Shakti water heater of capacity 25/ 35 ltr capacity complete all as specified and directed.
Supply and fixing in repair heating element 1500 watt complete matching to existing size and shape all as specified and directed.
Supply and fixing in replacement thermostat for geyser of capacity 35 Ltr/ 25 Ltr/ 15 Ltr complete all as specified and directed.
Supply and fixing in replacement PVC connection hot and cold water pipe 18" long, 15mm outer dia with brass nut and washer, both side complete all as specified and directed.
Supply and fixing B22 LED bulb 9 watt, 230V, with lm/w not less than 105, 6500K complete all as specified and directed
Supply and fixing door metallic sheet metal enclosure for DB when MCBs to be used V-TPN 4 ways, 415V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables, wires all as directed.
Supply and fixing MCB SPN 40 Amps to 63 Amp, 240V, 50Hz, 10 KA complete all as specified and directed.
Supply and fixing MCB SPN 32 Amps, 240V, 50Hz, 10 KA complete all as specified and directed.
Supply and fixing MCB SP 6 Amps to 32 Amp, 240V, 50Hz, 10 KA complete all as specified and directed.
Supply and fixing sheet metal enclosure DBs when MCBs to be used, SPN 8 ways 240 V, with 2500 Amp copper bus bar, double door, epoxy powder coated inside and outside with earth bar and neutral bar, prewired complete all as specified.
Supply and fixing modular white cover plate assy complete matching to existing shape and size of 2 module all as specified and directed.
Supply and fixing modular white cover plate assy complete matching to existing shape and size of 3 module all as specified and directed.
Supply and fixing modular white cover plate assy complete matching to existing shape and size of 6 module all as specified and directed.
Supply and fixing modular white cover plate assy complete matching to existing shape and size of 8 module all as specified and directed.
Supply and fixing modular white cover plate assy complete matching to existing shape and size of 12 module all as specified and directed.
Supply and fixing sunken sheet metal box 2 module suitable for modular fittings matching to existing cover plate complete all as specified and directed.
Supply and fixing sunken sheet metal box 3 module suitable for modular fittings matching to existing cover plate complete all as specified and directed.
Supply and fixing sunken sheet metal box 6 module suitable for modular fittings matching to existing cover plate complete all as specified and directed.
Supply and fixing sunken sheet metal box 8 module suitable for modular fittings matching to existing cover plate complete all as specified and directed.
Supply and fixing sunken sheet metal box 12 module suitable for modular fittings matching to existing cover plate complete all as specified and directed.
Supply and fixing in repair switch piano flush type, 5 Amps, 240 Volt AC single pole, one way complete all as specified.
Supply and fixing in repair switch piano flush type, 15 Amps, 240 Volt AC single pole, one way complete all as specified.
Supply and fixing in repair socket out let 5 Amp, 5 pin flush type, 240V complete all as specified.
Supply and fixing in repair socket out let 15 Amp, 3 pin flush type, 240V complete all as specified.
Supply and fixing in repair bell electric AC (Ding Dong) 240 volts SP complete all as specified and directed.
Supply and fixing in repair bell push switch flush type 5 Amps, SP, 240 volts complete all as specified and directed.
Supply and fixing in repair ceiling rose surface type bakelite 65 x 50mm three terminal complete all as specified and directed.
Supply and fixing in repair batten holder ISI marked insulated body complete all as specified.
Supply and fixing in replacement GI pipe light grade ISI marked of size 100mm bore for cable protection including provision of PVC heavy duty bends complete for fixing along road/ floor along the pole including fittings complete all as specified.
All as per Srl Item No. 60.00 but 80mm dia bore
All as per Srl Item No. 60.00 but 50mm dia bore
Supplying, laying, jointing and testing in replacement underground XLPE insulated, armoured heavy duty electric cable insulated and PVC sheathed LT 1100 volt grade (heavy duty) with standard aluminum conductor of size 6 Sqmm 2 core laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and directed.
All as per Srl Item No. 63.00 but size 10 sqmm 2 core
All as per Srl Item No. 63.00 but size 16 sqmm 4 core
All as per Srl Item No. 63.00 but size 25 sqmm 3½ core
All as per Srl Item No. 63.00 but size 50 sqmm 3½ core
All as per Srl Item No. 63.00 but size 70 sqmm 3½ core
All as per Srl Item No. 63.00 but size 95 sqmm 3½ core
All as per Srl Item No. 63.00 but size 185 sqmm 3½ core
Excavation in trenches in soft/ loose soil n. exc. 1.50 mtr wide and n. exc. 1.50 mtr in depth for laying of cables/ CI/ GI/ DI pipe lines and getting out complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick each layer complete all as specified and directed.
Removal of surplus spoil to a distance n. exc. 50 mtr and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for sand cushioning with 8cm thick layer before laying of cable and 15cm thick layer after laying of cable in trenches complete all as specified and directed.
Material and labour for old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, abutting each other complete all as specified and directed.
Re-laying retrieved bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/ abutting each other complete all as specified and directed.
Supply and fixing earthing complete for with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of the plate at a depth not less than 1.50 metre below normal ground level, connected with and including GI strip 32mm x 6mm in and including GI pipe 40mm bore light grade as protection pipe (from top of earth plate up to the test point) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick, all around including top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh, PCC chamber of size 300x300x300mm(top of chamber minimum 15 cm above the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-I using 20mm graded crushed stone aggregate of 25mm thick with 1 Nos MS handles of 8mm dia including necessary excavation/ earth work in any type of soil/rock and as shown in Electrical plate No. 3 of SSR Part-I (2009) testing on completion complete all as specified. Note: If result is not achieved satisfactory, contractor will have to do re-earthing at his own cost. Nothing shall be paid extra on this account
All as per Srl Item No. 77.00 above but GI wire 4mm dia
Material and labour for scraping old paint from LT panels/ feeder pillars inner & outside off size with emery paper, preparing old surface for painting, applying two coats of synthetic enamel paint in steel grey/ blue from top of PCC coping and marking number/ name of panel and feeders in alphabets not less than 50mm in size complete all as specified and directed
Material and labour preparation of old painted surface of steel tubular poles straight/ swan neck and applying two coats of synthetic enamel paint in alternate black & white strips of 30cm each upto 1.5 mtr height from top of PCC coping and two coats of aluminium paint to remaining part of poles above strips including painting of street light brackets, clamps and numbering the pole of height 7/9 mtrs complete all as specified and directed. Note : Colour for base of board and alphabets shall be decided by Engineer-in-Charge
Supply and fixing in replacement oval shaped post top lantern in prismatic finish made up of polycarbonate material suitable and including 10 W retrofit LED lamp (B-22 Base) all as specified and directed.
Material and labour for replacing MCCB 400 Amps, 4 pole with adjustable thermal magnetic release, 35 KA, ICS=ICS=100% complete all as specified and directed.
Material and labour for replacing MCCB 250 Amps, 4 pole with adjustable thermal magnetic release, 25 KA, ICS=ICS=100% complete all as specified.
Material and labour for replacing MCCB 200 Amps, 4 pole with adjustable thermal magnetic release, 25 KA, ICS=ICS=100% complete all as specified
Material and labour for replacing MCCB 160 Amps, 4 pole with adjustable thermal magnetic release, 25 KA, ICS=ICS=100% complete all as specified
Material and labour for replacing MCCB 100 Amps, 4 pole with adjustable thermal magnetic release, 25 KA, ICS=ICS=100% complete all as specified
Material and labour for replacing MCCB 63 Amps, 4 pole with adjustable thermal magnetic release, 16 KA, ICS=ICS=100% complete all as specified
Supply and fixing in replacement CVCC type, BIS marked electronic driver duly enclosed potted LED driver having protection against over voltage, short circuit and open circuit, voltage band 100 volts to 270 volts, power factor 0.90 suitable for LED street light/ flood light of capacity 45W having SPD 4KV (min)complete all as specified and directed.
Supply and fixing in replacement CVCC type, BIS marked electronic driver duly enclosed potted LED driver having protection against over voltage, short circuit and open circuit, voltage band 100 volts to 270 volts, power factor 0.95 suitable for LED street light/ flood light of capacity 60W having SPD 4KV (min) complete all as specified and directed.
Supply and fixing in replacement CVCC type, BIS marked electronic driver duly enclosed potted LED driver having protection against over voltage, short circuit and open circuit, voltage band 100 volts to 270 volts, efficacy > 110 lm/W, power factor 0.95 suitable for LED street light/ flood light of capacity 90W to 150W complete all as specified and directed. Note : The contractor shall have to procure the suitable driver for existing LED light fittings
Supply and fixing in replacement CVCC type, BIS marked electronic driver duly enclosed potted LED driver having protection against over voltage, short circuit and open circuit, voltage band 100 volts to 270 volts, efficacy > 110 lm/W, power factor 0.95 suitable for LED street light/ flood light of capacity 180W to 200W complete all as specified and directed. Note : The contractor shall have to procure the suitable driver for existing LED light fittings
Supply and fixing SPD (Surge Protection Device) suitable for LED street light/ flood light fitting 45W to avoid surge protection voltage upto 5KV complete all as specified and directed
Supply and fixing SPD (Surge Protection Device) suitable for LED street light/ flood light fitting to avoid surge protection voltage upto 10KV (min) complete all as specified and directed
Repair/ rectification for 12.5m high mast lights/ 16m high mast light including bringing down of high mast light bracket down to ground level, dismantling/ repair the lights after replacement of parts, assembling/ re-fixing the lights and taking up the light bracket complete with the help of motor or any type of manual labour work including any disconnection/ connection of cable involved complete all as specified and directed. Note : The taking down of high mast light down, repair of one or more lights and taking up and fixing the bracket on top at one time will be measured as one unit for payment
Material and labour for replacing TPN MCB, 32 Amp having rupturing capacity 10 KA, 240V, 50Hz complete all as specified.
Material and labour for replacing TPN MCB, 40 Amp having rupturing capacity 10 KA, 240V, 50Hz complete all as specified.
Dehydration and filtration of existing transformer oil using transformer oil filtration cum dehydration plant to eliminate foreign particles and to improve di-electric strength upto 45 KV (min) in 2.5mm electrode gap and to bring the acidity within the permissible limit below 0.5 mg KOH/ Cm complete all as specified and directed. Record of di-electric strength of insulating oil achieved after dehydration shall be given in writing by the contractor to the dept.
Supply & filling transformer insulation oil conforming to IS-335 for topping up the level of oil having di-electric strength 45-60 KV (minimum) at a electrode gap of 2.5mm upto the required level of transformer and testing of di-electric strength of oil in transformer before and after filling. Make: POWER/ SERVO/ INSOLE/ UNIVERSAL/ SAVITA/ CASTROL conforming to relevant IS-335. Note:- Transformer oil be supplied in sealed containers.
Supply and fixing filling of fresh and dry Silica gel inside the breather pocket and fixing properly with transformer 400 KVA including painting the outer surface of the breather assembly including taking out silica gel complete all as specified.
Material and labour for detecting leakage from transformer complete by removing HT & LT supply connections, decanning oil for reuse, opening top cover, removing, scraping of old worn out gasket of oil tank and fixing of new cork gasket sheet on the tank top cover 6.0mm thick and pasted by using suitable adhesive for the transformer of any type/ make of capacity 50 to 160 KVA including re-filling oil after heating & dehydration, making necesary electric connections and testing complete on site in existing position (at plinth/ in CSS/ at pole structure) complete all as specified
Material and labour for replacement of copper cable for connection in LT panels for metering and CTs of size 4 sqmm FRLS single core duly crimped with copper thimbles and crimping complete all as specified and directed. Note : Cost of copper thimbles and crimping included
Supply and fixing LED flood light fitting 150 watts, made up of pressure die-cast aluminium housing with toughened clear glass with mandatory secondary optics individual lenses, with SS screws, IP-66, luminaire efficacy more than 120Lm/W, CCT 5700K ANSI, CRI>70, THD<10%, PF>0.95, LED source : Hi power LED 3 to 5W, having potted constant current driver moisture resistant with internal surge protection 4 KV having under voltage, over voltage, phase to phase protection and short circuit protection and auto recovery mode, operating range 150V to 270V AC at 50 Hz, auto cut off >300V and with separate surge protection device 10KV complete having fixing bracket clamp and connection cable all as specified and directed Notes : (a) All LED fitting shall be made in India and of standard size only. (b) All LED fittings shall have supporting LM-79 & LM-80 test certificate from Govt approved NABL accredited Lab showing all the parameters duly signed by the local office bearer of manufacturer. (c) All LED fittings shall have 2 years written warranty from local office bearer of manufacturer. (d) The old unserviceable LED fitting shall be issued by JE in-charge after deducting amount as per Sch of Credit at the time of RAR (e) The old unserviceable light fitting may be of lower wattage/ old specification, no claim will be entertained on this account.
All as per srl item No. 102.00 here-in-before but 100 watts
Supply and fixing LED street light fitting 60 watts, made up of pressure die-cast aluminium housing with clear glass with mandatory secondary optics individual lenses, with SS screws, IP-66, luminaire efficacy more than 110Lm/W, CCT 5700K ANSI, CRI>70, THD<10%, PF>0.95, LED source : Hi power LED 3 to 5W, having external potted constant current driver moisture resistant (installed in separate independent compartment) with internal surge protection 4 KV having under voltage, over voltage, phase to phase protection and short circuit protection and auto recovery mode, operating range 150V to 270V AC at 50 Hz, auto cut off >300V and with separate external surge protection device 10KV suitable for fitting on 32/40mm dia bore pipe bracket including making connections with PVC insulated 3 core copper conductor cable 0.75 Sqmm min of suitable length complete all as specified and directed Notes : (a) All LED fitting shall be made in India and of standard size only. (b) All LED fittings shall have supporting LM-79 & LM-80 test certificate from Govt approved NABL accredited Lab showing all the parameters duly signed by the local office bearer of manufacturer. (c) All LED fittings shall have 2 years written warranty from local office bearer of manufacturer. (d) The old unserviceable LED fitting shall be issued by JE in-charge after deducting amount as per Sch of Credit at the time of RAR (e) The old unserviceable light fitting may be of lower wattage/ old specification, no claim will be entertained on this account.
All as per srl item No. 104.00 here-in-before but 45 watts
Supply and fixing in replacement bracket made out of 25mm dia light grade GI tubing 1.2 metre long and bent to shape at 120° angle with required holes for passing connection cable, fixed with clamps nuts and bolts, washer complete all as specified. (Clamps, nut, bolts and washers will be measured and paid separately).
Supply and fixing in replacement bracket made out of 32mm dia light grade GI tubing 1.2 metre long and bent to shape at 120° angle with required holes for passing connection cable, fixed with clamps nuts and bolts, washer complete all as specified. (Clamps, nut, bolts and washers will be measured and paid separately).
Supply and fixing cable jointing kit suitable for XLPE insulated, screened, armoured aluminium cable of size 95 Sqmm to 185 Sqmm, 3 Core, 11 KV grade earthed cable for indoor type termination cold shrinkable joint complete with jointing material and accessories including opening cable connections/ taking down, taking old unserviceable jointing kit and re-fixing cable complete all as specified and directed
Material and labour for locating & pinpointing conductor and insulation faults of low and high resistance, intermittent or flashing nature in XLPE HT/ LT underground power cables of the rating 11/1.1 KV with the help of pre-locator with time domain laptop based reflectometer/ electrometer using pulse echo method, impulse current method & decay method and using DC high voltage surge generator to produce surge to trace route and pinpointing fault with the help of dual channel digital sound system, magnetic & acoustic for location of fault with acoustic transducer (pickup) and the amplifier with headphones, after pinpointing of fault location necessary excavation and taking out of faulty cable for repair/ replacement and insertion of straight through joints, relaying of cable, refilling of soil and removal of surplus soils etc, at J-1 & J-2 Loc complete all as specified and directed Notes : (i) The joint shall be measured and paid separately under relevant item. (ii) The qty of item will be executed at different times during currency of contract as directed by Engineer-in-Charge. (iii) Contractor shall quote his rate accordingly for arranging and executing the items accordingly
Supply and fixing heat shrinkable straight through joint suitable for 1100 V, XLPE/ PVC cable for size 95 Sqmm to 150 Sqmm 3½ Core including disconnecting and connecting cable complete all as specified and directed
Supply and fixing heat shrinkable straight through joint suitable for 1100 V, XLPE/ PVC cable for size 185 Sqmm to 240 Sqmm 3½ Core including disconnecting and connecting cable complete all as specified and directed
Supply and fixing end termination heat shrinkable joint suitable for 1100 V, XLPE/ PVC cable for size 35 Sqmm to 70 Sqmm 3½ Core including disconnecting and connecting cable complete all as specified and directed
Supply and fixing in replacement cable jointing kit suitable for XLPE armoured aluminium cable of size 95 to 185 sqmm 3½ core 1.1 KV grade cable for straight through type termination heat shrinkable joint complete with jointing material and accessories incl necessary excavation and civil work reqd at site complete all as specified and directed
Supply and fixing cable jointing kit suitable for XLPE armoured aluminium cable of size 95 Sqmm to 185 Sqmm, 3 Core, 11 KV grade cable for outdoor type termination cold shrinkable joint complete with jointing material and accessories complete all as specified and directed
Supply and fixing in replacement All-in-One solar light complete LED light 15 watt complete with SPV panel, lift battery complete all as specified and directed Make : HPL/ Havells/ Crompton/ Bajaj
Material and labour for Boring hole under the road/ pavement/ hard standing with the help of trenchless technology using ultra sound technique and necessary machine for inserting GI pipe upto 150mm at a depth not less than one metre below ground level complete all as specified & directed. Note: GI pipe shall be included and paid in quoted rate
Material and labour painting of water treatment plant pipe line and induction motor of following sizes including scraping of old paint from GI pipe and induction motor with emery paper, preparing old surface for painting, apply two coats of synthetic enamel paint in steel grey by using spray gun complete all as specified and directed :- (a) 50mm dia - 35 RM. (b) 80mm dia - 30 RM. (c) 100mm dia - 45 RM. (d) 200mm dia - 40 RM. (e) Induction motor-07 Nos
Material and labour scraping old paint from water filter at water treatment plant size 1600mm dia with emery paper, preparing old surface for painting and apply two coats of synthetic enamel paint in steel grey shade by using spray gun complete all as specified and directed.
Material and labour painting of sewage treatment plant pipe line and induction motor of following sizes including scraping of old paint from GI pipe and induction motor with emery paper, preparing old surface for painting, apply two coats of synthetic enamel paint in steel grey by using spray gun complete all as specified and directed :- (a) 50mm dia - 55 RM. (b) 80mm dia - 50 RM. (c) Air blower motor-02 Nos (d) Raw sewage trust pump-02 Nos (e) Sludge pump-02 Nos (f) Filter pump-02 Nos (g) Press filter-01 No (h) Irrigation pump-02 Nos
Material and labour scraping old paint from dual media filter and activated carbon filter at STP size 1200mm dia with emery paper, preparing old surface for painting, apply two coats of synthetic enamel paint in steel grey shade by using spray gun complete all as specified and directed.
Material and labour scraping old paint from fire hydrant of height 2 mtr and GI pipe at fire fighting plant with emery paper, preparing old surface for painting, apply two coats of synthetic enamel paint in steel grey shade by using spray gun complete all as specified and directed. (a) 200mm dia-25 RM (b) 150mm dia-20 RM (c) Fire hydrant of height 2 mtr and 80mm dia-09 Nos
Supply and fixing in replacement sluice valve, flanged of class 1.6 PN of size 100mm dia with iron hand wheel complete with nuts, bolts and gasket all as specified and directed. Make: Zoloto/ BIR/ KARTAR/ Kirlosker
Supply and fixing in replacement sluice valve, flanged of class 1.6 PN of size 150mm dia with iron hand wheel complete with nuts, bolts and gasket all as specified and directed. Make: Zoloto/ BIR/ KARTAR/ Kirlosker
Supply and fixing in replacement butterfly valve of size 80mm dia complete all as specified and directed Make: Zoloto/ BIR/ KARTAR/ Kirlosker
Supply and fixing in replacement pressure gauge 4" dia 0 to 14 Kg/cm2 complete all as specified and directed Make: Advance/ Castle/ NVR/ Minar/ G Luck India
Supply and fixing in replacement 40mm gun metal globe or gate valve, with iron wheel head screwed both ends for iron pipe and fixed complete all as specified
All as per Srl Item No. 127.00 but 15mm
Supply and fixing GI tubing medium grade 50mm bore (in any length) with required fitting duly laid in trenches and connecting up with water supply mains including removing unserviceable tubing complete all as specified
All as per Srl Item No. 129.00 but size 40mm dia
All as per Srl Item No. 129.00 but size 25mm dia
All as per Srl Item No. 129.00 but size 15mm dia
Material and labour for disconnecting electric connection, pipe connection and taking out submersible pump & motor of capacity 7.5 HP from bore well/ sump and taking to workshop for repair and removal of burnt winding wire from motor and rewinding with new PVC insulated copper winding wire for submersible motor of same gauge and weight to existing including replacement of motor bush, thrust plate coupling complete with key and reassembling the motor and lowering it into bore well making it functional and testing complete all as specified
Material and labour for taking defective motor to workshop for repair and removal of burnt winding wire from motor and rewinding with new copper winding wire for submersible motor of same gauge and weight to existing including replacement of motor bush, thrust plate coupling complete with key and bringing back to site and testing complete all as specified and directed
Material and labour disconnecting submersible pump from electric motor of capacity 7.5 HP and taking to workshop for repair and replacement of unserviceable part such as gun metal, bush impeller, assembly shaft, locking key and MS nuts & bolts of existing size and reassembling the pump with motor and making it functional condition testing the pump to the entire satisfaction of Engineer-in-Charge.
Supply and fixing lowering PVC insulated & PVC sheathed industrial 4 Sqmm 3 core flat submersible cables with bare bunched copper conductor for submersible pump motors with voltage grade 1100 volts generally conforming to IS 694/1990 complete all as specified and directed.
Dismantling of unserviceable induction electric motor for rewinding with same gauge of the original specification and re-fixing, re-aligning in original position the same after winding for smooth operation of motor of capacity 1 HP to 7.5 HP complete all as specified and directed .
Dismantling of unserviceable induction electric motor for rewinding with same gauge of the original specification and re-fixing, re-aligning in original position the same after winding for smooth operation of motor of capacity 10 HP to 20 HP complete all as specified and directed .
Material and labour for replacing MCB TP, 63 Amp having rupturing capacity 10 KA, complete all as specified Make: L&T/ Crompton Greaves/ Havells
Material and labour in replacement ball valve brass high pressure with polythene float and fly nut complete screwed for 15mm bore dia of iron pipe or brass ferrule and fixed complete all as specified
Supply and fixing PVC connection 15mm bore size with PTMT nuts of length 450mm complete all as specified and directed.
Material and labour for dewatering and de-sludging dry or wet of sludge by sucking machine taking out removal, transportation and depositing the same outside the MoD are upto a 20 Km distance (Maximum) as specified by Civil Authority including cleaning by deploying manpower with full safety equipments as applicable repairing if required as per existing specification with using JPCE solution suitable for bacteria growth all as specified and directed after restart and commissioning of plant complete and testing of functioning all appliances, collection of treated water sample and testing of same from Govt approved laboratory and repair if required any to achieve results as per permissible limit :- (a) Equalisation tank sizes 7.5 mtr x 8 mtr x 5 mtr – 01 No (b) Oil and grease trap size 5.7 mtr x 1.5 mtr x 3 mtr – 01 No (c) Sludge holding tank sizes 5 mtr x 3 mtr x 4 mtr – 01 No (d) Aeriation tank sizes 8 mtr x 5 mtr x 4 mtr -02 Nos Note : The sucking of sewage/ sludge and removal from site and dumping one time & to and for one trip will be measured as one unit for payment.
Material and labour for JPCE-1 solution suitable for bacteria growth complete all as specified and directed
Labour charge for cleaning of equalization tank, oil grease trap, aeration tanks and sludge holding tank by using sucking machine and manually complete all as specified and directed
Material and labour in replacement of fan belt for air blower No. 2120 complete all as specified and directed Make : Beltex/ Fennel/ Dunlop
Material and labour in replacement of fan belt for filter press No. A1350/A52 complete all as specified and directed Make : Beltex/ Fennel/ Dunlop
Material and labour in replacement of gear oil upto the required level in air blower motors complete all as specified and directed
Supply & use Calcium hypo-chloride liquid based high strength, dry free flowing having available chlorine 65% min, stability 1/15, water insoluble matter 6% max suitable to water disinfection complete all as specified and directed by Engineer-in-Charge.
Material and labour for servicing and maintenance of inner & outer unit of split type AC of capacity 1.5/ 2 TR of any make by cleaning for of condenser coil & evaporator coil with acid and washing of air filter, oiling and tightening of all nut, bolts etc. complete all as directed.
Servicing and overhauling of duct AC of (2 x 8.5 TR) by washing of coils with C-shine chemical indoor and outdoor unit checking up of electrical connections/ controls etc complete all as specified and directed.
Material and labour for detection of leakage in the system of AC plant package type of capacity 2 x 17 TR working capacity + 1 x 17 TR standby by charging CO2 gas maintaining pressure 350 PSI including checking of gas leakage points with halide torch/ soap foam solution in system including rectification of leakages by gas welding, tightening of all flare nuts, valves etc and after pressure test, flushing the system complete all as specified and directed.
Supply & charging refrigerant gas R-22 for 1.5/2.0 TR split/ window AC upto the required pressure and testing of plant complete all as specified and directed.
Material and labour for charging refrigerant gas in split type AC 1.5 TR capacity including vaccumizing, leakage test and rectification of leakages etc complete all as specified and directed. Note : Gas charges will be paid to contractor under other Sch item
All as per Srl Item No. 153.00 here-in-before but 2.0 TR
Material and labour for replacement of compressor sealed unit of capacity 1.5 TR unit suitable for Air conditioners split type including taking out to old unserviceable compressor and cleaning, flushing, vaccumizing the system, Re charging of gas in adequate quantity, soldering, brazing of suction, discharge and charging line complete all as specified and directed.
All as per Srl Item No. 155.00 here-in-before but 2.0 TR
Supply and fixing in replacement of copper pipe of size (1/2", 3/8", 1/4" & 5/8" dia heavy duty suitable for AC split type/ window type of capacity 1.5/2TR including cutting and soldering and testing and pressure etc complete all as specified
Supply and fixing new nitrile rubber insulation material for split air conditioner copper pipe of size 3/8" to 5/8" dia complete all as specified and directed
Supply, installation, commissioning and testing in replacement of voltage stabilizer copper wound for automatic operation, wall mounted type having connecting lead 3 core PVC insulated stranded copper conductor and connection plate for output correction, single phase naturally air cooled indoor type & designed for input variation between 150 Volts to 290 Volts with output voltage stabilized at 230 V with accuracy of ± 2.5% having voltmeter, indicator for normal running and low & high cut out of capacity 16 Amp complete all as specified.
Supply, installation, commissioning and testing in replacement of voltage stabilizer copper wound for automatic operation, wall mounted type having connecting lead 3 core PVC insulated stranded copper conductor and connection plate for output correction, single phase naturally air cooled indoor type & designed for input variation between 150 Volts to 290 Volts with output voltage stabilized at 230 V with accuracy of ± 2.5% having voltmeter, indicator for normal running and low & high cut out of capacity 12 Amp complete all as specified.
Supply and fixing AC box single pole & neutral sheet metal enclosure with 2 pin plus earth, 230 volts AC plug and socket suitable for MCB SPN,20 Amp complete all as specified.
Supply and fixing in replacement capillary copper (heavy duty) of size 1/64" suitable for split type AC of capacity 1.5/2 TR complete all as specified.
Supply and fixing for PCB remote plate of AC split type 1.5/2 Ton complete with remote, all as directed. Make of AC’s: LG/ Voltas/ Sidwal/ Carrier/ Videocon/ Blue Star
Supply and fixing in replacement condenser coil made out of copper pipe and fins suitable for split type AC 1.5 TR as per existing size and type including cutting, soldering, brazing and testing and charging of gas as required for air conditioner functional complete all as specified.
All as per Srl Item No. 164.00 here-in-before but 2.0 TR
Supply, replacement, connecting and testing of condensor blower motor as per existing type and size suitable for 1.5/2 TR split AC 240 volts single phase, all as directed. Make: Khaitan/ Universal/ CG/ Carriar/ Voltas
Supply and fixing in repair drain out pipe of split type AC complete all as specified and directed.
Supply and fixing in replacement evaporative coil made out of copper pipe and fins suitable for split type AC 1.5 TR as per existing size and type including cutting, soldering, brazing and testing and charging of gas as required for air conditioner functional complete all as specified.
All as per Srl Item No. 168.00 here-in-before but 2.0 TR
Taking down old and unserviceable compressor and Supply and fixing new sealed compressor unit for water cooler of capacity 40 Ltrs including cleaning, vaccumizing, gas charging and testing on load complete all as specified and directed.
All as per Srl Item No. 170.00 here-in-before but 80 Ltrs
Material and labour for charging of refrigerant gas in water cooler of capacity 40 ltr including vaccumizing, leakage test and rectification of leakages etc complete all as specified and directed. Note : Gas charges will be paid to contractor under other Sch item
All as per Srl Item No. 172.00 here-in-before but 80 Ltrs
Taking down old and unserviceable compressor and Supply and fixing new sealed compressor unit for deep freezer of capacity 405 Ltrs including cleaning, vaccumizing, gas charging and testing on load complete all as specified and directed. Make: Kirloskar/ Usha/ Carrier.
Rewinding of condenser motor of water cooler of capacity 40 to 80 Ltrs any make with super enameled copper wire including replacement worn out bushes etc and testing complete all as specified and directed.
Taking down old and unserviceable compressor and Supply and fixing new sealed compressor unit for refrigerator of capacity 415 to 551 Ltrs including cleaning, vaccumizing, gas charging and testing on load complete all as specified and directed.
Supply and fixing in replacement evaporative coil (cooling coil) of refrigerators of capacity 415 to 551 Ltrs including cutting, taking out to old coil, brazing/ soldering complete all as specified and directed.
Supply and fixing in replacement reversing valve 4 way complete with plunger, AC 220/240 Volts, 50-60 Hz all as specified and directed. Make Suswani cat part No. DHF-9 or equivalent.
Supply and fixing in replacement condenser fan motor, suitable to operate on AC, 220/ 240 V, 50 C/s for water cooler complete all as specified and directed.
Supply and fixing in replacement condenser fan motor, suitable to operate on AC, 220/ 240 V, 50 C/s for deep freezer complete all as specified and directed.
Supply only wood wool pad for desert cooler any size/ cap complete all as specified and directed.
Supply and fixing in replacement desert cooler motor 1/8 HP, copper wound, 3 speed complete all as specified and directed.
Supply and fixing tulu/ submersible pump for desert cooler complete all as specified and directed.
Supply and fixing overload/ PT relay suitable for AC/ water cooler/ deep freezer complete as per existing model as reqd at site all as specified and directed.
Supply and fixing capacitor 50 MFD complete all as specified and directed
Supply and fixing in replacement of running capacitor 10/ 15 /20 MFD for water cooler complete all as specified and directed
Supply and fixing in replacement old unserviceable fan blade for water cooler of any type and size, make as per matching to existing sample and size complete all as specified and directed
Supply and fixing in replacement old unserviceable thermostat as per existing sample/ make for water cooler/ refrigerator, complete all as specified and directed
Supply and fixing in replacement capacitor 4.0 MFD for desert cooler complete all as specified and directed
Material and labour for preparation of old painted surface of desert cooler including denting surface by applying putty after removing old paint, preparation of surfaces and applying two coats of spray painting with approved colour, complete all as specified and directed Note : Colour code shall be approved by Engineer-in-Charge
Material and labour for charging refrigerant gas R-134a or 410a in old or new compressor and makeup required pressure including brazing and testing complete all as specified and directed
Northern cable fault locatoers
M/s GURFATEH BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .