| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹40.8 LAccepted-AOC | 1 | Accepted-AOC Being lowest and reasonable rates | |
| 2 | 2₹42.2 L+₹1.5 L (3.63%)Rejected-Finance | 2 | Rejected-Finance Not being a lowest tenderer | |
| 3 | 3₹43.7 L+₹2.9 L (7.15%)Rejected-Finance PLOT NO RZ B 1 59 KH NO 534 535 BLOCK B 1 NEW ROHANPURA PP NO 1416 NAJAFGARH NEW DELHI 110043 | NEW DELHI | NAJAFGARH | DELHI | 110043 | 3 | Rejected-Finance Not being a lowest tenderer | |
| 4 | 4₹47.5 L+₹6.7 L (16.5%)Rejected-Finance PLOT NO 59 60 WAZIDPUR JAIMAU KANPUR 208010 | KANPUR NAGAR | UTTAR PRADESH | 208010 | 4 | Rejected-Finance Not being a lowest tenderer | |
| 5 | 5₹49.4 L+₹8.6 L (21.2%)Rejected-Finance | 5 | Rejected-Finance Not being a lowest tenderer |
Tender Value
₹43.7 L
EMD Value
₹88,000
Closing Date
13 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE (U) DELHI CANTT-10
HQ CWE (U) DELHI CANTT-10
PROVISION OF ROOF COVERNING NEAR MT AREA AT DIPAC UNDER AGE (I) (U) B/R DELHI CANTT-10
2022_MES_543916_1
CWE(U)/D-16/2022-23
Open Tender
Civil Works
Item Rate
150 days
HQ CWE (U) DELHI CANTT-10
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
of AGE(I) (U) B/R, Delhi Cantt-110010
₹88,000
Yes
19 Sept 2022
6 Aug 2022
15 Sept 2022
6 Aug 2022
13 Sept 2022
1 Sept 2022
Amount
Excavation in trenches , not exc 1.5 m wide and n exc 1.50 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exc 10 sqm on plan and not exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed
M&L PCC 1:4:8 type D-2 (using 40mm graded stone aggregates), as in foundation filling and mass concrete complete all as specified and as directed.
M&L for TMT bars 10mm dia and over cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed.
M&L for TMT bars 6 to 8mm dia and over cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed .
M&L for Formwork to sides of flat concrete foundations, footings, bases of coullmns, raft and raft beams, sides and soffits of foundations and plinth beams and similar work complete all as specified and directed
M&L for Formwork to sides of pillars, posts, struts, piers, columns and sanchions complete all as specified and directed
M&L for fair finished surface concrete formwork to edges of concrete flats, treads, breaks in floor, window cills, concrete railing, opening in concrete wall, floor and roof n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or slopping and similiar work exc 5cm but n.exc 10cm wide complete all as specified and directed
M&L for RCC M-25 concrete using 20 mm graded stone aggregate as in foundation including rafts footings , foundations beams, plinth beams, bases for coulmns etc basement slab, undereamed piles and mass concerte all as specified and dirceted
M&L for Reinforced cement concrete (nominal mix) of 1:2:4 type B-1 (20mm graded aggregate) as in columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L for RCC nominal mix Type B1, 1:2:4 using 20 mm graded stone aggregate as in slabs suported on walls, complete all as specified and dirceted
Returning , filling in incl spreading levelling and well ramming and watering in layers n exc 25 cm complete all as specified and directed
M&L for Removing excavated material n.exc 50 m and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed.
M&L hardcore of broken stone or boulders of guage n.exc 63 mm deposted, spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface complete all as speciffied and directed
M&L for for hardcore of broken brick of gauge n.exc 63mm deposite spread and levelled in layer n.exc 15cm thick watered and well rammed to true surface complete all as specified and as directed.
M&L for 75MM thick cement concrete type C-1 (1:3:6) ( 40 mm graded aggregate) as in plinth protection complete all as specified and directed
M&L brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius in cement mortar 1:6 complete all as specifed and directed
M&L brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:6 complete all as specifed and directed
M&L for 15 mm thick Ready mix plaster, on brickwork or concrete surface of wall other then fair faces of brick/ Concrete surface (External surfaces) finished even and smooth complete all as specified and directed.
M&L for 10 mm thick Ready mix plaster, on fair faces of brickwork or concrete surface of wall (Internal surfaces) finished even smooth complete all as specified and directed.
M&L preparation of new plasterd or unplastered concrete surfaces and apply two coat of cement base paint over a coat of primer complete all as specified and directed
M&L for preparation of newly plastered surfaces of wall & apply three coats of white wash complete all as specified and directed
S&F rolled mild steel in joist, channel, angle or tee section, fixed independently, without connecting plates, etc (cut to ordinary length i.e within 20mm of the length indicated using Fe 410-W(Grade E 250) quality A complete all as specified and directed
S&F for steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and directed
M&L for preparation of new steel surfaces of any description over 10 cm width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer, complete all as directed.
S&F Plates ( Plain or chequred) channels, squre cut or notched ( ordinary and counter sunk) forming holes, with riveted, bolted or welded attachement complete all as specified and concrete
M&L for holes drilled up to dia 12 mm and not exc 25 mm dia and countersunk if required up to depth exc 2 mm but not exc 12 mm complete all as specified and directed.
S&F mild steel 25 mm dia rag or lewis bolts, screwed one end with hexagonal or square nuts and washehers, the other end enlarged and jagged or lewished exc 30 cm long fixed with RCC foundation complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating AZ-150 GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self drilling screws or cranked bolts other necessary fittings,complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating Az-150 GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge fixed with self drilling screws complete all as specified and directed.
Supply only chain link MS galvanised fencing any size or any type including galvanised mild steel plain wire 4mm dia complete all as specified & directed by Engineer - in -charge.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, including provission of binding wire complete all as specified and directed.
MS work as in posts and struts of fencing, fillets, plates etc including cutting tops to shape as directed, drilling holes, notching for wire etc including all necessary drilling, bolting or rebating etc complete confirming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
M&L mild steel round bars 10mm dia and over, cut to length, bent to shape required incl cranking, bending spirally for hoping for columns hooking ends and bindind with ms wire (annealed) not less than 0.9mm dia quality confirming to all as specified. (fe-410-W (Gde.E-250) quality- A or Fe 290(Gde.E-165) complete all as specified and directed.
S&F domic type stainless steel post of any size with stainless steel plate on bottom and hook on top to receive chain or other items fixed on concrete surface with screws and adhesive finished and polsihed complete including making good disturbed surfaces complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25mm thick over 15mm thick in 1:6 cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for kota stone 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10mm thick cement screed and jointed with ditto as per item No. 28 above complete all as specified and as directed.
S&F Aluminium turbo ventilator of 600mm(Throat dia), 32/36 nos of fins, 0.5mm thickness of top cover & ring, corrugated type rolled formed fins, waight 4-5 Kg andhight 18'' with ISI mark fixing base frame on to mounting ring with sot weldig complete all as specified and directed.
M&L for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall/ roof/floor by cutting of chases in wall on wall including sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc complete all as specified and directed for One light/fan / bell point controlled by one, one way switch 05 Amps complete all as specified and directed.
All as per above item No 38 here-in-before but one 3 pin, 05 Amps socket outlet point on independent board controlled by one, one way 05 Amps switch complete all as specified and directed.
All as per above No 38 item above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
S&F switch piano flush type, 05 Amps, single pole, one way, 250 volts complete all as specified & directed
S&F switch piano flush type, 15 Amps, single pole, one way, 250 volts complete all as specified & directed
S&F socket outlet 2 in 1, 5 pin, 05 Amps, flush type, 250 volts with socket frame complete all as specified & directed
S&F socket outlet 2 in 1, 3 pin, 05 Amps and 3 pin, 15 Amps, flush type, 250 volts with socket frame complete all as specified & directed
S&F ceiling rose, 6 Amps, 250 volts, AC, ISI marked with three equal size terminals complete all as specified & directed
S&F LED street light 35 watt 230 Volt AC outdoor type with high pressure die cast aluminium hosing and heatresistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fix 100 Watt high efficiency round highbay in PDC housing suitable for industrial luminair efficincy upto 110 Lm/W reduce quality/ wattage thoroly reducing operational cost ingress protection of IP 66 with additional safety chain complete all as specified and directed.
M&L for sub main wiring with 6.0 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 6.0 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified & directed, including taking down old sub main wiring complete all as specified and directed. Note FOR ITEM NO 48 :- Two run meter of 6 Sqmm cable and one run of 6 sqmm cable as earth continuity conductor and one run of PVC conduit with assessories shall be measured and paid as one unit length.
S&F sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 8way, with 200 Amps rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed.
S&F MCB, TPN, 4 Pole , AC, 415 volts of 100 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and directed.
S&F MCB, SP, AC, 240 volts of 10 to 40 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and directed.
S&F MCB, SPN, AC, 240 volts of 63 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and directed.
M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and directed.
M&L for Sand coarse filling in trenches obtained from local river for cushioning of UG cable complete all as specified and directed.
Supply and laying well burnt best quality locally available bricks of size 25X12.5X7.5 cm (+/-) 8% tolerance laid flat for protection of UG cable complete all as specified and directed.
M&L tubing GI light grade laying for protection of LT under ground cable of size 50mm bore complete all as specified and directed.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 3.5 core complete all as specified and directed.
M/s Pawar Builders
M/S CHANDER MUNI
B. S BUILDERS
Som Nath Kakkar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .