Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹18,024Qualified Make: FLUKE
Model: fluke 115 HOUSE NO 24 BHAGAT SINGH MARG POLO II MANDORE ROAD JODHPUR RAJASTHAN RAJASTHAN 342001 | JODHPUR | RAJASTHAN | 342001 | Make: FLUKE
Model: fluke 115 | ₹18,024 | L1 | Qualified |
| 2 | Disqualified Make: Keysight Technologies
Model: Keysight U1232A E 366 2ND FLOOR NIRMAN VIHAR VIKAS MARG VIKAS MARG VIKAS MARG NEW DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | Make: Keysight Technologies
Model: Keysight U1232A | - | - | Disqualified |
| 3 | Disqualified Make: Metrel
Model: metrel MD9030 29 D SECTOR BERKHEDA BHEL BHOPAL MADHYA PRADESH 462021 | BHOPAL | MADHYA PRADESH | 462021 | Make: Metrel
Model: metrel MD9030 | - | - | Disqualified |
| 4 | Disqualified Make: FLUKE
Model: Fluke 115 212 AGARAWAL CITY SQURE MANGALAM PALACE ROHINI SECTOR 3 NORTH WEST DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | Make: FLUKE
Model: Fluke 115 | - | - | Disqualified |
| 5 | Disqualified Make: FLUKE
Model: Fluke 17 B+ 122 KANCHAN BAGH KANCHAN BAGH KANCHAN BAGH INDORE MADHYA PRADESH 452001 | INDORE | MADHYA PRADESH | 452001 | Make: FLUKE
Model: Fluke 17 B+ | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
24 Aug 2018, 2:00 pmClosed
Digital Multimeter ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Type Hand Held Hand Held Display (Digits) 3.5 3.5 Measurement Type True RMS True RMS Counts 6000 4000
6000
50000
200000 (or higher) MEASUREMENTS DC Voltage Range 600 600
1000 DC Voltage Accuracy 0.05 0.005
0.05
0.1
0.5
1 DC Voltage resolution 0.1 0.001
0.01
1
10
100 AC Voltage Range 600 600
1000 AC Voltage Accuracy 0.1 0.08
1 AC Voltage resolution 0.1 0.001
100 DC Current Range 3 3
10 DC Current Accuracy 0.05 0.005
1.5 1/5 DC Current resolution 0.1 0.001
100 AC Current Range 3 3
10 AC Current Accuracy 1 0.5
1.5 AC Current resolution 0.1 0.001
100 Resistance Range 50 40
50
60
100
500 Resistance Accuracy 1 0.08
1.5
2
2.5
3
3.5 Resistance resolution 0.1 0.001
100 Capacitance Range ( Micro farad ) 1 to 100 1 to 100
1 to 200
.01 to 1000
NA Capacitance Accuracy ( % ) 2.5 1.5
3.5
5
NA Capacitance resolution ( nF ) 1 0.001
NA Frequency Range ( KHz ) 50 50
200
300
NA Frequency Accuracy ( % ) 0.1 0.1
NA Frequency resolution ( Hz ) 0.1 0.001
NA Temperature Range ( Degree C ) -40 to 400 -40 to 400
50 to 1000
NA Temperature Accuracy ( % ) 1.5 1.5
NA Temperature resolution ( Degree C ) 1 0.001
NA OTHER FEATURES Continuity test and Diode test Available * Data logging Not Available * If Data Logging Feature is Available
Internal Memory NA * Computer Interface along with software Available * Dimensions ( mm X mm X mm ) NA * Weight 500 * Other Features NA * SAFETY Safety Rating Category II 600 V of IEC 61010. Category II 600 V of IEC 61010.
Category II 1000 V of IEC 61010.
2/5 Category III 600 V of IEC 61010.
Category III 1000 V of IEC 61010.
Category IV 600 V of IEC 61010
Category IV 1000 V of IEC 61010 Safety Certification UL * POWER REQUIREMENTS Power Requirements 230 V +/-10% AC
50 Hz +/- 3% through Adaptor * if Battery Operated
then Type of Battery Rechargeable * if rechargeable
then chemistry of the battery lithium ion * if Non-rechargeable
then size of the battery cell AAA * number of non- rechargeable the battery/cell 2 * Voltage of rechargeable Battery 0 * capacity of rechargeable battery(milli Ampere Hour) 10 * Suitable charger adaptor provided YES * ACCESSORIES Standard Accessories Supplied with the Equipment NA * WARRANTY Warranty 2 1
5 OPERATING CONDITION Minimum Operating Temperature 0 * Maximum Operating Condition 60 * Operating Humidity (RH) 90 * TEST REPORT DETAILS The equipment supplied with calibration certificate YES * conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest true * 3/5 conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH true * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number and date for the specification test 001. 01 JULY 2017 * Name and address of the Lab for the specification test NABL Accredited laB * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Omendra Singh 227412
HAL AVIONICS DIVISION KORWA PO-HAL KORWA AMETHI-227412 UP 2 60
414404
GEM/2018/B/58621
digital multimeter
60 days
Uttar Pradesh; Amethi
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Digital Multimeter ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Type Hand Held Hand Held Display (Digits) 3.5 3.5 Measurement Type True RMS True RMS Counts 6000 4000 | - | - | - |
| 6000 | - | - | - |
| 50000 | - | - | - |
| 200000 (or higher) MEASUREMENTS DC Voltage Range 600 600 | - | - | - |
| 1000 DC Voltage Accuracy 0.05 0.005 | - | - | - |
| 0.05 | - | - | - |
| 0.1 | - | - | - |
| 0.5 | - | - | - |
| 1 DC Voltage resolution 0.1 0.001 | - | - | - |
| 0.01 | - | - | - |
| 1 | - | - | - |
| 10 | - | - | - |
| 100 AC Voltage Range 600 600 | - | - | - |
| 1000 AC Voltage Accuracy 0.1 0.08 | - | - | - |
| 1 AC Voltage resolution 0.1 0.001 | - | - | - |
| 100 DC Current Range 3 3 | - | - | - |
| 10 DC Current Accuracy 0.05 0.005 | - | - | - |
| 1.5 1/5 DC Current resolution 0.1 0.001 | - | - | - |
| 100 AC Current Range 3 3 | - | - | - |
| 10 AC Current Accuracy 1 0.5 | - | - | - |
| 1.5 AC Current resolution 0.1 0.001 | - | - | - |
| 100 Resistance Range 50 40 | - | - | - |
| 50 | - | - | - |
| 60 | - | - | - |
| 100 | - | - | - |
| 500 Resistance Accuracy 1 0.08 | - | - | - |
| 1.5 | - | - | - |
| 2 | - | - | - |
| 2.5 | - | - | - |
| 3 | - | - | - |
| 3.5 Resistance resolution 0.1 0.001 | - | - | - |
| 100 Capacitance Range ( Micro farad ) 1 to 100 1 to 100 | - | - | - |
| 1 to 200 | - | - | - |
| .01 to 1000 | - | - | - |
| NA Capacitance Accuracy ( % ) 2.5 1.5 | - | - | - |
| 3.5 | - | - | - |
| 5 | - | - | - |
| NA Capacitance resolution ( nF ) 1 0.001 | - | - | - |
| NA Frequency Range ( KHz ) 50 50 | - | - | - |
| 200 | - | - | - |
| 300 | - | - | - |
| NA Frequency Accuracy ( % ) 0.1 0.1 | - | - | - |
| NA Frequency resolution ( Hz ) 0.1 0.001 | - | - | - |
| NA Temperature Range ( Degree C ) -40 to 400 -40 to 400 | - | - | - |
| 50 to 1000 | - | - | - |
| NA Temperature Accuracy ( % ) 1.5 1.5 | - | - | - |
| NA Temperature resolution ( Degree C ) 1 0.001 | - | - | - |
| NA OTHER FEATURES Continuity test and Diode test Available * Data logging Not Available * If Data Logging Feature is Available | - | - | - |
| Internal Memory NA * Computer Interface along with software Available * Dimensions ( mm X mm X mm ) NA * Weight 500 * Other Features NA * SAFETY Safety Rating Category II 600 V of IEC 61010. Category II 600 V of IEC 61010. | - | - | - |
| Category II 1000 V of IEC 61010. | - | - | - |
| 2/5 Category III 600 V of IEC 61010. | - | - | - |
| Category III 1000 V of IEC 61010. | - | - | - |
| Category IV 600 V of IEC 61010 | - | - | - |
| Category IV 1000 V of IEC 61010 Safety Certification UL * POWER REQUIREMENTS Power Requirements 230 V +/-10% AC | - | - | - |
| 50 Hz +/- 3% through Adaptor * if Battery Operated | - | - | - |
| then Type of Battery Rechargeable * if rechargeable | - | - | - |
| then chemistry of the battery lithium ion * if Non-rechargeable | - | - | - |
| then size of the battery cell AAA * number of non- rechargeable the battery/cell 2 * Voltage of rechargeable Battery 0 * capacity of rechargeable battery(milli Ampere Hour) 10 * Suitable charger adaptor provided YES * ACCESSORIES Standard Accessories Supplied with the Equipment NA * WARRANTY Warranty 2 1 | - | - | - |
| 5 OPERATING CONDITION Minimum Operating Temperature 0 * Maximum Operating Condition 60 * Operating Humidity (RH) 90 * TEST REPORT DETAILS The equipment supplied with calibration certificate YES * conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest true * 3/5 conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH true * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number and date for the specification test 001. 01 JULY 2017 * Name and address of the Lab for the specification test NABL Accredited laB * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Omendra Singh 227412 | - | - | - |
| HAL AVIONICS DIVISION KORWA PO-HAL KORWA AMETHI-227412 UP 2 60 | - | - | - |
Exempted
24 Aug 2018
25 Sept 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_414404.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .