Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance JOGI LANKAR RAINAWARI JOGI LANKAR RAINAWARI LANKAR RAINAWARI LANKAR RAINAWARI SRINAGAR JAMMU KASHMIR 190003 | SRINAGAR | JAMMU AND KASHMIR | 190003 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
25 Apr 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, ED-3rd srinagar
Office of Executive Engineer, ED-3rd srinagar
Rate Contract for Procurement of material that may be required during the emergencies for the year 2025-26 in respect of ED-3rd
2025_PDD_275148_1
ED-III /05 of 2025-26, Dated- 04/04/2025
Open Tender
Electrical Goods/Equipments
Item Wise
7 days
Office of Executive Engineer, ED-3rd srinagar
Refer SBD, Technical Specification, Drawing
7 documents required · 7 mandatory
₹1,000
Executive Engineer, ED-3rd srinagar
₹50,000
9 May 2025
4 Apr 2025
26 Apr 2025
4 Apr 2025
25 Apr 2025
11 Apr 2025
4 Apr 2025 - 21 Apr 2025
Suppy of
50 mm² AB (HT) Cable (3x50 + 1x70 mm²) XLPE(11 kV, 3C + Earth)
70 mm² AB (HT) Cable (3 x 70 + 95 mm²) XLPE(11 kV, 3C + Earth)
120 mm² AB (HT) Cable (3x120 + 1x95 mm²) XLPE(11 kV, 3C + Earth)
150 mm² AB (HT) Cable (3x150 + 1x95 mm²) XLPE(11 kV, 3C + Earth)
185 mm² AB (HT) Cable (3x185 + 1x95 mm²) XLPE(11 kV, 3C + Earth)
11 kV Heat Shrinkable Outdoor Cable Termination Kit Upto 50- 95 sqmm ( 3 core)
Heat Shrinkable Outdoor Cable Termination Kit above 120 to 185 sqmm ( 3 Core)
Mid Span Straight Through Jointing Kit for 11 kV ABC 120 -185 sqmm
35 mm² AB (LT) Cable ( 3 x 35 + 1 x 16 + 1 x 25 mm²(insulated Messenger)) XLPE (1.1kV, 3+1 C, Al)
50 mm² AB (LT) Cable ( 3 x 50 + 1 x 16 + 1 x 35 mm²(insulated Messenger)) XLPE (1.1kV, 3+1 C, Al)
70 mm² AB (LT) Cable ( 3 x 70 + 1 x 16 + 1 x 50 mm²(insulated Messenger)) XLPE (1.1kV, 3+1 C, Al)
95 mm² AB (LT) Cable ( 3 x 95 + 1 x 16 + 1 x 70 mm²(insulated Messenger)) XLPE (1.1kV, 3+1 C, Al)
120 mm² AB (LT) Cable ( 3 x 120 + 1 x 16 + 1 x 70 mm²) XLPE (1.1kV, 3+1 C, Al)
Mid Span Straight Through Jointing Kit for 1.1 kV ABC 95-150 sqmm
Mid Span Straight Through Jointing Kit for 1.1 kV ABC 35-70 sqmm
70 mm² Single-Core Cable, 1.1kV Grade, XLPE un-armoured FRLS type
95mm² XLPE LT Cable Single Core, un-armoured, FRLS
120 mm² XLPE LT Cable Single Core, un-armoured, FRLS
150 mm² XLPE LT Cable Single Core, un-armoured, FRLS
185 mm² Cable, 1.1kV Grade, XLPE un armoured FRLS type
240 mm² Single Phase Cable,1.1K V Grade, XLPE un armoured FRLS type
300 mm² XLPE LT Cable Single Core, un-armoured, FRLS
400 mm² Single Phase Cable,1.1K V Grade, XLPE un armoured FRLS type
500 mm² XLPE LT Cable Single Core, un-armoured, FRLS
630mm² XLPE LT Cable Single Core, un-armoured, FRLS
10 mm² Cable (2C), 1.1k V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type
16 mm² Cable (2C), 1.1k V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type
10 mm² Cable (4C), 1.1k V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type
16 mm² Cable (4C),1.1k V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type
25 mm² XLPE LT Cable 4 Core, armoured, FRLS
35 mm² XLPE LT Cable 4 Core, armoured, FRLS
Single Core 1 mm² cable copper wire , 1.1 kV Grade, ISI, FRLS.
Single Core 1.5 mm² cable copper wire , 1.1 kV Grade, ISI, FRLS.
Single Core 2.5 mm² cable copper wire , 1.1 kV Grade, ISI, FRLS.
Single Core 4 mm² cable copper wire , 1.1 kV Grade, ISI, FRLS.
Single Core 6 mm² cable copper wire , 1.1 kV Grade, ISI, FRLS.
11 kV, 3- Core XLPE 35 mm² round wire Armoured, FRLS Cable
11 kV, 3- Core XLPE 50 mm² round wire Armoured, FRLS Cable
11 kV, 3- Core XLPE 70 mm² round wire Armoured, FRLS Cable
11 kV, 3- Core XLPE 120 mm² round wire Armoured, FRLS Cable
11 kV, 3- Core XLPE 150 mm² round wire Armoured, FRLS Cable
11kV, Three core 185 mm2 Aluminium round wire Armoured XLPE Cable , FRLS
11 kV, 3- Core XLPE 240 mm² round wire Armoured, FRLS Cable
11 kV, 3- Core XLPE 400 mm² round wire Armoured, FRLS Cable
11 KV End termination for 3C 120- 185 mm²
11 KV End termination for 3C 240 to 400 mm²
11 KV Straight Through Jointing Kit upto 50-95 mm²
11 KV Straight Through Jointing Kit upto 120-185 mm²
11 KV Straight Through Jointing Kit upto 240-300 mm²
11 KV Straight Through Jointing Kit upto 400 mm²
LT Distribution Box for 25 kVA DTR with 40 Amp MCCB 3P 16 kA for incomer & 25 Amp MCCB 3P 16 kA/10 kA 1 No. each (=2No.) for Outgoing Circuits .
LT Distribution Box for 63 kVA DTR with 100 Amp MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 1 No. and 63 Amp MCCB 3P 16 kA 1 No.s for Outgoing Circuits
LT Distribution Box for 100 kVA DTR with 160 MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 2 No.s for Outgoing Circuits
LT Distribution Box for 200 kVA DTR with 315 Amp MCCB 3P 25 kA for incomer & 160 Amp MCCB 3P 16 kA 3 No.s for Outgoing Circuits
LT Distribution Box for 250 kVA DTR with 400 Amp MCCB 3P 36 kA for incomer & 200 Amp MCCB 3P 16 kA 1 No. and 160 Amp MCCB 3P 16 kA 2 No.s for Outgoing Circuits
LT Distribution Box for 400 kVA DTR with 630 AMP MCCB 3P 36 kA for incomer & 200 Amp MCCB 3P 16 kA 4 No.s for Outgoing Circuits
LT Distribution Box for 400 kVA DTR with 630 AMP MCCB 3P 36 kA for incomer & 200 Amp MCCB 3P 16 kA 4 No.s for Outgoing Circuits
Temporary LT Fuse Set for Distribution Transformers (Customised) as per KPDCL Drawing no. CE/P&P/DRG/2023/LTFS/001 (enclosed)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm Nos
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
16 KN Polymer Shackle Insulator
G.I Mukey for Shackle Insulators with bolt of (50x6)mm
GI U-Clamps for Shackle Insulator with nuts and bolts
11 KV Link set Heavy Duty with copper blade size of 14 inch, 50 x 6 mm, female Contact of copper 6 mm thickness, with post insulator of 10 KN
11 KV GO, AB Switch 3-Phase, 3-Pole,200 Amp, Vertical Type Set
11 kV Horn Gap Fuse Set 3 Phase 200A Set
PG Clamps for 30 mm² ACSR Conductor
PG Clamps for 50 mm² ACSR Conductor
PG Clamps for 100 mm² ACSR Conductor
Suspension/Tension Clamp with eye hook
GI Pole Support Clamp including GI Nut and Bolts for 11 Mtr Pole with size - 50x8x376 mm
GI Pole Support Clamp including GI Nut and Bolts for 9 mtr pole with size - 50x8x376 mm
GI Pole Support Clamp including GI Nut and Bolts for 8 mtr with size 50x 8x 328 mm
GI Pole Support Clamp including GI Nut and Bolts for 8 mtr or 9 mtr PCC with size 50x8x441mm
Cable tie (each packet contains 100 Nos.)
Cable end caps
Insulating Piercing Connectors of sizes
11 KV IPC (Insulation piercing conductors)for bare to CC(covered conductor) connection
11 KV IPC for Covered Conductor to Covered Conductor connection
Main Single Phase Service Distribution Box (Pole DB) Along with MCCB /MCB as per REC Drawing. The DB should have Bottom entery of Cable with proper Glands/grommets-Safety Screws and Back Clamp suitable for 11/9/8 Mtr ST Pole or 9/8 mtr PCC poles with Nuts/bolts
Main 3 Phase Distribution Box IP 54 (Pole DB) made from 20 SWG CRCA MS sheet by Deep Drawn Method with Powder Coating. Internal size of the box shall be 225mm x 285mm x 120mm used for connection through ABC line and for giving connections to the consumers 3phase-1 incoming 4 outgoing I/C- 1, O/G-2-4 (200 A, 0.415 kV) for RYB Phase. The DB should have Bottom entery of Cable with proper Glands/grommets-Safety Screws and Back Clamp suitable for 11/9/8 Mtr ST Pole or 9/8 mtr PCC poles with Nuts/bolts
LT Line Spacers 3 p ,4 wire
LT Line Spacers 2 p ,3 wire
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
3-Ø, 4-Wire Trivector Meter with CT
Single Phase Smart Energy Meter 5-30 Amp/ 10-60 Amp, DLMS Complaint of accuracy class 1.0
Three Phase Smart Energy Meter 20-80 Amp/, DLMS Complaint of accuracy class 1.0
Polypropylene weather proof outdoor type Meter Box for Single Phase Meter along with Zinc plated clamps
Polypropylene weather proof outdoor type Meter Box for Three Phase Meter along with Zinc plated clamps
Polypropylene weather proof outdoor type Meter Box for 4 Single Phase Meter along with Zinc plated clamps
GI Barbed Wire for Anti Climbing
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Cemical Earthing Complete
Earthing Mat (GI Flat 50 mm x8 mm)/(75 x10)mm/(75x8)mm
GI Pipe 40 mm 3 mtr long for Earthing
Earthing Electrode ( 3m long) 20 mm dia.
GI Strip 25x3 mm
Galvanized earthing strips 50mm x3mm.
Red Oxide
Aluminium Paint
Galvanized Nuts and Bolts
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2No..), anchor plate (200x 200 x 6 mm), nut-bolts, 2 No. turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete (11 kV)
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete (33 kV)
GI V cross-arm with top Bracket including clamp
GI Channel X-arm including clamps and braces
GI Extension Riser of sizes
GI Wire 6 SWG & 8 SWG
Guard netting (for 52 Mtr Span)
Aluminium Jointing Sleeves 100 Sqmm
Aluminium Jointing Sleeves 50 Sqmm
Aluminium Jointing Sleeves 30 Sqmm
Suspension Fitting (2 Bolt) for 11 kV line
Tension Fitting (4 Bolt) for 11 kV line
Suspension/Tension Clamp with eye hook
Earth wire 7/4 sqmm
1 phase 2 wire, 415V, 1nos of 100 Amps incoming SP MCCBs fitted with outgoing 04 No 32 Amps SP MCBs for Service Connections, Distribution Service Pillar suitable for outdoor installation, made out of CRCA sheet painted through 7-tank process with PU painted Busbars 2P, Aluminium with heat shrinkable sleeves and adequate capacities complete with all accesories 4 way Distribution Service Pillar.
3 phase, 415V, 1no of 250 Amps incoming 3 TP MCCBs (Breaking 36KA) fitted withoutgoing 03 No 100 Amps SP MCCBs, 1No.100Amps 3 pole MCCB for outgoing LT cables, Distribution feeder Pillar suitable for outdoor installation , made out of CRCA sheet painted through 7-tank process with PU painted Busbars 4P, Aluminium with heat shrinkable sleeves and adequate capacities complete with all accesories 4 way Distribution Feeder Pillar.
Fire Extingiusher Co₂ Type of 4.5 kg capacity for control room
3 Sand Bucket Fire Extingiusher
Gum Boots with Steel Toe of Sizes
Winter Jacket- Coat ECC consists of three independent components that is Wind Cheater ( Waterproof ), Insulating Layer and Waist Coat ( Sleeve less ), Three Layer Waterproof Breathable fabric, Dual Shade OG/ White, Material of Insulating Layer- 1. Batting Polyester, 100 GSM, 2. Fabric Nylon Knitted Aluminized, 3. Fabric Nylon 75 GSM White, Material of Waist Coat- Double Layer Bonded Polyester Fleece
Safety Vest - Reflective Luminous Garments - High visibility warning garments with synthetic slide fasteners, Fluorescent yellow, Width of retro reflective material for all types of garments (minimum) 50 millimeter
Non-Contact Voltage Detector, Upon Detection, Tip Glows and Beeper Sounds, Cat Iv 1000 V for Added Protection, Expanded Range: 90 V to 1000 V Ac or 200 V to 1000 V AC, Battery Cell operated (2 AAA or Standard), Voltbeat Technology and Continuous Self-test
Safety Helmet- Quality of Shell High quality, high impact, light weight,Tough, Conformity to specification- IS 2925:latest ,EN 397 certified
Safety Rubber Gloves up to 15 KV as per IEC Standard
Safety Belt/Harness with Shock Absorber
Safety Shoes of sizes -Personal Protective Equipment - Safety Footwear as per BIS specification No IS 15298 ( Part 2 ): 2016, Toe Cap- ( Steel ) Metallic, Insole, Classification- Class I ( Footwear made from leather and other materials, excluding all-rubber or all-polymeric footwear ) with different sizes, Slip Resistant- As per clause 5.3.5.4 of IS 15298 ( Part 2 )- Slip resistance on ceramic tile floor with NaLS and on steel floor with glycerine.
11 KV Earthing/Discharging rod (set of 3 rods) Set with minimum 20 sqmm cable and u-clamp
Battery operated 12 kV Voltage Detector (CPRI Tested) complete kit including HV detector probe, 20 feet FRP insulation stick, carrying bag. The detector should have audio as well as visual anunciation, sensing distance of 1 meter for 11kV. Bright high intensity Red LED's for visual annunciation even in unfavourable daylight conditions and a buzzer to produce loud beep audible even in noisy backgrounds
Alumunium Ladder 2*20 ' (Double Ladder) 3 mm Thick Anti Corossion, Anodised, Bottom Rubber, Sliding type with Rope and pulley arrangement
Alumunium Ladder 2*15 ' (Double Ladder) 3 mm Thick Anti Corossion, Anodised, Bottom Rubber, Sliding type with Rope and pulley arrangement
Aluminium Ladder 2*10 Ft Long, Anti Corossion, Anodised, Bottom Rubber, Sliding type with Rope
Bamboo Ladder
Wooden Ladder 17 feet Long
Wooden Ladder 20 feet Long
Telescopic Ladder 20 Ft Long
Hand Held Search Light Led lamp, 100 Watt with Lithium ion 3.7 V, 3.5 AH, 500 Lux/100 Mtr with Lamp life -50000 Hours, IP 65, 12 Months Warranty
HDPE Pipe Outer Dia 180 mm Inner Dia 152 mm for laying of 11kV XLPE Cable from Power Transformer to Control Room
MCCB - 200 Amps,36KA,4P adjustable
MCCB - 40 Amps,36KA,4P adjustable
MCCB - 63 Amps,36KA,4P adjustable
MCCB - 100 Amps,36KA,4P adjustable
MCCB - 160 Amps,36KA,4P adjustable
MCCB - 250 Amps,36KA,4P adjustable
MCCB - 400 Amps,36KA,4P adjustable
MCCB - 630 Amps,36KA,4P adjustable
MCCB - 200 Amps,36KA,3P adjustable
MCCB - 100 Amps,36KA,3P adjustable
MCCB - 160 Amps,36KA,3P adjustable
MCCB - 250 Amps,36KA,3P adjustable
MCCB - 400 Amps,36KA,3P adjustable
MCCB - 630 Amps,36KA,3P adjustable
Bobin Insulators clamps/cliffs.
Epoxy Resin Cast Panel Insulators Upto 500mm
18 feet Fiber Link Rod
18 feet Bamboo Link Rod
Al. Solderless clamps suitable for transformer 1000 KVA as per relevant IS
Al. Solderless clamps suitable for transformer 630 KVA as per relevant IS
Al. Solderless clamps suitable for transformer 400/500 KVA as per relevant IS
Al. Solderless clamps suitable for transformer 250 KVA as per relevant IS
Al. Solderless clamps suitable for transformer 100 KVA as per relevant IS
Al. Solderless clamps suitable for transformer 63 KVA as per relevant IS
Aluminium Thimbles 630 mm2 as per relevant IS
Aluminium Thimbles 500 mm2 as per relevant IS
Aluminium Thimbles 400 mm2 as per relevant IS
Aluminium Thimbles 300 mm2 as per relevant IS
Aluminium Thimbles 240 mm2 as per relevant IS
Aluminium Thimbles 185 mm2 as per relevant IS
Aluminium Thimbles 120 mm2 as per relevant IS
Aluminium Thimbles 95 mm2 as per relevant IS
Aluminium Thimbles 70 mm2 as per relevant IS
Aluminium Thimbles 35 mm2 as per relevant IS
Aluminium Thimbles 25 mm2 as per relevant IS
Aluminium Thimbles 16 mm2 as per relevant IS
DPC Copper Winding wire (round) in sizes 11 to 22 SWG Fresh.
DCP Copper Strip of sizes for LV winding of Distribution Transformers 250 KVA to 630 KVA Fresh.
SE Copper Winding wire (round) in sizes 11 to 22 SWG.
DPC Aluminium winding wire (round) in sizes from 12 to 20 SWG-Fresh
DPC Aluminium strip of sizes for LV winding of Distribution Transformers 25 KVA to 630 KVA - Fresh
SE Aluminium Winding wire (round) in sizes 12 to 20 SWG-Fresh
DPC Copper winding wire (round) in sizes 12 to 20 SWG ( in exchange of one Kg of scrap of salvaged conductor)
DPC Copper strip of sizes for LV winding of Distribution transformers 25 KVA to 630 KVA( in exchange of one Kg of scrap of salvaged conductor)
SE Copper Winding wire (round) in sizes 11 to 22 SWG ( in exchange of one Kg of scrap of salvaged conductor)
DPC Aluminium winding wire (round) in sizes from 12 to 20 SWG ( in exchange of one Kg of scrap of salvaged conductor)
DPC Aluminium strip of sizes for LV winding of Distribution Transformers 25 KVA to 630 KVA ( in exchange of one Kg of scrap of salvaged conductor)
SE Aluminium Winding wire (round) in sizes 12 to 20 SWG ( in exchange of one Kg of scrap of salvaged conductor)
LV Brass Bush Rods 12 mm
LV Brass Bush Rods 19 mm
LV Brass Bush Rods 25 mm
LV Brass Bush Rods 32 mm
Press card board soft calendared solid 1mm/2mm/3mm(as per sample)
Press card board Pre compressed solid 1mm/2mm/3mm.
HT Insulating gum
Glass wool sleeves of sizes
Aluminium brazing Rod (Standard length)
Copper brazing Rod (Standard Length)
Flexible copper strip (Shim) 75mm x 0.5 mm
PVC sheets 1 mm thick
Empire tape 1''
Electrical Grade Kraft Paper, 4 mil
Leatheroid Insulation paper 20 mil.
HV bushing
LV Bushes suitable for 63 to 100 KVA DT
LV Bushes suitable for 200 to 250 KVA DT
LV Bushes suitable for 400 to 630 KVA DT
Epoxy Resin Cast 1.1 KV low voltage transformer bushing with Busbar for 400/630 KVA DT
Cotton tape 1'' (size) 35 m long.
Rubber washers
HT paper
Cork Washer 12mm dia
Cork Washer20mm dia
Cork Washer 25mm/30mm dia
Plastic Metre Seals
Petrol Chain Saw
Trifor (Tower Roller)
Pneumatic Air Impact Wrench with sockets from 15 to 30
Air Compressor 50 Ltr
Hand Held Brush Cutter
Webbing Slings lifting capacity upto 6 tonnes
Dee Shackles - 6 ton Capacity
Eye Bolt - M30
LED Search Light
Hydraulic Crimping Tool
Pallet Truck
Fire Extinguisher
Hand Driven Meggar
Multimeter(Analog)
Multimeter(Digital) Voltage: DC: 1000 volts; AC: 1000 volts; DC Accuracy: ± 0.5% + 3 digit; AC Accuracy: ± 1% + 3 digit; Current: DC: 10 amps; AC: 10 amps; DC Accuracy: ± 1.5% + 3 digit; AC Accuracy: ± 1.5% + 3 digit; Resistance: 40 M ohm; Resistance Accuracy: ± 1.5% + 3 digit ; Capacitance: 1000 μF; Capacitance Accuracy: ± 5% + 5 digit CAT III 600 volts safety rating
Pliers -Type of Hand Tool-Combination Plier as per IS 6149, Type of Insulation-Rubber Insulation, Material-Carbon Steel
Nawara tape 1'' (size) 35 m long.
Rubberized Cork sheet 4 mm thick 2ftx3ft
Rubberized Cork sheet 3mm thick 2ftx3ft
Bakelite tubes 12mm dia ( 1 mtr long)
HV Bush Clamps (MS)
Aluminium Clamping member (shoes) for HV Bushing
LV Cork washers 12 mm dia
LV Cork washers 20mm dia
LV Cork washers 25 mm/30 mm dia
Nuts & Bolts (M.S) of Sizes.
M.S Flat Washers.
HV Cork Washers 110 mm O.D
Aluminium welding flux
Aluminium flat 4/6/8/10 mm thick of required (Busbar)
Copper flat 4/6/8/10 mm thick of required width. (Busbar)
MS plug & caps 1/2'' ; 3/4''; /1''; 1.1/4''; 1.1/2''
Oil seal rings (O-rings) for LV/HV bush Rods 12 mm dia.
Oil seal rings (O.rings) for LV/HV bush rods 20 mm dia
Oil seal rings (O.rings) for LV/HV bush rods 25 mm dia
Creep tape 1''
Cotton cloth
Empire Sleeves of Sizes
Synthetic enamel paint smoke grey colour
Paint thinner
Steel Primer
Silica gel
Transformer Oil as per IS 335 and amendments thereof
Welding Rods 3.15 mm/4mm. (100 No. per Packet)
Refilling of oxygen gas for brazing
Refilling of LPG gas for brazing
12 Piece Tool Kit (1-Piece Screwdriver, 1-Piece Hammer, 7-Pieces Screwdriver Bits, 1-Piece Plier, 1-Piece Wrench(adjustib and 1-Piece Measuring Tape) BOSCH/DEWALT/TAPARIA
Clamp Meter, Conforms to IEC 61010, CAT II 600V safety rated, 600A AC current measurement, AC/DC voltage, resistance, continuity & data hold function, 2 years manufacturer warranty [FLUKE/DIGI SENSE/ MOTWANE/EXTECH]
12 Volts, 42 AH Lead Acid Battery
Battery Connector for 12 V Battery Bank (12 no. Both ends of each connector should be properly clamped with nuts, bolts, washers)
Fabricated GI Pollar Collar 50x6 mm with nuts and bolts
Digital Weighing Scale upto 1 Ton
Portable Professional Petrol Chainsaw,18 inch or above, 2 KW or above, Pitch of 3/8'' or above, Petrol capacity 400 Ml or above.
Double Ply Polyester Webbing Slings, Load Capacity 5 tonne
Dee Shackles Forged Shackles, Working Load 6.5 tonne
Eyebolt with recessed collar with maximum Axial Lifting Capacity of 6 tonne
HANDHELD BRUSH CUTTER / LINE TRIMMER, with Nylon feed head attachment Petrol Engine Low Vibration Centrifugal Clutch, Hardened Steel 2 teeth blade, Bump / Tap & go Type, Shaft Length (mm) 1425 to 1449, Circular Saw attachment inclusive in the scope of supply
Portable Hydraulic Crimping tool for 30 sqmm to 400 sqmm with all attachments
Pre fabricate galvanized single way top bracket (1000 mm long with 48.3 OD GI Pipe) to be fitted on top of Octogonal pole for holding lighting luminaries.
DK thermoplastic cable Junction/ Termination T boxes 8"x10"of class IP55/IP65 fitted with two 2-5 Amp MCB strip,4-way terminal block / connectors Incl. copper lugs, Clamps ,nut & bolts washers etc (Hansel or equivalent make) or poles with two way type bracket to be fitted properly inside the door opened gear box provided on thebottom side of the pole.
Surge Protector for the 120/190 watt LED type lighting fixture complete.
Dust/rain/snow-proof canopy type mini-outdoor LT feeder panel of size 450X300mm with front door opening duly powdered colour coated with inbuilt 2No TPN 16-32 Amp MCCB,TPN busbars of same capacity installed on cement concrete block with 4 angle iron legs grouted in the cement concrete of termination of main 25sqmm cable and outgoing 25/16 sqmm cable circuits.
120 Watt LED Luminaries of IP 67 protection.
190 Watt LED Luminaries of IP 67 protection.
110 W LED Light Fitting with >/= 100 Lm/Watt efficacy IP 67 Ingress Protection (IP Rating) as per IS:10322 (Part 1):1982 latest, 90 to 300 Volts AC at 50 Hz+/-2 Input voltage range, 230 V AC 50 Hz Rated Voltage, Poly carbonate lense, SMD LED Chip as per LM 80/IS16106, IP 66 Protection of the entire housing (both LED section and driver section) as per IS:10322 (Part 1):1982 latest
70W LED Light Fitting with >/= 100 Lm/Watt efficacy IP 67 Ingress Protection (IP Rating) as per IS:10322 (Part 1):1982 latest, 90 to 300 Volts AC at 50 Hz+/-2 Input voltage range, 230 V AC 50 Hz Rated Voltage, Poly carbonate lense, SMD LED Chip as per LM 80/IS16106, IP 66 Protection of the entire housing (both LED section and driver section) as per IS:10322 (Part 1):1982 latest
50 W LED Light Fitting with >/= 100 Lm/Watt efficacy IP 67 Ingress Protection (IP Rating) as per IS:10322 (Part 1):1982 latest, 90 to 300 Volts AC at 50 Hz+/-2 Input voltage range, 230 V AC 50 Hz Rated Voltage, Poly carbonate lense, SMD LED Chip as per LM 80/IS16106, IP 66 Protection of the entire housing (both LED section and driver section) as per IS:10322 (Part 1):1982 latest
30W LED Light Fitting with >/= 100 Lm/Watt efficacy IP 67 Ingress Protection (IP Rating) as per IS:10322 (Part 1):1982 latest, 90 to 300 Volts AC at 50 Hz+/-2 Input voltage range, 230 V AC 50 Hz Rated Voltage, Poly carbonate lense, SMD LED Chip as per LM 80/IS16106, IP 66 Protection of the entire housing (both LED section and driver section) as per IS:10322 (Part 1):1982 latest
6 A SP MCB, 10 KA Rated Short circuit capacity (Ampere), Instantaneous Tripping Range C, 1pole with 1PP, 240 V
10 A SP MCB, 10 KA Rated Short circuit capacity (Ampere), Instantaneous Tripping Range B, 1pole with 1PP, 240 V
10 A DP MCB, 10 KA Rated Short circuit capacity (Ampere), Instantaneous Tripping Range C, 2 pole with 2 PP, 240 V
16 A SP MCB, 10 KA Rated Short circuit capacity (Ampere), Instantaneous Tripping Range C, 1pole with 1PP, 240 V
16 A SPN MCB, 10 KA Rated Short circuit capacity (Ampere), Instantaneous Tripping Range C, 2pole with 1PP, 415 V
16 A TP MCB, 10 KA Rated Short circuit capacity (Ampere), Instantaneous Tripping Range C, 3pole with 3PP, 415 V
32 A TPN MCB, 10 KA Rated Short circuit capacity (Ampere), Instantaneous Tripping Range C, 4 pole with 3 PP, 415 V
32 A TP MCB, 10 KA Rated Short circuit capacity (Ampere), Instantaneous Tripping Range C, 3 pole with 3 PP, 415 V
32 A DP MCB, 10 KA Rated Short circuit capacity (Ampere), Instantaneous Tripping Range C, 2 pole with 2 PP, 415 V
32 A SP MCB, 10 KA Rated Short circuit capacity (Ampere), Instantaneous Tripping Range B, 1 pole with 1 PP, 415 V
63 A TPN MCB, 10 KA Rated Short circuit capacity (Ampere), Instantaneous Tripping Range C, 4 pole with 3 PP, 415 V
Astronomical Timer For Street Light Control, 3 Phase, 18 kW/43 A each phase, IP 66, Manually settable timer with 12 programmes spreaded over a year as defined programme, 260 Volt +/- 5 Volt Over Voltage Protection per phase, 160 Volt +/- 5 Volt Under Voltage Protection per phase, Operating Temperature Range -10 to +50 deg C, </=60 seconds ON/OFF Timing accuracy
Embossing Punch Die Tool for DT Coding (A-Z and 0-9)
Battery Operated Engraving Machine
Hand Operated Oil Pump/Barrel Pump
Manilla Rope - 25 mm
Nylon Rope- 20 mm
11kV Pilfer resistant metering cubicle for 3phase 4 wire metering system made of MS Sheet steel thickness not less than 2mm duly power coat painted suitable for indoor as well as outdoor as per the site requirement. The cubicle shall be painted through 7-tank process. The External dimensions should be adequate. Panel having two compartments upper Meter compartment and lower CT/PT compartment. Provided with synthetic or semi synthetic gasket firmly glued to the sufrace, Dust, weather and Vermin proof and shall comply degree of protection IP 65 both the chambers having one sided hinged door arrangments. The metering panel shall be provided with two No MS channels of size 100 x 50 mm on the front and rear sides duly welded and 4 No of lifting hooks. It should be possible to take meter reading manually, through CMRI and computer without opening the LV chamber door.
Single Phase, Single core, single ratio, Epoxy resin Cast Current Transformers suitable for 11kV, copper wound primary type with rated burden 5VA and accuracy class 0.5 or better and conforming to IS2705 (part-I & II) amended upto date. ISF shall be upto 5The CT ratio shall be 2.5 /5 for 25kVA DT
Single Phase, Single core, single ratio, Epoxy resin Cast Current Transformers suitable for 11kV, copper wound primary type with rated burden 5VA and accuracy class 0.5 or better and conforming to IS2705 (part-I & II) amended upto date. ISF shall be upto 5The CT ratio shall be 5/5 for 63kVA DT
Single Phase, Single core, single ratio, Epoxy resin Cast Current Transformers suitable for 11kV, copper wound primary type with rated burden 5VA and accuracy class 0.5 or better and conforming to IS2705 (part-I & II) amended upto date. ISF shall be upto 5The CT ratio shall be 7.5/5 for 100kVA DT
Single Phase, Single core, single ratio, Epoxy resin Cast Current Transformers suitable for 11kV, copper wound primary type with rated burden 5VA and accuracy class 0.5 or better and conforming to IS2705 (part-I & II) amended upto date. ISF shall be upto 5The CT ratio shall be 15/5 for 200kVA DT
Single Phase, Single core, single ratio, Epoxy resin Cast Current Transformers suitable for 11kV, copper wound primary type with rated burden 5VA and accuracy class 0.5 or better and conforming to IS2705 (part-I & II) amended upto date. ISF shall be upto 5The CT ratio shall be 20/5 for 250kVA DT
Single Phase, Single core, single ratio, Epoxy resin Cast Current Transformers suitable for 11kV, copper wound primary type with rated burden 5VA and accuracy class 0.5 or better and conforming to IS2705 (part-I & II) amended upto date. ISF shall be upto 5The CT ratio shall be 25/5 for 400 kVA DT
Single Phase, Single core, single ratio, Epoxy resin Cast Current Transformers suitable for 11kV, copper wound primary type with rated burden 5VA and accuracy class 0.5 or better and conforming to IS2705 (part-I & II) amended upto date. ISF shall be upto 5The CT ratio shall be 50/5 for 630 kVA DT
Single Phase, Single core, single ratio, Epoxy resin Cast Current Transformers suitable for 11kV, copper wound primary type with rated burden 5VA and accuracy class 0.5 or better and conforming to IS2705 (part-I & II) amended upto date. ISF shall be upto 5The CT ratio shall be 75/5 for 1 MVA DT
11kV/ 110 V, Three phase epoxy resin cast PT with rated burden 15VA per phase and accuracy class 0.5 or better and conforming to IS:3156 (part-I&II) amended upto date with proper colour coded identification. PTs shall be of uniform insulating and withstand separate source 23kV pf for one minute.
3Ph, 3 Wire HT CT/PT operated Fully static Smart Tri-Vector Energymeters DLMS CompliantCategory 'C' with RS232 port for modem compatibility. 11kV/110V, Ph-Ph (3P,3W) metersfor measurement of different electrical parameters including Active Energy (kWh/ MWh), Reactive Energy (kVArh/MVArh), Apparent Energy (kVAh/ MVAh) etc. (make L&T, Secure,ABB)
Pedestal made out of MS Channel of size 75 x 40 mm or angle iron of size 65 x 65 x 5 mm,duly painted as per site requirement for mounting of metering panel including concretefoundation wherever required including cost of nuts and bolts
M.I ENTERPRISES (BID ID -2361310)
M/S QADRI ELECTRICALS (BID ID -2361106)
UBAID SUPPLIERS AND CONTRACTORS (BID ID -2361074)
M/S EVEREST ENTERPRISES (BID ID -2361090)
M/S BILAL ELECTRICALS (BID ID -2360376)
AYMAN ELECTRIC SUPPLIERS (BID ID -2359800)
V-RIDGE ENGINEERING WORKS. (BID ID -2358448)
MIR IRFAN ELECTRICAL/SUPPLIERS (BID ID -2361085)
AYMAN ELECTRIC SUPPLIERS
M/S BILAL ELECTRICALS
M/S SHAKIBA ENTERPRISES
UBAID SUPPLIERS AND CONTRACTORS
MIR IRFAN ELECTRICAL/SUPPLIERS
M/S EVEREST ENTERPRISES
M/S QADRI ELECTRICALS
M.I ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .