Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical 171 GLOBEL SPACE HUDA GLOBEL SPACE COLONY 125055 | SIRSA | HARYANA | 125055 | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹3.1 Cr
EMD Value
₹17.3 L
Closing Date
25 Feb 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CHIEF ENGINEER
NNM
Work of upgradation of Ward-10 Kanha Gaushala (Partapur)
2026_NNMEE_1112584_1
8885/SNV-9T/2026
Open Tender
Civil Works
Fixed-rate
90 days
MEERUT
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,900
NAGAR AYUKT NAGAR NIGAM
₹17.3 L
25 Feb 2026
5 Feb 2026
25 Feb 2026
5 Feb 2026
25 Feb 2026
5 Feb 2026
BOUNDARY WALL Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. all kind of soil
Providing and laying of PCC 1:4:8 grade in foundation & pilnth with proper compecting.
Brick work with common burnt clay F.P.S. (non modular) bricks of class 150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying in position specified grade of reinforced cement concrete, including the cost of centering, shuttering, finishing and reinforcement - 1:1.5:3 (1 cement : 154 coarse sand (zone-ill) : 3 graded stone aggregate 20 mm in footing
in plinth beam
in Column upto plinth
Above Plinth Beam a) in Column
b) in Top Beam
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Providing & Laying of steel reinforcement i/c cutting, bending, placing and binding with wire complete.
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand FM not less then 1.25)
15 mm cement plaster on rough side of single or half brick wall of mix (1cement :6 fine sand FM not less then 1.25)
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. Making groove 10 to 12 mm wide x 8 mm deep in plaster of wall or in ceiling vertically or horizontally as required.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 kg/ 10 sqm)
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or 6 nos of G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Providing and fixing in position Stainless steel Grade 304 plate-1.0 mm thick as per design for expansion joints 200 mm wide
GATE Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Bada Fencing Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer- Incharge. ( All Kind Of Soil )
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete Electric resistance or induction butt welded tubes
(GUARD ROOM) CIVIL WORK Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the coloumn pitswall tench basement excavation top surface if plinth filling junction of wall and floor along the external perimer of binding expansion joints,surrounding of pipes and conduits etc.complete(plinth area of the building at ground floor only shall be measured as per I.S.6313(Part ll 1981) aldrine emulsifiable concrete or any other approved material such as hepthachlor or chlordance will be used.The rate of application of chemical emulsion shall be as follows:- (1) treatment for masonary & foundation 5 litres per sq.m. (2) back fill in immediate contract with foundation 7.5 litre per sq.m (3)treatment of top surface of plinth filling 5 liters per sq.m. (4) treatment of soil along external parameter of building 7.50 lire per sq.m.
Providing and laying of PCC 1:4:8 grade in foundation & pilnth with proper compecting.
Foundations, footings, bases of columns, etc. for mass concrete
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position machine batched and machine mixed design mix M 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). in foundation/ below plinth upto plinth level
above plinth
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike- plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge (E profile)
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300x10mm
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 35mm th Second class teak wood
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete Electric resistance or induction butt welded tubes
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 5.5 mm thick glass panes
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete.
P/appying of Plaster on ceiling in 1:3 cement C.sand mix mortor complete.
P/appying of 12 mm th. Plaster on wall inside in 1:6 cement C.sand mix mortor complete.
P/Appying of 15 mm th Plaster on wall outside in 1:6 cement C.sand mix mortor complete.
P/Appying of 15 mm th Plaster on wall below plinth in 1:4 cement C.sand mix mortor complete.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :
P/Applying of water proof cement paint of approved quality on new work with final coat to give an shade i/c all tools & plants complete
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm dia
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee with Door
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Brick edgeing 7cm wide 11.4cm deep to plinth proection with bricks of class designation 75 i/c grouting with cement mortor 1:4 mix.
SANITARY WORK: (GUARD ROOM) Providing and fixing of 100mm dia 6Kg pressure PVC Pipe for soil, waste and vent pipe.inclusive of socket & snecessary fittings
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc (i) 15 mm dia pipe
ii) 20 mm dia pipe
Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 15 mm nominal bore, 105 mm long, weighing not less than 138 gms (i) 15 mm dia
Providing and fixing PTMT bib cock of approved quality and colour 15mm nominal bore, 86 mm long, weighing not less than 88 gms
125 mm grating with waste hole
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-White Vitreous China Wash basin size 550x400 mm with 15 mm CP Brass single hole basin mixer
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 (15mm nominal bore)
OFFICE Bulding Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer- Incharge. ( All Kind Of Soil )
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the coloumn pitswall tench basement excavation top surface if plinth filling junction of wall and floor along the external perimer of binding expansion joints,surrounding of pipes and conduits etc.complete(plinth area of the building at ground floor only shall be measured as per I.S.6313(Part ll 1981) aldrine emulsifiable concrete or any other approved material such as hepthachlor or chlordance will be used.The rate of application of chemical emulsion shall be as follows:- (1) treatment for masonary & foundation 5 litres per sq.m. (2) back fill in immediate contract with foundation 7.5 litre per sq.m (3)treatment of top surface of plinth filling 5 liters per sq.m. (4) treatment of soil along external parameter of building 7.50 lire per sq.m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum
All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth & above Plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. cement mortar 1:4 (1 cement : 4 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 125x75x4 mm
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete Twin rubber stopper
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
Providing and fixing to existing door frames. 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and laying tactile tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Providing and laying machine cut, mirror polished Marble stone flooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. a. 18 mm thick Italian Marble stone slab,Perlato, Rosso verona, Fire Red or Dark Emperadore etc.
Providing edge moulding to 18 mm thich marble stone counters , vanities etc. including machine polishing to edge to give high glass finish etc. complete as per design approved by Engineer -in Incharge. Granite work
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 100 mm
Single tee with door 100 mm
Bend 87.5° 100mm Bend
Shoe (Plain) 100 mm Shoe
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix
15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 coarse sand)
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 kg/ 10 sqm)
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and laying "brick coba" 12 mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15 mm to each other, over 20 mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with aerelic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finfished smooth & top mashed false square 30 x 30 cm and side wall parapet shall be monotythic plaster wall upto 30 cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonary coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour, T&P etc complete for proper completion of work.
Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540- F & ISO 11600 Upto 20 mm depth and 20 mm width
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge Pre-laminated particle board with decorative lamination on both sides
C/O Apron drain of width 150 mm and depth as per required of site but minimum 150 mm with neat finish & required slope as per apporoved by E/I.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Brick edging 7cm wide 11.4cm. deep to plinth protection with bricks of class designation 75 including grouting with cement mortar 1:4 (1 cement : 4 fine sand)
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece
SANITARY WORK & EXTERNAL CONNECTION WORK: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan.
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia
Providing and fixing 100 mm sand cast Iron grating for gully trap
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing toilet paper holder : C.P. brass
Providing and fixing soil, waste and vent pipes : 100mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : 100mm dia
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 100mm dia pipe
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 mm dia Sand cast iron S&S as per IS - 3989
Providing and fixing plain bend of required degree. 100mm dia Sand cast iron S&S as per IS : 3989
Providing and fixing heel rest sanitary bend 100mm dia Sand cast iron S&S as per IS - 3989
Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete : 100x100x100x100 mm Sand cast iron S&S as per IS - 1729
Providing and fixing sand cast iron S&S off sets as per IS: 3989 : 150 mm off sets With 100 mm dia pipe
Providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 100mm dia Sand cast iron S&S as per IS - 3989
Providing and fixing terminal guard : 100 mm Sand cast iron S&S as per IS - 3989
Providing and fixing collar : 100mm Sand cast iron S&S as per IS - 3989
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 100mm
Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter (100mm)
Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 100mm dia
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes
20 mm nominal dia Pipes
25 mm nominal dia Pipes
32 mm nominal dia Pipes
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Exposed on wall 50 mm dia nominal bore
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore
Providing and fixing brass bib cock of approved quality 20 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm dia nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal dia Pipes
Providing and fixing uplasticised PVC connection pipe with brass unions 45 cm length 15mm nominal bore
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work 50mm diameter pipe
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 50mm diameter pipe
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 50 mm dia nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 150 mm diameter S.W. pipe
250 mm diameter S.W. pipe
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 150 x 100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm diameter RCC. pipe
250 mm diameter RCC pipe
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes : Size 90x80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Size 120x90 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
(BHUSA STORE) Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m, All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil
Sand Filling in plinth i/c supply of necessary quantity of sand from a distance not exceeding 8 Km from the site of work and i/c watering dressing etc.
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the coloumn pitswall tench basement excavation top surface if plinth filling junction of wall and floor along the external perimer of binding expansion joints,surrounding of pipes and conduits etc.complete(plinth area of the building at ground floor only shall be measured as per I.S.6313(Part ll 1981) aldrine emulsifiable concrete or any other approved material such as hepthachlor or chlordance will be used.The rate of application of chemical emulsion shall be as follows:- (1) treatment for masonary & foundation 5 litres per sq.m. (2) back fill in immediate contract with foundation 7.5 litre per sq.m (3)treatment of top surface of plinth filling 5 liters per sq.m. (4) treatment of soil along external parameter of building 7.50 lire per sq.m.
Providing and laying of PCC 1:4:8 grade in foundation & pilnth with proper compecting.
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil
Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level, Thermo-Mechanically Treated bars of grade Fe-500D or more
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). All work upto plinth level
Above Plinth level
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 1 : 6 Cement Mortar
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 1:6 cement mortar
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete Hot finished welded type tubes
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Ridges plain (500 - 600mm)
Gutter (600 mm over all girth)
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cove
Providing and fixing ball bearing for rolling shutters.
40mm th. Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
18mm th Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.
P/appying of 12 mm th. Plaster on wall inside in 1:6 cement C.sand mix mortor complete.
P & A of 15 mm cement plaster on rough side of single or half brick wall of mix1:4 (1 1:6 (1 cement: 6 coarse sand)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing walls with water proofing cement paint of required shade New work (Two or more coats applied @ 3.84 kg/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm dia
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee with door (110x110x110 mm)
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
SANITARY WORK: (FEEDING STORE) Providing and fixing of 100mm dia 6Kg pressure PVC Pipe for soil, waste and vent pipe.inclusive of socket & snecessary fittings
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :
P/Fixing of Square mouth SW Gully trap class SP-1 complete with CI grating brick masonary chamber with water tight C.I. Cover with frame of 300x300mm size (inside) the wt of cover to be not less than 4.50 kg and frame to be not less then 2.70 kg as per standard design with sewer brick conforming to IS: 4885.
P/Laying of Non Pressure NP2 pipe class light duty RCC pipe with coller jointed with stiff mixture of cement in proportion of 1:2 cement and sand including testing of joint etc for 150 mm dia
Excavating trenches of required width for sewer line or drain line, pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
Constructing sewer brick IS 4885 manhole in cement mortar 1:4 cement & coarse sand with RCC top slab in 1:2:4 mix and base PCC 1:4:8 mix, including inside plastering in 1:3 cement coarse sand finish with floting coat of cement and making channels in cement concrete finishing with a flosting coat of cement complete. Insde size 90x80x45cm including CI cover with frame light duty.
Staff Residence Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. all kind of soil
Sand Filling in plinth i/c supply of necessary quantity of sand from a distance not exceeding 8 Km from the site of work and i/c watering dressing etc.
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the coloumn pitswall tench basement excavation top surface if plinth filling junction of wall and floor along the external perimer of binding expansion joints,surrounding of pipes and conduits etc.complete(plinth area of the building at ground floor only shall be measured as per I.S.6313(Part ll 1981) aldrine emulsifiable concrete or any other approved material such as hepthachlor or chlordance will be used.The rate of application of chemical emulsion shall be as follows:- (1) treatment for masonary & foundation 5 litres per sq.m. (2) back fill in immediate contract with foundation 7.5 litre per sq.m (3)treatment of top surface of plinth filling 5 liters per sq.m. (4) treatment of soil along external parameter of building 7.50 lire per sq.m.
Providing and laying of PCC 1:4:8 grade in foundation & pilnth with proper compecting.
Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position machine batched and machine mixed design mix M 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). in foundation/ below plinth upto plinth level
above plinth
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. (cement mortar 1:4 (1 cement : 4 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike- plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge (E profile)
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300x10mm
Providing and fixing aluminium 125mm handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete Electric resistance or induction butt welded tubes
Providing and fixing ISI marked oxidised M.S. tower bolts with nuts and screws etc. complete : 150x10mm
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125mm
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 5.5 mm thick glass panes
Providing and fixing MS hand rail & grill of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand)
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, pproved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Raj Nagar Plain white marble/ Udaipur green marble
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (40 mm thick with 20 mm nominal size stone aggregate)
18mm th. Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.
P/appying of Plaster on ceiling in 1:3 cement C.sand mix mortor complete.
P/appying of 12 mm th. Plaster on wall inside in 1:6 cement C.sand mix mortor complete.
P/Appying of 15 mm th Plaster on wall outside in 1:6 cement C.sand mix mortor complete.
P/Appying of 15 mm th Plaster on wall below plinth in 1:4 cement C.sand mix mortor complete.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixedb slurry.
Providing and laying brick tiles over roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat: With common burnt clay F.P.S. (non modular) brick tiles of class designation 10
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
P/Applying of water proof cement paint of approved quality on new work with final coat to give an shade i/c all tools & plants complete, New work (Two or more coats applied @ 3.84 kg/10 sqm)
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm dia
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee with Door
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Brick edgeing 7cm wide 11.4cm deep to plinth proection with bricks of class designation 75 i/c grouting with cement mortor 1:4 mix.
SANITARY WORK: (Staff Residence) Providing and fixing of 100mm dia 6Kg pressure PVC Pipe for soil, waste and vent pipe.inclusive of socket & snecessary fittings
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :
P/Fixing of Square mouth SW Gully trap class SP-1 complete with CI grating brick masonary chamber with water tight C.I. Cover with frame of 300x300mm size (inside) the wt of cover to be not less than 4.50 kg and frame to be not less then 2.70 kg as per standard design with sewer brick conforming to IS: 4885.
P/Laying of Non Pressure NP2 pipe class light duty RCC pipe with coller jointed with stiff mixture of cement in proportion of 1:2 cement and sand including testing of joint etc for 150 mm dia
Excavating trenches of required width for sewer line or drain line, pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
Constructing sewer brick IS 4885 manhole in cement mortar 1:4 cement & coarse sand with RCC top slab in 1:2:4 mix and base PCC 1:4:8 mix, including inside plastering in 1:3 cement coarse sand finish with floting coat of cement and making channels in cement concrete finishing with a flosting coat of cement complete. Insde size 90x80x45cm including CI cover with frame light duty.
Extra for depth for manholes : Size 90x80 cm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc (i) 15 mm dia pipe
ii) 20 mm dia pipe
Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 15 mm nominal bore, 105 mm long, weighing not less than 138 gms (i) 15 mm dia
P.T.M.T. extension nipple 20 mm dia
Fixture: Providing and fixing PTMT bib cock of approved quality and colour 15mm nominal bore, 86 mm long, weighing not less than 88 gms
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 (15mm nominal bore)
125 mm grating with waste hole
Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan.
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-White Vitreous China Wash basin size 550x400 mm with 15 mm CP Brass single hole basin mixer
Providing and fixing white vitreous china pedestal type water closet European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
SHED AREA: Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
linth in: Cement mortar 1:6 coarse sand.ÕReinforced cement concrete work in slab (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) In SlabCentering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platformWCement plaster (1:3) finished with a floating coat of neat cement. 20 mm Cement PlasterËProviding M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars.EProviding and fixing C.I. tee at the inlet and outlet of septic tank.'Providing & fixing 75mm dia vent pipes.8Providing & fixing of 75mm dia cast iron terminal guard. Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. HD . -20- Circular shape 560mm internal diameterÌMaking soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.Z (ELECTRICAL WORK) Office building Wiring for light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C'%174Wiring for fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C :Wiring for exhaust fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C < Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.|Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. æSupplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.òSupplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.~Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as requiredZSupply and fixing of call bell/ buzzer suitable for single phase 230V complete as requiredûSupply and fixing of following sizes of medium class PVC conduit along with accessoreis in surfcae/ recess including painting in case of surface conduit or cutting the wall and making good the same in case of recessed conduit as required. 20 mm dia 25 mm dia 32mm diaSupplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.e"0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy e"120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness e" 1.20 mm) 36 Watt<Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.e"0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker sh
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth & above Plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
uld be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. "complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). LED Down lighter (SMD Type) (System lumen efficacy > 135 lm/Watt ) 18 wattJ䰀䑅䐠睯楬桧整匨䑍吠灹⥥⠠祓瑳浥氠浵湥攠晦捩捡⁹‾㌱‵浬圯瑡⁴ 〳眠瑡쵴ःSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, WITHOUT REMOTE class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)DzŹ倀潲楶楤杮愠摮映硩湩楣捲汵牡 敨慸潧慮⹇⹉䈠硯映牯挠楥楬杮映湡挠慬灭漠湩整湲楤㐱‰浭㜠″浭栠杩瑨琠灯氠摩漠⸱‵浭琠楨正䜠䤮匠敨瑥眠瑩瑩潴⁰畳晲捡慨正摥映牯瀠潲数潢摮湩潴⁰楬桳污敢猠牣睥摥椠瑮桴⹇⹉䈠硯戠⁹敭湡景㌠㌮洠楤潲湵敨摡摥猠牣睥湯潬歯愠⁴桴潣湲牥䌠慬灭桳污敢洠摡景ㄠ洲楤⹍⁓慂敢瑮琠桳灡獡瀠敷猠慴摮牡牤睡湩²匀灵汰楹杮愠摮映硩湩睴潭畤敬猠整灰摥琠灹汥捥牴湯捩映湡爠来汵瑡牯漠桴硥獩楴杮洠摯汵牡瀠慬整猠楷捴潢⁸湩汣摵湩潣湮捥楴湯畢⁴硥汣摵湩潭畤慬汰瑡瑥愠敲畱物摥ᴮ湉瑳污慬楴湯整瑳湩湡潣浭獩楳湯湩景挠楥楬杮映湡湩汣摵湩楷楲杮琠敨搠睯潲獤漠瑳湡慤摲氠湥瑧用瑰〳挠⥭眠瑩⸱‵煳浭䘠䱒⁓噐⁃湩畳慬整Ɽ挠灯数潣摮捵潴Ⱳ猠湩汧潣敲挠扡敬湩汣摵湩牰癯摩湩湡楦楸杮瀠敨潮楬慬業慮整桳敥⁴潣敶湯琠敨映湡戠硯攠捴獡爠煥極敲끤畓灰祬漠䍁㈠〳㈯〵嘠汯獴〵䠠⁺硥慨獵⁴慦獮椠据畬楤杮瀠潲楶楤杮渠瑵ⱳ戠汯獴潭湵楴杮映慲敭愠摮漠桴牥愠捣獥潳楲獥椠据畬楤杮挠湯敮瑣潩獮攠捴潣灭敬整愠敲畱物〳洰睳敥¾匀灵汰⁹…楆楸杮漠〴洰睳敥Ɒ眠污潭湵整慦潣灭敬整眠瑩潤扵敬戠污敢牡湩Ⱨ洠瑯牯汢摡獥慣慰楣潴瑥畳瑩扡敬映牯猠湩汧桰獡㌲‰潶瑬ⱳ㔠‰穈Ⱞ䄠⁃畳灰祬潣灭敬整愠敲畱物摥ꐮ湉瑳污慬楴湯漠硥慨獵⁴慦湩琠敨攠楸瑳湩灯湥湩Ⱨ椠据畬楤杮洠歡湩潧摯琠敨搠浡条ⱥ挠湯敮瑣潩Ɱ琠獥楴杮潣浭獩楳湯湩瑥愠敲畱物摥⸱〵ㄮ唠瑰㔴‰浭猠敷灥 匀灵汰⁹湡楦楸杮漠㘱匠䝗䴠匮牤浵眠瑩畬敶獲搠汵⁹慰湩整湩汣摵湩慭楫杮栠汯湩琠敨眠污潦硥慨獵⁴慦湡楦楮桳湩牰灯牥祬挠浯汰瑥湩愠汬爠獥数瑣楗楲杮映牯挠物畣瑩 畳浢楡楷楲杮愠潬杮楷桴攠牡桴眠物楷桴琠敨映汯潬楷杮猠穩獥漠剆卌倠䍖椠獮汵瑡摥挠灯数潣摮捵潴Ⱳ猠湩汧潣敲挠扡敬椠畳晲捡⽥爠捥獥敳敭楤浵挠慬獳倠䍖挠湯畤瑩愠敲畱物摥††††㈠堠ㄠ㔮猠浱ㄫ堠ㄠ㔮猠浱慥瑲楷敲+ ′⁘⸲‵煳浭⬠ㄠ堠㈠㔮猠洠慥瑲楷敲&㈀堠㐠猠洠‱⁘‴煳浭攠牡桴眠物♥′⁘‶煳浭⬠ㄠ堠㘠猠洠慥瑲楷敲&㐀堠㘠猠洠′⁘‶煳浭攠牡桴眠物❥‴⁘〱猠洠′⁘‶煳浭攠牡桴眠物❥‴⁘㘱猠洠′⁘‶煳浭攠牡桴眠物慅瑲楨杮眠瑩⹇攠牡桴瀠慬整㘠〰洠⁘〶‰浭堠㘠洠桴捩湩汣摵湩捡散獳牯敩ⱳ愠摮瀠潲楶楤杮洠獡湯祲攠据潬畳敲眠瑩潣敶汰瑡慨楶杮氠捯楫杮愠牲湡敧敭瑮愠摮眠瑡牥湩楰数漠⸲‷敭牴潬杮攠捴楷桴挠慨捲慯⽬挠歯湡慳瑬愠敲畱物摥ô䔀牡桴湩楷桴挠灯数慥瑲汰瑡〶‰浭堠㘠〰洠⁘″浭琠楨正椠据畬楤杮愠捣獥潳楲獥湡牰癯摩湩慭潳牮⁹湥汣獯牵楷桴挠癯牥瀠慬整栠癡湩潬正湩牡慲杮浥湥⁴湡慷整楲杮瀠灩景㈠㜮洠瑥敲氠湯瑥眠瑩档牡潣污 潣敫愠摮猠污⁴獡爠煥極敲ꤠ畓灰祬湩湡慬楹杮㘠匠䝗䜠氮楷敲愠⁴⸰〵洠瑥敲戠汥睯朠潲湵敬敶潦潣摮捵潴慥瑲汥捥牴摯ⱥ椠据畬楤杮挠湯敮瑣潩⽮琠牥業慮楴湯眠瑩汇琠楨扭敬攠捴獡爠煥極敲†畓灰祬湩湡慬楹杮㈠‵浭堠㔠洠潣灰牥猠牴灩愠⁴⸰〵洠瑥敲戠汥睯朠潲湵獡猠牴灩攠牡桴攠敬瑣潲敤湩汣摵湩潣湮捥楴湯 整浲湩瑡湩楷桴渠瑵潢瑬灳楲杮慷桳牥攠捴獡爠煥極敲⠠潊湩楴杮猠慨汬戠潤敮戠⁹癯牥慬灰湩湡楷桴㈠猠瑥景戠慲獳渠瑵戠汯⁴…灳楲杮眠獡敨灳捡摥愠⁴〵浭 Ģ匀灵汰楹杮愠摮氠祡湩㔲洠⁘‵浭䜠氮瑳楲⁰瑡〠㔮‰敭牴敢潬⁷牧畯摮愠瑳楲⁰慥瑲汥捥牴摯ⱥ椠据畬楤杮挠湯敮瑣潩⽮琠牥業慮楴杮眠瑩⹇渠瑵潢瑬灳楲杮慷桳牥攠捴獡爠煥極敲⠠潊湩楴杮猠慨汬戠潤敮戠⁹癯牥慬灰湩湡楷桴㈠猠瑥景䜠氮畮⁴潢瑬☠猠牰湩慷桳牥猠慰散瑡㔠洰⥭椠牐癯摩湩湡楦楸杮㈠‵浭堠㔠洠潣灰牥猠牴灩漠畳晲捡牯椠敲散獳映牯挠湯敮瑣潩獮攠捴獡爠煥極敲朠牐癯摩湩湡楦楸杮㈠‵浭堠㔠洠⹇猠牴灩漠畳晲捡牯椠敲散獳映牯挠湯敮瑣潩獮攠捴獡爠煥極敲怠牐癯摩湩湡楦楸杮㘠匠䝗搠慩䜠氮楷敲漠畳晲捡牯椠敲散獳映牯氠潯⁰慥瑲楨杮愠敲畱物摥ķ匀灵汰楹杮愠摮
Columns, Pillars, Piers, Abutments, Posts and Struts
fixing 4 way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)7Supplying and fixing 6 way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)¬Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door ùSupplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, C curve,SP miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. ZSupply & fixing single pole blanking plate in the existing MCB DB complete etc as requiredûProviding and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A 30 KA FPMCCB 125 A 36 KA FPMCCB ;Supply and fixing of 40 Amp. FP MCB (10 KA) C Curve. CAT A6:Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A5:Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A5:Supply and fixing of 63 Amp. TP MCB (10 KA) C Curve. CAT A5Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 10 sq mm x 4 core35 sq.mm 3½ core50 sq mm x 3-1/2coreØSupplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm3½ X 35 sq. mm ` (ELECTRICAL WORK) Bhusa Store Wiring for light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C'!7=%Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.e"0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy e"120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness e" 1.20 mm) 36 WattLSupplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.e"0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. "complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). LED Down lighter (SMD Type) (System lumen efficacy > 135 lm/Watt ) 18 wattΡȉ匀甀瀀瀀氀礀Ⰰ 䤀渀猀琀愀氀氀愀琀椀漀渀Ⰰ 吀攀猀琀椀渀最 愀渀搀 䌀漀洀洀椀猀猀椀漀渀椀渀最 漀昀 挀攀椀氀椀渀最 昀愀渀 眀椀琀栀 䈀爀甀猀栀 䰀攀猀猀 䐀椀爀攀挀琀 䌀甀爀爀攀渀琀 ⠀䈀䰀䐀䌀⤀ 䴀漀琀漀爀Ⰰ 圀䤀吀䠀伀唀吀 刀䔀䴀伀吀䔀 挀氀愀猀猀 漀昀 椀渀猀甀氀愀琀椀漀渀㨀 䈀Ⰰ ㌀ 渀漀猀⸀ 洀攀琀愀氀 ⠀䄀氀甀洀椀渀甀洀 愀氀氀漀礀⤀ 戀氀愀搀攀猀Ⰰ ㌀ 挀洀 氀漀渀最 搀漀眀渀 爀漀搀Ⰰ ㈀ 渀漀猀⸀ 挀愀渀漀瀀椀攀猀Ⰰ 猀栀愀挀欀氀攀 欀椀琀Ⰰ 猀愀昀攀琀礀 爀漀瀀攀Ⰰ 挀漀瀀瀀攀爀 眀椀渀搀椀渀最Ⰰ 猀琀攀攀氀⼀䄀氀 戀漀搀礀 倀漀眀攀爀 䘀愀挀琀漀爀 渀漀琀 氀攀猀猀 琀栀愀渀 ⸀㤀Ⰰ 匀攀爀瘀椀挀攀 嘀愀氀甀攀 ⠀䌀䴀⼀䴀⼀圀⤀ 洀椀渀椀洀甀洀 愀猀 戀攀氀漀眀Ⰰ ㌀㔀 刀倀䴀 ⠀琀漀氀攀爀愀渀挀攀 愀猀 瀀攀爀 䤀匀 㨀 ㌀㜀㐀ⴀ㈀ 㤀⤀Ⰰ 吀䠀䐀 ⠀吀漀琀愀氀 䠀愀爀洀漀渀椀挀 䐀椀猀琀漀爀琀椀漀渀⤀ 氀攀猀猀 琀栀愀渀 ─Ⰰ 爀攀洀漀琀攀 ⠀瀀爀攀昀攀爀愀戀氀礀 洀漀戀椀氀攀 愀瀀瀀 戀愀猀攀搀⤀ 昀漀爀 猀瀀攀攀搀 挀漀渀琀爀漀氀 愀渀搀 愀氀氀 爀攀洀愀椀渀椀渀最 愀挀挀攀猀猀漀爀椀攀猀 椀渀挀氀甀搀椀渀最 猀愀昀攀琀礀 瀀椀渀Ⰰ 渀甀琀 戀漀氀琀猀Ⰰ 眀愀猀栀攀爀猀Ⰰ 琀攀洀瀀攀爀愀琀甀爀攀 爀椀猀攀㴀㜀㔀 搀攀最爀攀攀 䌀 ⠀洀愀砀⸀⤀Ⰰ 椀渀猀甀氀愀琀椀漀渀 爀攀猀椀猀琀愀渀挀攀 洀漀爀攀 琀栀愀渀 ㈀ 洀攀最愀 漀栀洀Ⰰ 猀甀椀琀愀戀氀攀 昀漀爀 ㈀㌀ 嘀Ⰰ 㔀 䠀稀Ⰰ 猀椀渀最氀攀 瀀栀愀猀攀 䄀䌀 䌀攀椀氀椀渀最 䘀愀渀 挀漀洀瀀氀椀愀渀琀 琀漀 䤀匀 ㌀㜀㐀㨀㈀ 㤀 昀愀渀 匀甀瀀瀀氀礀Ⰰ 攀愀爀琀栀椀渀最 攀琀挀⸀ 挀漀洀瀀氀攀琀攀 愀猀 爀攀焀 ㈀ 洀洀Ⰰ 猀攀爀瘀椀挀攀 瘀愀氀甀攀 攀•㘀⸀ 䌀䴀⼀䴀椀渀⼀圀愀琀琀Ⰰ 愀椀爀 搀攀氀椀瘀攀爀礀 ㈀ 䌀䴀⼀䴀椀渀 ⠀䴀椀渀椀洀甀洀⤀䐀ᴀ稀ᬀ넀畓灰祬漠䍁㈠〳㈯〵嘠汯獴〵䠠⁺硥慨獵⁴慦獮椠据畬楤杮瀠潲楶楤杮渠瑵ⱳ戠汯獴潭湵楴杮映慲敭愠摮漠桴牥愠捣獥潳楲獥椠据畬楤杮挠湯敮瑣潩獮攠捴潣灭敬整愠敲畱物摥㌠〰浭猠敷灥┮′⁘⸱‵煳浭⬠‱⁘⸱‵煳浭攠牡桴眠物ꥥࠁ畓灰祬湩湡楦楸杮漠潦汬睯湩慷獹猠牵慦散 敲散獳洠畯瑮湩Ⱨ瘠牥楴慣祴数ㄴ‵ⱖ吠乐䴠䉃搠獩牴扩瑵潩潢牡景猠敨瑥猠整汥畤瑳瀠潲整瑣摥畤祬瀠睯敤慰湩整Ɽ椠据畬楳敶漠〲‰⁁楴湮摥挠灯数畢慢Ⱳ挠浯潭敮瑵慲楬歮慥瑲慢Ⱳ搠湩戠牡映牯洠畯瑮湩䍍獂⠠畢⁴楷桴畯⁴䍍獂愠摮椠据浯牥 獡爠煥極敲丨瑯›敖瑲捩污琠灹䍍⁂偔䉄椠潮浲污祬甠敳桷牥″桰獡畯汴瑥牡敲畱物摥⤮㐠眠祡⠠‴㈱Ⱙ䐠畯汢潤牯贠ᴁ᠀畓灰祬†湡氠祡湩漠污浵湩畩挠湯畤瑣牯†噐⁃椠獮汵瑡摥愠浲畯敲敳癲摥猠敨瑡敨慣汢獥ㄠ〱‰潖瑬牧摡瑡愠搠灥桴漠㔷‰浭戠汥睯朠潲湵敬敶癯牥愠挠獵楨湯漠㔷洠琠楨正猠湡污牡畯摮愠摮瀠潲整瑣摥眠瑩畢湲⁴牢捩獫漠楳敤湡湯琠灯湏猠牵慦散琠敨挠扡敬爠湵猠慨汬戠楦數湯䴠匮汣浡獰攠捴景猠極慴汢楳敺漠獡搠物捥整祢琠敨䔠杮湩敥湉档牡敧潣灭敬整椠污敲灳捥吠敨愠浲畯楲杮漠桴慣汢桳污敢瀠潲数汲⁹潣湮捥整楷桴琠敨攠牡桴挠湯畤瑣牯戠⁹汣浡獰攠捴†††††††††††††††ㄠ‰煳洠⁸‴潣敲ŔЈ 䔨䕌呃䥒䅃⁌佗䭒 畇牡潒浯†圠物湩潦楬桧⁴潰湩⁴楷桴ㄠ㔮猠浭䘠䱒⁓噐⁃湩畳慬整潣灰牥挠湯畤瑣牯猠湩汧潣敲挠扡敬椠畳晲捡 敲散獳摥洠摥畩汣獡噐⁃潣摮極ⱴ眠瑩潭畤慬睳瑩档潭畤慬汰瑡ⱥ猠極慴汢䥇戠硯愠摮攠牡桴湩桴潰湩⁴楷桴ㄠ㔮猠浭剆卌倠䍖椠獮汵瑡摥挠灯数潣摮捵潴楳杮敬挠牯慣汢瑥獡爠煥極敲片畯⁰C✀Ḁᬀ⬀ᴀᬀᤀआSupplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) 36 Wattؗڥ匁甀瀀瀀氀礀椀渀最Ⰰ 椀渀猀琀愀氀氀愀琀椀漀渀Ⰰ 吀攀猀琀椀渀最 ☀ 䌀漀洀洀椀猀猀椀漀渀椀渀最 漀昀 䰀䔀䐀 刀攀挀攀猀猀攀搀 ⼀ 猀甀爀昀愀挀攀 䐀漀眀渀 氀椀最栀琀攀爀 ⠀刀漀甀渀搀 ⼀ 猀焀甀愀爀攀⼀ 刀攀挀琀愀渀最甀氀愀爀⤀ 匀䴀䐀 琀礀瀀攀 漀昀 昀漀氀氀漀眀椀渀最 戀漀搀礀 洀愀琀攀爀椀愀氀 眀椀琀栀 倀䴀䴀䄀 愀渀搀 瀀爀椀猀洀愀琀椀挀 搀椀昀昀甀猀攀爀 愀渀搀 挀漀渀猀琀爀甀挀琀椀漀渀 愀猀 瀀攀爀 䤀匀 㨀 ㌀㈀㈀ 眀椀琀栀 搀爀椀瘀攀爀 愀猀 瀀攀爀 琀栀攀 爀攀焀甀椀爀攀洀攀渀琀 眀椀琀栀 䐀爀椀瘀攀爀 攀昀昀椀挀椀攀渀挀礀 㸀㠀㔀─Ⰰ 伀瀀攀爀愀琀椀渀最 瘀漀氀琀愀最攀 䄀䌀 㐀 ⴀ㈀㜀 嘀漀氀琀Ⰰ 昀爀攀焀 㔀 ⼀㘀 栀稀Ⰰ 伀瀀攀爀愀琀椀渀最 琀攀洀瀀 爀愀渀最攀 ⴀ㔀 搀攀最 琀漀 㐀 搀攀最 挀攀渀琀椀最爀愀搀攀Ⰰ 椀渀琀攀爀渀愀氀 猀甀爀最攀 瀀爀漀琀攀挀琀椀漀渀 漀昀 ㈀⸀㔀 䬀嘀 眀椀琀栀 匀栀漀爀琀 ☀ 伀瀀攀渀 挀椀爀挀甀椀琀 瀀爀漀琀攀挀琀椀漀渀 Ⰰ吀䠀䐀 㰀 ─ Ⰰ 倀⸀ 䘀⸀攀〢⸀㤀㔀Ⰰ 䤀倀㈀ Ⰰ 䌀刀䤀 㸀㠀 Ⰰ 唀䜀刀 ⠀唀渀椀昀椀攀搀 䜀氀愀爀攀 刀愀琀椀渀最⤀ 㰀 㤀Ⰰ 䘀氀椀挀欀攀爀 昀爀攀攀 ⠀昀氀椀挀欀攀爀 猀栀漀甀氀搀 戀攀 戀攀氀漀眀 㔀 ─⤀Ⰰ 氀椀昀攀 琀椀洀攀 ⠀䰀䔀䐀Ⰰ䐀爀椀瘀攀爀 ☀ 攀氀攀挀琀爀椀挀愀氀 挀椀爀挀甀椀琀爀礀⤀Ⰰ 氀椀昀攀 琀椀洀攀 漀昀 洀椀渀椀洀甀洀 㔀 䈀甀爀渀椀渀最 䠀漀甀爀猀 眀椀琀栀 Ⰰ 㜀 ─ 漀昀 椀渀椀琀椀愀氀 䰀甀洀攀渀 洀愀椀渀琀愀椀渀攀搀 琀椀氀氀 氀椀昀攀 攀渀搀猀 Ⰰ 䌀䌀吀 ㌀ 뀀䬀 ⼀ 㐀 뀀䬀 ⼀ 㔀㜀 뀀䬀 ⼀㘀 뀀䬀⼀㘀㔀 뀀䬀 ⠀䄀猀 瀀攀爀 䄀一匀䤀 䈀椀渀⤀Ⰰ 匀䐀䌀䴀⠀匀琀愀渀搀愀爀搀 䐀攀瘀椀愀琀椀漀渀 䌀漀氀漀爀 䴀愀琀挀栀椀渀最⤀ 㰀㌀Ⰰ 䴀愀砀椀洀甀洀 瀀漀眀攀爀 挀漀渀猀甀洀瀀琀椀漀渀 猀栀漀甀氀搀 渀漀琀 洀漀爀攀 琀栀愀渀 琀栀攀 猀瀀攀挀椀昀椀攀搀 爀愀琀椀渀最 愀渀搀 䘀椀砀琀甀爀攀 猀栀愀氀氀 戀攀 漀昀 爀攀氀攀瘀愀渀琀 䈀䤀匀 猀琀愀渀搀愀爀搀 愀渀搀 琀爀愀搀攀 洀愀爀欀 挀攀爀琀椀昀椀挀愀琀攀 ⠀ 吀⸀䌀⸀⤀⸀ 䴀愀渀甀昀愀挀琀甀爀攀猀 圀漀爀搀 䴀愀爀欀⼀ 一愀洀攀 䔀渀最爀愀瘀攀搀⼀ 䔀洀戀漀猀猀椀渀最⼀ 匀挀爀攀攀渀 瀀爀椀渀琀椀渀最 漀渀 栀漀甀猀椀渀最⸀ 伀䔀䴀 洀甀猀琀 栀愀瘀攀 椀琀猀 漀眀渀 椀渀 栀漀甀猀攀 一䄀䈀䰀 氀愀戀 猀攀琀甀瀀 昀漀爀 愀氀氀 琀攀猀琀椀渀最 昀愀挀椀氀椀琀椀攀猀 昀漀爀 䰀䔀䐀 昀椀砀琀甀爀攀猀⸀ ∀挀漀洀瀀氀攀琀攀 椀渀 愀氀氀 爀攀猀瀀攀挀琀 椀⼀挀 挀漀渀渀攀挀琀椀漀渀猀 眀椀琀栀 ⸀㔀 猀焀 洀洀 䘀刀䰀匀Ⰰ 倀嘀䌀 椀渀猀甀氀愀琀攀搀 挀漀瀀瀀攀爀 挀漀渀搀甀挀琀漀爀 猀椀渀最氀攀 挀漀爀攀 挀愀戀氀攀 愀渀搀 攀愀爀琀栀椀渀最 攀琀挀⸀ 愀猀 爀攀焀甀椀爀攀搀 眀椀琀栀 䴀椀渀椀洀甀洀 㔀 礀攀愀爀 伀䔀䴀 眀愀爀爀愀渀琀礀⸀ 匀礀猀琀攀洀 氀甀洀攀渀 攀昀昀椀挀愀挀礀 㸀㌀㔀 氀洀⼀圀愀琀琀 漀甀琀瀀甀琀 ⸀ 䰀䴀㜀㤀 ☀ 䰀䴀㠀 吀攀猀琀 爀攀瀀漀爀琀 昀爀漀洀 一䄀䈀䰀 氀愀戀 昀漀爀 愀氀氀 琀攀猀琀椀渀最 爀攀焀甀椀爀攀搀 昀漀爀 䰀䔀䐀 昀椀砀琀甀爀攀猀 愀猀 瀀攀爀 䈀䤀匀 猀栀愀氀氀 戀攀 猀甀戀洀椀琀琀攀搀⸀ 匀栀愀瀀攀 猀椀稀攀 愀渀搀 䌀䌀吀 猀栀愀氀氀 戀攀 愀猀 愀瀀瀀爀漀瘀攀搀 戀礀 䔀渀最椀渀攀攀爀ⴀ椀渀ⴀ䌀栀愀爀最攀 愀猀 瀀攀爀 爀攀焀甀椀爀攀洀攀渀琀⸀ ⠀吀栀攀爀洀愀氀 洀愀渀愀最攀洀攀渀琀㨀 栀攀愀琀 猀椀渀欀 漀昀 愀氀甀洀椀渀甀洀 栀漀甀猀椀渀最 猀甀挀栀 琀栀愀琀 䰀䔀䐀 樀甀渀挀琀椀漀渀 琀攀洀瀀攀爀愀琀甀爀攀 猀栀愀氀氀 渀漀琀 爀椀猀攀 愀戀漀瘀攀 㤀 뀀䌀⤀⸀ 㠀 眀愀琀琀䴀ःSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, WITHOUT REMOTE class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)Dz̃͌±Ĉ匀灵汰⁹景䄠⁃㌲⼰㔲‰潖瑬ⱳ㔠‰穈攠桸畡瑳映湡湩汣摵湩牰癯摩湩畮獴潢瑬ⱳ洠畯瑮湩牦浡湡瑯敨捡散獳牯敩湩汣摵湩潣湮捥楴湯瑥挠浯汰瑥獡爠煥極敲〳洰睳敥¤ŘЈ 䔨䕌呃䥒䅃⁌佗䭒 瑓晡畑牡整†圠物湩潦楬桧⁴潰湩⁴楷桴ㄠ㔮猠浭䘠䱒⁓噐⁃湩畳慬整潣灰牥挠湯畤瑣牯猠湩汧潣敲挠扡敬椠畳晲捡 敲散獳摥洠摥畩汣獡噐⁃潣摮極ⱴ眠瑩潭畤慬睳瑩档潭畤慬汰瑡ⱥ猠極慴汢䥇戠硯愠摮攠牡桴湩桴潰湩⁴楷桴ㄠ㔮猠浭剆卌倠䍖椠獮汵瑡摥挠灯数潣摮捵潴楳杮敬挠牯慣汢瑥獡爠煥極敲片畯⁰C✀␀ᬀ⼀ᴀ㔀ᬀᤀआSupplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) 36 Wattږĉ匀甀瀀瀀氀礀椀渀最Ⰰ 椀渀猀琀愀氀氀愀琀椀漀渀Ⰰ 吀攀猀琀椀渀最 ☀ 䌀漀洀洀椀猀猀椀漀渀椀渀最 漀昀 䰀䔀䐀 刀攀挀攀猀猀攀搀 ⼀ 猀甀爀昀愀挀攀 䐀漀眀渀 氀椀最栀琀攀爀 ⠀刀漀甀渀搀 ⼀ 猀焀甀愀爀攀⼀ 刀攀挀琀愀渀最甀氀愀爀⤀ 匀䴀䐀 琀礀瀀攀 漀昀 昀漀氀氀漀眀椀渀最 戀漀搀礀 洀愀琀攀爀椀愀氀 眀椀琀栀 倀䴀䴀䄀 愀渀搀 瀀爀椀猀洀愀琀椀挀 搀椀昀昀甀猀攀爀 愀渀搀 挀漀渀猀琀爀甀挀琀椀漀渀 愀猀 瀀攀爀 䤀匀 㨀 ㌀㈀㈀ 眀椀琀栀 搀爀椀瘀攀爀 愀猀 瀀攀爀 琀栀攀 爀攀焀甀椀爀攀洀攀渀琀 眀椀琀栀 䐀爀椀瘀攀爀 攀昀昀椀挀椀攀渀挀礀 㸀㠀㔀─Ⰰ 伀瀀攀爀愀琀椀渀最 瘀漀氀琀愀最攀 䄀䌀 㐀 ⴀ㈀㜀 嘀漀氀琀Ⰰ 昀爀攀焀 㔀 ⼀㘀 栀稀Ⰰ 伀瀀攀爀愀琀椀渀最 琀攀洀瀀 爀愀渀最攀 ⴀ㔀 搀攀最 琀漀 㐀 搀攀最 挀攀渀琀椀最爀愀搀攀Ⰰ 椀渀琀攀爀渀愀氀 猀甀爀最攀 瀀爀漀琀攀挀琀椀漀渀 漀昀 ㈀⸀㔀 䬀嘀 眀椀琀栀 匀栀漀爀琀 ☀ 伀瀀攀渀 挀椀爀挀甀椀琀 瀀爀漀琀攀挀琀椀漀渀 Ⰰ吀䠀䐀 㰀 ─ Ⰰ 倀⸀ 䘀⸀攀〢⸀㤀㔀Ⰰ 䤀倀㈀ Ⰰ 䌀刀䤀 㸀㠀 Ⰰ 唀䜀刀 ⠀唀渀椀昀椀攀搀 䜀氀愀爀攀 刀愀琀椀渀最⤀ 㰀 㤀Ⰰ 䘀氀椀挀欀攀爀 昀爀攀攀 ⠀昀氀椀挀欀攀爀 猀栀漀甀氀搀 戀攀 戀攀氀漀眀 㔀 ─⤀Ⰰ 氀椀昀攀 琀椀洀攀 ⠀䰀䔀䐀Ⰰ䐀爀椀瘀攀爀 ☀ 攀氀攀挀琀爀椀挀愀氀 挀椀爀挀甀椀琀爀礀⤀Ⰰ 氀椀昀攀 琀椀洀攀 漀昀 洀椀渀椀洀甀洀 㔀 䈀甀爀渀椀渀最 䠀漀甀爀猀 眀椀琀栀 Ⰰ 㜀 ─ 漀昀 椀渀椀琀椀愀氀 䰀甀洀攀渀 洀愀椀渀琀愀椀渀攀搀 琀椀氀氀 氀椀昀攀 攀渀搀猀 Ⰰ 䌀䌀吀 ㌀ 뀀䬀 ⼀ 㐀 뀀䬀 ⼀ 㔀㜀 뀀䬀 ⼀㘀 뀀䬀⼀㘀㔀 뀀䬀 ⠀䄀猀 瀀攀爀 䄀一匀䤀 䈀椀渀⤀Ⰰ 匀䐀䌀䴀⠀匀琀愀渀搀愀爀搀 䐀攀瘀椀愀琀椀漀渀 䌀漀氀漀爀 䴀愀琀挀栀椀渀最⤀ 㰀㌀Ⰰ 䴀愀砀椀洀甀洀 瀀漀眀攀爀 挀漀渀猀甀洀瀀琀椀漀渀 猀栀漀甀氀搀 渀漀琀 洀漀爀攀 琀栀愀渀 琀栀攀 猀瀀攀挀椀昀椀攀搀 爀愀琀椀渀最 愀渀搀 䘀椀砀琀甀爀攀 猀栀愀氀氀 戀攀 漀昀 爀攀氀攀瘀愀渀琀 䈀䤀匀 猀琀愀渀搀愀爀搀 愀渀搀 琀爀愀搀攀 洀愀爀欀 挀攀爀琀椀昀椀挀愀琀攀 ⠀ 吀⸀䌀⸀⤀⸀ 䴀愀渀甀昀愀挀琀甀爀攀猀 圀漀爀搀 䴀愀爀欀⼀ 一愀洀攀 䔀渀最爀愀瘀攀搀⼀ 䔀洀戀漀猀猀椀渀最⼀ 匀挀爀攀攀渀 瀀爀椀渀琀椀渀最 漀渀 栀漀甀猀椀渀最⸀ 伀䔀䴀 洀甀猀琀 栀愀瘀攀 椀琀猀 漀眀渀 椀渀 栀漀甀猀攀 一䄀䈀䰀 氀愀戀 猀攀琀甀瀀 昀漀爀 愀氀氀 琀攀猀琀椀渀最 昀愀挀椀氀椀琀椀攀猀 昀漀爀 䰀䔀䐀 昀椀砀琀甀爀攀猀⸀ ∀挀漀洀瀀氀攀琀攀 椀渀 愀氀氀 爀攀猀瀀攀挀琀 椀⼀挀 挀漀渀渀攀挀琀椀漀渀猀 眀椀琀栀 ⸀㔀 猀焀 洀洀 䘀刀䰀匀Ⰰ 倀嘀䌀 椀渀猀甀氀愀琀攀搀 挀漀瀀瀀攀爀 挀漀渀搀甀挀琀漀爀 猀椀渀最氀攀 挀漀爀攀 挀愀戀氀攀 愀渀搀 攀愀爀琀栀椀渀最 攀琀挀⸀ 愀猀 爀攀焀甀椀爀攀搀 眀椀琀栀 䴀椀渀椀洀甀洀 㔀 礀攀愀爀 伀䔀䴀 眀愀爀爀愀渀琀礀⸀ 匀礀猀琀攀洀 氀甀洀攀渀 攀昀昀椀挀愀挀礀 㸀㌀㔀 氀洀⼀圀愀琀琀 漀甀琀瀀甀琀 ⸀ 䰀䴀㜀㤀 ☀ 䰀䴀㠀 吀攀猀琀 爀攀瀀漀爀琀 昀爀漀洀 一䄀䈀䰀 氀愀戀 昀漀爀 愀氀氀 琀攀猀琀椀渀最 爀攀焀甀椀爀攀搀 昀漀爀 䰀䔀䐀 昀椀砀琀甀爀攀猀 愀猀 瀀攀爀 䈀䤀匀 猀栀愀氀氀 戀攀 猀甀戀洀椀琀琀攀搀⸀ 匀栀愀瀀攀 猀椀稀攀 愀渀搀 䌀䌀吀 猀栀愀氀氀 戀攀 愀猀 愀瀀瀀爀漀瘀攀搀 戀礀 䔀渀最椀渀攀攀爀ⴀ椀渀ⴀ䌀栀愀爀最攀 愀猀 瀀攀爀 爀攀焀甀椀爀攀洀攀渀琀⸀ ⠀吀栀攀爀洀愀氀 洀愀渀愀最攀洀攀渀琀㨀 栀攀愀琀 猀椀渀欀 漀昀 愀氀甀洀椀渀甀洀 栀漀甀猀椀渀最 猀甀挀栀 琀栀愀琀 䰀䔀䐀 樀甀渀挀琀椀漀渀 琀攀洀瀀攀爀愀琀甀爀攀 猀栀愀氀氀 渀漀琀 爀椀猀攀 愀戀漀瘀攀 㤀 뀀䌀⤀⸀ 㠀 眀愀琀琀輀✆܀〳眠瑡䵴ःSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, WITHOUT REMOTE class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)Dẑ±Ĉ匀灵汰⁹景䄠⁃㌲⼰㔲‰潖瑬ⱳ㔠‰穈攠桸畡瑳映湡湩汣摵湩牰癯摩湩畮獴潢瑬ⱳ洠畯瑮湩牦浡湡瑯敨捡散獳牯敩湩汣摵湩潣湮捥楴湯瑥挠浯汰瑥獡爠煥極敲〳洰睳敥¥Ʃ匀灵汰楹杮愠摮映硩湩景映汯潬楷杮眠祡畳晲捡⽥爠捥獥潭湵楴杮敶瑲捩污琠灹ⱥ㐠㔱嘠偔⁎䍍⁂楤瑳楲畢楴湯戠慯摲漠桳敥⁴瑳敥ⱬ搠獵⁴牰瑯捥整Ɽ搠汵⁹潰摷牥瀠楡瑮摥湩汣獵癩景㈠〰䄠琠湩敮潣灰牥戠獵戠牡潣浭湯渠略牴污氠湩Ⱬ攠牡桴戠牡楤慢潦潭湵楴杮䴠䉃戨瑵眠瑩潨瑵䴠䉃湡湩潣敭⥲愠敲畱物摥⸠⠠潎整㨠嘠牥楴慣祴数䴠䉃吠䑐⁂獩渠牯慭汬⁹獵摥眠敨敲㌠瀠慨敳漠瑵敬獴愠敲爠煥極敲 ‴慷⁹㐨⬠ㄠ⤲潄扵敬搠潯÷Ĉ倀潲楶楤杮愠摮映硩湩潦汬睯湩慲楴杮愠摮戠敲歡湩慣慰楣祴䴠䍃⁂楷桴琠敨浲浯条敮楴敲敬獡湡整浲湩污猠牰慥敤獲椠硥獩楴杮挠扵捩敬瀠湡汥戠慯摲椠据畬楤杮搠楲汬湩潨敬湩挠扵捩敬瀠湡汥慭楫杮挠湯敮瑣潩獮瑥愠敲畱物摥ㄮ〰䄠㌠‰䅋䘠䵐䍃⁂äȡ匀灵汰⁹愠摮†慬楹杮†景愠畬業楮浵†潣摮捵潴倠䍖†湩畳慬整牡潭牵摥猠牥敶桳慥桴摥挠扡敬ㄱ〰嘠汯獴朠慲敤愠⁴敤瑰景㜠〵洠敢潬⁷牧畯摮氠癥汥漠敶畣桳潩景㜠‵浭桴捩慳摮愠汬愠潲湵湡牰瑯捥整楷桴戠牵瑮戠楲正湯猠摩獥愠摮漠潴传畳晲捡桴慣汢畲桳污敢映硩摥漠⹍⹓挠慬灭瑥漠畳瑩扡敬猠穩牯愠楤敲瑣摥戠⁹桴湅楧敮牥䤭据慨杲ⱥ挠浯汰瑥湩愠汬爠獥数瑣桔牡潭牵湩景琠敨挠扡敬猠慨汬戠牰灯牥祬挠湯敮瑣摥眠瑩桴慥瑲潣摮捵潴祢挠慬灭瑥††††††††††††††††††††ㄠ‰煳洠⁸‴潣敲ĥ匀灵汰楹杮愠摮洠歡湩畯摴潯湥整浲湩瑡潩楷桴挠獡⁴敲楳潣灭畯摮椠据畬楤杮愠畬業楮浵氠杵湡瑯敨潪湩楴杮洠瑡牥慩獬映牯映汯潬楷杮猠穩景倠䍖椠獮汵瑡摥愠摮倠䍖猠敨瑡敨 䱘䕐愠畬業楮浵挠湯畤瑣牯挠扡敬漠⸱‱噋朠慲敤愠敲畱物摥††††††††††††††††††††봳堠㌠‵煳浭㌀₽⁘㔹猠洠Ὥ〱䠠倮楍楮丠污潫灯䤠獮慴汬潩Ѯ瑍匀瑥䴀瑥敲(䈀ぉ〱〱〰〱〱〰〰〰〰〰〰ㄵ䈵ぉ〱〰〴⠹䥂〰〰〰〰〰〰〰㔰㔱䥂〰〰㐱〱(䈀ぉ〱〱〰〱〱〰〰〰〰〰〰ㄵ䈵ぉ〱〰ㄴ⠱䥂〰〰〰〰〰〰〰㔰㔱䥂〰〰㐱㈱(䈀ぉ〱〱〰〱〱〰〰〰〰〰〰ㄵ䈵ぉ〱〰ㄴ⠳䥂〰〰〰〰〰〰〰㔰㔱䥂〰〰㐱㐱(䈀ぉ〱〱〰〱〱〰〰〰〰〰〰ㄵ䈵ぉ〱〰ㄴ⠵䥂〰〰〰〰〰〰〰㔰㔱䥂〰〰㐱㘱(䈀ぉ〱〱〰〱〱〰〰〰〰〰〰ㄵ䈵ぉ〱〰S
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete Hot finished welded type tubes
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Ridges plain (500 - 600mm)
Gutter (600 mm over all girth)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
Bend 87.5° 100mm Bend
Shoe (Plain) 100 mm Shoe
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Brick edging 7cm wide 11.4cm. deep to plinth protection with bricks of class designation 75 including grouting with cement mortar 1:4 (1 cement : 4 fine sand)
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
Sand Filling in plinth i/c supply of necessary quantity of sand from a distance not exceeding 8 Km from the site of work and i/c watering dressing etc.
Providing and laying of PCC 1:4:8 grade in foundation & pilnth with proper compecting.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.56 MB
BOQ_2058106.xls
BOQ • 1.05 MB
1.pdf
Additional Documents • 0.19 MB
NNM.pdf
Tender Documents • 4.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .