Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹7.4 L+₹16,406.50 (2.27%)Rejected-Finance | L2 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹17,000
Closing Date
4 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Fatehgarh
AGE (I) Fatehgarh cantt
SPECIAL REPAIR TO BLDG NO T-01 AT AGE (I) MES FATEHGARH CANTT
2024_MES_654506_1
AGE (I)/FAT/ET-01 OF 2024-2025
Open Tender
Miscellaneous Works
Works
180 days
AGE (I) Fatehgarh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) Fatehgarh
₹17,000
Yes
23 Oct 2024
27 Jun 2024
10 Sept 2024
27 Jun 2024
4 Sept 2024
12 Jul 2024
28 Jun 2024 - 11 Jul 2024
Amount
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) not exc 1.5 sqm each complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm each but not exc 4.00 sqm each complete all as specified and directed.
Taking down and Refixing in same opening chowkhats or frame with shutters (without taking off shutters from the frames) exc 1.5 sqm each but not exc 4.00 sqm each complete all as specified and directed.
S&F for Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars , dovetailed or welded complete all as specified and directed.
S&F for Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with out glazing bars , dovetailed or welded complete all as specified and directed.
S & F 3 mm thick sheet glass, ordinary quality and glazing with mitred beads or oil putty including glazing clips in square not exc 0.50 sqm in each pane complete all as specified and directed.
S & F in Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, welded tinned tacks,rivets,wooden beads etc. to steel windows/wodden doors/windows complete all as specified and directed.
M & L for framed work such as guard bars made of square bars fixed to flat iron or box type window frame confirming to Fe-290 Gde E-165. complete all as specified and directed.
M&L Preparing new surfaces of steel and applying two coats of synthetic enamel paint over a coad of red oxide complete all as specified and as directed.
M&L Preparing new surfaces of steel and applying two coats of synthetic enamel paint complete all as specified and as directed.
M&L for preparing old painted surfaces of steel and applying two coats of synthetic enamel paint, complete all as specified and as directed.
Demolition of brickwork masonary built in lime or cement mortar including all quiens arches, pillars etc. But including concrete articles.
M & L Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in cm (1:6) complete
-ditto- all as per above but except Bricks etc complete all as specified and directed.
Taking down cement plaster on brick wall or stone wall etc. including raking out joints hacking for key, scrubbing down with water etc and disposed off unserviceable material of out side defence land complete all as specified and directed.
M & L Rendering 15mm thick in CM (1:6) on fair faces of brick work or concrete surfaces to be finished even and smooth without using extra cement.
M & L Rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces to be finished even and smooth without using extra cement.
M & L three coat of white wash on new plastered wall surfaces including preparation all as specified and directed by Engineer-in-Charge.
M & L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
M & L for preparation of old plastered surfaces of walls by complete removal of existing treatment and making surface smooth and applying two coats of cement base paint over alkali resistant primer complete all as directed.
M & L for preparation of old plastered surfaces of walls by rubbing down and making surface smooth and applying two coats of white wash complete all as directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar complete all as specified and directed
M & L for Machine cut kota stone slab flooring 16-18 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete over 20 mm thick screed bed in CM 1:6 complete all as specified and directed.
M & L for Machine cut kota stone slab in skirting 16-18 mm thick over 10 mm thick rendering in CM 1:3 laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including rubbing and mirror polishing complete all as specified and directed.
M&L for Mirror polishing on Kota stone/ stone work where ever required to give high gloss finish complete all as specified and directed
Demolition of PCC in Ground floors/PCC Path/Plinth Protection and paving n.exc 15cm thickness (below or above ground level) etc complete all as specified and directed.
M & L 75 mm thick PCC 1:3:6 type C-2 using 40mm graded aggregateds as in plinth protection, subbase of floors complete all as specified and directed.
M & L 70 mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in flooring and similar work complete all as specified and directed
Dismantaling of asbestos cement (Corrugated, semi corrugated etc) sheetiting in roof covering complete all as specified and directed.
S & F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
S & F for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in ridge, roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
Dismantling timber scantlings in framed work 40 sq. cm and over in section, in any position complete all as specified and directed.
S&F Rolled sections of grade Fe 410 - W (Gde E- 250) quality A as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
S&F Framed work of grade Fe 410 - W (Gde E- 250) quality A as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings including mild steel hinges, hand made mild steel sliding door bolt, mild steel handles and all necessary fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed
S&F Plates (plain or chequered) of grade Fe 410 - W (Gde E- 250) quality A channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square complete all specified and directed
S&F 1.25mm thick mild steel plain black sheet in hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc. with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and directed
S&F Wire netting of galvanised steel wire 1.40mm dia, mesh size 20mm fixed with tinned tacks of wire staples as in doors complete all as specified and directed
Taking down copper/aluminium point wiring of any description and any position (light, fan, socket or power point) complete, including fixture and fittings such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified.
Taking down copper/aluminium sub main wiring and making good disturbed surfaces to match with the existing surface roof/wall/floor complete all as specified and as directed
M&L for point wiring with 1100 volt grade PVC insulated and unsheathed 1.5 Sq mm (FRLS) multistranded copper conductor cable with continuous earth wire of 1.5 Sq mm (FRLS) multistranded copper conductor cable PVC insulated and unsheathed, drawn in & including concealed PVC rigid conduit medium grade with fittings (ISI marked) sunken pressed steel galvanised terminal boxes with top cover ISI marked plastic laminated hylam sheet for housing/ fixing switches etc for One light/fan/exhaust fan point controlled by one switch complete all as specified and directed for the following- Note- (i) The quoted rete is deemed to be included for the chases cutting. (ii) Cutting chases for concealed shall be made good using CM 1:4 and surface finished to match the existing surface & colour.
Ditto as above here in before but for One 5 pin 5 Amp switch socket combination point on an independent board complete all as specified and directed
Ditto as above here in before but for One 5 pin 5 Amp socket point controlled by one switch on same board complete all as specified and directed
Ditto as above here in before but for one 16 Amp 6 Pin switch socket combination independent with 4.0 Sqmm FRLS unsheathed copper conductor single core multistranded complete all as specified and directed
S&F Switch Piano flush type 5 Amp single pole one way complete all as specified and directed
S&F Switch socket combination 2 in 1 flush type 6 Amp 5 Pin complete all as specified and directed
S&F Switch socket combination 2 in 1 flush type 16 Amp 5 Pin complete
Supply and fix electronic fan regulator 5 stepped type complete all as specified and directed
S&F Ceiling rose PVC/Poly carbonate isolated body three terminal AC 230 volts complete all as specified and directed.
M&L for sub main wiring with two single core 6 Sqmm FRLS copper conductor PVC insulated and unsheathed cable including PVC conduit medium grade (appropriate size) concealed in wall for sub main connection including 6 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. (Note :- Two runs of 6 sqmm FRLS and one run of 6 sqmm FRLS copper conductor shall be measured as one unit length)
S&F in repair of VTPN DB suitable for Mounting MCCB as Incomer of rating 100 Amp Vertical distribution board 12 way with suitable rated bus bar having IP-43 protection and double metal door concealed in wall including connection with aluminium thimbles as required complete all as specified.
S&F in repair of MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with aluminium thimbles as required complete all as specified.
S&F of MCCB 100 Amp, 16KA, 4 Pole including complete electrical connection by appropriate size of copper lugs complete all as specified and directed
S&F of MCB SPN 63 Amp 240 volt 'C' curve complete all as specifed and directed.
S&F of MCB of MCB SP 10 to 32 Amp 240 Volt 'C' curve 10 KA complete all as specified and directed.
Supply and fixing of LED lights fitting 4 feet, 20 Watt, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose incl dismantaling complete all as specified and directed.
S & F building security LED Light 30 Watt made up pressure die-cast aluminium housing with high power LED as lighting source and lens embedded PC having top opening separate driver compartment with IP-65 protection and impact resistance of IK 07 for building secuity purpose with bracket size made of GI pipe medicum grade 40 mm dia 1.5 mtr long bend to shape as required and fixing with two nos MS Clamp of size 40x6 mm for fixing of builiding security light fittings complete all as specified and directed.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip armoured service cable pole to building electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 3.5 Core including complete all as specified and directed.
M & L Sand cushioning for cables complete complete all as specified and directed
M & L for old size brick well burnt, laid flat, for cable protection complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtrs wide and not exceeding 1.5 mtrs in depth for laying of cables including getting out in any type of soil complete all as specified and directed.
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any type of soil complete all as specified and directed
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown in electrical plate No - 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but without earth lead protection pipe and test on completion after dismantling unserviceable erthing (above GL only) complete all as directed incl dismantling of exsisting earthing. Note :- On testing after completion if desired earth resistence is not obtained, the earthing will be redone at no extra cost.)
M/S Shree Gopal Engineers & Contractor (BID ID -3071380)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .