| 3 | L3₹11.5 LAdmitted-Finance | -26.62% | ₹11.5 L | L3 | Admitted-Finance |
| 4 | L4₹12.2 LAdmitted-Finance F 1080 PHASE III RIICO INDUSTRIAL AREA BHIWADI ALWAR RAJASTHAN 301019 | ALWAR | RAJASTHAN | 301019 | -22.00% | ₹12.2 L | L4 | Admitted-Finance |
| 5 | L5₹14.0 LAdmitted-Finance JAIPUR RAJASTHAN 302018 INDIA UDYAM RJ 17 0276368 | JAIPUR | RAJASTHAN | 302018 | -10.66% | ₹14.0 L | L5 | Admitted-Finance |
Tender Value
₹15.6 L
EMD Value
₹31,240
Closing Date
11 May 2026, 6:00 pmClosed
EE (ELECT-I) JDA JAIPUR
EE (ELECT-I) JDA JAIPUR
Providing and Fixing of Phase wire in Vatika Road, JDA, Jaipur.
2026_JDAJP_554987_1
EE (ELECT-I)/02/2025-26
Open Tender
Electrical Works
30 days
JDA AREA
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
ONLINE JDA WEBSITE
₹31,240
Yes
15 May 2026
29 Apr 2026
15 May 2026
30 Apr 2026
11 May 2026
30 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and installation of spike of M.S. rod 20mm dia 3.0mtr. long for earthing of (tower/pole) drive into earth by mechanical means sturcture connection the spike with cross arm top hamper PCC pole, lattics tower to earth etc. complete as per technical specification of DISCOM. Complete Rate Group 1 | - | Per Set | 1,819 | - |
| 2 | Supply and fixing of LT porcelain shackle insulator as per IS:1443 1979 and as per Discom's standard specifications, suitable for working voltage 1100 volts including all accessories like GI Hardware fittings confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR.
100mm x 110mm | - | Mtr. | 119 | - |
| 3Supplying and drawing of XLPE insulated LT Aerial bunched Aluminium conductor cable confirming to IS 14255/1995 and IS 398 (Pt-4)/ 1994 and as per Discom Specs. on existing cross arms through I hook with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | |||||
| 3.1 | 1 X 25 sq. mm. + 1X25 sq. mm. (insulated) | - | Mtr. | 63 | - |
| 4Supply and fixing of following LT Supporting accessories with nut bolt & Clamps made out as per standard Discom's specifications with two coats of Red oxide and two coats of Aluminium paint etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | |||||
| 4.1 | Suspension clamp with eye hook & Pole clamp | - | Each | 527 | - |
| 4.2 | Dead end clamp with eye hook & Pole clamp | - | Each | 612 | - |
| 5Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | |||||
| 5.1 | 16.0 Sq.mm 4 core Complete Rate Armoured | - | Mtr. | 179 | - |
| 6Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | |||||
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.82 MB
02TDPhaseWire.pdf
Tender Documents • 7.28 MB
BOQ_988342.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid