| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 CrAccepted-AOC | ₹4.5 Cr | L1 | Accepted-AOC lowest |
| 2 | L2₹4.6 CrRejected-Finance | ₹4.6 Cr | L2 | Rejected-Finance higher rates |
| 3 | Rejected-Technical | - | - | Rejected-Technical Non-Responsive |
| Sl No | Description | Qty | Unit | Sukoi Engineers L1 | Stellar Ecoenergy Solutions LLP L2 |
|---|---|---|---|---|---|
| 1.00 | Nitrogen Pressure Test including of required agent and commisioning of System all inclusive of required agenct complete in all respect (N.S) | 1 | Nos. | 4,12,521 ₹4.1 L | 4,22,422 ₹4.2 L |
| 2.00 | Providing and fixing 25mm conduit to lay wire 25mm conduit to lay wirecomplete in all respect (N.S) | 1,498 | Nos. | 340 ₹5.1 L | 348 ₹5.2 L |
| 3.00 | Providing and fixing 2C X 1.5 sqmm Twisted pair FRLS Armoured Cable complete in all respect (N.S) | 3,058 | Nos. | 195 ₹6.0 L | 201 ₹6.1 L |
| 4.00 | Providing and fixing Marked `GAS BANK`, Overall size 400 mm x 150 mm Marked `GAS BANK`, Overall size 400 mm x 150 mm complete in all respect (N.S) | 7 | Nos. | 6,547 ₹45,829 | 6,685 ₹46,795 |
| 5.00 | Providing and fixing Photoluminescent ( self glowing) Signage on 1 mm thick PVC rigid sheet, of following type: Marked `GAS PROTECTED AREA`, Overall size 400 mm x 150 mm complete in all respect (N.S) | 7 | Nos. | 6,547 ₹45,829 | 6,685 ₹46,795 |
| 6.00 | Providing and fixing Piping, fittings and supports, etc.Pipe (S) : M.S. Seamless To ASTM A-106, SCH. 40 Including necessary fittings and accessories like tees, bends, elbows, unions, reducers, flanges, gaskets etc. as required including fixing of pipework on walls, slabs with supports, clamps etc. all complete Discharge Piping SCH. 40(complete in all respect (N.S) | 1 | Nos. | 39,45,967 ₹39.5 L | 40,40,515 ₹40.4 L |
| 7.00 | Providing and fixing Piping, fittings and supports, etc.Pipe (S) : M.S. Seamless To ASTM A-106, SCH. 80Including necessary fittings and accessories like tees, bends, elbows, unions, reducers, flanges, gaskets etc. as required including fixing of pipework on walls, slabs with supports, clamps etc. all complete Discharge Piping SCH. 80complete in all respect (N.S) | 1 | Nos. | 30,43,751 ₹30.4 L | 31,14,574 ₹31.1 L |
| 8.00 | Room Integrity Test including of required Pressurize Fans and commisioning of System all inclusivecomplete in all respect (N.S) | 1 | Nos. | 9,95,289 ₹10.0 L | 10,17,428 ₹10.2 L |
| 9.00 | Supply and Installation 12V 7.2 Ah battery for gas release panel and addressable panel as per specification of Engineer-in-charge(N.S) | 16 | Nos. | 2,881 ₹46,096 | 2,950 ₹47,200 |
| 10.00 | Supply and Installation Abort switch for Gas Release (MCP Yellow) as per specification of Engineer in-Charge (N.S) | 7 | Nos. | 3,012 ₹21,084 | 3,082 ₹21,574 |
Tender Value
₹4.4 Cr
EMD Value
₹8.9 L
Closing Date
12 Aug 2025, 5:00 pmClosed
CHARANDEEP SINGH
PD - I, Gurgaon
Providing Gas Suppression System in New Judicial Complex (Tower of Justice) at Gurugram.
2025_HRY_462507_1
2025CF63FF71 62D3 4667 89A3 C0E3750EA12A621BAR
Open Tender
Civil Works
90 days
Gurugram
2 documents required · 2 mandatory
₹15,000
₹8.9 L
Yes
11 Dec 2025
2 Aug 2025
13 Aug 2025
2 Aug 2025
12 Aug 2025
2 Aug 2025
Amount
Nitrogen Pressure Test including of required agent and commisioning of System all inclusive of required agenct complete in all respect (N.S)
Providing and fixing 25mm conduit to lay wire 25mm conduit to lay wirecomplete in all respect (N.S)
Providing and fixing 2C X 1.5 sqmm Twisted pair FRLS Armoured Cable complete in all respect (N.S)
Providing and fixing Marked `GAS BANK`, Overall size 400 mm x 150 mm Marked `GAS BANK`, Overall size 400 mm x 150 mm complete in all respect (N.S)
Providing and fixing Photoluminescent ( self glowing) Signage on 1 mm thick PVC rigid sheet, of following type: Marked `GAS PROTECTED AREA`, Overall size 400 mm x 150 mm complete in all respect (N.S)
Providing and fixing Piping, fittings and supports, etc.Pipe (S) : M.S. Seamless To ASTM A-106, SCH. 40 Including necessary fittings and accessories like tees, bends, elbows, unions, reducers, flanges, gaskets etc. as required including fixing of pipework on walls, slabs with supports, clamps etc. all complete Discharge Piping SCH. 40(complete in all respect (N.S)
Providing and fixing Piping, fittings and supports, etc.Pipe (S) : M.S. Seamless To ASTM A-106, SCH. 80Including necessary fittings and accessories like tees, bends, elbows, unions, reducers, flanges, gaskets etc. as required including fixing of pipework on walls, slabs with supports, clamps etc. all complete Discharge Piping SCH. 80complete in all respect (N.S)
Room Integrity Test including of required Pressurize Fans and commisioning of System all inclusivecomplete in all respect (N.S)
Supply and Installation 12V 7.2 Ah battery for gas release panel and addressable panel as per specification of Engineer-in-charge(N.S)
Supply and Installation Abort switch for Gas Release (MCP Yellow) as per specification of Engineer in-Charge (N.S)
Supply and Installation Addressable hooter cum flasher Supply Voltage 15 -28 VDC Max. sound output N/A / 97dB(A) plus /-3dB @1metre2 viltage 15-28 VDC standby current 225 uA, Max sound output N/A/97 db(A) plus /- 3db @ 1 meter 2 Tempature range 25`c to plus 70`c plus Humidity Max 95% relative humidity (non-condensing) IP44 with deep bases (BPR, BPW) IP65 for MI-BSO-PP-N/I with sealed deep base WRR) As per specification of Engineer-in-Charge(N.S)
Supply and Installation Addressable MCP Operating voltage - 15 to 30 Vdc as per specification of Engineer-in-charge(N.S)
Supply and Installation Addressable panel MA-8000, 4 loop control panel, 200W 24V power supply, 38Ah max batteries, 7` color Touch display as per specification of Engineer-in-Charge
Supply and Installation Control module for integration as per specification of Engineer-in-charge
Supply and Installation Gas release panel-2 zone, 1 gas release circuits as per sepcification of Engineer-in-Charge(N.S)
Supply and Installation Manual release switch for Gas Release (MCP Green) as per Specification of Engineer-in Charge (N.S)
Supply and Installation Monitor Module for integration Operating Voltage Range:15 to 32VDC (Min 16.5VDC for LED operation) Maximum Standby Current: 140 µA @24 V and 25oC (no communication) LED Current (Red): 1.5 mA LED Current (Yellow): 5.5 mA Isolator features: see S00-7100 Humidity: 5% to 95% relative humidity (non-condensing) Maximum Wire Gauge 2.5 mm² complete in all respect (N.S)
Supply and Installation Monitor Module for integration Operating Voltage Range:15 to 32VDC (Min 16.5VDC for LED operation) Maximum Standby Current: 140 µA @24 V and 25oC (no communication) LED Current (Red): 1.5 mA LED Current (Yellow): 5.5 mA Isolator features: see S00-7100 Humidity: 5% to 95% relative humidity (non-condensing) Maximum Wire Gauge 2.5 mm² as per specification of Engineer-in-charge(N.S)
Supply and Installation Multi detector complete as required as per specification of Engineer-in-Charge (N.S)
Supply and Installation of 1-1/2` Manifold Check Valve installed at the discharge manifold to allow removal of any FK-5-1-12 cylinder fri=om the manifold while still retaining a closed system complete in all respect (N.S)
Supply and Installation of 2` Manifold Check Valve installed at the discharge manifold to allow removal of any FK-5-1-12 cylinder fri=om the manifold while still retaining a closed system complete in all respect (N.S)
Supply and Installation of Male Brass Tee complete in all respect (N.S)
Supply and Installation of Brass Male Elbow complete in all respect (N.S)
Supply and Installation of Cylinder Limit Switch for indication of cylinder low pressurecomplete in all respect (N.S)
Supply and Installation of Cylinder Strap for 120 and 140 Ltr. Cylinder complete in all respect (N.S)
Supply and Installation of Cylinder Strap for 180 Ltr. Cylinder complete in all respect (N.S)
Supply and Installation of Cylinder Strap for 34 Ltr. Cylinder complete in all respect (N.S)
Supply and Installation of Discharge Hose, 1-1/2` Hose with Elbow and connectors complete assembly to Connect FK-5-1-12 Cylinder Assembly Discharge outlet with Discharge Pipe or Discharge Manifold (34, 120 Ltr. Cylinder) .complete in all respect (N.S)
Supply and Installation of Discharge Hose, 2` Hose with Elbow and connectors complete assembly to Connect FK-5-1-12 Cylinder Assembly Discharge outlet with Discharge Pipe or Discharge Manifold for (140 and 140 Ltr Cylinder) complete in all respect .(N.S) New
Supply and Installation of Electric and Manual Actutor Head Operated electrically from the detection and Control System or locally with a manual lever on the control head complete in all respect .(N.S)
Supply and Installation of Flexible Action Hose (Pilot pressure is directed to a pressure operated control head on each cylinder valve using 1/4 inch actuation hose) complete in all respect (N.S)
Supply and Installation of Maniflod / System Supervisory Switch fro indication of discharge of system complete in all respect (N.S)
Supply and Installation of Master Cylinder Adapter Kit used to accurate the slave cylinder complete in all respect (N.S)
Supply and Installation of Pressure operated control head which allows for pressure actuation slave cylinders and is mounted directly on top of the slave cylinders valvecomplete in all respect . (N.S)
Supply and Installation of`Discharge Nozzles to Discharge FK-5-1-12 Gas in the Hazard Area as hydraulic calculation and flow rate required in 180 deg/360 Deg Discharge Pattern.complete in all respect (N.S)
Supply and Installation Response Indicator as per specification of Engineer-in-Charge (N.S)
Supply, installation, testing and commissioning of following minimum capacity cylinder UL listed / CCOE/PESO Approved and confirming to IS7285 and IS 15493 and upto date amendment suitable for filling FK-5-1-12 gas for fire fighting system complete with Valve and warning sign stickers, including suitable clamp to fix the wall etc complete as reqd. 180 Liters cylinder complete in all respect (N.S)
Supply, installation, testing and commissioning of following minimum capacity cylinder UL listed / CCOE/PESO Approved and confirming to IS7285 and IS 15493 and upto date amendment suitable for filling FK-5-1-12 gas for fire fighting system complete with Valve and warning sign stickers, including suitable clamp to fix the wall etc complete as reqd. 34 Liters cylinder complete in all respect (N.S)
Supplying,filling,testing and commissioning of FK-5-1-12 Fire protection fluid compound of carbon, fluorine and qxygen (CF plus A22CFC(O)CF(CF3)2 complete in all respect (N.S)
Supplying,filling,testing and commissioning of FK-5-1-12 Fire protection fluid compound of carbon, fluorine and qxygen (CF plus A22CFC(O)CF(CF3)2 complete in all respect (N.S) (new)
Stellar Ecoenergy Solutions LLP (BID ID -1312746)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
AD0128678.pdf
Tender Documents • 0.40 MB
BOQ_540287.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid