| 1 | L1₹38.0 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹39.7 L+₹1.8 L (4.67%)Accepted-Finance H NO 138 SHANTI NAGAR NEAR REAL PUBLIC SCHOOL VIJAY NAGAR GHAZIABAD UTTAR PRADESH 201009 | GHAZIABAD | UTTAR PRADESH | 201009 | L2 | Accepted-Finance L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Required Paper Not Attach |
| Sl No | Description | Qty | Unit | M/S YASH TRADERS HAPUR L1 | Yash Contractor L2 |
|---|---|---|---|---|---|
| 1.00Carriage of following material of estimate, from Electricity store center, Hapur to site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge from JE Store/Store center Hapur/Ghaziabad/Bulandshar (0-50 Km) | |||||
| 1.01 | 33 KV Lighting Arrester | 18 | Nos. | 800 ₹14,400 | 500 ₹9,000 Lowest |
| 1.02 | Battery Set | 4 | Nos. | 1,100 ₹4,400 | 500 ₹2,000 Lowest |
| 1.03 | Battery Charger | 3 | Nos. | 1,600 ₹4,800 | 500 ₹1,500 Lowest |
| 1.04 | 33 KV CT out door type | 9 | Nos. | 2,550 ₹22,950 | 2,000 ₹18,000 Lowest |
| 1.05 | 11 KV Lightning Arrester (on LT T/F) | 270 | Nos. | 250 ₹67,500 Lowest | 300 ₹81,000 |
| 1.06 | 33 KV Control Panel Double T/F | 3 | Nos. | 3,550 ₹10,650 Lowest | 4,000 ₹12,000 |
| 1.07 | 33 KV Line Isolater | 7 | Nos. | 1,850 ₹12,950 | 1,200 ₹8,400 Lowest |
| 1.08 | 33 KV Fuse Set | 2 | Nos. | 3,550 ₹7,100 | 1,500 ₹3,000 Lowest |
| 1.09 | 33 KV PT outdoor type | 12 | Nos. | 2,600 ₹31,200 | 1,500 ₹18,000 Lowest |
Tender Value
₹36 L
EMD Value
₹36,000
Closing Date
27 Sept 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPERINTENDING ENGINEER
SUPERINTENDING ENGINEER EDC HAPUR
FOR PROTECTION RELATED WORK AT VARIOUS SUB-STATION IN THE AREA OF GARHMUKTESHWAR UNDER BUSINESS PLAN 2025-26. 58 NO. WORK IN THE JURISDICTION OF EDD-GARHMUKTESHWAR UNDER EDC., HAPUR.
2025_PVVNL_1071946_1
33(W)/EDCH/2025-26
Open Tender
Electrical Works
Item Rate
HAPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
SUPERINTENDING ENGINEER, EDC, HAPUR
₹36,000
Yes
4 Oct 2025
6 Sept 2025
27 Sept 2025
6 Sept 2025
27 Sept 2025
6 Sept 2025
Amount
Carriage of following material of estimate, from Electricity store center, Hapur to site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge from JE Store/Store center Hapur/Ghaziabad/Bulandshar (0-50 Km)
33 KV Lighting Arrester
Battery Set
Battery Charger
33 KV CT out door type
11 KV Lightning Arrester (on LT T/F)
33 KV Control Panel Double T/F
33 KV Line Isolater
33 KV Fuse Set
33 KV PT outdoor type
Providing and fixing 11 KV Relay, with 1 no. E/F, 2 no. O/C of C&S, Ashide, ABB make with 1&5 Amp Port Suitable for 11 kv & 33 KV feeder Pannel as per RESPO/Norms and as per direction of site incharge.
Providing and fixing of WTI Meter ISI Mark for 33/11 KV Power Transformer work including making connection proper opration of WTI , as per RESPO/Norms and as per direction of site incharge.
Providing and fixing of OTI Meter ISI Mark for 33/11 KV Power Transformer work including making connection proper opration of WTI, as per RESPO/Norms and as per direction of site incharge.
Providing and installation of maintenance free multifaceted proactive and corrosion free chemical earthing electrod size 80mm x 3000mm complete with 50KG backfill compound with all required accessories for Body/neutral earthing of Transformers, including cost of M.S. earth strip for connection the earth strip will be welded to the earthing and neutral support, as per RESPO/Norms and as per direction of site incharge.
Providing the material and execution GI pipe earthing with 40 mm dia B class GI Pipe 80 feet boar to water level for proper earthing at 33/11 KV substation with the help of 50x6 mm GI Strip duly welding to transformer other equipment.
Supply and laying ISI Make Copper Control Cable 4x2.5 Sq. mm. with make connection from control pannel to Power Transformer Instruments
Laying of LT 1x240 Sq.mm. PVC cable as per RESPO/Norms and as per direction of site incharge.
Providing and fixing of fire exitinguisher (9kg), as per direction of site incharge.
CO2 Type
ABC Type
Eraction and fixing and making connection of following material (as per RESPO Norms) at diffrent 33/11 KV substation were include making alignment, all required nut bolt, clamps, Lug, connector etc for safe & Porper oprations Provided by contractor
33 KV Lighting Arrester
Battery Set
Battery Charger
33 KV CT out door type
33 KV Control Panel Double T/F
33 KV Line Isolater
33 KV Fuse Set
33 KV PT outdoor type
Providing and fixing of 33 KV T/F control Panal Relay, as per RESPO/Norms and as per direction of site incharge. (Make C&S, Ashide, ABB)
Earthing of supports with MS earth Rod of (20x2500)mm long including excavation of pit and driving M.S. Rod 3.0 M apart from support and 0.5m below the ground level and connection below the earth electrodes with the help of G.I. wire & earthing lugs as per RESPO Drawing/Norms by providing proper size nuts & bolts, as per direction of site incharge.
fixing of Vaccume Interupter in 11 KV Pannel, as per direction of site incharge.
Fixing of 11 KV Lighting Arrester with 11/0.4 KV DT and make connection (3.5x5 mm GI Strip will uniform fixing of Lighting Arrester with transformer)
Yash Contractor (BID ID -5567333)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .