Loading…
Loading…
Tender ID
Tender Value
₹11.3 L
EMD Value
₹28,223
Closing Date
8 Aug 2025, 11:00 pmClosed
Karnataka Power Transmission Corporation Limited
Providing 02 Nos of additional 11kV PCVCB for load bifurcation of existing feeders and new feeder at 66/11kV Guddenahalli Substation under Mandya Operation Division, KTPCL in Nagamangala Taluk and Mandya District on PTK basis
KPTCL/2025-26/SS/WORK_INDENT2292/CALL-2
KPTCL/2025-26/SS/WORK_INDENT2292/CALL-2
Open
Sub-Station
Two Tender Document System(Two Cover)
KPTCL CEE Transmission Zone Office Mysuru
₹500
₹28,223
24 Jul 2025
24 Jul 2025
11 Aug 2025
6 Aug 2025
4 Aug 2025
Providing 02 Nos of additional 11kV PCVCB for load bifurcation of existing feeders and new feeder at 66/11kV Guddenahalli Substation under Mandya Operation Division, KTPCL in Nagamangala Taluk and Mandya District on PTK basis
11kV 400A, Double break GOS.
11kV 400A, Single break GOS.
LA’S 9KV,10KA class for DP Structures, Station type(Metal Oxide type).
11kV Epoxy Busbar insulators with nut & bolts suitable(10mm) for LA GI Flat supporting.
11kV class PVC insulated Copper control cables with Lugs/ferrules /Glands as per the technical specifications
a)19 core 2.5 Sq mm (for Annunciation)
b) 4 core 6 Sq mm (for CT,PT &DC Connection)
c) 4 core 4 Sq mm ( for AC supply)
d) 2 core 6 Sq mm ( for AC supply)
e) 2 core 2.5 Sq mm ( for AC supply)
PVC pipe 75 mm dia accessories
PVC bend 75 mm dia
Beams out of channel 100X50 with arragements for stringing power conductors on 11 kV side a) 1B2 4.00 mtrs long, long with clamps,bolts and nuts.0.036 MT each , (8No's channels for beams & Annunciato...
Drake ACSR Conductor
Coyote ACSR Conductor
Bolted Type Tension clamp for single Coyote ACSR conductor 70/90KN 16mm
Bolted Type Tension clamp for single Drake ACSR conductor 70/90KN 16mm
Disc insulator 90kN
CT clamps for Single Drake
C Type Wedge connector (Coyote- Coyote) ACSR conductor. / T-Clamp (Coyote- Coyote)
C Type Wedge connector (Drake- Coyote) ACSR conductor. / T-Clamp (Coyote- Coyote)
Coyote pad clamps
Earth bond 450mm long ( for GOS & CT)
9.0mtr RCC Pole for DP structure 145 KG WL
DP Set (2 Pole Strucrure Kit) as per IS-1977 For RCC Pole - 9 Mtr Long, 145KG WL - GI
H frame set for GOS mounting
A.Grounding of equipments by providing cast iron pipe of 100mm ID 13mm thickness, 2.75 Mtrs long with 2 part clamp out of G.I.Flat 50X6mm continuously welded all-round the pipe using cast iron welding...
Earthing name plates for new earting pits
Galvanised Bolts & Nuts of Various Sizes
SCADA Materials:
Multi Function Transducers(MFT)
As per KPTCL Std, Interface: RS-485 Daisy Chain to RTU Com port,wiring: Both 3ph 4wire, supply: self powered, Measuring range voltage: 120%, current: 1...
Input Vtg:110V DC, input indicated by LED, input range 110VDC to 140V DC, sourcing Vtg output 48VDC, No of iputs: 12, No of outputs: 8, Source current: 5mA, at output, 8way switch to be p...
Terminal Blocks (knife type) (8 TB's per Feeder) = (8x2 nos = 16)
Current Cable - 2.5 Sq-mm multistrand copper wire for CT termination
(Each color 15mtrs-R-Y-B) (15mts x 3 x 2 feeder = 90mtr)
Voltage Cable - 2.5 Sq-mm multistrand copper wire for PT termination
(Each color 5mtrs-R-Y-B-N) (5mts x 4 x 2 feeder = 40mtr)
Control Cable - 10 Copper core x 1.5sqmm
(From remote contol desk to RTU) (16mtrs x 2 nos = 32 mtrs)
Signal Cable - 10 Copper core x 0.5sqmm
Feeder to Feeder loop = 16mts x 2 nos =32 mtrs) Remote control desk to RTU (for DI): 16mtrs x 2 Nos. = 32 mtrs
1.5 Sqmm Grey wire for interfacing of DI and DO (20 mtrs for each panel)(20x2=40mtr)
Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the size 2.5 sqmm (80 lugs/panel x 2 = 160)
C-type channel of size 50x100x50x6mm (50cm/panel) = (0.5m x 2 nos = 1 Mtrs)
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (Size: 32mm dia)
CT TB's - 6 nos for each panel (2 x 6 = 12 nos)
11 KV Switchgear for Feeder panel: 11 KV PCVCB, 500MVA, 25KA, 1250A Incomer 800A feeder with scada compatible features.
Annunciation & Remote control panel (1IC+4F)
11kV 400A, Double break GOS.
11kV 400A, Single break GOS.
LA’S 9KV,10KA class for DP Structures, Station type(Metal Oxide type).
11kV class PVC insulated Copper control cables with Lugs/ferrules /Glands as per the technical specifications
a)19 core 2.5 Sq mm (for Annunciation)
b) 4 core 6 Sq mm (for CT,PT &DC Connection)
c) 4 core 4 Sq mm ( for AC supply)
d) 2 core 6 Sq mm ( for AC supply)
e) 2 core 2.5 Sq mm ( for AC supply)
Beams out of channel 100X50 with arragements for stringing power conductors on 11 kV side a) 1B2 4.00 mtrs long, long with clamps,bolts and nuts.0.036 MT each , (8No's channels for beams & Annunciato...
Drake ACSR Conductor
Coyote ACSR Conductor
DP Set (2 Pole Strucrure Kit) as per IS-1977 For RCC Pole-9 Mtr Long, 145KG WL-GI
H frame set for GOS mounting
A.Grounding of equipments by providing cast iron pipe of 100mm ID 13mm thickness, 2.75 Mtrs long with 2 part clamp out of G.I.Flat 50X6mm continuously welded all-round the pipe using cast iron welding...
B. Supplying & Providing 450 mm dia 450 mm height 1.5" to 2" thick hume pipe collar (non pressure type) for earth pits including all lead and lifts etc.
C. Grounding of equipment with 50x6mm G.I. Flat and connecting Equipment to the earth mat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and c...
Earthing name plates for new earting pits
Loading and unloading of poles, switchgear and other materials etc
Multi Function Transducers(MFT)
As per KPTCL Std, Interface: RS-485 Daisy Chain to RTU Com port,wiring: Both 3ph 4wire, supply: self powered, Measuring range voltage: 120%, current: 120%, frequency: 4...
Input Vtg:110V DC, input indicated by LED, input range 110VDC to 140V DC, sourcing Vtg output 48VDC, No of iputs: 12, No of outputs: 8, Source current: 5mA, at output, 8way switch to be p...
Control Cable - 10 Copper core x 1.5sqmm
(From remote contol desk to RTU) (16mtrs x 2 nos = 32 mtrs)
Signal Cable - 10 Copper core x 0.5sqmm
Feeder to Feeder loop = 16mts x 2 nos =32 mtrs) Remote control desk to RTU (for DI):16mtrs x 2 Nos. = 32 mtrs
1.5 Sqmm Grey wire for interfacing of DI and DO (20 mtrs for each panel) (20x2=40mtr)
CT TBs - 6 nos for each panel (2 x 6 = 12 nos)
Miscellaneous items like, Ferrules, cable ties, insulation tape, & Labour for cutting, weldind, drilling, etc
Configuration of RTU and Engineering along with validation of data at SLDC
11 KV Switchgear for Feeder panel: 11 KV PCVCB, 500MVA,25KA, 1250A Incomer 800A feeder with SCADA compatible features with Current transformer of Ratio 200-100/1-1A
Testing & Commissioning: Wiring: ...
b) For additional 11kV panel Set
Wiring & Assisting in Testing and Commissioning
11kV Switchgear
Earth Work excavation for foundation of buildings, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in hard soil not exceeding 1.5 m. in dept...
Providing and laying in position plain cement concrete of mix 1:4:8 using 40 mm and down size graded granite metal, machine mixed, concrete laid in layers not exceeding 15 cms thick, well compacted, i...
Providing and laying in position reinforced cement concrete of mix 1:1.5:3 with 20mm and down size graded granite metal machine mixed, concrete laid in layers not exceeding 15 cms thick vibrated for r...
Providing and fabricating structural steel work Using M.S flats, M.S channels, M.S. square or round bar, for helter,columns.purlins,rafters,cable duct work,etc,as per approved design, drawing includin...
Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/w...
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by r...
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .