| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.0 CrAccepted-AOC 1723 GUPTA AND SONS SECTOR 39 B CHANDIGARH CHANDIGARH CHANDIGARH 160036 UDYAM CH 01 0042756 | CHANDIGARH | CHANDIGARH | 160036 | ₹1.0 Cr | L-1 | Accepted-AOC Being L-1 |
| 2 | L-2₹1.1 Cr+₹11,478.50 (0.11%)Rejected-AOC 6146 HIRA CHOWK SIRKI BAZAR BATHINDA PB 151005 | BATHINDA | PUNJAB | 151005 | ₹1.1 Cr+₹11,478.50 (0.11%) | L-2 | Rejected-AOC Other than L-1 |
| 3 | L-3₹1.2 Cr+₹14.6 L (13.9%)Rejected-AOC | ₹1.2 Cr+₹14.6 L (13.9%) | L-3 | Rejected-AOC Other than L-1 |
| 4 | Rejected-Technical HOUSE NO 44 MASTER COLONY SATROD KHAS HISAR HARYANA 125044 | HISAR | HISAR | HARYANA | 125044 | - | - | Rejected-Technical Firm is not enlisted in appropriate category of work |
| 5 | Rejected-Technical 01 ENTERPRISES | - | - | Rejected-Technical Firm is not enlisted in appropriate category of work |
| Sl No | Description | Qty | Unit | M/S Gupta and Sons L1 | Parveen Builders L3 | B B BUILDERS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed by Engineer-in-Charge. | 910 | SQM | 10 ₹9,100 Lowest | 20 ₹18,200 | 10 ₹9,100 Lowest |
| 2.00 | Demolition of stone slabs of any description or thickness in floors/ walls laid bedded and pointed in any mortar etc. complete removal of debris outside MD land complete all as specified and as directed by Engineer-in-Charge. | 36.2 | TEN SQM | 70 ₹2,534 Lowest | 200 ₹7,240 | 100 ₹3,620 |
| 3.00 | Demolition of cement concrete of any description and in any position not other wise specially provided for and removing all demolished material/ debris to out side MD land complete all as specified and as directed by Engineer-in-Charge. | 23.95 | CUM | 150 ₹3,592.5 Lowest | 500 ₹11,975 | 200 ₹4,790 |
| 4.00 | M&L for non skid coloured ceramic tiles 7 to 8mm thick square/ rectangular area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over 15 mm thick screed bed for floor finishes in CM 1:4 complete all as specified and as directed by Engineer-in-Charge. | 90 | SQM | 700 ₹63,000 | 850 ₹76,500 | 600 ₹54,000 Lowest |
| 5.00 | M&L for Glazed ceramic coloured printed tiles in vertical surfaces of size 300 mm x 450 mm x 7 mm set and jointed in neat cement slurry over and including 10 mm thick rendering in CM 1:4 for receiving the tiles complete all as specified and as directed by Engineer-in-Charge. | 285 | SQM | 700 ₹1,99,500 | 900 ₹2,56,500 | 550 ₹1,56,750 Lowest |
| 6.00 | Material and labour for coloured vitrified ceramic tiles, Double charge/ Ultracharged 10 mm thick (square/ rectangular), area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge. | 150 | SQM | 1,200 ₹1,80,000 | 1,100 ₹1,65,000 | 1,000 ₹1,50,000 Lowest |
| 7.00 | All as per Serial item No 6.00 here-in-before but as in skirting including necessary cutting of tiles over and including 10 mm thick rendering in CM 1:4 complete all as specified and as directed by Engineer-in-Charge. | 15 | SQM | 1,200 ₹18,000 | 1,100 ₹16,500 | 1,000 ₹15,000 Lowest |
| 8.00 | Material and labour for coloured vitrified ceramic tiles, light shade, 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge. | 280 | SQM | 790 ₹2,21,200 | 950 ₹2,66,000 | 750 ₹2,10,000 Lowest |
| 9.00 | All as per Serial item No 8.00 here-in-before but as in skirting including necessary cutting of tiles over and including 10 mm thick rendering in CM 1:4 complete all as specified and as directed by Engineer-in-Charge. | 40 | SQM | 790 ₹31,600 | 1,000 ₹40,000 | 750 ₹30,000 Lowest |
| 10.00 | M&L for 25 mm thick PCC 1:2:4, type B-0 (using 12.5 mm gradred stone aggregates) as in floor, finished even and rough to receive the top finishes like kota stone/ floor tiling complete all as specified and as directed by Engineer-in-Charge. | 90 | SQM | 200 ₹18,000 | 125 ₹11,250 | 100 ₹9,000 Lowest |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
2 Aug 2025, 6:00 pmClosed
CWE Chandimandir
HQ CWE Chandimandir, PIN-134107
CWE/CHM-23/2025-26 SPECIAL REPAIR TO BUILDING NO P-1064/ 2014 UNDER GE CHANDIMANDIR AT CHANDIMANDIR MIL STN
2025_MES_717405_1
CWE/CHM-23/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE Chandimandir
Class a(i) and b(i)
9 documents required · 9 mandatory
₹1,000
GE Chandimandir
₹2.2 L
17 Oct 2025
28 Jun 2025
9 Aug 2025
28 Jun 2025
2 Aug 2025
19 Jul 2025
30 Jun 2025 - 5 Jul 2025
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed by Engineer-in-Charge.
Demolition of stone slabs of any description or thickness in floors/ walls laid bedded and pointed in any mortar etc. complete removal of debris outside MD land complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete of any description and in any position not other wise specially provided for and removing all demolished material/ debris to out side MD land complete all as specified and as directed by Engineer-in-Charge.
M&L for non skid coloured ceramic tiles 7 to 8mm thick square/ rectangular area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over 15 mm thick screed bed for floor finishes in CM 1:4 complete all as specified and as directed by Engineer-in-Charge.
M&L for Glazed ceramic coloured printed tiles in vertical surfaces of size 300 mm x 450 mm x 7 mm set and jointed in neat cement slurry over and including 10 mm thick rendering in CM 1:4 for receiving the tiles complete all as specified and as directed by Engineer-in-Charge.
Material and labour for coloured vitrified ceramic tiles, Double charge/ Ultracharged 10 mm thick (square/ rectangular), area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.
All as per Serial item No 6.00 here-in-before but as in skirting including necessary cutting of tiles over and including 10 mm thick rendering in CM 1:4 complete all as specified and as directed by Engineer-in-Charge.
Material and labour for coloured vitrified ceramic tiles, light shade, 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.
All as per Serial item No 8.00 here-in-before but as in skirting including necessary cutting of tiles over and including 10 mm thick rendering in CM 1:4 complete all as specified and as directed by Engineer-in-Charge.
M&L for 25 mm thick PCC 1:2:4, type B-0 (using 12.5 mm gradred stone aggregates) as in floor, finished even and rough to receive the top finishes like kota stone/ floor tiling complete all as specified and as directed by Engineer-in-Charge.
M&L for 75 mm thick Cement concrete 1:3:6, type C-2 (using 40 mm graded aggregate) as in Plinth protection finished the concrete surface even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
Materials and labour for 18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platform and like in cement morter (1:4) including 15 mm thick cement mortar 1:4 screed bed pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed by Engineer-in-Charge.
M&L for 18 mm thick Granite work (table rubbed and polished in two sides) in urinal partition fixed in wall by cutting groove and set in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with granite shade with Rounding to edges exposed to view complete all as specified and as directed by Engineer-in-Charge.
Providing edge moulding to 16-18 mm thick stone (any description) of counters, vanities etc, including machine polishing to edge to give high gloss finish for granite stone etc. complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Baroda Green Granite tiles 18 to 20 mm thick, machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding, polishing complete, laid over and including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.
Material and labour Baroda Green Granite tiles 18 to 20 mm thick machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry and pointed with white with admixture of pigment to match the shade of granite stone incl grinding polishing complete, laid over and including 10 mm thick rendering in CM 1:4 complete all as specified and as directed by Engineer-in-Charge.
M&L for factory made, heavy duty parking tiles, 600 mm x 600 mm x 20 mm thick (with grey cement and pigments), set, jointed and pointed in neat cement slurry with grey cement with pigment to match the colour of tiles, glossy finish, laid over and including 20 mm thick screed bed in cement mortar 1:6, complete all as specified and as directed by Engineer-in-Charge.
M&L for 100 mm thick Plain Cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregates) as in sub base for tiles complete all as specified and as directed by Engineer-in-Charge.
M&L for Machine pressed Precast coloured concrete paver block of 60 mm thickness, M-35 grade, with grey cement and pigment, glossy finish on top conforming to IS 15658-2006, with approved colour, design and pattern as in footpath, parks, lawns, drive ways or light traffic parking etc, made by table vibratary method using PU mould, over and including 50 mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed by Engineer-in-Charge.
Demolition of reinforced concrete such as roofs, floors, beams, staircase, landing, chajjas, facia and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified and as directed by Engineer-in-Charge.
M&L for reinforced cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregates) as in Slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer-in-Charge.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar works exceeding 200 mm thick (Horizontal or sloping) for rough finish surface of concrete complete all as specified and as directed by Engineer-in-Charge.
M&L for mild steel TMT bars, 10 mm dia & over, cut to length, bent to shape as required including cranking, bending specially for columns, hooking ends & binding with MS wire annealed not less than 0.9 mm dia welding as required at site complete all as specified and as directed by Engineer-in-Charge.
Demolition of brick work masonry, built in cement mortar including dismantling all quions, arches, pillars etc complete all as specified and as directed by Engineer-in-Charge.
M&L for brick work with sub class 'B' bricks (old size bricks) straight/ curved on plan to any radius built in cement mortar 1:4, as in half brick thick walls complete all as specified and as directed by Engineer-in-Charge.
Material & Labour for Brick work with sub class 'B' Bricks (old size bricks), straight or curved on plan exceeding 6 metre mean radius built in CM 1:6, complete all as specified and as directed Engineer-in-Charge.
Taking down cement plaster and sand grid on brick/ stone walls etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for 10 mm thick rendering on fair faces brick work Cement and Sand mortar 1:6 over brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
M&L for Rendering 15 mm thick plaster in cement mortar 1:4 mixed with WPC on fair faces of brick wall or concrete surfaces finished even and smooth without using extra complete all as specified and directed by Engineer-in-charge. (Note : WPC will be measured and paid for separately)
Supply only integral water proofing compound, ISI marked, complete all specified and directed by Engineer-in-Charge.
M&L for Rendering 5 mm thick on fair faces of concrete ceiling surfaces in cement mortar 1:3, finished even and smooth without using extra cement complete all specified and directed by Engineer-in-Charge.
M&L for Preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper white or tinted over a coat of alkali resistant primer and 1.00 mm thick cement base wall care putty complete all as specified and directed by Engineer-in-Charge.
M&L for Complete removal of existing treatment on wall surfaces of any description and applying two coats of Oil bound Distemper, over 1.00 mm thick cement base wall care putty as preparatory to distemper on surfaces of wall up to height of three storey building including necessary scafolding and safety arrangements complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15 mm bore, brass, chromium plated, mixer for mixing Hot and Cold water screwed down for iron pipes for center hole WHB mixer complete all as specified and directed by Engineer–in-Charge.
M&L for preparation of newly plastered ceiling surfaces and applying two coats of oil bound distemper over a coat of primer on ceiling surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for Preparation of old decorated ceiling surfaces and applying two coat of oil bound distemper complete all as specified and directed by Engineer–in-Charge.
M&L for preparation of newly plastered surface of wall, chajjas, parapets etc. and applying two coats of weather resistant exterior emulsion 100% acrylic @1.80 ltr (undiluted)/ 10 Sqm diluted with water in 5:2 ratio, applied with fully automatic airless spray machine, allow 6-8 hrs to dry the surface in between two coats, over and including a coat coat of exterior grade washable acrylic putty with and including erection and dismantling of mild steel double scaffolding to carry out works upto to triple storey building complete all as per manufacturer's instructions, make and shade of paint shall be approved by GE.
M&L for complete removal and preparation of old decorated surface of wall, chajjas, parapets etc. by using sanding machine having RPM not less than 1500, sanding pad of 80 grit having dia 7"/9" to make the surface free from dust, loose paint etc, filling the cracks/ knots/ depressions with epoxy crack filling compound of approved grade, removing loose materials after filling the cracks, and applying two coats of weather resistant exterior emulsion 100% acrylic @1.80 ltr (undiluted)/10 Sqm diluted with water in 5:2 ratio, applied with fully automatic airless spray machine, allow 6-8 hrs to dry the surface in between two coats over and including a coat of exterior grade washable acrylic putty with and including erection and dismantling of mild steel double scaffolding to carry out works upto triple storey building complete all as per manufacturer's instructions, make and shade of paint shall be approved by GE.
Note for serial item no 37.00 and 38.00: i) The complete work should be carried out by authorised applicator of paint manufacturer. ii) Application of exterior finishes shall be carried out with machanical sander machine, machanical paint mixer and spray painting machine. iii) Working area should be covered with green cloths and all windows/ ventilators shall be covered properly by polythene paper etc. before spray painting and cleaning of glass pane after completion of work. iv) Rate shall be inclusive of erection and dismantling of MS double scaffolding for carrying out works upto four storeys.
Taking down chowkhats/ frames exceeding 1.5 Sqm but not exceeding 4 Sqm including shutters (without taking off shutters from the frames complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats/ frames not exceeding 1.5 Sqm including shutters (without taking off shutters from the frames) including grill etc complete all as specified and directed by Engineer-in-Charge.
Taking down shutters of any description exceeding 1.00 Sqm but not exceeding 2.00 Sqm complete all as specified and directed by Engineer-in-Charge.
S&F Pressed steel frame for doors with single rebates of size 105 x 60 mm including necessary fixing lugs/ hold fasts, hinges, lock strike plate, including filling hollow frame with PCC 1:3:6 etc. complete all as specified and directed by Engineer-in-Charge.
S&F 35 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type both side complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of windows, made out of pre-painted steel (Base steel as per IS 513 of 0.58 mm thick "D"' quality gavanized as per IS 277 with Zinc of 120 GSM). Primer Coated with epoxy primer of 5-7 micron thick, Finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be 72 x 55mm, center mullion should be of 72 x 50mm, section for fixed glass beading should be of 12 x 12 mm and section for shutter should be of 48 x 25mm. Outer frame & mullion sections to have rebate for glazed shutters, fly mesh and provision for guard bars/grills of 20 mm dia, flymesh shutter section should be of 20 x 40mm. The sections are to be cut to length mitre jointed with corner bracket, Centre mullions to be fixed with mullion cap, stay, handles 02 Nos of heavy duty stainless steel pivot hinges shall be provided per shutter. The windows should be fixed with 4 mm thick plain float glass and Stainless steel Mesh for flymesh shutter (304 Grade). Rubber Gaskets will be provided all around the glass. The above frame should be fixed to the concrete/ masonry wall by means of self expanding screws, including 10 mm square guard bars precoated MS with 150 mm complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 5 mm thick figured glass, pin head type, ordinary quality, of size in squares not exceding 0.5 sqm in each pane and fixed in any type of frame, glazing with oil putty (or beading) complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 5.5 mm thick sheet glass, ordinary quality, of size in squares not exceding 0.5 sqm in each pane and fixed in any type of frame, glazing with oil putty (or beading) complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 5.5 mm thick sheet glass, ordinary quality, of size in squares exceding 0.5 sqm in each pane and fixed in any type of frame, glazing with oil putty (or beading) complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair Powder coated aluminium work (minimum thickness of powder coating 50 micron) for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular ections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
Supply and fixing in repair Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for lazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
Material and labour 9mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with screws to timber/ aluminium frame work complete all as specified and directed by Engineer-in-Charge.
Supply and fixing mortice lock, vertical type, mild steel, 4 levers, size 100 mm, brass body, complete all as specified and directed by Engineer-in-Charge.
S&F in repair door closer (Aluminium extruded section) hydraulically regulated, designation No. 3, universial type, sutaible for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg complete all as specified and directed by Engineer-in-Charge.
S&F in repair 25 mm dia Stainless steel curtain rod with bracket and clamp fixed complete all as specified and directed by Engineer-in-Charge.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately) complete all as specified as per manufacturer's broucher and directed by Engineer-in-Charge.
S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutters of size 30 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed by Engineer-in-Charge. Note: stainless steel butt hinges and necessary S.S screws shall be paid separately.
M&L for framed work as in doors or gates/ grill/ grating/ guard bars/ hold fasts etc of angle, tee or any other sections of mild steel woork with Fe 410-W (Grade E 250 quality A) including welding, fabrication with gusset plate drilled holes for fixing of steel sheeting or any other sheet covering complete all as specified and directed by Engineer-in-Charge.
Material and labour for Butt hinges, 100 mm, extruded Aluminium alloy with galvanised mild steel hinge pin, type C-21 complete all as specified and directed by Engineer-in-Charge.
S&F 200 mm size Aluminium barrel tower bolt of extruded section complete all as specified and directed by Engineer-in-Charge.
S&F 150 mm size Aluminium barrel tower bolt of extruded section complete all as specified and directed by Engineer-in-Charge.
S&F 300 mm aluminium alloy, anodized, sliding door bolts with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed by Engineer-in-Charge.
S&F Aluminium handle, cast type anodized of size 150 mm, complete all as specified and directed by Engineer-in-Charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/ slabs, blankets, any thickness, including cover fillets complete all as specified and directed by Engineer-in-Charge.
Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) with semi-perforated 12 mm thick micro tegular edged GRG false ceiling tiles of perforated perforated 12 mm, Size 595 x 595 mm of approved texture, 12 mm thick thick micro tegular design and patterns having moisture micro tegular edged or 10 mm content less than 2%, humidity resistance edged GRG thick square edged of 99%, NRC0.50 to 0.75 as per IS false ceiling GRG false ceiling 8225:1987, non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter locking metal T-Grid of hot dipped galvanized iron section of 0.33 mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000 mm, cross-T of size 15 x 32 mm of length 1200 mm and secondary intermediate cross-T of size 15 x 32 mm of length 600 mm to form grid module of size 600 x 600 mm, Contd..
Contd,, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L shape level adjuster of size 85 x 25 x 2 mm. Galvanised iron perimeter wall angle of size 24 x 24 x 0.40 mm of length 3000 mm to be fixed on periphery with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.
Material and labour for 5 mm thick PVC Sheet fillet of width 35 mm for wall panelling, inclusive fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed by Engineer-in-Charge.
Material and labour for Solid PVC Wall lining consisting of 5 mm thick plain colour PVC Sheet inclusive of solvent cement and fixing at site on PVC frame as per specification drawing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair factory made, 18 mm thick solid WPC (Wood Polymer Composite) board of density 650 Kg/cum, with one side Prelaminated (white colour) /Rigidlam and other side balancing laminate (any colour used in exposed area), as in cupboard/ kitchen cabinet shutters/ drawer, front shutters, fixed with screws, solvent cement/ adhesive as per manufacturer's instructions complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing for 20 mm wide & 1 mm thick PVC edge beading, pasted on edges with suitable adhesive, complete all as specified and directed by Engineer-in-Charge.
Supply and fixed in repair magnetic catcher cum silencer and fixed with standard steel screws, complete all as specified and directed by Engineer-in-Charge.
S&F in repair hydraulic hinges for modular kitchen complete all as specified and directed by Engineer-in-Charge.
S&F in repair stainless steel handles, 150 mm long for modular kitchen complete all as specified and directed by Engineer-in-Charge.
S&F in repair stainless steel handles 300 mm long for modular kitchen complete all as specified and directed by Engineer-in-Charge.
S&F in repair Brass cupboard locks two lever, grade-I, Size 50 mm complete all as specified and directed by Engineer-in-Charge.
M&L preperation of new steel surfaces of any description, not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new wooden surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old steel surfaces of an description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old wooden surfaces of an description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
S&F 75 mm bore PVC (SWR) pipes, single socketed in any length, fixed with rubber ring joints fixed to walls/ floor including taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan necks etc. including removal to store complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm bore PVC (SWR) pipes, single socketed in any length, fixed with rubber ring joints laid in floors etc. including taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan necks etc. including removal to store complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls with PVC clamp including all fittings, heads, shoes, bends, swan necks etc. including removal to store complete all as specified and directed by Engineer-in-Charge.
S&F 75 mm bore PVC bends of any radius complete all as specified and directed by Engineer-in-Charge.
S&F 75 mm bore PVC bends with access door of any radius complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm bore PVC bends of any radius complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm bore PVC bends with access door of any radius complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm bore PVC (SWR) Juction (Single T) equal or un-equal complete all as specified and directed by Engineer-in-Charge.
S&F 75 mm bore PVC (SWR) Juction (Single T) equal or un-equal complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC SWR floor traps, 75 mm dia with grating including jointing to waste pipe with solvent cement and setting/ fixed in cement concrete 1:2:4, type B-1 complete all as specified and directed by Engineer-in-Charge.
S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) but including pvc seat cover including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc. as in repair complete all as specified and directed by Engineer-in-charge.
S&F in repair PVC valveless, syphonic action type flushing cistern, low level, white of 10 Litres capacity with inlet ball valve, float and handle including bracktes including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc. in repair complete all as specified and directed by Engineer-in-charge.
S&F Counter top wash basin, snow white colour and size of 560 x 470 x 190 mm, including fixing brackets and 32 mm dia brass chromium plated waste coupling & PVC waste pipe complete all as specified and directed by Engineer-in-charge.
S&F in repair Vitreous china urinal, Half stall type, white, complete including providing and fixing clamps, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; including 40 mm dia brass chromium plated waste coupling & PVC waste pipe, grating and union for discharge pipe including connection to drain (or outgoing pipe) and to flushing pipe, anti syphonage pipe, etc. in repair complete all as specified and directed by Engineer-in-charge.
S&F in repair Brass, CP, Bottle trap, dia of discharge pipe 40 mm having minimum water seal of 25 mm, complete all as specified and directed by Engineer-in-charge.
S&F in repair 15 mm bore brass, CP, Urinal valve, auto closing system (push cock) with built in control & wall flange complete all as specified and directed by Engineer-in-charge.
S&F in repair Brass, CP, urinal spreader suitable for 15 mm bore pipe complete all as specified and directed by Engineer-in-charge.
S&F in repair 15 mm dia Pillar tap, cast copper alloy, chromium plated, fancy type, chromium plated, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-charge.
S&F in repair Bib tap, brass, chromium plated, fancy type, long body with wall flange, screwed down for iron pipe or for brass ferrule, suitable for 15 mm bore pipe complete all as specified and directed by Engineer-in-charge.
S&F of PVC connections, 15 mm bore of 450 mm length with PTMT nut etc complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair 20 mm dia brass chromium plated towel rail, 600 mm long, fixed with chromium plated screws with pvc rawl plugs complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair Brass, CP, towel ring with chromium plated brass screws and pvc rawl plugs complete all as specified and directed by Engineer-in-charge.
S&F as in repair of angle valve/ stop cock, brass, chromium plated, fancy type, 15 mm bore, complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed by Engineer-in-Charge.
Supply and laying of 25 mm outer diameter CPVC Pipe SDR 11 and Plain CPVC SDR 11 fitting in wall, ceiling or floor etc. including taking up or down GI steel tubing, 20 mm bore with connections or fittings from wall, ceiling, floor etc., complete all as specified and as directed by Engineer-in-Charge.
Supply and laying of 20 mm outer diameter CPVC Pipe SDR 11 and Plain CPVC SDR 11 fitting in wall, ceiling or floor etc. including taking up or down GI steel tubing, 15 mm bore with connections or fittings from wall, ceiling, floor etc., complete all as specified and as directed by Engineer-in-Charge.
Supply and laying of 20 mm outer diameter CPVC Brass Elbow complete all as specified and as directed by Engineer-in-Charge.
Supply and laying of 20 mm outer diameter CPVC Brass Tee complete all as specified and as directed by Engineer-in-Charge.
Supply and laying of 20 mm outer diameter CPVC female Brass Thereaded Adaptor (FTA/FBTA) complete all as specified and as directed by Engineer-in-Charge.
Supply and laying of 25 mm outer diameter CPVC Ball Valve complete all as specified and as directed by Engineer-in-Charge.
Demolition of un-reinforced cement concrete exceeding 15 cm thick of any description and in any position not otherwise specially provided for and removing all demolished material/ debris to out side MD Land complete all as specified and as directed by Engineer-in-Charge.
M&L for Plain cement concrete 1:5:10, type E-2 (using 40mm graded aggregate) as in sunken filling and mass concrete complete all as specified and as directed by Engineer-in-Charge.
Material and labour Water proofing treatment to sunken portion and adjoining walls of kitchen, WC, Bath & Toilet, etc complete all as specified as under:- (a) 15 mm plaster in cement mortar (1:3) mixed with water proofing compound as per manufacturer’s instructions after roughning and cleaning the surface. (b) Curing the sunken portion with water minimum for 48 hours by ponding. (c) Applying 3 mm thick APP membranne with bitumen by torch application to the treated sunken surface over a coat of primer as per manufacturer's instructions. (d) Joints/ Traps/ WC/ soil pipes shall be properly sealed with approved sealing compound.
S&F Rotational moulded PVC, Triple layered, water storage tanks of capacity 500 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position all as specified in SSR Part I, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 20 mm size Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe including dismantling existing water tank complete all as specified and directed by Engineer-in-Charge.
M&L for providing precast cement concrete louvres and jallies, 1:2:4, Type B-0 (using 12.5 mm graded stone aggregates), 40 mm thick (measured solid) including all mouldings but excluding frame, set in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
Demolition of mud phuska as in roof of any thickness including plastering and leeping etc. (whether full thickness removed or only a part thereof) complete all as specified and directed by Engineer-in-Charge.
Dismantling of existing brick tiles or terracing tiles single layer on roof grouted in cement mortar including removal of any type of existing treatment complete all as specified and directed by Engineer-in-Charge.
M&L for Providing plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregates), 40 mm thick (averaging), as in levelling course on roofs, complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4, type B-1 (using 12.5 mm graded stone aggegates) cement concrete in roof coping complete all as specified and directed by Engineer-in-Charge.
M&L for Rendering 10 mm thick, finished even and fair on roof slab in cement mortar 1:4, including mixing with water proofing compound @ 3% by weight of cement complete all as specified and directed by Engineer-in-Charge. Note :- (WPC will be measured and paid for seperately).
M&L for wire brushing and cleaning top surfaces of tiles, lime terracing or cement concrete including flashing and junction of parapets etc. and surface painting with a layer of blown bitumen of any penetration applied hot@ 1.70 Kg per Sqm, blinded with grit or pea size gravel @ 0.006 cum and lightly tampered (area of flashing etc shall be added to the roof area) and APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced with polyester non woven fabric (weight not less than 150 gms/sqm) laid on primed surface by torch application complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete tiles of size 250 x 250 x 22 mm thick, machine pressed, factory made with grey cement and pigment laid in neat cement slurry over and including 20 mm thick cement screed bed in cm 1:6 mixed with water proofing polymeric compound with 3 mm thick/ wide joints filled with FEVIMATE of Dr Fixit or pidilite industries or tiles glue of STP ltd as approved by GE complete all as specified and directed by Engineer-in-Charge.
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed by Engineer-in-Charge.
Steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240, including shop coat of zinc chrome red oxide primer complete all as specified and as directed by Engineer-in-Charge.
Dismantling plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof coverings complete all as specified and as directed by Engineer-in-Charge.
S&F 2 mm thick solid Poly carbonate sheeting fixed with coach screws and washer and connected clamp in roof, wall and joint filling with silicon etc. complete all as specified and as directed by Engineer-in-Charge.
Providing and injecting chemical emulsion for Post Constructional Anti-termite treatment along external wall where the apron is not provided using chemical mulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300 mm including excavating channel along the wall and rodding etc. complete all as specified and as directed by Engineer-in-Charge.
Taking down copper/ aluminum point wiring for (light, fan, socket point 5/ 15 amps) complete including fitting such as switches, ceiling rose, light fittings, sockets, bulb holder, ceiling roses, existing PVC/ Steel conduit etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm, 1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm, 1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular GI metal sunken box of thickness not less than 1.2 mm and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall, comprising of One light/ bell/ buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator, complete all as specified and as directed by Engineer-in-Charge.
NOTE: (i) The quoted rate shall deemed to include the cost of metal flush boxes, modular white cover plate, provision of blank plates as per site requirement etc. (ii) Quoted rate shall also deemed to include cost of making necessary chases in walls for inserting metal boxes and making good the disturbed surfaces to match with existing. (iii) Instruction for point wiring to be followed/compiled strictly as per Para 1 (a) to (q), Page Ser No 439 of SSR Part-II of 2020.
All as per serial item 126.00 here-in-before but for socket outlet 3 pin 5 Amps on same board complete all as specified and as directed by Engineer-in-Charge.
All as per serial item No 126.00 here-in-before but for one socket outlet 3/ 5 pin, 5 amps on independent board complete all as specified and as directed by Engineer-in-Charge.
All as per Serial item No 126.00 here-in-before but for one socket outlet 3/5 pin, 15 amps on independent board size of cable 2.5 sqmm for phase, neutral & 2.5 sqmm as earth wire complete all as specified and as directed by Engineer-in-Charge.
S&F modular switch, one way, 6 Amps, one module, 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge.
S&F Modular socket outlet, 2 in 1, 3 pin 6 Amps, ISI marked, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F modular switch, one way, 16 Amps, one module, 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge.
S&F modular socket outlet 2 in 1, 6/16 Amps, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F modular bell push, single pole, one module 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F electric bell, AC, 230 volt, single pole complete all as specified and as directed by Engineer-in-Charge.
S&F modular fan regulator, suitable for BLDC fan as per make, single pole, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose, surface bakelite 65 x 50 mm dia three terminal complete all as specified and as directed by Engineer-in-Charge.
S&F Lamp holder, insulated body, PVC/ Polycarbonate type with backplate suitable for batten fitting complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in repair MCB, SP, 6 - 32 Amps, 'C' series, breaking cap 10KA, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair MCB, SPN, 40 to 63 Amp, 230 volts, having breaking capacity 10 KA "C" type complete all as specified and as directed by Engineer-in-Charge.
S&F in repair MCCB 4 pole, 3 phase, 415 volts of capacity 125 Amps, 16 KA with adjustable thermal and magnetic release complete with proper cooper thimble connection complete all as specified and as directed by Engineer-in-Charge.
S&F in repair SLIM LED batten with polycarbonate housing and diffuser with elegantly designed end caps 1 x 20W, 220 V, AC connecting up with three core flexible of suitable size from ceiling rose complete all as specified and as directed by Engineer-in-Charge.
S&F in repair LED Mirror light fitting, 10 watt with high output diffuser, 2 feet length, 220 volts, AC decorative box type with driver, holder including LED tubelight connection up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by engineer-in-charge.
S&F in repair LED light fitting 1x 9W/ 1x 10W bulkhead luminaries including LED light driver connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by engineer-in-charge.
Disconnecting and taking down carefully copper/ aluminium sub main wiring complete, including existing batten/ conduit etc., removing materials and making good disturbed surfaces of wall, floors, etc. complete all as specified and as directed by Engineer-in-Charge.
M&L for Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 6.0 sqmm, LT, 1100V grade, drawn through and including adequate sizes PVC non metallic conduit of 20 mm/ appropriate dia with accessories and fittings and one run of 6.0 sqmm single core multi stranded copper conductor cable as earth continuity conductor with accessories and fittings and connecting to existing main switch board/ DB and testing on completion complete all as specified and as directed by Engineer-in-Charge.
Note: 1. Two runs of cable, one run of earth wire and one run of PVC non mettalic conduit shall be measured as one run length. 2. Cable required for connection to DBs shall deemed to be incl in the quoted rates and shall not be measured separately. 3. Earth wire shall run inside the conduit pipe.
M&L for Sub main wiring with four runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 10.0 sqmm, LT, 1100V grade, drawn through and including adequate sizes PVC non metallic conduit of 25 mm/ appropriate dia with accessories and fittings and one run of 10.0 sqmm single core multi stranded copper conductor cable as earth continuity conductor with accessories and fittings and connecting to existing main switch board/ DB and testing on completion complete all as specified and as directed by Engineer-in-Charge.
Note: 1. Four runs of cable, one run of earth wire and one run of PVC non mettalic conduit shall be measured as one run length. 2. Cable required for connection to DBs shall deemed to be incl in the quoted rates and shall not be measured separately. 3. Earth wire shall run inside the conduit pipe.
Cutting chases, pinning in, making good to facing where required and pointing in CM (1:3) to ends or edges of landings, steps, cills, sunsheds, shelves, lintel etc for concealed water tubing, concealed conduit wiring etc not exceeding 10 cm width or girth including making good the disurbed surface complete all as specified and as directed by Engineer-in-charge.
Taking down carefully distribution board, any type by unscrewing from boards fitting and fixture such as MCB DB, of any size complete with all MCCB's, MCB's etc and removing from site, complete all as specified and as directed by Engineer-in-Charge.
S&F MCB distribution board, SPN 8 Way, Double door, sheet steel, phosphatised, powder painted with Copper bus bar 200 Amp, neutral link, earth bar and din rail, cable ties for cable management, 240 V, complete all as specified and as directed by Engineer-in-Charge.
S&F vertical TPN distribution board, double door, flush mounting with provision for MCCBs incommer upto 125 Amp, 415 volts & outgoing 4 way having IP43 protection complete all as specified and as directed by Engineer-in-Charge.
S&F sheet metal enclosure, SPN, with a two pin and earth plug socket complete including with 32 Amp MCB ‘C’ single pole 240 volt complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement LED building security/ street light fitting 35 Watt, 230 V AC, outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/ 66 protection including wall mounting GI bracket for light fitting made out of 25 mm GI 'light grade' pipe of upto 1.5 meter length complete all as specified and as directed by Engineer-in-charge.
Supply and fixing ceiling fan, 1200 mm sweep, Energy Saving model, Pearl white/ white in colour 350 RPM, 220 volt 50 Hz complete with canopy, down rod. Fan blade, Fan hook box type for hanging with complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge.
Supply and fixing exhuast fan, 450 mm, operating voltage at 220-240 V with all mounting accessories such as louvers etc., Cutting hole for air ducting for exhaust fan in Circle/ square shape or as per site requirement into or through concrete walls built in cement mortar of superficial area suitable for 450 mm exhaust fan including making good of disturbed area in cement mortar 1:3 or cement concrete 1:2:4, type B-l and cover hole as required complete all as specified and as directed by Engineer-in-Charge. Note :- Louvers will be same as per original manufacturer of exhaust fan.
Supply and fixing heavy duty air circulator wall mounted fan, sweep, 600 mm, three blades, alloy steel operating voltage at 220-240V with all mounting accessories complete all as specified and as directed by Engineer-in-Charge.
Taking down fan ceiling/ exhaust/ wall fan, dismatling blades and removing fan and blades to store for safe custody complete all as specified and as directed by Engineer-in-Charge.
Supply, installation, commissioning of Water cooler, fully stainless steel, electric driven, single phase having approx storage and nominal cooling capacity 40/80 complete including fixing with all connected fittings complete all as specified and as directed by Engineer-in-Charge.
Supply and install Air conditioner with split units (indoor/ outdoor) of Capacity 1.5 Ton complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality, electric driven, 230 Volts, single phase, 50 Hz supply, minimum 5 star rating and EER 3.2, working on R-134 or superior environment friendly refrigerant gas including copper tubing and Electrical connection between indoor and outdoor unit located upto a minimum 3 meter distance complete including condensate water drainage pipe of maximum 3 meter long including taking down existing AC and deposit to MES storeyard, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Voltage stablizer for automatic operation, single phase, naturally air cooled, indoor type and designed for input variation between 170 volts to 250 volts with output voltage stablised at 230 volts with accuracy of + 2.5 % and of capacity 5 Kva complete all as specified and as directed by Engineer-in-Charge.
Material and labour in replacement for fabrication, install, testing and commission of wall mounted sheet metal busbar chamber, CPRI approved, grouted with nut and bolts (with proper locking arrangement and holes to distribute circuits) of size 900x 800x 500 mm with copper strip 50 mm x 10 mm (04 Nos) of length 650 mm with approved colour coded and PVC adhesive coated, IP-54 as per IS-13947 protection fixed on insulator with the help of nut/ bolts including provision of 10 Nos 08 mm dia hole with 8 mm dia 50 mm long nut/ bolts with 02 Nos of washer connected with 10 sqmm single core colour coding stranded copper cable with thimble/ lugs including one MCCB, 300 Amps, four pole 3 Phase 36 KA, 415 volt with adjustable thermal and megnetic release complete having adjustable type base frame and equal space around MCCB as incommer one No, making good distrubed surfaces to match with original complete all as specified and directed by Engr-in-Charge.
M&L for earthing complete with galvanised steel earth plate electorde 600 mm x 600 mm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metre below ground level) connected to galvanised earth lead wire 4 mm dia by means of GI bolts nuts, check nuts washer of galvanised iron or steel all as shown in electric plate No 5 of MES SSR Part-I and including excavation & earth work in any type of soil, disposal of soil, providing alternate layers of charcoal and common salt, construction of PCC earth chamber in mix (1:3:6) type C-I with 40 mm thick RCC 1:2:4 type B-1, cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering pipe of 20 mm dia GI light grade and 15 mm dia light grade pipe for earth lead protection and testing on completion, complete including taking down old earthing complete all as specified and as directed by engineer-in-charge.
Note: The unit rate includes for protection pipe 15 mm dia and GI wire from top of the earth plate upto 7.5 metre length.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in deep getting out in any type of soil for stay assembly/ laying of cable/ erection of poles etc complete all as specified and as directed by Engineer-in-charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and as directed by Engineer-in-charge.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed by Engineer-in-charge.
M&L for Sand cushioning to UG cable 8cm thick before laying the cable and 15cm above the cable as specified in SSR to under ground cable including punning down of sand in layer complete all as specified and as directed by Engineer-in-charge. Note: (i) Consolidated/ Punned sand thickness shall be considered for purpose of payment. (ii) Sand shall be same as specified for plastering work.
Supply and Laying of bricks well burnt sub class B (old size) laid flat for cable protection width equal to the length of bricks complete all as specified and directed by Engineer-in-Charge.
Supply, laying & testing of XLPE insulated, armoured, heavy duty LT cable, with stranded aluminium conductor, 1100 volts grade, of size 25 sqmm, 4 core, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete all as specified and directed by Engineer-in-Charge.
Supply, laying & testing of XLPE insulated, armoured, heavy duty LT cable, with stranded aluminium conductor, 1100 volts grade, of size 120 sqmm, 3.5 core, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete all as specified and directed by Engineer-in-Charge.
B B BUILDERS (BID ID -3380121)
Parveen Builders (BID ID -3372319)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .