Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 CrAccepted-AOC | ₹19.3 Cr Quoted ₹19.4 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹19.5 CrRejected-AOC | ₹19.5 Cr | L2 | Rejected-AOC Not being lowest bidder |
| 3 | L3₹20.2 CrRejected-AOC | ₹20.2 Cr | L3 | Rejected-AOC Not being lowest bidder |
| 4 | L4₹20.5 CrRejected-AOC NO 157 14 13TH B MAIN ROAD 1ST STAGE PHASE I GOKULA BANGALORE 560 054 | BANGALORE | BANGALORE | KARNATAKA | 560054 | ₹20.5 Cr | L4 | Rejected-AOC Not being lowest bidder |
| 5 | L5₹22.5 CrRejected-AOC | ₹22.5 Cr | L5 | Rejected-AOC Not being lowest bidder |
| Sl No | Description | Qty | Unit | M/s Imperial Coastal Infra L3 | AFSON ENGINEERS & CONTRACTORS L1 | GOPAL TEKNOCON PRIVATE LIMITED L6 | N RAJEGOWDA and CO L4 | C R R CONSTRUCTIONS L2 | SMLP ASPHALTS L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Lumpsum price worked out by the tenderer for BUILDINGS AND STRUCTURES as listed in Schedule ‘A’ Part-I | 1 | LUMPSUM | 17,29,45,345 ₹17.3 Cr | 15,89,10,000 ₹15.9 Cr | 24,66,04,839.27 ₹24.7 Cr | 17,05,10,000 ₹17.1 Cr | 16,25,00,000 ₹16.3 Cr | 18,87,20,000 ₹18.9 Cr |
| 2.00 | Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II | 1 | LUMPSUM | 4,00,000 ₹4 L | 3,67,600 ₹3.7 L | 3,44,980 ₹3.4 L | 3,11,000 ₹3.1 L | 5,27,560 ₹5.3 L | 3,11,000 ₹3.1 L |
| 3.00 | Lumpsum price worked out by the tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-III | 1 | LUMPSUM | 26,00,000 ₹26 L | 23,99,000 ₹24.0 L | 25,58,551 ₹25.6 L | 30,19,653 ₹30.2 L | 27,00,000 ₹27 L | 39,60,000 ₹39.6 L |
| 4.00 | Lumpsum price worked out by the tenderer for SITE CLEARANCE as listed in Schedule ‘A’ Part-IV | 1 | LUMPSUM | 1,25,000 ₹1.3 L | 1,02,263 ₹1.0 L | 84,868.55 ₹84,868.55 | 97,114 ₹97,114 | 1,00,000 ₹1 L | 1,05,000 ₹1.1 L |
| 5.00 | Lumpsum price worked out by the tenderer for DEMOLITION/ DISMANTLING as listed in Schedule ‘A’ Part-V | 1 | LUMPSUM | 12,99,999 ₹13.0 L | 23,66,000 ₹23.7 L | 19,59,825 ₹19.6 L | 21,29,796 ₹21.3 L | 23,00,000 ₹23 L | 24,25,000 ₹24.3 L |
| 6.00 | Lumpsum price worked out by the tenderer for ROAD, PATH AND CULVERT as listed in Schedule ‘A’ Part-VI | 1 | LUMPSUM | 33,00,000 ₹33 L | 37,88,516 ₹37.9 L | 38,41,076.75 ₹38.4 L | 36,83,709 ₹36.8 L | 39,76,700 ₹39.8 L | 40,33,000 ₹40.3 L |
| 7.00 | Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VII | 1 | LUMPSUM | 4,50,000 ₹4.5 L | 4,60,016 ₹4.6 L | 3,55,242.75 ₹3.6 L | 4,74,211 ₹4.7 L | 4,95,000 ₹5.0 L | 5,10,000 ₹5.1 L |
| 8.00 | Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VIII | 1 | LUMPSUM | 11,00,000 ₹11 L | 9,41,412 ₹9.4 L | 7,11,929.3 ₹7.1 L | 9,00,000 ₹9 L | 4,85,000 ₹4.8 L | 5,10,000 ₹5.1 L |
| 9.00 | Lumpsum price worked out by the tenderer for RAIN WATER HARVESTING as listed in Schedule ‘A’ Part-IX | 1 | LUMPSUM | 3,50,000 ₹3.5 L | 3,55,339 ₹3.6 L | 3,19,048.12 ₹3.2 L | 3,03,093 ₹3.0 L | 3,15,000 ₹3.1 L | 3,38,000 ₹3.4 L |
| 10.00 | Lumpsum price worked out by the tenderer for COMPOUND WALL, FENCING AND GATE as listed in Schedule ‘A’ Part-X | 1 | LUMPSUM | 16,50,000 ₹16.5 L | 20,43,634 ₹20.4 L | 16,67,647.99 ₹16.7 L | 18,68,500 ₹18.7 L | 19,25,000 ₹19.3 L | 20,55,000 ₹20.6 L |
Tender Value
₹19.9 Cr
EMD Value
₹13.2 L
Closing Date
6 Mar 2025, 6:00 pmClosed
Chief Engineer Chennai
CHIEF ENGINEER CHENNAI ZONE ISLAND GROUNDS CHENNAI-600 009
PROVN OF SINGLE LIVING ACCN FOR 200 X WOMEN CANDIDATES AT SSB BANGALORE
2024_MES_690012_1
88556/E8
Open Tender
Civil Works
549 days
Bangalore
As per tender documents
8 documents required · 8 mandatory
₹3,000
Yes
Garrison Engineer (Project) Bangalore
₹13.2 L
Yes
10 Sept 2025
24 Dec 2024
12 Mar 2025
24 Dec 2024
6 Mar 2025
10 Feb 2025
24 Dec 2024 - 30 Dec 2024
Amount
Lumpsum price worked out by the tenderer for BUILDINGS AND STRUCTURES as listed in Schedule ‘A’ Part-I
Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II
Lumpsum price worked out by the tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-III
Lumpsum price worked out by the tenderer for SITE CLEARANCE as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for DEMOLITION/ DISMANTLING as listed in Schedule ‘A’ Part-V
Lumpsum price worked out by the tenderer for ROAD, PATH AND CULVERT as listed in Schedule ‘A’ Part-VI
Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VII
Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VIII
Lumpsum price worked out by the tenderer for RAIN WATER HARVESTING as listed in Schedule ‘A’ Part-IX
Lumpsum price worked out by the tenderer for COMPOUND WALL, FENCING AND GATE as listed in Schedule ‘A’ Part-X
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-XI
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-XII
Lumpsum price worked out by the tenderer for COOLING APPLICANCES as listed in Schedule ‘A’ Part-XIII
Lumpsum price worked out by the tenderer for SOLAR WATER HEATER as listed in Schedule ‘A’ Part-XIV
Lumpsum price worked out by the tenderer for FIRE FIGHTING, FIRE ALARM AND DETECTION SYSTEM as listed in Schedule ‘A’ Part-XV
Lumpsum price worked out by the tenderer for LIGHTNING PROTECTION as listed in Schedule ‘A’ Part-XVI
Lumpsum price worked out by the tenderer for LIFTS as listed in Schedule ‘A’ Part-XVII
SCHEDULE 'A' PART XVIII (MISCELLANEOUS ITEMS) Note: This schedule is not pre-priced by MES
DEMOLITION/ DISMANTLING
Taking Down existing old unserviceable MCBs of any capacity and type complete all as specified and directed.
Taking Down existing old unserviceable DBs/ MCCBs of any capacity and type complete all as specified and directed.
Taking Down existing old unserviceable Earthing of any description and type complete all as specified and directed.
Taking Down existing old unserviceable GI pipe of any description and size complete all as specified and directed.
Taking Down existing old unserviceable submain wiring alongwith conduit of any type concealed/ surface wiring complete all as specified and directed.
INTERNAL WATER SUPPLY
Supply and fix 15 mm (ANGULAR) stop valves, cast copper alloy, chromium plated, fancy type, long shank and cup ( concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for uniform and fixed complete all as specified and as directed
INTERNAL ELECTRIC SUPPLY
M&L for Point wiring complete with 1.5 sq mm single core PVC insulated FRLS unsheathed cable 1100 volts grade with multi stranded copper conductor confirming to IS-694 1990 wih ISI marked (for phase, neutral and earth) in and including stove enamelled Steel conduit with ISI Mark of minimum 20mm dia and all conduit accessories concealed including cutting/ chases in wall/ceiling/fixed to roof/truss/columns etc and including factory made branded make embossed galvanised steel pressed terminal modular box 1mm thick alongwith suitable size modular cover plate with frame for fixing modular switches and sockets, fan regulators etc. of suitable size modules and the earth wire to be connected to common earth dolly complete all as specified and directed for One light point controlled by one modular switch 6A one way :- Note: Location of light points, 6 Amp socket points and light fittings may be decided by Engr-in-charge as per site/user requirement
All as described in item No. 24 above but One Ceiling/Exhaust fan point controlled by one modular switch 6A
All as described in item No. 24 above but One 3 pin socket out let 6 Amps on independent board
All as described in item No. 24 above but One 3 pin socket out let 6 A on same board with other switches
All as described in item No. 24 above but One light point controlled by two 2 - way modular switch 6 A
M&L for Point wiring complete all a specified with 1100 Volts grade 4 sq mm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor conforming to IS 694 1990 with ISI marked (for phase, neutral and earth)in and including stove enamelled Steel conduit ISI Mark of minimum size 20mm dia all accessories concealed including cutting/ chases in wall/ceiling/fixed to roof/truss/columns etc and including factory made branded make embossed galvanised steel pressed terminal modular boxes 1mm thick for fixing modular sockets of suitable size modules and the earth wire to be connected to common earth dolly all as specified and as directed. All as specified and as directed for One three pin modular socket outlet 16 amps on independent board
M & L for sub main wiring with 1100 volts grade multistranded FRLS copper conductors, four runs of single core 10 Sqmm along with 10 Sqmm PVC insulated one run single core multistranded copper conductor cable as earth continuity conductor run along with suitable size of stove enamelled Steel conduit all as specified and as directed.. Notes:- (i) Five runs of 10.00 sqmm copper wire and one run of suitable size of metallic rigid steel conduit medium grade shall be considered as one unit length. (ii) Colour code for sub main wiring shall be red, yellow and blue for phases, black for neutral and green for earth.
M & L for sub main wiring with 1100 volts grade multistranded FRLS copper conductors, two runs of single core 6 Sqmm along with 6 Sqmm PVC insulated one run single core multistranded copper conductor cable as earth continuity conductor run along with suitable size of stove enamelled Steel conduit all as specified and as directed. Notes:- (i) Three runs of 6.00 sqmm copper wire and one run of suitable size of metallic rigid steel conduit medium grade shall be considered as one unit length. (ii) Colour code for sub main wiring shall be red, yellow and blue for phases, black for neutral and green for earth.
M & L for sub main wiring with 1100 volts grade multistranded FRLS copper conductors, two runs of single core 2.5 Sqmm along with 2.5 Sqmm PVC insulated one run single core multistranded copper conductor cable as earth continuity conductor run along with suitable size of stove enamelled Steel conduit all as specified and as directed. Notes:- (i) Three runs of 2.5 sqmm copper wire and one run of suitable size of metallic rigid steel conduit medium grade shall be considered as one unit length. (ii) Colour code for sub main wiring shall be red, yellow and blue for phases, black for neutral and green for earth.
S& F slim surface mounted round 12 W light fitting LED panel aluminium die cast body with premium diffuser to ensure glare free &even distribution of light 12W, 220V,AC, 6000 K LED light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete
S&F reading light (Bed Side) wall mounting 7 W Cool day light CCT of 3000K 400 Lumen output aluminium body with white powder coating complete all as specified and directed make PhilipsCat No 31437 or equivalent in Havells or Wipro
S&F MCB DB VTPN 8 way having degree of protection as per IP 43 with metal door (double door) 415 Volts complete with 200 Amps rated copper bus bar with neutral link with provision for 4 Pole MCCB as incomer and MCBs as outgoing incoming specified and as directed.
S&F MCCB 4P 100 Amps, 415 V, Adjustable type, with breaking capacity 25 KA complete all as specified and as directed
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 metre long by means of nuts, bolts, thimbles, check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed.
S&F security / street light bracket made of GI medium grade tube of 40mm dia, 1.5 metre long bend to shape to form an angle of 120 degree and fixed to wall / pole with 2 Nos of MS clamps 25 x 4mm of required length/size including suitable nuts and bolts and painting two coats of aluminium paint over one coat of red oxide primer complete all as directed.
RAIN WATER HARVESTING
M & L for Perforated PVC pipes single socketed in any length 110mm bore laid in trenches with rubber ring joints all as specified and as directed.
Drilling of bore holes 150mm dia for fixing of pipe all as specified and as directed.
M & L for gravel loose filled in layers all as specified and as directed.
M & L for 20mm size stone aggregate, loose filled in layers all as specified and as directed.
M & L for 40mm size stone aggregate, loose filled in layers all as specified and as directed.
M & L for 63mm size stone aggregate, loose filled in layers all as specified and as directed.
EXTERNAL ELECTRIC SUPPLY
Supplying, fixing, commissioning and testing of 11KV, 350 MVA, 630 Amps 4 way outdoor type RMU (Ring Main Unit) of 1 OD + 3 VL Right side extensible consisting 1 nos load break switch of 630 Amps and 03 Nos of 630 Amps VCB with protection and metering CTs complete with PCC foundation for mounting including lettering the breaker it enamel paint and writing single line diagram for each panel as per following specifications complete all as directed. Make :- Schneider/ ABB/Siemens
(i) Type - outdoor type RMU (ii) Operating Voltage - 11 KV (iii) Rated Frequency - 50 Hz (iv) Rated start time current - 20 KA (v) Operation - Motorized (vi) VCB - 630 Amps (Fixed Type) (Vii) Load Break System - 630 Amps (Fixed Type) (Viii) Protection - Self powered O/C and E/F Relay protection with suitable protector CTs for distribution transformer (ix) Bus Bar - 630 Amps
(x) Class of Protection - (a) IP 67 for SF6 gas Tank (SS) (b) IP 2X for front cover (c) IP 54 for outdoor enclosure
M & L earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc. of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth electrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note :- The cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI light grade is deemed to be included in quoted unit rate.
M/L for LT cable route indicators Oval Shaped 200x150x6 mm cast Iron precast with engraving "LT MES CABLE" embedded with PCC 1:3:6 Type C1 including necessary excavation, returning filling & removal of soil complete as specified and as directed.
Supply and fix FRP pole box of size 168X253x115mm ,thermoplastic,polycabonate,IP-66 complete with 4 pole 32 A connector, Double compression glands-2 Nos, MCB SP 6 Amps mounted with GI clamps of suitable size with nuts and bolts on street light pole all as specified
(i) Aluminium bus bar 3 phase & neutral of capacity 400 Amps (ii) MCCB 4 Pole 250 Amps 35 KA-01 No ( Incoming) (iii) MCCB 4 Pole 63 Amps 25 KA-01 No ( Outgoing for DG Panel) (iv) MCCB 4 Pole 160 Amps 25 KA-01 No ( Outgoing for APFC) (v) MCCB 4 Pole 200 Amps 25 KA-02 No ( Outgoing for Bldg & Spare) (vi) LED phase indication lamp for 3 phase-01 No
(i) Aluminium bus bar 3 phase & neutral of capacity 100 Amps (ii) MCCB 4 Pole 63 Amps 25 KA-01 No ( Incoming) (iii) MCCB 4 Pole 32 Amps 10 KA- 04 Nos. ( Lift + Fire pump + PH+ Spare) (iv) MCB SPN 16 Amps 10 KA -02 Nos (Street Light) (v) Timer switch Single phase with contactor 16/ 20 amp -01 No (vi) LED phase indication lamp for 3 phase-01 No
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding techniques and necessary machines including providing of HDPE pipes of 150 mm dia suitable for 0.4MPA working pressure complete all as specified and directed.
Design, manufacture, supply, install, test and commission of Automatic Power Factor control panel 60 KVAR capacitor bank in 8 steps as indicated below with microprocessor based controller units suitable for operation on AC 415 V , 50 Hz ,supply, suitable for installation outdoor weatherproof type, front with hinge type door and locking arrangement bottom with detachable sheets for cable entry/exit , top with sloping canopy fabricated with 3.15 mm thick MS sheets suitable size to install following switchgears/items, powder coated both inside and outside, complete panel board shall be installed on suitable PCC pillar with bolts and nuts grouted into pillars and comprising following switchgears/ capacitors control gear etc. all as specified and as directed.
(a) Incomer MCCB TPN 100 Amps 35 KA - 01 No (b) Current Transformer 100/5 Amps - 03 Nos (c) Aluminium bus bar insulated TPN 200 Amps - 01 set (d) Capacitors 20 KVAR super heavy duty long life for industrial load - 03 Nos Including suitable capacities contactors, MCBs , Fuses, Relays, Digital type indicating meters for voltage, current, PF etc. complete internally prewired with copper conductor.
(EXTERNAL WATER SUPPLY )
M&L for Centrifugally cast (Spun) Ductile Iron pipes with socket & spigot end centrifugally, class K-7 conforming to IS: 8329:2000 marked with and including Rubber Gaskets used with Push -on -jointing confirming to IS 5382 in any length laid in trenches with including all fittings of size 100 mm dia bore all as specified.
Supply, install, test and commission of Centrifugal electrically driven self priming monoblock pump set with cast iron impeller capable of pumping 600 LPM at 39 Mtr head, squirrel cage TEFC induction motor 3 phase, 415V AC,50 Hz suitable for delivery 600 LPM at 39 Mtr head coupled on common base channel including provision of suitable PCC foundation, nuts and bolts, copper cable from starter to motor through PVC flexible pipe , suitable size of suction pipe not less than 20 feet or as reqd at site, Foot valve, Air release valve complete all as directed and specified
M&L for construction of valve chamber of internal dimensions 900x900x900 mm depth with PCC foundation, 1:4:8, Type D2, brick work built in cement mortar 1:4 using of sub class B bricks, PCC coping at the top of the chamber walls with PCC 1:2:4, Type B1, plastering 15 mm thick in cement mortar 1:4 including MS sheet cover 3mm thick with angle iron frame 50x50x6mm locking arrangement complete with painting on steel surface with two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earthwork all as specified and directed.
(DG SET )
Supply, installation, testing and commissioning of Silent Diesel Engine Generating Set of 58.50 KVA / 46.80 KW net capacity after all due de-rating factors as per relevant lSI standard, 415 volts, 3 phase, 0.8 Power factor, 50 Hz, 4 wire system as per IS 10001/10002 comprising of KOEL 58.50 KVA or equivalent, developing 74.40 BHP @ 1500 RPM, Air Cooled, electric start coupled to alternator as per IS 13364 mounted on a common base frame with standard control panel for automatic starting on main control panel having meters, with emission control device to control the PM within range as prescribed by NGT/ norms published vide GSR 804(E) dt 03.11.2022 of GoI and updated till date on procurement and CPCB approved acoustic enclosure suitable for ambient condition at Bangalore with integral fuel tank with battery and leads and accessories complete including required PCC foundation as per manufacturers instruction and confirming to conditions as per IS provisions:-
(A) Alternator :- Standard design alternator rated at 58.50 KVA net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of ± 1 % at rated voltage from no load to full load. The alternator shall be confirming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in ± 1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS/IS – 4722 and as per the following provisions:- Make:- KIRLOSKAR/JYOTI / STAMFORD/CATERPILLAR
(B) Diesel Engine: - Adequate capacity Diesel engine suitable for 58.50 KVA coupled drive independently above alternator and after considering derating as per site conditions after generating and reducing power consumed by accessories, directly coupled through flexible coupling, multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for one hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under Make :- KIRLOSKAR/CUMMINS / CATERPILLAR (GEMCO)
(a) Fly wheel with housing (b) Cooling system :- Mounted radiator with fan & belts. (c) Cooling pump: - Centrifugal type belt driven. (d) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia as per manufacture standard with MS pipe light grade up to and away two meters height from top of enclosure including necessary angle iron frame supports from floor to the bottom of exhaust pipe from the enclosure covered with mineral wool of thickness 50mm rapped with chicken wire mesh of size 2.25mm and aluminium sheet of 24 SWG to be complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type Exhaust manifold Silencer: Residential type Bellows
(C) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch/nozzles/ governor mechanical type capable for 1 % speed /frequency regulation. (i) Fuel filters (ii) Fuel hoses (iii) Lub oil System :- (iv)Lubricating oil filter (v) Lubricating oil pump (vi) Air Intake System :- (a) Air intake Manifold (b) Air cleaner dry type (a) Starting System :- Electric Self starter with maintenance free batteries including battery charging alternator. (b) Batteries:- 1 No. Maintenance free Battery of suitable AH capacity complete with copper conductor multistranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified. Make:- EXIDE / AMRON / Produced by original DG set manufacturers
(i) Starter gear ring (ii) Start and stop push button (iii) Ignition key / Switch (iv) Handling and operation: Salient features of accessories shall be as under: (a) Radiator with blower fan (b) Corrosion inhibitor coolant (c) Paper element filters for fuel, lub oil and by pass. (d) Electronic governor controlled direct fuel injection system (e) Fly wheel housing and fly wheel.
(E) Generator Monitoring Panel: Comprising of following:- (a) Microprocessor based integrator generator set monitories, metering, protection and control system with built torque matched volts/H3 over load control. (b) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown)
(c) Alternator protection parameters like under voltage, over current, under frequency, over frequency ( alarm & shut down) (d) Relay drivers for remote annunciations (e) Cyclic cranking (f) Auto/manual start stop (g) Alternator trim adjustment from the front key pad (h) Operates within a temperature range 0- 50°C and humidity up to 95% (j) Remote monitoring capability through separate interface modules k) Genset metering parameters like lube oil pressure, coolant temperature, engine speed(rpm), run hours, DC voltage, 3 phase volts and 3 phase amperes, frequency, KW, KVA, power factor
(l) Safety Controls : - Engine low lube oil pressure, high water temperature and over speeding of engine. (m) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling fly wheel housing. (n) Accessories :-A VM Pads built or separately mounted to manufacturer base frames. (o) Base Frame: - Made out of ISMC 200 of sturdy design made of MS channel with necessary reinforcement and predetermined holes.
(p) Fuel Tank :- Daily service fuel tank of capacity minimum 08 hrs running storage (Inbuilt) made out of 3mm thick (Heat Retardant) sheet top and bottom with calibrated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity and connected pipe line should be installed with in built inside the acoustic enclosure is inclusive of the cost of DG Set and is as per manufacturer design. (q) Deliverables:- Confirms the norms established by CPCB.
(F) AMF PANEL:- (a) Auto Main Failure (AMF) panel made out of 2 mm thick CRCA sheet, powder coated of conforming to IS 8623 totally enclosed dust and vermin proof with front and rear openings of 415 Volts, 3 Phase,4 Wire, AC 50 Hz having aluminium bus bar capacity required to carry current at 100% load of 58.50 KVA DG set with three phase and half neutral colour coded, prewired with copper flexible cable, be all as specified with the following accessories, control cable from Gen set to AMF panel:
(i) 100 Amps, 4 pole contactor - 2 Nos. (ii) MCCB, 4 Pole 63 Amps, 25 KA-2 Nos for both supplies suitable fuse links. (iv) CTs 50/5A for both the supplies. (v) DC Ammeter. (vi) DC Voltmeter. (vii) Push buttons. (viii) Indication Lamps. (ix) 2 over load+ earth leakage relay.
(x) Multi functional digital meter for KWH,KVA,KW,Amps,volts, frequency, power factor etc. (xi) SMPS Battery charger 12V, with trickle & Boost charging (xii) On/ Off switch. (xiii) Automatic/manual switch. (xiv) Hooter. (xv) Voltage sensing relay. (xvi) Six window enunciator for fault indications. (xvii) Electro magnetic relays. (xviii) Metering required in DG set :- A, V, Hz, KVA, KW, PF & KWH Metering required in mains :- A, V, Hz.
(G) Acoustic enclosure: CPCB approved enclosure is free standing floor mounted factory built and modular in construction to facilitate easy assembly at work site and will be drop over housing type. It will consist of acoustically treated panel housed in sheet steel will provide easy access for maintenance, repairs and operation. The enclosure is custom built to suit conditions, with the following features:- (a) Custom built product for various equipments, with ensure the optimum performance without duration.
(b) Rugged in construction maintenance free and modular designs which facilitate easy at site. (c) 16 SWG (1.6 mm) thick CRCA sheets to be used for enclosure panel to ensure longer life against weathering action. High quality acoustic insulation materials to be used as per IS 8183 for maximum sound absorption. Acoustic layers are supported by perforated sheets. (d) Sheet metal components of the enclosure should undergo various stages of surface treatment prior to painting which leads to be better life of the enclosure against weathering action. (e) Special paint treatment with pure polyester powder/epoxy to be provided for better weather resistance.
(f) Well designed ventilation system to be provided to pump up the heat in the chamber efficiently. (g) For effective acoustic / weather sealing a special type weather sealing gaskets, new frame rubber gaskets to be used. (h) Working space is to be provided around tube equipment for easy maintenance / repairs. (j) Necessary cut out provision for entry and exist of fuel lines cable to be incorporated in the enclosure as per the requirement. (k) A see through transparent window (glass or acrylic) in front of engine panel to be provided for monitoring the operation. (l) Ducting if required, bellows, mechanical hardware like locks, hinges fasteners etc to be provided. (m) Deliverables. 75 dBA @ imtr at 75% load under free field conditions. The temp inside tee enclosure will be within as per manufacturers recommendations above ambient temp.
(n) The enclosure should be provided with bulk head light fitting for inside illumination (o) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated platform. (p) The DG Set should be provided with external Emergency stop push button. (q) The acoustic enclosure parts shall be of powder coated after pre treatment process. (r) The powder coating shade should be Genset Green. The base frame should be painted with epoxy based black shade.
COOLING APPLAINCES
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA all as specified and as directed.
SOLAR WATER HEATER
Sub main wiring with PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 6.0 Sqmm, earth continuity conductor of size 6.0 Sqmm to be drawn through and including PVC conduit 20mm dia medium Grade surface in walls/roof/floors all as directed by Engineer in Charge. Note:- Two runs of 6.0sqmm cable and one run of 6.0 sqmm cable and one run of PVC conduit with clamping shall be measured as one unit.
LIFTS
Earthing with copper earth plate electrode 60 cm x 60 cm x3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metre below normal ground level) with top edge of earth plate not less than 1.5 metre below normal ground level connected to main earth lead Copper strip 20 mm x 3mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 5 of MES Schedule Part I 1991, GI earth lead protected by GI pipe 40 mm dia light grade, providing and connected to earth test point with & including necessary excavation & earth works in any type of soil, returning filling, disposal of surplus soil to 50 metre, filing with mixture of charcoal and common salt upto 15 cm above top edge of earth plate, pit of PCC 1:2:4 with precast cover of RCC 1:2:4, watering arrangement with GI funnel, 20 mm dia GI light grade watering pipe, earth test point terminal block, commissioning & testing complete.
Note : Main earth lead beyond 7.5 metre measured and paid for separately.
FIRE FIGHTING, FIRE ALARM AND DETECTION SYSTEM
M & L for Two wire addressable talk back speaker with inbuilt driver. The addressable talk back speaker shall have a call button for unit activation, signalling the support control panel to indicate the callers location. Clear voice pick up shall be ensured within a minimum 1 Meter distance from the units microphone and the speakers standing position. The unit shall be equipped with an LED that blinks in normal conditions and glows Steadily upon activation. Activation can occur through the built-in push button or remotely from the control panel. Both the control panel and talk back speaker shall continuously scan for the healthiness and cable connectivity to ensure integrity compliance. The Speaker shall have a capacity of 5 watts, serving both talkback and PA functions. It shall have ABS Housing along with back box. It shall be able to produce 70dB sound at 1 Mtr distance
M & L for Two wire addressable speaker with LED light flash/Beacon suitable for targeted announcements and equipped with a LED light flash ( to cater to hearing-impaired occupants). The unit shall be equipped with an LED that blinks in normal conditions and glows steadily upon activation. Both the control panel and speaker unit shall continuously scan for healthiness and cable connectivity to ensure integrity compliance. the speaker must have a minimum capacity of 5 watts with max voice current of 100mA. It shall have ABS housing along with Back box. it shall be able to produce 90 dB sound at 1 Mtr distance
M & L for Two wire addressable speaker driver module with built in audio amplifier and along with 12-15W horn type speaker ( Maximum voice current of 300 mA) for outdoor use such as parking areas, assembly areas etc. & with the Back box. It shall be able to produce minimum 90 dB sound at 1 Mtr distance
M & L for remote repeater panel similar to main control panel capable of full supervision of all inputs an network integrity, having colour touch screen display, environmental adjustment control to maximise LCD legibility, LED status indicator. (For power supply and OFF normal conditions)
M & L for low smoke zero halogen(LSOH) flame retardant fire alarm cable 2C x 1.5 Sqmm conforming to BS-7629-1, BS-6387 and BS EN 50200 and rated for 500V drawn through and including concealed PVC conduit and accessories of min 20mm dia NB and having plain annealed stranded copper conductor with primary insulation of glass mica fire resistant tape and secondary insulation of high performance silicon rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheathed conforming to BS 7655, suitable for operating temp -30 deg centigrade to +70 deg centigrade and min bending radius being six time the overall cable diameter, red in colour, including laying termination and ferruling complete all as specified and as directed by Engineer-in-Charge.
M & L for fire survival cable of size 3 core 16 sq mm with stranded annealed bare copper conductor, mica tape wrapped for heat resistance up to 950deg centigrade, GI strip wire armoured and zero halogen outer sheathed XLPE insulation cable all as directed. Make: Havells/ KEI/ RR Kabel
M & L for PN 1.6 rated 100 mm NB polypropylene vortex inhibitor suction lift, conforming to BS 4504 with stainless wire mesh, bolts, nuts and washers, etc. complete all as specified and directed
M & L for PN 1.6 rated 100 mm NB CI 'Y' -type strainer for suction conforming to IS 907: 1984 with SS filter screen and flange drilling standard end connection conforming to IS 1538: 1993 and necessary accessories for suction side of fire pumps complete all as specified and directed. (at pump suction header).
M & L for PN 1.6 rated 100 mm dia CI puddle flange designed & manufactured as per BS 1560-3.1 & BS 4504 for suction of fire pumps from water tank all complete all as specified and directed
S & F of Signage of 5Watt hanging / surface type with matt black/ snow white finish after phoshochromate treatment having size 300 mm X 150 mm reading "EXIT" within arrow showing the direction in 12.5 mm block letters in Green and white background, self illuminated properly spaced to provide good legibility located directly in corridor near to each staircase and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level. These lights shall emit the maximum light required even during the electricity supply or in Black out period with high energy efficiency manufactured using superior quality Aluminium Extrusion body raw material all as specified and as directed.
S & F of Signage of 5Watt hanging / surface type with matt black/ snow white finish after phoshochromate treatment having size of 500 mm X 500 mm, indicating the "Floor Number" in bold type and at 75 mm high numerals in red and white background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, posted and maintained within each stair enclosure on every floor, securely attached to the stair side of the door in a way that the bottom of the sign is not above 1.5 m from the finished floor level all as specified and as directed.
S & F of Signage of 5Watt hanging / surface type with matt black/ snow white finish after phoshochromate treatment having size of 450 MM X 150 MM reading "FIRE EXTINGUISHER with symbol" in 12.5 mm block letters in White and Red background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, properly spaced to provide good legibility located directly in corridor near to each Manual call point/Fire Extinguisher and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level all as specified and as directed.
S & F of Signage of 5Watt hanging / surface type with matt black/ snow white finish after phoshochromate treatment having size of 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the "STAIRCASE with symbol and direction" by an alphabetical letter in bold type and at 75 mm high letters in red and white background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level all as specified and as directed.
S & F 4 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder, Operating temperature ranging from300°C to + 550°C, Discharge time not less than 45 sec , throw not less than 4 meters with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed
S & F of 3 kg light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder, Test Pressure not less than 250 kgf / Sq. cm,Operating temperature ranging from 300°C to + 550°C with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed
Supply & Installation of Water Stored pressure type Fire Extinguisher of 9lit capacity, fitted with discharge control valve (Squeeze grip type) CE marked and pressure gauge, with discharge hose and open nozzle and supplied complete with initial charge as per IS:15683 with ISI mark and wall bracket. Fire Rating 2A
Supply and fixing of Mechanical foam type fire extinguishers, 9 Ltr capacity, IS:15683 : 2006, complete.
Supply & fixing of 4 Nos of 9 lts capacity round bottom sand /water buckets along with round bottom type , enamel painted white inside and red outside & letter fire in black outside & handle with mounting bracket along with suitable MS stand to install the buckets as per the local fire standards
Supply & Fix indoor type wall-mounted lockable hose cabinet of size 2100 mm (H) x 950 mm (L) x 750 mm (D) suitable to house 2 Nos. of 15 m RRL hose and 2 Nos. branch nozzles, Swing type first aid hose reel, instantaneous gunmetal outlet - 01 No, fire extinguishers etc and made of 18 gauge MS sheet with double door & 3 mm thick glazed glass with water proof rubber beading, red out side and white inside with two coats of enamel paint over a coat of primer, having "HOSE CABINET NO." painted on the inner face of the glass in 50 mm size block letter, including the cost of break glass box containing the key of the cabinet complete all as specified and directed.
[SEWAGE DISPOSAL]
Supply and laying 150mm internal dia DWC HDPE SN-8 pipes confirming to IS 14930 part-2 / IS 16025 Part-24, laying including all necessary specials, cutting and jointing as specified and directed
PHASE - II COMPREHENSIVE MAINTENANCE OF LIFTS INSTALLED VIDE SER ITEM No. 1 OF SCHEDULE 'A' PART XVII FOR A PERIOD OF 03 (THREE YEARS) AFTER COMPLETION OF DEFECTS LIABILITY PERIOD OF PHASE - I
NOTES FOR BOQ SER ITEM NOS 82 TO 85
[a] The contractor shall be required to employ required tradesmen with sound knowledge and adequate experience. All the manpower employed shall report to Office of AGE [E/M]/ Complaint Cell for day to day maintenance and efficient functioning of Lifts. [b] The contractor shall carryout the comprehensive maintenance of the lifts catered under subject work through the Original Equipment Manufacturer of that lift or from their accredited / authorised agencies only. The lowest bidder shall submit MoU from the Original Equipment Manufacturer of the Lift or from their accredited / authorised agencies to provide technical support, trained persons for maintenance & testing and spares before commencement of the work to GE. The spares shall be of the make as per existing or as per the OEM.
[c] The rate quoted for comprehensive maintenance includes for preventive maintenance by carrying out routine checks by skilled personnel as specified in Particular specifications herein after and breakdown services by supplying and replacement of all Major/ Minor Spares viz. Mechanical / Electrical / Electronic spares, LED Lights/consumables like lubrication oil/ grease/ hardwares like bolts, nuts, etc. as and when required for trouble free, smooth and efficient functioning of lifts including overhauling as and when required to all mechanical parts of lifts, repair/ maintenance of Gear Unit, repair / maintenance of Door Drive, Controllers, Pulleys, Limit Switches, Relays, door rollers, door belts, etc. complete all as directed. All the safety measures including ARDs shall be ensured for serviceable condition through out the contract period and cost of their spares, batteries etc. shall deemed to be included in the rate quoted and Nothing extra shall be paid on these accounts.
[d] The rate quoted shall be deemed to be inclusive of testing of each lift by Licensed Lift Inspector of Government of Karnataka once in a year for worthiness and safety of the lifts. Certificate issued by the Licensed Lift Inspector shall be submitted to the Engineer-in-Charge and a copy of Certificate shall be displayed in all Lift Cabins as directed. [e] Emergency Light and necessary tools shall be available in a tool box in the shift for smooth functioning of lifts. [f] The contractor shall abide by the latest Labour Rules and Minimum Wages Act. [g] Wages paid by the contractor to the persons employed shall not be less than the minimum wages fixed by State / Central Government from time to time whichever is higher. [h] The contractor is responsible for making subscription towards Insurance, EPF, ESI, Labour Welfare Cess etc., as applicable and shall pay Gratuity, Bonus etc to the Workmen as per existing Labour Rules / Acts / Regulations and rate quoted shall be deemed to be included for the same.
[j] The contractor shall provide the workmen protective clothing / gear. The contractor shall also provide shoes to the workers and the persons shall not be allowed to enter the work site without wearing shoes. [k] The contractor shall be responsible for all Accidents / Injuries happening to the workmen. Any accident causing Minor / Fatal Injury, Partial Disability due to any untoward incident or non-adherence to Safety and IE Regulations or fault in maintaining of Lifts System / Safety Mechanism or on account of any mishandling / wrong operation / lack of knowledge of safety precautions or on account of any circumstances beyond his/their control, the contractor shall be solely responsible for settling all claims of compensation to the deceased, failing which department will have a right to recover any sum indicated / claimed by Labour Commissioner/ Court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Contractor shall provide first aid boxes to meet any emergency situations.
C R R CONSTRUCTIONS (BID ID -3245571)
M/s Imperial Coastal Infra (BID ID -3241030)
N RAJEGOWDA and CO (BID ID -3245314)
SMLP ASPHALTS (BID ID -3241790)
GOPAL TEKNOCON PRIVATE LIMITED (BID ID -3244866)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid