Maj Rahul Rawat
Garrison Engineer Utility Bathinda Mil stn
REPAIR MAINTENANCE OF STREET LIGHTS SECURITY LIGHTS IN MD ACCN AND OTM ACCN OF ZONE B UNDER GE (UTILITY) BATHINDA MILITARY STATION
2020_MES_359352_1
CA NO GE (U) BTD - 09/2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer Utility Bathinda Mil stn
Class D Cat b (i)
10 documents required · 10 mandatory
₹500
Garrison Engineer Utility Bathinda
₹60,000
Yes
8 Sept 2020
20 Jul 2020
21 Aug 2020
20 Jul 2020
20 Aug 2020
5 Aug 2020
20 Jul 2020 - 31 Jul 2020
Amount
Checking / Testing including taking down of street light fitings , any type from poles / walls to find out defects on site and repairing etc and repairing by changing the defective parts including minor repairs to cable connection / loose connection / necessary cleaning the bowl / perpex cover where provided including refixing of street light fiting its original place / position after cleaning complete all as specified and as directed by Engineer -in-Charge. Note : (i) Spares of light fittings shall be measured & paid separately under serial item no. 2.00,3.00 & 4.00 of BoQ as a supply only items. The labour element of fixing of serial item no. 2.00,3.00 & 4.00 of BoQ is included in this item and nothing shall be paid extra on this account. (ii) The T&P ,Vehicles and necessry ladders etc. for North side area & South side area will be arranged by the contractor at his own arrangments . The rates of this aspect is included in this item and nothing shall be extra paid on this account . (iii) During currency period of contract , contractor shall depute one Electrician & two helpers for North side area & one Electrician & two helpers for South side area and one electrician & two helpers for Officer Md Accn, Corps HQ & Main road etc respectively for attending the complaints regularely.The rates of this aspect is included in this item and nothing shall be extra paid on this account . Please note one time payment shall be made to contractor for this item.if any fault / defects occured , contractor shall rectify / replace the same without any extra cost in terms of condition 46 of IAFW-2249 of General condtion of contracts.
Supply only LED driver suitable for 45 Watts LED with 65 protection, as per IS.
Supply only LED driver suitable for 60 Watts LED with 65 protection, as per IS.
Supply only LED driver suitable for 120 Watts LED with 65 protection, as per IS.
Taking down and repair of street lights fitting in MES store yard of AGE Electric supply by the help of one electrician and one helper, complete all as specified and as directed by Engineer-in-Charge. Notes :- (i) During currency period of contract , contractor shall depute one Electrician and one helper for attending the complaints regularely.The rates of this aspect is included in this item and nothing shall be extra paid on this account . Please note one time payment shall be made to contractor for this item.if any fault / defects occured , contractor shall rectify / replace the same without any extra cost in terms of condition 46 of IAFW-2249 of General condtion of contracts. (ii) The T&P ,Vehicles and necessry ladders etc. for North side area & South side area will be arranged by the contractor at his own arrangments . The rates of this aspect is included in this item and nothing shall be extra paid on this account .
Material and Labour driver protection circuit of 10 KA, voltage range input 180-300 volt, output 230 volt ± 5 % tolerance, over voltage, under voltage & overload protection system complete suitable for 40 watts to 200 watts LED fittings as per IEC-60364 & 60898.
Material and Labour LDR based cicuit control as per exising for normal LED street lights fittings the cicuit operated on less than 5 Lux & off more than 10 Lux input supply 100 to 300 volt and output 230 volt ± 5% tolerance complete protection of over current and suitable for 40 watts to 200 watts LED fittings as per IEC - 60898 & 60617.
Supply and fixing energy efficient LED Flood light fitting of 120 Watt including No. of LED Flood light bulbs as per manufacturers instructions for lighting of 120 watt ,epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection for cable connection complete all as specified and directed by Engineer in charge. Make Polycab Wires Pvt. Ltd (Poly Cab) Cat Part No. PAR0206012 PCGLF T1 01 12057 or equivalent cat part of makes as specified in Appendix ‘A’ approved list of makes / manufacturers here-in-after and approved by GE. Note :- (i) Cable for connection of LED Light fitting shall be measured and paid under serial item no. 17.00 of BoQ here-in-after .
Supply and fixing energy efficient LED street light fitting of 45 Watt seasonal RTC control with dimmable type, including No. of LED bulbs as per manufacturers instructions for lighting of 45 watt , epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection for cable connection complete all as directed by Engineer-in-Charge. Make- HALONIX CAT NO. HLCGRFSL1003/ WIPRO LR0245W/HPL CCMSSL45W/HAVELLS CCMSLS45W/C&S INDUS-S45W/PHILIPS CCMSSL45W/CROMPTON SMARTSL45W or equivalent cat part of makes as specified in Appendix ‘A’ approved list of makes / manufacturers here-in-after and approved by GE. Note :- (i) Cable for connection of LED light fitting shall be measured and paid under serial item no. 17.00 of BoQ here-in-after .
Supply and fixing energy efficient LED street light fitting of 60 Watt seasonal RTC control with dimmable type, including No. of LED bulbs as per manufacturers instructions for lighting of 60 watt , epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection for cable connection complete all as specified and directed by Engineer in charge. Make HALONIX CAT NO. HLCGRFSL1004/ WIPRO LR0260W/HPL CCMSSL60W/HAVELLS CCMSLS60W/C&S INDUS-S60W/PHILIPS CCMSSL60W/CROMPTON SMARTSL60W or equivalent cat part of makes as specified in Appendix ‘A’ approved list of makes / manufacturers here-in-after and approved by GE. Note :- (i) Cable for connection of LED light fitting shall be measured and paid under serial item no. 17.00 of BoQ here-in-after .
Taking out old broken PCC Pole of any size , embeded with PCC foundation including foundation and Erecting and fixing only Pre-stressed cement concrete pole 9.00 metre long in perfect vertical position, including painting of poles with two coats of radiant paint over a coat of primer with black and white strips 30 cm wide each up to 1.5 mtr height from top of PCC foundation block and numbering of poles including applying one coat of cement base paint on exposed surface of PCC coping and foundation blocks complete all as specified and directed by Engineer-in-charge Note :- (i) PCC work shall be measured and paid for separately under appropriate item of BoQ. (ii) PCC Pole shall be measured and paid separately under serial item no. 12.00 of BoQ here -in- after as supply only. (iii) The T & P / vehicles will be arranged by the contractor for transporting the pole from AGE (E/M) Elect store yard to site of work and the cost deemed to be included in the quoted rates. complete all as directed by Engineer-in-charge.(iv) The rate of excavation , returning filling and removal of earth work is included in this item and nothing shall be paid extra on this account.
Supply only Pre Stressed concrete Pole 9.00 Mtr long ,102mm x 172 mm at top ,102mm x 279 mm at bottom , class 10 complying with requirements of IS-1678-1978 complete all as specified and directed by Engineer-in- Charge.
Taking out old unservicable Steel tubular poles of any size , embeded with PCC foundation including foundation complete all as directed by Engineer -in-Charge. Note :- (i) PCC work shall be measured and paid for separately under appropriate item of BoQ.(iv) The rate of excavation , returning filling and removal of earth work for this item and for serial item No.14.00 & 15.00 of schedule 'A' is included in this item and nothing shall be paid extra on this account.
Material and Labour Steel tubular poles type 410 SP-22 (8.50mtr long) complete with cast iron base plate, finial, taper plug, bolts nuts & screws complete all as specified including internal surface of steel tubular pole through out and external surface up to planting depth shall be painted with bituminous paint and remaining external surface shall be treated with two coats of aluminium paint over a coat of red oxide zinc chromate primer complete and painting upto 1.5 mtr with alternate layer of yellow & black including marking Sr No of the poles all as specified. (Note:- (i)PCC shall be measured and paid separately under respective item of Sch.(ii) The rate of excavation , returning filling and removal of earth work is included in serial item no.13.00 here-in before and nothing shall be paid extra on this account.
Material and Labour Steel tubular Single swan neck pole type 410 SP-31 (9.00mtr long) complete with cast iron base plate, finial, taper plug, bolts nuts & screws complete all as specified including internal surface of steel tubular pole through out and external surface up to planting depth shall be painted with bituminous paint and remaining external surface shall be treated with two coats of aluminium paint over a coat of red oxide zinc chromate primer complete and painting upto 1.5 mtr with alternate layer of yellow & black including marking Sr No of the poles all as specified. Note:- Necessary earthwork and cement concrete work shall be measured and paid seperately in respective items of schedule 'A' BoQ. (Note:- (i)PCC shall be measured and paid separately under respective item of Sch.(ii) The rate of excavation , returning filling and removal of earth work is included in serial item no.13.00 here-in before and nothing shall be paid extra on this account.
Material and Labour for PCC (1:4:8) type D2 using 40mm graded crushed stone aggregate as in foundation of poles etc, filling and mass concrete including necessary form work complete all as specified.
Supply and fixing service wire PVC insulated stranded aluminium conductor, served with inner sheating of PVC tape and overall PVC sheathed of Size 6 Sqmm twin core flat, 1100 volts complete all as specified and directed by Engineer-in charge.
Taking out old unservicable under ground LT XLPE / PVC cable of any size from trenches / wall / roof / road / pipe / pole / DB including taking out of brick layer of cable protection complete all as specified and as directed by Engineer-in-Charge.
Relaying of old serviceable under ground PVC / XLPE LT cable of any grade , any size reterived from serial item No.18.00 here-in- before, laid in trenches / fixed to wall / pole / roof / laid in floor including necessary connections and thimbling complete all as specified and as directed by Engineer-in-charge. (Earth work, brick & sand cushioning shall be measured and paid for separately under appropriate item).
Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 16 Sqmm 2.00 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge.. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 16 Sqmm 4.00 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge.. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for pipe line, cable trenches or for manholes etc not exceeding 10 sqm area on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified.
Removing excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified.
Material and Labour sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified. (Note:- Punned thickness shall be considered for payment purpose)
Supply and laying best quality , locally available well burnt clay brick old size class B laid dry flat for protection over the cable, width equal to the length of cable complete all as specified complete all as specified and as directed by Engineer-in-Charge.
Re-laying old bricks retrieved from srl Item No 18 here-in-before, for cable protection , laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
Cleaning and preparation of old painted surface of street light steel tubular pole 9.00 mtr long and painting with one coat of aluminum paint including brackets and making alternative black and white strips on pole with two coats of glow/luminous synthetic enamal paint (each strip 30 cm height) upto 1.5 mtr height from top of PCC foundation block and numbering of poles complete all as specified and as directed by Engineer-in-Charge.
Cleaning and preparation of old painted surface of LT PCC Pole 9.00 mtr long including painting of poles with two coats of glow/luminous synthetic enamel paint and making altranative black and white strips 30 cm each up to 1.5 mtr height from top of PCC foundation block and numbering of poles complete all as specified and as directed by Engineer-in-Charge.
Material and Labour Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI wire 4mm for pole earthing with GI bolts / nuts / washers, earth lead protected by 15 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm GI light grade pipe for watering and including funnel, wire mesh,RCC cover & frame, PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR Part – I. Note :- PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner.
Opening / disconnecting the electrical connection of defective / burnt out underground LT cable of any size any core from main switch / DB / junction box / LT panel / L T O/H line etc. Taking out the required length of cable from existing loop, cutting the defective portion of cable ,providing required thimbles / connectors at cable end and reconnecting the cable in previous location with existing main switch / DB / Junction box / LT panel / OH line etc all as directed BY Engineer-in-charge. Note:- (i) the cost of required earth work ie excavation,returning filling,relaying of sand / bricks and cost of drawing the required length from protection pipe ,breaking of required brick work / plaster / concrete and redoing the required cement work to match the existing surface is deemed to be included in quoted rates and nothing extra should be paid on this account.(ii) Additional cable/ protection pipe required at site shall be measured and paid seperatly.
Supply and fixing junction box ,size not less than 200mm x 160mm x 98mm, insulated type , made out with Polycarbonate with glass fiber reinforced. Cat Part No. KF5255 Make of Hensel / Siemens / GE Power / Rittal. Note :-1.Manufacturer should submit routine test certificate for CJB/PJB 2.The Polycarbonate Junction Box shall be environment friendly, recyclabe, UV resistant, halogen & silicon free, anti acid & anti corrosive. 3. The Junction Box shall be rated for Degree of ingress Protection IP 66 in accordance with IEC 60529. 4.The gasket material of junction box shall be Polyurethane and the gasket shall be internally embedded. 5.The Junction Box shall be complies with requirements of the standards IEC 60998 - 1, IEC 60988 - 2 - 1, IEC 60670 - 22 & IEC 60670 - 2 - 5. 6. The Junction Box color according to RAL 9011. 7.The manufacturer of Junction Box / Enclosure shall submit a copy of IEC Certificate . For beter safety the Polycarbonate enclosure and shall be fire retardant & self - extinguishing in accordance with IEC 60695 - 2 - 11, DIN VDE 0304 Part - 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 degree Centigrade. The impact strength of Polycarbonate enclosure / boards i.e. the Degree of protection against mechnical load shall be in accordance with EN 50298 - 98 for IK 08 including 4 pole connector/bus bar with MCB SP 'C' curved 2.5 Amp complete all as specified.
Taking down the lanteren carrige assembly along with lanterns after replacement of worn out pully at top section of high mast ,welding putting the fell down wire rope in pully groves in proper alignment for satisfactory operation of winch system by arranging hydraulic crane from civil market having boom suitable for working at 16 mtr height all as directed and carrying out work all as directed by Engineer-in-Cahrge .(Note:-Cost of hiring of hydraulic crane suitable for working at above 16.00 mtr height and T&P used for repair of high mast is included in this item and nothing shall be paid extra on this account. and spares shall be measure and paid seperatly under respective item of Schedule'A' BoQ
Material and Labour for Rewinding of motor 2 HP ,3 phase ,415 volts ,1425 RPM with copper wire of existing size and varnishing , greasing of bearing complete and testing all as directed by Engineer-in-Charge.Note :-(i)make of copper wire for rewinding of motor shall be approved by Engineer-in-charge and binding wire shall be ISI marked.(ii) Labour element of Bearing is included in this item and Bearing shall be measured and paid under serial item no.32 .00 of BoQ here-in-after.(iii) cost of varnishing , binding wire of approprite gauge and greasing to bearing is included in this item and nothing shall be paid extra on this account.
Supply only Bearing 4026 all as directed by Engineer-in-Charge. Make :- SKF / NBC / FAG
Cutting / trimming of tree branches upto 1.50 metre distance on each side and 3.00mtr distance on both sides of LT over head lines including collection and removal from road complete all as directed by Engineer-in-charge. Note :-For measurement and payment purpose each span shall be considered as 40.00 mtr. Span.If the length of span is less than 40.00mtr measurment and payment shall be considered proportionally.
Material and labour for making the hole under road and hard standing for laying and incluidng inserting Galvanised steel light grade pipe of 80 mm dia including all fittings as required at site by mechanical drill system or Auger system and making the surface good as per existing surface completed all as specified and directed by Engineer-in-Charge.Note : The rate of Galvanised steel light grade pipe of 80 mm dia is included in this item and nothing shall be paid extra on this account.
DIAMOND SALES COROPORATION
Sandeep Enterprises
Bidder Name
M/s NIRMAN BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .