Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹9,168.40Qualified Make: Sigma
Model: TPNB-63 C 176 C 176 PHASE 2 MAYAPURI INDUSTRIAL AREA NEW DELHI MAYAPURI INDUSTRIAL AREA WEST DELHI DELHI 110064 | WEST DELHI | DELHI | 110064 | Make: Sigma
Model: TPNB-63 | L1 | Qualified | |
| 2 | L2₹11,520+₹2,351.60 (25.6%)Qualified Make: Orion
Model: ORION 1033 527 B UNCHWA GARHI KUTCHERY RAJAPUR ALLAHABAD ALLAHABAD UTTAR PRADESH 211002 UDYAM UP 03 0003958 | PRAYAGRAJ | UTTAR PRADESH | 211002 | Make: Orion
Model: ORION | L2 | Qualified | |
| 3 | L3₹17,800+₹8,631.60 (94.1%)Qualified Make: Sigma
Model: TPNB-63 GANESH CHANDRA AVENUE GROUND FLOOR KOLKATA WEST BENGAL 700013 INDIA | KOLKATA | WEST BENGAL | 700013 | Make: Sigma
Model: TPNB-63 | L3 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
4 Jun 2018, 3:00 pmClosed
miniature circuit breakers Miniature Circuit Breakers ( 20 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Governing Indian Standard specification IS/IEC 60898-1:2002 Yes - Rated Current (Ampere) 63 A 63a Instantaneous Tripping Range B b Rated Voltage (Volt) 415 VOLT 415volt No of poles/Protected poles(PP) 4 pole with 3PP 4polewith3pp ISI marking Yes - CM/L No: 2207840 - CM/L Validity up to 30-08-2020 - CONSTRUCTIONAL Steel sheet enclosure for MCB of 1.2 mm thickness duly pretreated stove enamelled/powder coated Without - Rated Short circuit capacity (Ampere) 10000 A - CERTIFICATIONS Availability of Type test report from Central yes - 1/2 government/NABL/ILAC accridiated laoratory to prove conformity to the specification for each rating. Test Report number RP-1617-032519 - Date of issue of Test Report by Laboratory 12-10-2016 - Test Report to be furnished to the buyer on demand Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sanjay Kumar Gupta 486890
NEHRU SATABDI CHIKITSHALYA
SINGRAULI 20 15 EMD Required No ePBG Required No
80907
GEM/2018/B/11542
GeM Contract
miniature circuit breakers
GeM Contract
15 days
Madhya Pradesh; Singrauli
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| miniature circuit breakers Miniature Circuit Breakers ( 20 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Governing Indian Standard specification IS/IEC 60898-1:2002 Yes - Rated Current (Ampere) 63 A 63a Instantaneous Tripping Range B b Rated Voltage (Volt) 415 VOLT 415volt No of poles/Protected poles(PP) 4 pole with 3PP 4polewith3pp ISI marking Yes - CM/L No: 2207840 - CM/L Validity up to 30-08-2020 - CONSTRUCTIONAL Steel sheet enclosure for MCB of 1.2 mm thickness duly pretreated stove enamelled/powder coated Without - Rated Short circuit capacity (Ampere) 10000 A - CERTIFICATIONS Availability of Type test report from Central yes - 1/2 government/NABL/ILAC accridiated laoratory to prove conformity to the specification for each rating. Test Report number RP-1617-032519 - Date of issue of Test Report by Laboratory 12-10-2016 - Test Report to be furnished to the buyer on demand Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sanjay Kumar Gupta 486890 | - | - | - |
| NEHRU SATABDI CHIKITSHALYA | - | - | - |
| SINGRAULI 20 15 EMD Required No ePBG Required No | - | - | - |
Exempted
25 Aug 2018
11 May 2018
contract_GEMC-511687799458076.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_80907.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .