Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC R O ZANGSTI LEH LADAKH 194101 | LEH | LEH | LADAKH | 194101 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹21.4 L+₹52,678.05 (2.52%)Rejected-AOC | L2 | Rejected-AOC Not accepted being L2 | |
| 3 | L3₹22.2 L+₹1.3 L (6.08%)Rejected-AOC | L3 | Rejected-AOC Not accepted being L3 | |
| 4 | L4₹23.3 L+₹2.4 L (11.6%)Rejected-AOC R O Y K PURA QAZIGUND ANANTNAG 192221 J K | ANANTNAG | JAMMU AND KASHMIR | 192221 | L4 | Rejected-AOC Not accepted being L4 | |
| 5 | L5₹24.3 L+₹3.4 L (16.4%)Rejected-AOC | L5 | Rejected-AOC Not accepted being L5 |
Tender Value
Refer Docs
EMD Value
₹41,250
Closing Date
20 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PARTAPUR
GE PARTAPUR
PROVN OF HARDSTANDING FOR VEH PARKING AREA AT ADHOC TRANSIT CAMP AT KHALSAR AND SPL REPAIR TO BLDG NO T 55 AT FD REGT AT SOASOMA AND REVENUE WORK AT CG BN AT BASE CAMP UNDER GE PARTAPUR
2021_MES_455870_1
GE/P-41/2021-22
Open Tender
Civil Works
Works
180 days
GE PARTAPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE PARTAPUR
₹41,250
Yes
10 Jan 2022
30 Jun 2021
22 Jul 2021
14 Jul 2021
20 Jul 2021
14 Jul 2021
60 days
Amount
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm thick (below or above ground level) complete all as specified and as directed.
M&L 25mm thick plain cment concrete 1:2:4 type B-0 using 12.50mm graded crushed stone aggregate) as in floor
M&L for 15mm thick screed bed or bedding layer of mortar for laying floor finishes in CM 1:6 complete all as specified and directed.
S&F non skid ceramic tile 7 to 8mm thick (square / rectangular) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement match.
Dismantling wall and ceiling board (fibre, pulp, insulation etc) or insulation board/slabs/ blanket any thickness including cover filllets.
M&L pre-laminated particle board 9mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination as in wall, fixed with nails to timber frame work
M&L pre-laminated particle board 9mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination as in ceiling, fixed with nails to timber frame work
Dismantling timber framed in fillets, rails, posts rafters, purlines, etc under 40 Sq cm in section.
M&L second class softwood plain filllets, rectangular in section, clean swan, secured with nails exc 13 and n.exc 25 Sqcm.
M&L second class softwood plain fillets, rectangular in section, clean swan, secured with nails exc 3 and n.exc 6 Sqcm.
Dismantling of plain of corrugated steel sheeting any gauge, thickness including Nainital or similar pattern roof covering.
S&F Galvanised MS sheeting of 0.63mm thick corrugated ISI Marked and made of shakti with two cougation side laps and fixed with J hooks two framed work with PVC and steel washers as in roof & wall with Zinc coating of 275.
S&F plain, galvanised MS sheeting of 0.63mm thick in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275
Re fixing of Galvanised MS sheeting of 0.63mm thick corrugated ISI Marked and made of shakti with two cougation side laps and fixed with J hooks two framed work with PVC and steel washers as in roof & wall as specified with Zinc coating of 275.
Takingdown chowkats or frames with shutters (without taking offf shutters from the frames) not exc. 1.5 sqm each.
S&F steel windows with side hung shutters including projecting type hinges with steel handles and steel peg stay complete all without glazing bars devetailed or welded.
S&F for sheet 5.0mm thick, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane.
M&L for preparation of newly steel surface of any description not other wise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide.
M&L for preparation of old painted surface of any description not other wise described, over 10cm width or girth and applying two coats of synthetic enamel paint.
M&L for 20mm thick screed bed or bedding layer of mortar for laying floor finishes in CM 1:6 complete all as specified and directed.
M&L 50mm thick plain cment concrete 1:4:8 type B-2 using 40mm graded crushed stone aggregate) as in floor.
M&L for chequered cement concrete tiles 20cmx20cmx25mm thick, set and jointed and pointed in neat cement slurry in floors with grey cement and no pigment.
M&L for PCC 1:3:6 type C2 75mm thick using 40mm graded stone aggregate as in plinth protection.
Surface excavation n exc 30 cm deep and averaging 15 cm deep and gatting out in hard dense soil.Complete all as specified and directed by Engr-in-charge.
Add for item No 1 for every 3 cm or part thereof below 15 cm average depth and getting out inhard/dense soil.
Removing of excavated material n exc 50m and depositing where directed at a level n exc 1.5 m above the starting point.
Rolling and consolidating formation surfaces in cutting power roller exc 8 tonne & nexc 12 tonne complete
M&L for 100mm thick hard core of gauge n exc 63mm, deposited spread and levelled in layers n. Exc 15 cm thick, watered and rammed to a true surface broken stone or boulders
M&L for 150 mm thick PCC 1:4:8 type D2 (40mm graded aggregate as in sub base cmplete
M & L 150mm thick PQC as in pavement of flexural strength 40 Kg/Sqm using 400 Kg of cement
Forming contraction joints(dummy joints) 65 mm deep x 10mm thick wide and filled with sealing compound grade 'A'
Forming construction joints 30mm deep x 10mm thick wide and filled with sealing compound grade 'A'
Finishing surfaces of concrete roads, hardstanding , by brooming
M&L 25mm thick plain cement concrete 1:2:4 type B-0(using 12.5mm graded crushed stone agg) as in floor finishing cement concrete surface even and smooth with out using extra cement.
M&L for 15mm thick screed bed or bedding layer of mortar for laying floor finishes in CM 1:4 complete all as specified and directed.
M&L for chequered cement concrete tiles 20cmx20cmx25mm thick, set and jointed and pointed in neat cement slurry in floors with grey cement and pigment complete all as specified and directed.
Taking down carefully damaged copper/aluminum point wiring (light/fan/socket or power) complete including fixture and fittings such as switches, ceiling roses, cassing & capping, pendants, sockets, light fitting etc and making good disturbed surfaces of wall/roof complete all as specified and directed.
Taking down of MCB DB/TPN 4way/12way including mcb sp and spn and making good of wall complete all as specified and directed.
M&L Point wiring with 1.5 Sqmm (nominal area) copper conductor FRLS cable (multi-stranded) PVC insulated and unsheathed electric cable 1100 volts drawn through PVC casing and caping of suitable size (as per conductor run) with all fittings and accessories and including PVC insulated unsheathed electric cable 1100 volts 1.5 Sqmm (multi-stranded) copper conductor single core (green colour) as continuous earth wire connected to common earth dolly including 50mm deep box made out of 2nd class hard wood board of suitable size and shape and other boxes for mounting light fittings etc covered with 3mm thick plastic laminated Hylum ISI marked for following complete all as specified and directed by Engr-in-Charge. Note:- Screw used for fixing TW baords, casing and caping ceiling rose, square blocks etc should be nickel cadmium screws.
(a) One light point controlled by one 5 Amps one way switch
(b) One 3 pin socket outlet 5 Amps on independent board
(c) One 3 pin socket outlet 5 Amps on same board
M&L point wiring for power point with 4.0 sqmm (nominal area) copper conductor FRLS cable ( multi-stranded) PVC insulated and unsheathed cable conductor 1100 Volts drawn through PVC casing capping of suitable size(as per conductor run) with all fittings and accessories and including PVC insulated unsheathed electric cable 1100 volts 2.5 Sqmm (multi-stranded) copper conductor single core (green colour) as continuous earth wire connected to common earth dolly including 50mm deep box made out of 2nd class hard wood board of suitable size and shape and other boxes for mounting light fittings etc covered with 3mm thick plastic laminated Hylum ISI marked for following complete all as specified and directed by Engr-in-Charge. Note:- Screw used for fixing TW baords, casing and caping ceiling rose, square blocks etc should be nickel cadmium screws.
S & F Switch piano flush button single pole one way 5 Amps, 240 Volts complete all as specfied and directed by Engr-in-Charge.
S&F switch socket combination 3 pin, 5 Amps, 2 in 1 flush type (multipurpose) suitable for 2 pin / 3 pin plug complete all as specified and directed by Engir-in-Chage.
S&F switch socket combination 2 in 1, 3 pin, 5/15 Amps, flush type (multipurpose). Complete all as specified and directed by Engr-in-Charge.
S & F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engr-in-Charge.
Supply and fixing Rechargeable LED inverter Bulb energy saver 9 W ,B22 (220-240 V) 50 hz, 6500k, fast charging 2200 mAH battery inbuild ,white color all as specified and as directed. Make- Phillips stellar bright or equivalent.
&F surface and wall mounted LED batten with polycarbonate housing and integrated electronic driver tube light fitting 22W, 4 ft long, 220 Volts , and connecting to ceiling rose with three core twisted flexible copper cable of suitable size complete all as specified and directed.
S&F Ceiling rose surface backelite ISI marked with 3 terminal including connecting and testing complete all as specified and directed.
S&F MCB DB sheet enclosure,Double door type, single pole and neutral 240V with 200 Amp rated bus bar suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete confirming to IP 42/43 without MCB and with enclosure blank plates for unused way suitable for 12 way complete all as specified and directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning all as specified and directed.
Supply and fixing MCB SPN 240V, 10KA 'C' curve 63 Amp current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground not less than 2.25m deep below normal ground level (with the top edge of the plate not less than 1.50 m below the normal ground level) connected to GI earth wire 4 mm by means of GI bolts, nuts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point with and including necessary excavation and earth work in any strata PCC pit 1:3:6 type C-1, 20mm bore medium grade GI pipe for watering 15mm bore light grade pipe for GI wire protection and funnel including 40mm thick RCC slab cover and testing on completion all as specified and as directed.
Supply & Fixing LED light fitting 1X10W bulkhead luminaires including LED light and driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified and directed.
M & L for GI Pipe (medium grade,ISI Marked) 32 mm dia ,1.5 mtr long ,bend to shape for street light fitting bracket ,with 2x pairs of MS clamps of suitable length of size 40x5 mm of MS flat iron with nuts bolts and washer and taking out old one including connection with street light complete all as directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete making all necessary connection with suitable capacity of 3 core circular cable complete all as specified and directed.
Taking up the existing cables from trenches of any size all as specified and directed.
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 16 sqmm 2 core complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cable, fixing of stay etc 10 Sqm on plan and n exc 1.5 in depth and getting out in hard/dence soil complete all as specified and directed by Engineer-in-Charge.
Returing, filling in incl spreading, levelling watering and well ramming in layers n.exc 25cm width, Complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above starting point Completed all as specified and diercted by Engineer-in-Charge.
Sand cushioning for under ground cable 8 cm before laying the cable and 15 cm after laying and streching the cable complete all as specified and directed by Engineer-in-Charge.
M&L Un-reinforced precast factory made concreate cable covers, class LV type-I, with flat size 250x150x40 mm Complete all as specified and directed.
Supply and laying GI pipe medium grade 40 mm fixed on walls/ poles/laid in trenches as cable protection all as directed and specified.
H R CONSTRUCTION
M/S SONAM RIGZIN
M/S BHAT ENGINEERS
M/S LIBE & CO
BETONG BUILDERS
Rampal Singh Contractor
M/S MOHD KARIM
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .