Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹81.2 LAccepted-AOC 04 L BLOCK MARKET SECTOR 11 NOIDA 201301 UP GAUTAM BUDHA NAGAR | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹81.7 L+₹50,190 (0.62%)Rejected-Finance 1ST 2ND FLOOR PLOT NO 13 C 13 3 RAMA ROAD SIDE INDUSTRIAL AREA NAJAFGARH ROAD DELHI 110015 INDIA | WEST | DELHI | 110015 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹88.4 L+₹7.2 L (8.91%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹92.4 L+₹11.2 L (13.8%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹96.9 L+₹15.7 L (19.3%)Rejected-Finance D 1 A 72 UPPER GROUND FLOOR JANAK PURI JAI ROAD NEW DELHI DELHI 110058 | WEST DELHI | DELHI | 110058 | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹97 L
EMD Value
₹1.7 L
Closing Date
9 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CE CG GOA
HQ Chief Engineer CG Chicolna Bogmalo Post, Goa 403 806
PROVISION OF HIGH MAST LIGHTS, VOLTAGE STABILIZER, RETROFITTING OF EMISSION CONTROL DEVICES (RECD) ETC UNDER AGE (I) CG NOIDA.
2023_MES_593354_1
83022/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
AGE (I) COAST GUARD, NOIDA
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
AGE (I) COAST GUARD, NOIDA
₹1.7 L
Yes
23 Jun 2023
4 May 2023
12 Jun 2023
4 May 2023
9 Jun 2023
26 May 2023
Amount
Excavation in trenches in any type of soil n, exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables, foundation filling of poles or stays complte all as specified and directed.
Returnig filling, in including spreading, levelling, watering and well ramming in layers not exec 25 cm each complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M & L for good quality dry sand cushinoning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule Pt-I (2009) thickness shall be measured and paid complete all as specified and directed.
Supply and Laying sub class 'B' bricks of old size (230 x 115 x 75 mm) or of size locally available, laid along alingment of cable as protection to cable in trenches complete all as specified and directed.
Design, supply, installation, testing & commissioning of - 30 Mtr High mast system with its accessoriees. The mast shall be polygonal, continuously tapering, hot dip galvanized with suitable fixed type head frame for mounting 20 Nos of flood light fixtures. Polygonal high masts shall have following features :- (a) Masts shall be structurally designed in accordance with PLG 7– latest edition considering the gust wind speed as per IS 875 prevailing in the region. (b) The steel used in the construction of the masts shall comply with IS 2062 grade E350 / BS EN 10025 or Equivalent having minimum yield strength of 350 N/Sq. mm. (c) The High mast shall be of continuously tapered, polygonal cross section, presenting a good and pleasing appearance and shall be based on proven In-Tension design conforming to the standards referred to above to give an assured performance and reliable service. (d) For the environmental protection of the mast, the entire fabricated mast shall be hot dip galvanized internally and externally having a uniform average coating of 85 microns for plates more than 6 mm and 70 microns for plates 6 mm and less thickness. The Zinc shall have minimum 99.995% purity confirming to IS 209.
(e) The length of any individual segment shall be such that it can be easily transported and erected. All similar parts shall be made strictly inter-changeable. Mast segments, as far as possible, shall be fabricated in single piece. In case of restriction due to the size of hot dip galvanizing bath, pole segments having outer diameter more than 1mtr may be fabricated in two halves and seamlessly welded after galvanizing. After seamless welding of both halves, surface of the welded portion shall be cleansed and prepared. Two welded portions shall be galvanized by suitably dipping in hot zinc bath or by metallizing using molten zinc technique. For metallizing, the process as per ANSI/AWS WCZ/D19.0-72 or other National/International standard/Guidelines shall be followed. The thickness of zinc coating by metallizing shall not be less than the minimum specified for hot dip galvanizing. (f) The masts sections shall be joined at site by slip-stress-fit method and minimum overlap distance shall be 1.5 times the diameter at penetration. (g) The mast structure shall be suitable to sustain an assumed maximum reaction arising from a wind speed as per IS 875 Part-3 2015 (three second gust) and shall be measured at a height of 10 metres above ground level. (h) All welding shall be undertaken and performed as per WPS/PQR in strict accordance with BS 5135.or AWSD1.1. (j) The head frame cross arm brackets shall be of suitable steel construction. (k) The high mast manufacturer should have in-house civil, structural and product design facilities and the shaft is to be manufactured from ISO 9001, ISO 14001 and ISO 45001 certified factory taking care of all aspects of design, quality, environment and safety.
Platform and Head frame of the Mast. (a) The mast shall have a fixed head frame at the top of the mast. The head frame shall be with a 15-degree tilt for aiming the luminaries to the proper points. The tilt also helps the maintenance man, while working on the top. • The head frame shall have a shaft section like other mast sections in the middle and cross arms to mount required number of luminaries. Suitable provision shall be provided in the cross arms for fixing of luminaries and support the cables. Suitable opening on each side of the shaft and window in back side is to be provided to take and facilitate passing the cables to the luminaries through cross arms. (b) An inspection opening shall be provided on the head frame shaft. Support shall be welded on the head frame shaft to suspend the luminaire cables from the top. Cables are to be bunched and supported with stainless steel suspension ropes of suitable length. No other equipment shall be mounted in the path of the cables inside the mast as it will affect the safety of electrical cables for the luminaries. (c) Lightning finial shall be provided on the mast top of the shaft. Provision to be made on the top cross arm to mount the aviation obstruction light accessible from the ladder.
(d) A suitable platform shall be provided on top of the mast. The platform shall be such that the maintenance man can safely stand on the platform and work. The platform shall have protective railing on three sides for safety purposes. There shall be ladders from the platform to the top of the head frame for access to the luminaries mounted on the cross arms. Safety rope is to be provided to hook the PPE (Full body harness). (e) The platform shall have suitable docking facility for the man rider unit to enable the maintenance man to enter the platform from the man rider unit. (f) The connection between the head frame and mast top shaft is by a flanged joint and bolted together. No slip joints in this position shall be used. (g) Access to the floodlights on the head frame shall be by a minimum number of four vertical ladders of the full head frame height.
NOTE :- The cost of High mast includes the following :- (a) Erection and commissioning of the high mast with the help of suitable equipment. (b) Provn of Aviation Obstruction Light LED type. (c) Provn of lightening arrestor spike. (d) The contractor shall submit OEM technical specification of High Mast for approval of Accepting Officer before placing order. (e) The material & labour for LED flood light fittings & control panel required will be measured and paid separately under relevant schedule items. Makes: Bajaj/ Valmont/ Aster
M & L for provision of foundation with M-25Grade concrete for High masts considering the safe soil bearing capacity at site as (SBC of the site is 100 KN/Sqm at 1.50 mtr depth and 230 KN/Sqm at 5.00 mtr depth) at 4 mtr depth with all material and labour all as per Manufacturer's design of foundation drawing as approved by accepting officer. Note :- (i) Rate of earth work in any strata i.e excavation, return, filling, removal, RCC foundation with foundation bolts manufactured from special steel with nuts, washers, anchor plate and template deemed to be included in item rate. (ii) The contractor has to submit the design and drawing of foundation from OEM.
Supply, install, testing & commissioning of Manrider System for High Mast with following :- (a) Access to the mast head frame flat form shall be by a detachable and mobile man-rider unit with a minimum safe load carrying capacity of 300 Kg. The unit shall be of galvanized steel construction with twin cage arrangement along with spring loaded wheels encasing the mast shaft for proper balancing and to avoid swaying of cage while climbing. Suitably rated motor and double drum winch shall be installed in the base of mast. The hoisting arrangement shall comprise of AISI 316 grade stainless steel wire ropes of 8 mm diameter and cast aluminum pulley with gunmetal bush bearing. The unit will have a climb rate not in excess of 9 meters per minute and shall contain required safety features. Man rider will incorporate secondary fall arrester system for protection against failure of the main rope. (b) Man-rider should be detachable type with wheels for moving from one location to other and common for all the masts of the stadium. (c) A portable control box fabricated out of 14swg CRCA sheet housing and finished with powder coating of shade 631 as per IS:5 comprising 32A TPN MCB incomer, contactors suitable for the rating of motor for raising and lowering operation of the man rider. Push button to raise and lower the man rider is to be provided with 5 m cable to operate from a distance. There shall be 32 Amp TPN plug wired to the control box to take power to control box. A Three pin socket is to be provided on control box to hook the motor plug complete all as specified and directed
Supply ,install, testing and commissioning of LED flood light 500 Watt , with luminous flux 60,000 lm and luminaire efficacy 120 lm/w and corrlated color Temperature 5665K + 355K Operating Temp Range -110 degree Celcious to + 50 degree celcious , operating on 120 to 277 V AC ,50 Hz frequancy ,Power factor > 0.95 ,THD value <10% ,Inbuilt Surge protection 4kV ,External Surge Protection 10 kV, ingress protedtion IP 66 and Mechanical Impact protection IK08,having approx weight 13 Kg , having Graphite grey powder coated pressure for better heat sink efficient dissipatation of heat ,Heat resistance toughned glass with silicon gasket and individual LED lenses, complete including MS clams of suitable size for fixing on High Mast GI frame/pole complete all as specified and directed. Make:- Bajaj/Philips/Wipro /Cromption
Supply ,install, testing and commissioning of single dome LED Aviation Obstruction Light alongwith its connected accessories and connection of cable from MCB to AOL light. complete all as specified and directed. Make :- BAJAJ /BINAY/ALTOS or equivalent. Two numbers per mast.
Supply ,install ,testing & Commissioning LT panel made out of 3mm thick CRCA sheet, double door type with slopy canopy suitable for outdoor installation with degree of protection IP-54, with angle iron frame made of 40x40x6mm at vertical comers & Medium channel at base of panel board floor mounted, dust and vermine proof, suitable for voltage 415 V, 3 phase, 4 wire weather proof, with separate hinge door for each compartment with locking arrangement, with back door common openable (Screwed), grouted in PCC 1:2:4 complete incl painting the steel surfaces with two coats of zinc chromate primer & two coats of epxoy paint, type tested, with TPN copper bus bas chamber 250 Amp capacity and connections with spring loaded fix connect terminals with temperature resistance of 40 degree celcius to 120 degree celcius with cable entry suitable size of glands terminals & thimbles all as specified and prewired with suitable size of PVC insulated copper conductor cable duly mounted on angle iron frame fixed on PCC blocks fixed with grouted bolts nuts and washers complete including supply fixing and making provision of the followings :-
Supply, laying and testing of LT UG cable, XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 4 core complete all as specified and directed. Note :- Earth work (Excavation, Returnig & refilling and removal), sand cushioning, cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Sch 'A'.
Supplying and fixing and commissioning service cable 4 sqmm, three core multistranded 1100 volts grade heavy duty cable PVC insulated copper conductor complete all as specified and directed.
Cutting the tarmac/hard standing and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6 type C-1 matching with the surroundings complete all as specified and as directed.
Material and labour for earthing with steel earth plate (GI) electrode of size 600x600x6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as eathing lead by means of nuts, bolts, and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate. GI medium grade pipe 40mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4 kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of carcoal dust and salt layers all around the earth plate, excavation, earth work in any type of soil, removal of excavated soil and returing filling in all as required at site complete all as specified in plate No 3 of SSR Pt-I and all as specified or indicated including testing on completion. Note :- Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 Mtr long for connecting to test point etc. All as requied at site for complete earthing.
Supply & fixing of 32 X 6mm GI Strip from earth electrode including connection with GI nut, bolt, spring washer, excation, refilling etc as require all as specified and directed
Supply and lay in trenches/on roof/on road/on wall steel water tubing galvanised "Medium class", with necessary fittings 40mm dia for cable protection. Complete all as specified and directed.
Taking down u/s BER Voltage stabilizer capacity 250/400 KVA from existing position after safely disconnecting from cables and deposited to E/M store yard for safe custody and accountable all as directed.
Supply, install, testing and commissioning of Servo controlled voltage stabilizer ( Confirming to BIS 9815: (Part 1) (Reaffirmed 2019) 250 KVA ,Three phase,50 Hz, Naturally Oil cooled , indoor ,unbalanced type, copper wound, metallic body duly powder coated with lifting Hooks four nos ,digital display type, relay free smooth and silent operation with 1st filling of Transformer oil up to level ( minimum 650 ltr BIS certified ) having following specification:- (a) Input voltage 340V-480V (b) Output voltage stabilized at 415V +- 1% (c ) Rated frequency 50 Hz, (d) No distortion in wave form (e) Response time not to exceed 20 mile second ( f) sensitivity (+/-)1% (g) Rate of correction 8 Volt/second for single phase and 13 V/seconds for phase to phase, ( h) Efficiency more than 95%,Type of load : three phase , unbalanced type, (j) Digital display with multi-functional meter Protections:- 1 Over load/Short Circuit protections on input side by MCCB 400 Amp 3 pole 36 K (thermal magnetic release adjustable) 2 High/Low voltage cut off 3 By pass arrangement in case of emergency by on load changeover switch 400 amp 4 pole 4 Single phase sequence change protection Capacity:- 250 KVA
Supply, install, testing and commissioning of Servo controlled voltage stabilizer ( Confirming to BIS 9815: (Part 1) (Reaffirmed 2019) 400 KVA ,Three phase,50 Hz, Naturally Oil cooled , indoor ,unbalanced type, copper wound, metallic body duly powder coated with lifting Hooks four nos ,digital display type, relay free smooth and silent operation with 1st filling of Transformer oil up to level ( minimum 900 ltr BIS certified ) having following specification:- (a) Input voltage 340V-480V (b) Output voltage stabilized at 415V +- 1% (c ) Rated frequency 50 Hz, (d) No distortion in wave form (e) Response time not to exceed 20 mile second ( f) sensitivity (+/-)1% (g) Rate of correction 8 Volt/second for single phase and 13 V/seconds for phase to phase, ( h) Efficiency more than 95%,Type of load : three phase , unbalanced type, (j) Digital display with multi-functional meter Protections:- 1 Over load/Short Circuit protections on input side by MCCB 630 Amp 3 pole 36 K (thermal magnetic release adjustable) 2 High/Low voltage cut off 3 By pass arrangement in case of emergency by on load changeover switch 630 amp 4 pole 4 Single phase sequence change protection Capacity:- 400 KVA NOTE for item No 19 & 20 above (i) The contractor shall submit OEM technical specification for servo voltage stabilizer for approval of Accepting Officer before placing order. (ii) Voltage stabilizer shall be tested in presence of Engr-in-Charge at factory premises for Acceptance tests in accordance with Para 11.2 of BIS 9815 (Part-1) Reaffirmed 2004)
S & F Earth continuity conductor or main earthing lead/strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size 32 x 6mm dia galvanised iron or steel wire complete all as specified & directed.
Supply and fix / Retro fitting of Emmision Control Device Confirming to CPCB,new Delhi issued on 01/02/2022 suitbale for 200 KVA on DG set to bring the emission limits as per central pollution control board (CPCB) latest regulation / norms (NO x+HC < 4.0, CO < 3.5 ,PM < 0.2 & smoke limit < 0.7 ) Retrofitting involves the addition of an emission control device to remove emissions from the engine exhaust for reducing emissions,eliminating up to 70-90 percent of pollutants insome cases with CPCB Type approved all as specified and directed.
Supply and fix / Retro fitting of Emmision Control Device Confirming to CPCB,new Delhi issued on 01/02/2022 suitbale for 125 KVA on DG set to bring the emission limits as per central pollution control board (CPCB) latest regulation / norms (NO x+HC < 4.0, CO < 3.5 ,PM < 0.2 & smoke limit < 0.7 ) Retrofitting involves the addition of an emission control device to remove emissions from the engine exhaust for reducing emissions,eliminating up to 70-90 percent of pollutants insome cases with CPCB Type approved all as specified and directed.
Supply and fix / Retro fitting of Emmision Control Device Confirming to CPCB,new Delhi issued on 01/02/2022 suitbale for 62.5 KVA on DG set to bring the emission limits as per central pollution control board (CPCB) latest regulation / norms (NO x+HC < 4.7, CO < 3.5 ,PM < 0.3 & smoke limit < 0.7 ) Retrofitting involves the addition of an emission control device to remove emissions from the engine exhaust for reducing emissions,eliminating up to 70-90 percent of pollutants insome cases with CPCB Type approved all as specified and directed. Make:- for Sr No Item No 23 To 25 M/s Chakr Shield Innovation Pvt Ltd, M/s Pi Green Innovation Pvt Ltd, M/s Pecma Air System Pvt Ltd, M/s Nevorbis Clean Air Solution.
Supply and fixing of sheet metal enclosures Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps "B" Curve ,240 V complete all as specified and directed.
Supply and fixing of Sub main wiring for PVC insulated single core stranded copper cable FRLS of size 2 x 1.5 sq. mm and 1x1.5 sq. mm earth wire for earthing and drawing in PVC consealed conduit and make good distribured area same as existing with colour complete all as specified and directed.
Vardhman Airport Solutions Pvt Ltd
national engineering
Commercial Traders
Choice india
M/s KUMAR BUILDERS
Aggarwal brothers and company
K M SUBHANAIAH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .