Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance NEAR BIDAJI MANDIR BASSI JAIPUR RAJASTHAN 303301 | JAIPUR | RAJASTHAN | 303301 | Admitted-Finance |
| 3 | Admitted-Finance HOSHANGABAD M P | HOSHANGABAD | MADHYA PRADESH | Admitted-Finance |
| 4 | Admitted-Finance F BLOCK JUGGHI NO 82 BUDH NAGAR INDERPURI INDERPURI CENTRAL DELHI DELHI 110012 | WEST DELHI | DELHI | 110012 | Admitted-Finance |
| 5 | Rejected-Technical | Rejected-Technical See in technical evaluation report |
Tender Value
Refer Docs
EMD Value
₹9,960
Closing Date
10 Sept 2020, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGM E and M
FCI Regional Office Jaipur
S/I/T/C of 15 KVAR Automatic Power Factor Conroller Panels at FSD Newai Shivpura Kota Nagaur Kishangarh
2020_FCI_580192_1
ROJ/ELEC/MCW/APFC/01/2020-21
Open Tender
Electrical Works
Works
90 days
FSD Newai FSD Shivpura Kota Nagaur and Kishangarh
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
FCI Regional Office Jaipur
₹9,960
20 Oct 2020
29 Aug 2020
11 Sept 2020
29 Aug 2020
10 Sept 2020
29 Aug 2020
90 days
Amount
Supplying, Installation, Testing and Commissioning of sleek type cubical panel fabricated out 18 SWG sheet steel and suitable frame work having independent compartments for MCCB's/MCB's/Capacitors etc. The panel shall be wall/floor mounted. It should be degreasing, anti-rust treated and finished with powder coated paint. The panel shall have ventilator slots covered with wire mesh from inside. The panel door shall have neoprene gasket. The design of the panel shall be such as to offer maximum safety and ease of maintenance. The bus bars shall be of tinned copper and supported on non-inflammable epoxy cast iron resin insulators. The terminators of cable/wire as per require copper wire with lugs for interconnection and shall be from top or bottom as per site requirement. Engraved name plates shall be provided for each feeder cubical panel shall consist of following switch gears including copper leads between bus bars and switchgears with proper lugs arrangement. ( present capacitor stages are 5 but panels should be made for housing 8 stage capacitor bank and contractors/TP MCBs) One no. of 100 amp, 10KA, 3 pole (TP) MCCB as main incomer of L&T/Schneider/ABB make or equivalent. 1 set of Copper/Al bus bar (4 nos.) of size 25 mm x 3 mm/50x20 Al of suitable length on porcelain insulators compete with incoming and outgoing connections, earthing etc. 1 No. of Digital Voltage, ampere meter along with the 100/5CT . 15 KVAR capacitor bank of 5 stages of EPCOS/ABB/L&T / GE/ Neptune/Schneider make or equivalent as per I.S. 2834 heavy duty metalised polypropylene type. a) 1 KVAR - 1 b) 2 KVAR - 2 c) 5 KVAR -2 d) 1 No. fixed capacitor of suitable capacity to connect LT side of Transformer for magnetizing current compensation. The capacitor should be connected with suitable capacity TP MCB including wiring if require for no load setting. Each capacitor shall have following 3 pole 440 volts TP MCB's of L&T / Schneider/ABB or equivalent make of D series (suitable for capacitor switching) TP MCB 10 A- 5 Nos. LED type indicating lamps 8 Nos. Automatic power factor controller - integral type microprocessor based intelligent relay (for 8 stage capacitor bank) with LCD display with three CT controller along with 03 Nos. of CT's of required ratio sensitivity of 50 mA of EPCOS/L&T/Neptune/BCH/L&T make or equivalent. Capacitor switching Heavy duty contactor 12.5 KVAR capacitor as per IS 13947 of L&T/ABB/GE/Siemens/Schneider make or equivalent. for each capacitor installed - 5 nos. All control wiring of required rating minimum 1.00 sqmm flexible copper wires including lugs and also wiring from panel to individual capacitors.Power wiring will be minimum 2.5 sqmm. Ventilation fan with tublar type on/off toggle switch/single pole mcb switch 6 A. 6 pair 2.5 sq mm copper cable for CT to relay connection as per require Supplying and laying 3½ x 35 sqmm aluminum conductor XLPE Insulated armored cable of 1.1 KV grade with 1 nos. 8 SWG GI earth wire/10 sqmm copper green cable on wall/underground etc. for APFC panel connection make of cable should be NICCO, ICC,BCH, GLOSTER SKYLINE, RALLION, Polycab and KALINGA or equivalent. • Quoted Rates must be considered inclusive of GST and all other taxes.
Ms SINGADIA ENTERPRISES
pawan trading co.
B. L ELECTRICALS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .