Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER FOR THE WORK | |
| 2 | L2₹16.2 L+₹70,272.82 (4.53%)Rejected-AOC 84 A VIJAY NAGAR COLONY LALGHATI PO NAYAPURA BHOPAL 462032 | 462032 | L2 | Rejected-AOC OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹16.4 L+₹89,175.25 (5.75%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN THE LOWEST BIDDER | |
| 4 | L4₹18.0 L+₹2.5 L (15.9%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN THE LOWEST BIDDER | |
| 5 | L5₹18.0 L+₹2.5 L (16.0%)Rejected-AOC | L5 | Rejected-AOC OTHER THAN THE LOWEST BIDDER |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
27 Jul 2020, 6:00 pmClosed
CWE BHOPAL
HQ CWE BHOPAL, SI LINES, BHOPAL, PIN-462001
PROVN OF 125 KVA DG SET ( SILENT TYPE ) WITH ALLIED WORKS AT 21 CORPS DENTAL UNIT, SI LINES BHOPAL. AND PROVN OF 15 KVA DG SET ALONG WITH DG PLINTH, SHED, ELECTRIC PANEL AND ENTRANCE GATE FOR NFS NODE AT BAIRAGARH BHOPAL
2020_MES_356754_1
83542
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BHOPAL
AS PER NIT CONDITIONS
4 documents required · 4 mandatory
₹500
GE BHOPAL
₹39,000
Yes
26 Aug 2020
1 Jul 2020
3 Aug 2020
1 Jul 2020
27 Jul 2020
15 Jul 2020
Amount
M&L for point wiring with 1.5 Sqmm mulit stranded copper conductor 1100 V grade pvc insulated un-sheathed cable drawn through in conceled conduit and conduit accessories, PVC conduit not less than 20 mm dia with one continuous 1.5 Sqmm PVC cable green in colour for earth and sunk in mild steel 18 gauge steel terminal box duly painted with one coat of aluminum paint inside and anti corrosive paint outside with hylam brand or equivalent laminated white bakelite sheet 2.8 mm thick complete or housing of switch socket all as specified and directed for the following
One light / call bell point controlled by one switch.
S&F switch piano type flush button type single pole one way 5 Amps ISI marked
Excavation in trenches not exc.1.5 m wide and not exceeding 1.5 m in depth and getting out in any type of soil for foundation / laying of cable complete all as specified by Engr-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified by Engr-in-charge.
Removing excavated surplus soils meterial not exc. 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified by Engr-in-charge.
M&L for sand filling in-trenches with clean dry sand unwashed including gently prunning around cables complete all as specified. Note: prunned thickness only measured for payment.
Supply and laying reinforced precast concrete cable cover class LV ,type 1, flat, size 250 mm x 150 mm x 40 mm all as specified and directed by Engr-in -Charge
M&L for 80 mm dia GI tubes 'medium grade' for cable protection (sealing both ends for cable pipe) complete all as specified and as directed by Engineer in charge. Make: Tata / Jindal / Zenith / Prakash.
Supply, installation, testing and commissioning of silent Diesel engine generating set with accoustic enclosure as per CPCB norms 415 volts 125 KVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator with AMF panel of suitable rating, Control Cables ,Cable Lugs, Steel Cable glend, panel stand, including accoustic enclosure suitable for ambient condition and ISO 3046/BS 5514 conforming to condition of Bhopal including TESTING of DG Set Make: Cummins Gen Set Model No C 125 D5 P or equivalent in Kirloskar / Greaves.
(a) The capacity of Generator set shall be net after all due de-rating factors as per relevent IS design and site condition. (b) Rate quoted shall be deemed to be inclusive of cable and terminations from Generator to the AMF Panel, with necessary fixing arrangements all as specified and directed. (c) The quoted rate shall be deemed to be inclusive of first fill of oil ,coolant and final successful acceptance test. (d) Alternator : Standard design alternator rated at 125 KVA net output a site after considering de-rating as pe site conditions at 0.8 (lag) power factor AC, 3 Phase-4 wire 415 volts 50 Khz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, The alternator shall be conforming to IS/IEC 60034-1 . The alternator will be suitable for tropical climate and shall generally conform to IS/IEC 6034-1. Make : Stamford Cat No UC27 or equivalent in Kirloskar/Crompton Greaves.
(e) Diesel Engine : Adequate capacity of Disesel engine as accepted by the accepting officer basing on manufacturers technical details liquid cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant with an overload capacity of 10% for half an hour in 12 hours continous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under :- (i) Fly wheel with housing (ii) cooling system : Moulded radiator with fan & belts. (iii) Cooling water pump : centrifugal type belt driven (iv) Exhaust system : Exhaust system complete with exhaust piping of suitable dia with MS pipe light grade upto & outside and 1 meter away suitable dia with MS pipe light grade upto & outside and 1 meter away from the enclosure covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for sale exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charge type Exhaust manifold Silencer : Residual type Make of Diesel Engine: Cummins Model No 6BTAA5.9-G13 or equivalent in Kirloskar/Ashok Leyland.
(v) Fuel system : Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1 % speed / frequency regulations, fuel filters, fuel hoses. (vi) Lub oil system :- (a) Lubricating oil filter (b) Lubricating oil pump (vii) Air Intake system :- (a) Air cleaner dry type (b) Air cleaner dry type (viii) Governor :Mechanical Governor (ix) Staring system : Electric self starter with maintenance free battery including battery charging alternator. (x) Batteries : Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and starter gear ring start and stop push button, Ignition key switch Handing and operation : Sailent features of accessories shall be as under : (aa) Radiator with Blower fan (ab) Corrosion inhibitor coolant (ac) Paper element filters for fuel, lub oil and by pass (ad) Mechanical governor controlled direct fuel ijection system (ae) Fly wheel housing and fly wheel
(xi) Generator Monitoring Panel : Comprising of all standard item as mentioned under this schedule / as per standard practice ignition key switch and start / stop arrangement, indications for Engine parameters hour run meter, RPM meter, Engine oil pressure indicator, water / coolant temparature indicator, battery volt display. (xii) Safety controls : Engine low lube oil pressure high water temparature and over speeding of engine (xiii) Coupling arrangement : Flexible coupling, fly wheel to suit flexible coupling (xiv) Accessories : AVM pads built or separtely mounted to manufactrer base frames. (xv) Base frame : Made out of ISMC 250 of sturdy design made of MS channel or as recommended by manufacturer.
(g) Accoustic Enclosure : Manufactured by OEM suitable for 125 KVA DG Set (i) NAL approved as per CPCB (ii) It should be as per latest rules and regulations of Ministry of Environment and Forest and pollution control board (iii) The generating set battaries and control panel should be inside the enclosure (iv) Fuel tank should be inside the enclosure (v) contruction details/specification are as follows: (vi) Outer Body : CRCA sheet of 1.6mm thick (vii) Doors CRCA sheet of 1.6mm thick (viii) The accoustic should be composite in construction and fully assembled integral unit (ix) The batteries should be placed inside the enclosure beside the DG set on a suitable insulated plat form (x) The DG Set should be provided with external Emergency stop push button (xi) The enclosure should be suitably illluminated by CFL/FTL lamp fittings (xii) The noise level should be 75 dba at 1m under free field conditions
Testing : The DG set shall be tested for a period not less than 12 hours continuously out of which at least one hour each on No Load and 25% load, two hours each on 50% and 75 % of rated full load, six hours on rated full load and half an hour on 10% in exceess of rated full load. Necessary load shall be given on connected load. All instruments, consumable stores like engine oil, grease required for carrying out the tests including manpower shall be provided by the contractor. DDHP will be issued by the department free for use. Collection of fuel to be carried out by the contractor from MT Yard to site.
Supply and laying XLPE cable of size 120 Sqmm 3.5 core, 1100 volt grade, insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable ( Heavy duty ) with stranded aluminium conductor and connected with terminal box / panel with necessary cable lugs and gland including taking out existing unsv cable complete all as specified and as directed by Engr-in-Charge. Make: Polycab / KEI / Havells.
S&F 6 to 32 amps MCB single pole 240 V ' B ' series all as specifed and directed by Engr-in-Charge. Make: HPL / Standard / CROMPTON GREAVES.
S&F in replacemnet integral LED street light luminaire of 30 watt comprising of epoxy powder coated housing, enclosed with glass cover in frame IP 65 protection and with all fixing arrangement connecting to electric system with 2.5 Sqmm PVC aluminium cable two core upto required length on pole / wall, including bracket, testing and commissioning complete all specified and directed by Engr-in- Charge. Make: Wipro / phillips / Bajaj.
S&F PVC insulated , armoured, heavy duty electric cable with aluminium conductor,1100 volts grade, cross-sectional area 95 Sqmm 3.5 core all as specified and directed by Engr-in -Charge.
M&L for Earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly and preferably vertically in ground ( earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galavanised earth strip 32 x 6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3, connected to earthing point of outdoor panel boards all as specified including earth work and excavation in any type of soil, PCC type C1 ( 1:3:6 ) chamber & RCC type B1 ( 1:2:4 ) cover 40mm thick, with 8 mm dia steel deformed (TMT bars) reinforcement at 150 mm c/c both ways, 20 mm dia GI medium grade pipe for watering, water funnel, complete all as specified and testing on completion.
Excavation in trenches not exc.1.5 m wide and not exceeding 1.5 m in depth and getting out in soft / loose soil for foundation / laying of cable complete all as specified by Engr-in-charge.
M&L for Cement concrete type C-2 ( 1:3:6 ) (Using 40 mm gradedcrushed stone aggregate ) in foundation, filling and mass concrete all as specified and directed by Engr-in-Charge.
M&L for PCC type B1 ( 1:2:4 ) (Using 20 mm gradedcrushed stone aggregate ) as in platform / floor complete all as specified and directed by Engr-in-Charge.
Formwork to sides of concrete foundation, footing, bases of columns, raft raft beams, sides, and soffits (if any) of foundation and plinth beams and similar work vertical or to batter.
Supply and installation of silent Diesel Engine driven with AMF Panel generatiing set 415 volts, 3 phase 4 wire, engine as per IS: 10001. comprising of "KOEL" make engine modle HA294 G1 KCC iGreen Air Cooled Producing 20.5 BHP @ 1500 RPM coupled with "KOEL Green" make Alternator, mounted on a base frame. Rate including of initial filling of lube oil, testing 12 hrs countinous run + 10% overload in one hrs. Along with. a) AMF-B Type control panel b) Fuel Tank c) Battery with leads d) First fill of oil e) Engine dafeties and protection f) Anti vibration mounting pads g) Acoustis Enclosure suitable for 15.00 KVA DG set as per Latest CPCB Norms. Make: Kirloskar / CUMMINS INDIA / MAHINDRA Gen Set.
M&L for sub-main wiring with 2 runs of 4.0 Sqmm FR PVC insulated, multi-stranded, copper cable, 1100 V grade, conf to IS along with one run of 2.5 Sqmm FR PVC insulated, multi-stranded, copper cable for earth continuity wire connected to common earth dolly ( Colour code to be followed ) drawn through PVC casing and caping of size not less than 25 mm, ISI marked, fixed on surface including all accessories complete all as specified and directed. Make of cable: Polycab / Havells / Plaza.
M&L for sub-main wiring with 4 runs of 6.0 Sqmm FR PVC insulated, multi-stranded, copper cable, 1100 V grade, conf to IS along with two runs of 4.0 Sqmm FR PVC insulated, multi-stranded, copper cable for earth continuity wire connected to common earth dolly ( Colour code to be followed ) drawn through PVC casing and caping of size not less than 25 mm, ISI marked, fixed on surface including all accessories complete all as specified and directed. Make of cable: Polycab / Havells / Plaza.
S&F single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB of capacity 20 amps of 'C' charatristric , complete all as specified and as directed. Make: Legrand / L&T / C&S.
S&F Triple pole and neutral enclosure with three pin and earth plug and socket complete with one single pole MCB TP of capacity 32 amps of 'C' charatristric, complete all as specified and as directed. Make: Legrand / L&T / C&S.
S&F MCB TPN 63 Amps 10 KA ,conf to relevent IS, including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-In-Charge. Make: Legrand / Seimens / Schinder / L&T.
S&F MCB TP 40 Amps 10 KA, conf to relevent IS, including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-In-Charge. Make: Legrand / Seimens / Schinder / L&T.
S&F sheet metal enclosure for MCB, DB, TPN 415 Volts 200 amps rated busbar 4 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, conf to relevent IS, with MCB as incommer and MCB SP / TP in outgoing complete all as specified and directed by Engr-in-charge. Make: Legrand / Seimens / Schinder /L&T.
M&L for cable LT 1100 volts grade armouerd heavy duty XLPE with aluminium conductor of cross sectional area 70 Sqmm 3.5 core.
M&L for cable LT 1100 volts grade armouerd heavy duty XLPE with aluminium conductor of cross sectional area 25 Sqmm x 3.5 core.
S&F on load change over switch in sheet in sheet metal enclosure suitable for 125 amps four pole front handle operate AC 22 category confirming to IS : 13947-3 415 volts, AC 50 Hz including provn of cable of entry of 25 to 70 Sqmm 3.5 core. Make: Standerd or Equivalent make as L&T / Havells / Schnider.
Earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6.0 mm thick as per IS 3043 of 1987 buried directly in to the ground ( earth pit not less than 2.25 m deep below the ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to the galvanised earth strip by means of bolts, nuts check nuts and washers of galnanised iron strip 32 mm x 6 mm as earthing lead as shown in electric plate No -5 of SSR- Part-1 connected to earth test point all as specifed or indicated including testing on completion and necessary excavation and earth work in soft / loose soil, returning filling, disposal of surplus soil, earth pit in PCC type C-1 ( 1:3:6 ) ( Using 20 mm graded crushed stone aggregate), pit, funnel, 15 mm diia meduim grade watering pipe, 20 mm dia GI light grade earth lead protection pipe, CI frame and cover , wire copper lugs etc mesh, charcoal and common salt in alternate layer complete all as specified and directed by Engineer In Charge. Including taking down of old one.
Brick Sub Class 'B' locally available best quality laid in trenches above sand cushioning for cable protection complete all as specified and directed.
M&L for GI Tubes, 'light grade' galvanised, with all fitting and laid in floors, under road, pavement or hard standing steel water tubing bore of tube 50 mm.
M&L for excavating in post holes ( or similar holes ) each in required length, width and depth, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, and removing surplus soil to a distance n.exc 50 mtr and making good surface in soft / loose soil complete all as specified.
M&L for cement concrete type D-2 ( 1:4:8 ) (Using 40 mm graded crushed stone aggregate ) as in foundation , filling, subbase and mass concrete complete all as specified and directed.
M&L for 100 m thick PCC type B-2 ( 1:2:4 ) ( (Using 40 mm graded crushed stone aggregate ) cement concrete surface even and smooth without using extra cement as in floors.
M&L for PCC type B-2 ( 1:2:4 ) (Using 40 mm graded crushed stone aggregate ) as in posts holes, foundation filling and mass concrete and similar work etc complete all as specified and directed by Engr-In-Charge.
S&F steel work as in rafter, purlins, posts tubular ( round / square / rectangular shape of pipes as approved by Engr-In-Charge ) including post special shaped washers etc complete incl necessary nut bolts wind ties and gusset plates etc. using ERW or induction butt welded tubes conformining to IS 1161-1998 grade St-240.
M&L for MS work, angle iron, flat iron, MS plates as in brackets, cleats, fastners, wind ties, supports, base for posts etc with riveted, bolted or welded attachment complete all as specified and directed by Engr-In-Charge.
M&L for two coats of synthetic enamel paint on steel surfaces over one coat of red oxide primer incl preparation of new steel surfaces. complete all as specified and directed by Engr-In-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws / 'J' hooks/bolts as required at site and making leak proof complete all as specified and directed. Make: EVEREST / TATA BLUE SCOPE / JINDAL.
M&L for brick work with sub class ‘B’ ( modular size bricks ) straight or curved on plan exc 6 m mean radius, built in CM ( 1:6 ) complete all as specified and directed by Engr-In-Charge.
M&L for Hardcore of Broken stone or boulders of gauge n exc. 63 mm, deposit-ed, spread and lev-elled in layers n exc. 15 cm thick, watered and rammed to a true surface. complete all as specified and directed by Engr-In-Charge.
M&L for Moorum / red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering. complete all as specified and directed by Engr-In-Charge.
M&L for rendering 15 mm thick in CM ( 1:6 ) on faces of brick or concrete surfaces and finishing even and smooth complete all as specified and directed by Engr in Charge.
M&L for preparation of newly plastered or unplastered surfaces of walls and applying three coats White Wash complete all as specified and directed.
S&F mild steel framed work and steel sheet for steel gate with ends of bars welded rebated and hung as gates including, pintle hinges, hand made loocking arrrangement, wheel, track wheel, drillig for fixing of steel sheet complete all as specified and as directed and conforming to Fe-290 (Gde E-165). complete all as specified and directed by Engr-In-Charge.
Note for all items: All items executed as per specified and directed by Engr-in-charge.
POONAM ELECTRIC INDUSTRY
RAJPATI CONSTRUCTION
MORESHWAR ELECTRICALS CORPORATION
M/S RAKESH TRADERS
Vee kay construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .