Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 LAccepted-AOC | L1 | Accepted-AOC Found lowest and reasonable | |
| 2 | L2₹40.2 L+₹5.5 L (16.0%)Rejected-Finance | L2 | Rejected-Finance In order but L2 | |
| 3 | L3₹41.1 L+₹6.4 L (18.4%)Rejected-Finance | L3 | Rejected-Finance In order But L3 |
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
8 Dec 2022, 6:00 pmClosed
GE(U) E/M Meerut
Roorkee road Meerut Cantt
REPAIR AND RENEWAL OF DAMAGED PARTS OF PUMP SETS, REWINDING OF MOTORS AND REPAIR REPLACEMENT OF OTHER DAMAGED ALLIED ITEMS LIKE COLUMN PIPES, PUMP SHAFTS, CONTACTORS, ETC IN SOUTH AREA INCL ALLIED ITEMS UNDER AGE WATER SUPPLY GE (U) MEERUT.
2022_MES_562264_1
8458/E8
Open Tender
Civil Works - Water Works
Works
180 days
Meerut
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE(U)E/M Meerut
₹92,000
Yes
29 Dec 2022
10 Nov 2022
10 Dec 2022
10 Nov 2022
8 Dec 2022
24 Nov 2022
Amount
Taking Down and Supplying, laying or fixing, jointing and testing LT PVC insulated and PVC sheathed single core cable , ISI-1554 marked , with copper conductor , heavy duty 1100 Volts grade of 25 sqmm ,complete including taking down of existing unserviceable cable all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.complete all as specified and directed.
Taking down and Repair/replacement of MCCB, 4 pole, 160 Amps, Icu=35KA, 415 volts, 50 hz, AC , with fixed thermal and magnetic release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, for 50 HP motor all as specified and directed.
Taking down and Repair/replacement of MCCB, 4 pole, 200 Amps, Icu=35KA, 415 volts, 50 hz, AC , with fixed thermal magnetic release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, for 75 HP motor all as specified and directed.
S&F ( repairs) Aluminium thimble suitable for LT Aluminium cable of size up to 35 Sqmm, 3.5 core complete all as spercified and directed.
S&F ( repairs) Copper thimble suitable for LT Aluminium cable of size upto 35 Sqmm, 3.5 core complete all as spercified and directed.
Supplying, fixing and testing ( in repairs) 100 Amps, 415V, 4 pole off load changeover switch with sheet metal enclosure, side handle operated , 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers complete all as specified and directed including making connections and testing complete all as specified and directed.
Supplying, fixing and testing ( in repairs) 200 Amps, 415V, 4 pole off load changeover switch with sheet metal enclosure, side handle operated , 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers complete all as specified and directed including making connections and testing complete all as specified and directed.
Supplying, fixing and testing ( in repairs) 315/320 Amps, 415V, 4 pole off load changeover switch with sheet metal enclosure, side handle operated , 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers complete all as specified and directed including making connections and testing complete all as specified and directed.
Dismantiling electric motor carefully from borehole after disconnecting the electric connections from panel board manually or mechanically except lifting from bore holes and transporting both way to work shop and back, installation, refixing, reconnecting at site where directed after necessary repairs carried out and testing complete as directed by Engr-in-Charge for Electric motor 22.5 HP, 3 phase, 400/ 415 volts, 50 Hz of any make / type. Note:- Repairs and Parts Renewed shall be measured and paid for separately.Quoted rates deemed to include transportation charges including loading and unloading and labour charges for dismantling and refixing complete.
Dismantiling electric motor carefully from borehole after disconnecting the electric connections from panel board manually or mechanically except lifting from bore holes and transporting both way to work shop and back, installation, refixing, reconnecting at site where directed after necessary repairs carried out and testing complete as directed by Engr-in-Charge for Electric motor 50 HP, 3 phase, 400/ 415 volts, 50 Hz of any make / type. Note:- Repairs and Parts Renewed shall be measured and paid for separately.Quoted rates deemed to include transportation charges including loading and unloading and labour charges for dismantling and refixing complete.
Dismantiling electric motor carefully from boreholel after disconnecting the electric connections from panel board manually or mechanically except from lifting from bore hole and transporting both way to work shop and back, installation, refixing, reconnecting at site where directed after necessary repairs carried out and testing complete as directed by Engr-in-Charge for Electric motor 75 HP, 3 phase, 400/ 415 volts, 50 Hz of any make / type. Note:- Repairs and Parts Renewed shall be measured and paid for separately.Quoted rates deemed to include transportation charges including loading and unloading and labour charges for dismantling and refixing complete.
Assessing the repairs to be carried out to the motors after dismantling and carrying out the neccessary repairs to motors by opening the electric motor carefully removing all burnt/wornout coils cleaning the slots and rewinding with super enamelled copper wire of existing size including varnishing two coats, drying and reassembling the electric motor at site and testing the smooth running of the motor on full load for 08 hours continuously for Electric motor of capacity 75 HP 3 phase, 400/ 415 volts, 50 Hz of any size /shape and make. Note: Payment of bearing shall be measured and paid separatly under relevant items .
Assessing the repairs to be carried out to the motors after dismantling and carrying out the neccessary repairs to motors by opening the electric motor carefully removing all burnt/wornout coils cleaning the slots and rewinding with super enamelled copper wire of existing size including varnishing two coats, drying and reassembling the electric motor at site and testing the smooth running of the motor on full load for 08 hours continuously for Electric motor of capacity 50 to 60 HP 3 phase, 400/ 415 volts, 50 Hz of any size /shape and make. Note: Payment of bearing shall be measured and paid separatly under relevant items .
Assessing the repairs to be carried out to the motors after dismantling and carrying out the neccessary repairs to motors by opening the electric motor carefully removing all burnt/wornout coils cleaning the slots and rewinding with super enamelled copper wire of existing size including varnishing two coats, drying and reassembling the electric motor at site and testing the smooth running of the motor on full load for 08 hours continuously for Electric motor of capacity 20 to 22.5 HP 3 phase, 400/ 415 volts, 50 Hz of any size /shape and make. Note: Payment of bearing shall be measured and paid separatly under relevant items .
Lifting of electric motor 22.5 HP to 75 HP capacity from existing position after disconnection of all electrical connection for renewal of U/S bearing and applying grease after removal of old grease and re-installing at site where directed after refilling new grease and reconnecting all electrical connection and testing complete. Note : (a) Necessary payment for bearing shall be measured and paid separately under relevant items if required at site. (b) Quoted rate deemed to include cost of grease as required at site. (c) The contractor shall lift the motors as directed by the dept for normal servicing even if no repairs are reqd for the motor.
S & F thrust bearing No. 7220 including dismantling/taking out unserviceable thrust bearing of any make for 50 HP motor, complete all as specified and directed.
S & F thrust bearing No. 7316 including dismantling/taking out unserviceable thrust bearing of any make upto 75 HP motor, complete all as specified and directed.
S & F Thrust bearing No. 29324 including dismantling/taking out unserviceable thrust bearing of any make for 75 HP motor, complete all as specified and directed.
S & F Ball bearing No. 6312 including dismantling/taking out unserviceable thrust bearing of any make for 22.5 HP motor, complete all as specified and directed.
S & F Ball bearing No. 6316 including dismantling/taking out unserviceable thrust bearing of any make Upto 50 HP motor, complete all as specified and directed.
S & F Ball bearing No. 6311 including dismantling/taking out unserviceable thrust bearing of any make for 50 HP motor, complete all as specified and directed.
S & F Ball bearing No. 6313 including dismantling/taking out unserviceable thrust bearing of any make for 22.5 HP motor, complete all as specified and directed.
S & F Ball bearing No. 6309 including dismantling/taking out unserviceable thrust bearing of any make Upto 22.5 HP motor, complete all as specified and directed.
M & L for bearing sheet of motor of capacity up to 75 HP motor including lathe work, brazing etc complete all as specified and directed.
Dismantling carefully turbine pump set bowl assembly of any make, capacity upto 50000 GPH and size complete with out damaging any parts of the pump and setting aside in pump house for ascertaining the serviceability of existing parts with the following :- (a) Through dismantling and cleaning of complete bowl assembly items such as CI bowls, impeller, lock collets, bowl bush, suction and discharge case with GM bush including pump shaft. (b) Cleaning of all rotary and stationary parts of pump bowl assembly and making them for their satisfactory run. (c) Re-assembling the complete bowl assembly pump with all existing serviceable parts and renew the worn out unserviceable parts including S & F gasket ,lathe work and balancing of assembly others small nature of indispensable items as required for repairing. Note :- Parts renewed shall be measured and paid for separately under respective item of Schedule 'A'/BoQ at supplied only rates. Cost of labour for fixing of new parts shall be deemed to include in the rate quoted by tenderer.
Replacement of old damaged CI centrifugally cast bowl assembly complete with gun metal bush ( make as per original manufacturer) for pump of capacity up to 50000 GPH of vertical turbine pump .
Replacement of old damaged GM impeller ( make as per original manufacturer) for vertical turbine pump of capacity up to 50000 GPH of any type.
Replacement of old damagedStainless steel non magnetic pump shaft 25 to 32 mm ( make as per original manufacturer) dia suitable for 6 to 9 stage pumps (Bowl assembly) as directed .
Replacement of old damaged M.S. line shaft (bright) steel 25 to 32 mm dia 10 Ft long with MS coupling and non magnetic stainless steel sleeve ( make as per original manufacturer) all as specified and directed.
Replacement of old damaged Shaft coupling / sleeve of high carbon steel for 25 mm to 32 mm dia lineshaft (make as per original manufacturer) all aspecified and directed.
Replacement of old damaged GM Bush for suction case of VT pump ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged CI guide spider heavy duty with rubber bush and check nut suitable for 25 to 32 mm dia lineshaft of 150 mm bore pipe ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged CI guide spider heavy duty with rubber bush and check nut suitable for 25 to 32 mm dia lineshaft of 200 mm bore pipe ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged Rubber packing for discharge head upto 200 mm bore complete all as specified ( make as per original manufacturer) all aspecified and directed.
Replacement of old damagedRubber bush for guide spider for 25 to 32 mm dia lineshaft ( make as per original manufacturer) all aspecified and directed.
Replacement of old damagedStainless Steel top shaft not exceeding 32 mm dia and 3 mtr long, duly threaded both ends and made suitable slot for fixing the stainless steel key adjusting nut & lock washer ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged CI Centrifugally cast suction case with GM Bush (make as per original manufacturer) all aspecified and directed.
Replacement of old damaged CI Centrifugally cast discharge case with GM Bush ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged Mild steel cold drawn ERW column pipe 3.00 M long, wall thickness not less than 7.2 mm thick, 150 mm bore, both ends flanged with Mild steel column coupling 12 mm thick including welding, flanged joint on both ends complete all as specified and directed by Engr-in-Charge
Replacement of old damaged Mild steel cold drawn ERW column pipe 3.00 M long, wall thickness not less than 7.2 mm thick, 200 mm bore, both ends flanged with Mild steel column coupling 12 mm thick including welding, flanged joint on both ends complete all as specified and directed by Engr-in-Charge
Replacement of old damagedRatchet assembly complete with ratchet plate, ratchet balls hexagonal bolts etc suitable for up to 75 HP electric motor and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged Ratchet plate suitable upto 75 HP VT motor and vertical turbine pump ( make as per original manufacturer) all aspecified and directed..
Replacement of old damagedGM neck ring suitable for 100mm/150mm/200m dia VT pump and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged PVC rubber Gasket 3 mm thick suitable upto 200 mm bore flanged joints .
Replacement of old damaged Rubber bowl bush suitable for VT pump set and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.
Replacement of old damagedIntermediate bowl bush GM suitable for VT pump set and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged GM Impeller lock collect suitable for VT pump set and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.
Replacement of old damagedCI fitting box (Gland box) of suitable type & shape for VT Pump and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged Mild steel full threaded bolts of suitable size having hexagonal head with one 3 mm thick washer and nut suitable for jointing 100/150/200 mm bore flanged joints complete all as specified.
Replacement of old damagedGun Metal split gland of any size & shape with G I clamp suitable for gland box of VT pump and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.
Lowering of turbine pump set any type and capacity upto 50000 GPH re-assembling of all accessories and column pipe after cleaning manually including fixing of motor in existing position making all Electrical & water supply connections and adjustment of pump load etc and testing of pump and motor after installation all as directed by Engr-in-Charge.
Cutting, facing of existing mild steel cold drawn ERW column pipe upto 200 mm dia to desired length and re-threading up to 80 mm run to suit existing coupling complete all as directed. Note :- Rate quoted by tenderer shall be deemed to include all transportation charges from site to work shop and back incl loading/unloading.
Cutting, facing of existing mild steel lineshaft up to 32 mm dia to desired length and re-threading up to 80 mm run as directed. Note :- Rate quoted by tenderer shall be deemed to include all transportation charges from site to work shop and back incl loading/unloading.
Cutting existing MS/BS/SS top shaft of size upto 32 mm dia making slot for key and rethreading both ends for required length to suit the coupling and load adjusting shaft nut all as directed by EIC.
Taking out rusted after disorienting old worn pump M S foundation bolt from cement concrete foundation base and fixing by providing new mild steel full threaded bolt of 20 mm dia not exc.300 mm long with proper cement concrete foundation (1:2:4) type B-1 using 20mm graded crushed stone aggregate and makeing the surface smooth to match with existing surface complete all as directed.
Repairing the base of discharge head of VT pump up to 50000GPH by Welding and renewing high carbon steel nut for the base of discharge head, including renewal of mild steel channel complete all as directed.
Renewal of Heavy duty terminal plate made of bakelite suitable for electric motor of capacity 30/40/50/75 HP with brass nuts of suitable size best quality as approved by GE complete all as specified and directed.
Renewal of Terminal plate cover made of CI for fixing over the terminal plate with cover for 30/40/50/ HP electric motor best quality as approved by GE complete all as specified and directed.
Labour for lifting of submersible pump along with flanged column pipe, submersible cable, safety rope etc from the existing bore well by using suitable T&P etc after disconnecting submersible cable from starter making necessary repairs by opening and renewal of parts as required including transportation to market and back for repair complete all as specified & directed for 22.5HP to 41 HP capacity pumpset. Note: Parts Renewed shall be measured and paid separately at supply only rates.
Labour for lifting of submersible pump along with flanged column pipe, submersible cable, safety rope etc from the existing bore well by using suitable T&P etc after disconnecting submersible cable from starter making necessary repairs by opening and renewal of parts as required including transportation complete all as specified & directed for 2HP to 7.5 HP capacity pumpset. Note: Parts Renewed shall be measured and paid separately at supplied only rates under appropriate item(s).
Supply only Gunmetal impellers suitable for 22.5 to 41 HP Submersible pump
Supply only Gunmetal bush suitable for 22.5 to 41 HP Submersible pump
Supply only stainless steel sleeve suitable for 22.5 to 41 HP Submersible pump
Supply only 'C' type bushes for impellers suitable for 22.5 to 41 HP Submersible pump
Supply only Bowel case suitable for 22.5 to 41 HP Submersible pump
Supply only stainless steel shaft of standard size complete in all respect suitable for 22.5 to 41 HP Submersible pump
Supply only Gunmetal impellers suitable for 2 to 7.5 HP Submersible pump
Supply only Gunmetal bush suitable for 2 to 7.5 HP Submersible pump
Supply only stain less steel sleeve suitable for 2 to 7.5 HP Submersible pump
Supply only 'C' type bushes for impellers suitable for 2 to 7.5 HP Submersible pump
Supply only Bowel case suitable for 2 to 7.5 HP Submersible pump
Supply only stainless steel shaft of standard size complete in all respect suitable for 2 to 7.5 HP Submersible pump
Lowering down of submersible pump set along with connected items such as column pipes ,submersible cable by using suitable T&P and reconnecting all electrical connections,commissioning & testing complete all as specified & directed for 22.5 HP to 41 HP capacity pumpset.
Lowering down of submersible pump set along with connected items such as column pipes ,submersible cable by using suitable T&P and reconnecting all electrical connections,commissioning & testing complete all as specified & directed for 2 HP to 7.5 HP capacity pumpset.
Rewinding of submersible motor electric driven , AC supply with PVC insulated copper wire (ISI marked) as per existing gauge ,including connected works for rewinding .The scope of works includes dismantaling ,removal of old winding wire ,cleaning of slots & rewinding ,reassembling,testing complete all as specified & as directed for 22.5 HP to 41 HP capacity of pump motors. Note: Other parts required for repair will be measued and paid for separately under respective sch item.
Supply only Gunmetal bush for submersible motor suitable for 22.5 to41 HP
Supply only Thurst bearing for submersible motor suitable for 22.5 to 41 HP
S & F (in repair) Submersible cable flat ,water proof,PVC insulated, PVC sheathed,3 core,16 sqmm,1100 volts grade ,multistranded copper conductor including making water proof cable joint with submersible motor and normal connections through lugs/thimbles into starter panel complete all as specified and directed.
S & F (in repair) Submersible cable flat ,water proof,PVC insulated, PVC sheathed,3 core,16 sqmm,1100 volts grade ,multistranded copper conductor including making water proof cable joint with submersible motor and normal connections through lugs/thimbles into starter panel complete all as specified and directed.
S & F (in repair) Submersible cable flat ,water proof,PVC insulated, PVC sheathed,3 core,16 sqmm,1100 volts grade ,multistranded copper conductor including making water proof cable joint with submersible motor and normal connections through lugs/thimbles into starter panel complete all as specified and directed.
Supply & fix Single/reverse phase preventor for motor protection with by pass arrangements to run the motor in case of emergency with low/high voltage cut off and time delay/relay of 1 to 3 sec.including dismantling/taking out of unserviceable phase preventor of any make and type complete all as specified and directed.
Taking down and S&F Thermal Over load relay of range 65 to 110 Amps (for 3 phase,415 V motor of 75 HP) complete all as specified.
Taking down and S&F Over load relay of range 45 to 75 Amps (for 3 phase,415 V motor of 50 HP) complete all as specified.
Taking down and S&F Thermal Over load relay of range 28 to 36 Amps (for 3 phase,415 V motor of 22.5 HP) complete all as specified.
Supply & Fixing of Power contactor 3 pole above 50 HP upto 75 HP with 415 V/220 V , AC Coil including repair/replacement of wiring complete all as specified.
Taking down and S & F Power contactor 3 pole upto 50 HP with 415 V/220V , AC Coil including repair/replacement of wiring complete all as specified.
Taking down and S & F Power contactor 3 pole upto 25 HP with 415 V/220V , AC Coil including repair/replacement of wiring complete all as specified.
Taking down and S & F only Thermal timer type GT 200, including wiring operating voltage 230/250 Volts, 400/440 Volts, 50 Hz fun 5-18 seconds range complete all as specified.
S&F (in repair) phase sequence changer of any type /make capacity 22.5 HP to 75 HP including renewal of U/S parts and wiring as required to made the sequencer serviceable condition.
Taking down of RYB phase indicator and S & F of RYB phase indicator of any size and type on LT Panel as specified and directed.
Taking sown of old unserviceable panel and supply,installation,commissioning and testing of Micro processor Controlled based Master Monitoring &operating panel via ultra sonic sensors for Boring pump set for Automatic pump Controlling for 1 No boring pump set via 1 No ultra sonic sensor for 1 No Over Head Tank to operate thewater Supply system & act as a usercontrolled with Visual annunciation panel & with Cordless Transmitter /receiverunit modem Vsat satellite controllednet work with micro chipvsat antenna &Non GSM (Non Sim Based)/GPRS/Internet Based Transmission for SCADARemote monitoring & operation of complete water supplyoperation Vsat Satellite controlled. The Panel shall be wall/Floor mounting of suitable size made of 1.5 sqmm CRCA sheet Properly Powder coated ,consisting of following features :- (To be installed at Pump house no 23):- a) Main Micro Processor Controller Data Receiver/Transmitter unit Modem Vsat satellite controlled Communication Net work and Non GSM/GPRS/Internet based transmission b) With Single/Reverse phasing, Over/Under Voltage, Dry Running of pump set & Over/Under Current protection & alarming through SMS to five mobile no’s c) Micro controller based complete monitoring system for pump motor three phase Voltage current, P.F & KWH d) With SCADA Soft Ware transmitter For Mobile Phone for monitoring of water level of 1 no OH Tank via mobile phone app and 32” LED Screen Receiver unit In mimic graphic format Non internet ,Non Gprs,Non GSM (Non Sim Based) Non RF & Non Rtu based but satellite controlled network (e) The micro controller shall send SMS Alert to five mobile no’s in case of any tampering with the automatic pump controllers or the system g) With automatic chlorine pump operation out put pot . h)With Mimicgraphic display of Size 12” /12” High Intensity Type LED Micro processor based for water level indicator from 0%,5%,10%,15%,20%,25%,30%,35%,40%,45%,50%,55%,60%65%, 70%,75%,80%,85%,90%,95% & 100% & 1 nos Delivery Line Motorize valve open/close Running Graphical Mimic. i) With automatic controlling of pump set ON/Off Condition via ultra sonic sensor j) With SMPS Power supply 230 Vac ,10 Amp ,12 VDC Make :- Megha Automation/U.E.E /Rockwell Automation
Taking down of old unserviceable panel and supply,installation, commissioning and testing of Micro processor Controlled Master Monitoring &operating panel for automatic controlling of 1 No delivery line motorize valve as pre set timing (To be installed at Over Head Tank of ph no 23) to operate the Delivery valve automatically with inverter back up of 500 VA in case of power failure& act as a user controlled with Visual annunciation panel & with Cordless Transmitter/receiver unit modem Vsa satellite controlled with inbuilt Vsatmicro chip antenna &Non GSM/GPRS/Internet/Rf/RTU /iRTU based Net work for SCADA Remote monitoring & operation of complete water supply operation Vsatsatellite controllednet work. The Panel shall be wall/Floor mounting Shall be of suitable size made of 1.5 sqmm CRCA sheet Properly powder coated ,consisting of following features:- a) Main Micro Processor Controller Data Receiver/Transmitter unit Modem Vsat satellite controlled with inbuilt Vsatmicro chip antenna And Non GSM/Non GPRS/Non Internet/Non Rf/Non RTU/ Non iRTU based net work b) With automatic controlling of delivery line motorize valve via pre set digital timer. c) With SCADA Soft Ware For Mobile Phone for manually controlling of delivery line motorize valve Open/Close in case of emergency via mobile phone App Delivery Valve Open/Close Button non internet Based but Satellite controlled Network d) With Inverter Backup of 600 VA With Battery in case of power supply failure e) With SMPS Power supply of 10 Amp 230VAC-12VDC Make :- Megha Automation/U.E.E /Rockwell Automation
Taking down of old u/s sensor and supply ,installation, testing & Commissioning of Ultra sonic non contact sensor for level monitoring for over head tank with Following specification: - Principal:- Ultra sonic sound waves water level sensing O/P Pot :- 4-20 ma/0-20 V Data transmitting out put pot SCADA Operation out put pot Range 6mts Make:- Micro Devices/Crystal/U.E.E/banner
Taking down old u/s transmeter and supply , installation, testing & commissioning of wireless Vsat satellite transmitter modem with Vsat Inbuilt Vsatmicro chip antenna and Non internet Non computer,NonRF,Non GPRS and Non GSM ( Non Sim Based) to Transmit Water level Data of 1 Nos OH Tank Via 32” LED Screen and mobile app in flash format with smps power supply with with SCADA Operating soft waresatelliteControlled with SMPS Power supply 12 V 10 Amp all enclosed in powder coated MS box of suitable size Make :- Megha Automation/U.E.E /Rockwell Automation
Integrating the existing automated system of other PHs with this new system into single app software and into singlee display screen for control and function all as diected by Engt-in Charge.
Supply and fixing of 4 (core) X 1.5 Sqmm PVC insulated armoured Copper cable with heavy duty Saddles 60 cm apart complete all as Specified and directed by Engineer-in-charge. Make:Larsen/Grindlay/Delton/giloster
Supply and fixing of 6 (core) X 1.5 Sqmm PVC insulated armoured Copper cable with heavy duty Saddles 60 cm apart complete all as Specified and directed by Engineer-in-charge. Make:Larsen/Grindlay/Delton/giloster
Supply and fixing of 2 (core) X 1.5 Sqmm PVC insulated armored Copper cable with heavy duty Saddles 60 cm apart complete all as Specified and directed by Engineer-in-charge. Make:Larsen/Grindlay/Delton/giloster
S & F in repair of high torque motorize valve with gears and adopters self Lubricating Type, Weather proof with protection against , over voltageJamming of valve and over current protection with manual by-pass arrangementto open/Close the valve on power failurewith Following specification: - (a) Valve Size:-150 MM (b) Designed line pressure 15 kg/sq cm (c) Operating angle; - 90 degree (d) Disc Material :- CI with nylon coating (e) Valve type :-Butterfly valve with geared motor on top (f) With Scada modem for manually opening/Closing of motorize valve via mobile Aneroid software App Close/Open Buttons Non Internet based ringer tone based in case of emergency ;-R.C/ U.E.E /Siemens/Honeywell
Supply,fixing,testing and commissioning (in repair) of Motor Protection Circuit Breaker (MPCB) for motor capacity 20HP to 75HP 3 POLE/4 POLE to include features of protection/tripping from over current, under current, high voltage/low voltage, dry run, earthing, over-load, short circuits, thermal protection as directed by engineer in charge. (MAKE Schneider,Simens, L&T, ABB or equivalent)
Taking down old BER VT motor 50HP including pump set 40000 GPH ( 5 stage) & depositing to store as directed by Engr-in-Charge.
Dismentling of old u/s motor with pump set and S&F energy efficent hollow shaft motor with pump set for 150mm outlet diameter of 50HP, 4 pole 1460RPM,3 phase, 50Hz with non reversible rechet assembly suitable for motor coupling shaft dia 30.1mm dia complete including pumping set 61 Mtr head (5 Stage), 40000 GPH all as specified and directed.
Repair/replacement of motor gland leakage including replacement of studs, plate, and other assessories/ items all as directed by Engr-in-Charge.
S&F (in repair/replacement) of fully automatic ,3 phase Star delta starter with enclosure suitable for motor upto 50HP capacity including connector & cables required all as directed by Engr-in-Charge.
S&F (in repair/replacement) of fully automatic ,3 phase Star delta starter with enclosure suitable for motor above 50HP upto 75HP capacity including connector & cables required all as directed by Engr-in-Charge.
Repair of LT panel body its doors & covers of size 1.20 x 1.0 mm size by suitable means of including cutting, welding, and sheet metal work required as directed by Engr-in-Charge. The job also description incomplete includes cost of painting the entire panel after repairs using exporty powder & suitable paint.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick burried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, connected to galvanised iron or steel, earth strip 32 x 6 mm size by means of nuts, bolts check nuts and washers made of galvanised iron or steel, earth wire protected by galvanised iron pipe 15mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC ( 1 : 3 : 6) type C1, pre-cast RCC cover slab 30 cm x 30 cm x 10 cm with one lifting handle made of 8 mm dia MS bar funnel wire mesh, 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal or coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical Plate No 5 of MES Schedule Part- I and testing on completion . (Concrete pit shall be 20 cm to 30 cm away from main pit) including taking out old earthing.
Repair for motor foundatrion size of 1.6 mtr X 1.0 mtr X 0.5 mtr with replacement of rusted nut and bolt of required size including PCC (1:2;4) type B-I and necessary demoliation work All as directed by Engr-in -Charge.
S&F Repair/renewal of digital type 3 Phase, 415V , 50HZ electronic energy meter at various pump Houses and direct connected 5/20Amp CT, 10/60Amp CT operated direct reading type meter with indication LCD having accuracy wide voltage fluctuation from -40% to +20% and should give accurate reading under rapid current fluctuation and accurate for balance as well as unbalance load including anti tamper feature complete all as specified and directed.
Taking down old unserviceble NO-NC based automatic motor Cut-off relay based on water level of OHT and S&F New NO-NC based water level controlled auto motor Cut-off relay including testing &commissioning as directed by Engr-in-Charge.
M K ENGG CO
SUPERTECH ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .