| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-AOC H NO 465 SECTOR 20 P II PANCHKULA | PANCHKULA | HARYANA | 133301 | ₹16.3 L Quoted ₹16.4 L | L1 | Accepted-AOC L1 |
| 2 | L2₹16.5 L+₹14,514.10 (0.89%)Rejected-AOC HOUSE NO 156 VILLAGE CHAPRA P O BITHA AMBALA | AMBALA | AMBALA | HARYANA | ₹16.5 L+₹14,514.10 (0.89%) | L2 | Rejected-AOC L2 |
| 3 | L3₹17.3 L+₹94,523.05 (5.77%)Rejected-AOC BOOTH NO 119 ECTOR 9 PANCHKULA | PANCHKULA | HARYANA | 133301 | ₹17.3 L+₹94,523.05 (5.77%) | L3 | Rejected-AOC L3 |
| 4 | L4₹17.6 L+₹1.2 L (7.42%)Rejected-AOC NA | NA | NA | 121004 | ₹17.6 L+₹1.2 L (7.42%) | L4 | Rejected-AOC L4 |
Tender Value
₹18.1 L
EMD Value
₹36,280
Closing Date
18 Jun 2026, 10:00 amClosed
Ashok Kumar Rana
Electrical Panchkula
PROVIDING 200 KVA TRANSFORMERS AND HT/LT LINES IN SHOPPING CENTER OF SECTOR-4 (PART-II) U/E KURUKSHETRA. (INCLUDING SIX YEARS DEFECT LIABILITY PERIOD FOR TRANSFORMER AND THREE YEARS FREE MTC. AND DEFECT LIABILITY PERIOD FOR OTHER ITEMS, FREE OF COST)
2026_HBC_527834_1
2026467B6298 C92D 4468 A5B3 2F4453982B33245HSV
Open Tender
Electrical Works
Works
90 days
Kurukshetra (Thanesar)
2 documents required · 2 mandatory
₹500
₹36,280
Yes
24 Jul 2026
9 Jun 2026
19 Jun 2026
9 Jun 2026
18 Jun 2026
9 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | [23.26.2]SAFETY ITEMS 2. Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages. [Through Rate] | 27 | Each | 93 | ₹2,511 |
| 2 | [24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate] | 19 | Each | 2,721 | ₹51,699 |
| 3 | [24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate] | 19 | Each | 652 | ₹12,388 |
| 4 | [24.1.6]EARTHING AND LIGHTENING ARRESTOR 6. Supplying and laying 25mm x 3mm G.I. strip at 0.5 metre below ground as strip earth electrode including soldering etc. as required. [Through Rate] | 270 | Metre | 47 | ₹12,690 |
| 5 | [24.16.7]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 7. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 185 Sq mm 3 core [Through Rate] | 190 | Metre | 1,531 | ₹2,90,890 |
| 6 | [24.2.8.10]LT CABLE 8.10. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 120 sqmm [Through Rate] | 24 | Each | 32 | ₹768 |
| 7 | [24.2.8.14]LT CABLE 8.14. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work.300 sqmm [Through Rate] | 24 | Each | 91 | ₹2,184 |
| 8 | [24.3.4.2]HT CABLE 4.2. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 150 to 185 sqmm [Through Rate] | 4 | Set | 13,199 | ₹52,796 |
| 9 | Supply and Erection of LT PVC unarmoured cable of size 300 Sqmm single core with aluminium conductor 650/1100 V conforming to ISS 1554 (Part-I) of 1988 IS: 7098/Part-1/ 1988 with latest amendments up to entire satisfaction of Engineer-in-charge (Make: Grandlay, Polycab, Havells, CIRTINA (Excluding GST 18%). | 72 | Metre | 594 | ₹42,768 |
| 10 | Supply, installation, testing, commissioning of 3 Phase 11KV/0.433 KV-250V, 200 KVA Oil immersed, naturally cooled, Aluminum Wound Outdoor type Distribution Transformers with CSP (Completely self protected ) features with external microprocessor based four pole MCCB 300 Amp. To 400Amp., 50kA strictly conforming to Nigam’s technical specification No. CSC-V/R-I/DH/UH/P and D/2010-2011 read with amendment thereof and as per relevant ISS as amended from time to time and losses conforming to 4 star rating of BEE as per Appd. Make and Specification of UHBVN/UHBVN including installation of transformer on existing platform up to the entire satisfaction of Engineer-in-Charge. (Excluding GST 18%)
Voltage Rated Frequency Permitted at 75ºC
i) Maximum load losses at 50% load at 75ºC = 780 Watt
ii) Maximum losses at 100% load at 75ºC = 2300 Watt
iii) Warranty = 72 Months shall be one time
The above losses are maximum allowable and there would not be any positive tolerance. (Excluding GST 18%) | 3 | Per Metre | 2,57,458 | ₹7,72,374 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.92 MB
BOQ_606828.xls
BOQ • 0.34 MB
AD0158393.pdf
Additional Documents • 0.60 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .