| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 LAccepted-AOC 1492 SECTOR 40 B CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | ₹1.5 L | L1 | Accepted-AOC L1 |
| 2 | L2₹1.7 LRejected-Finance 38A PHASE II RAVINDRA ENCLAVE BALTANA PB | ₹1.7 L | L2 | Rejected-Finance not L1 |
| 3 | L3₹1.7 LRejected-Finance 1090 GROUND FLOOR SECTOR 18 C CHANDIGARH | ₹1.7 L | L3 | Rejected-Finance not L1 |
| 4 | L4₹2.4 LRejected-Finance 6 GURU GOBIND SINGH NAGAR DHAKOLI ZIRAKPUR | S A S NAGAR | PUNJAB | 140103 | ₹2.4 L | L4 | Rejected-Finance not L1 |
Tender Value
₹2.0 L
EMD Value
₹3,962
Closing Date
20 Jan 2026, 11:00 amClosed
Executive Engineer, Electrical Division, M.C., Chd
Executive Engineer, Electrical Division, M.C., Chd
REPLACEMENT OF OLD DAMAGED UNDERGROUND CABLE TO NEW ONE IN AREAS SECTOR- 38 WEST, 39, 40, 41, 44, 51, 52, 61 UNDER SUB DIVISION NO. 3, M.C., CHANDIGARH.
2026_MCC_89903_2
01/E/MCC/2026
Open Tender
Electrical Works
90 days
REPLACEMENT OF OLD DAMAGED UNDERGROUND CABLE TO NE
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹3,962
10 Apr 2026
13 Jan 2026
20 Jan 2026
13 Jan 2026
20 Jan 2026
13 Jan 2026
Supply & laying of ISI marked 4 core 16 mm sq PVC Insulated Aluminium armoured cable loose in trench/pipe:- Supply & laying of ISI marked 4 core 16 mm sq PVC Insulated Aluminum conductor armoured cable (PVC Sheathed) of make Sunhome/ Finolex/ Cirtina/ Ecko/ Lapp/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable to be laid in trench/ pipe as per DSR Code 7.5.1/2022 MV CB PIP-25 Part-II (External). The cable should be terminated existing/ new cc collar with proper thimbling. The job included all Connections, Commissioning and testing of phase supply Material Testing report to be submitted and material to be supplied at site after confirmation from Engineer-in-charge. The specification of the cable as below:- i) Conductor – Aluminum ii) Core – 4 iii) Working Voltage – 1100 V iv) Nominal Cross Section – 16mm2 v) Minimum No. of Wire – 7/6 vi) Insulation Thickness – 1.0mm (Nominal) vii) Inner Sheath Minimum Thickness – 0.3mm viii) Outer Sheath Minimum Thickness – 1.40mm ix) Nominal size of Armoured Wire/Strip – 4x0.8mm x) Approximate O.D. – 22mm Maximum d.c. Resistance at 20 Deg. C – 1.91 ohm/km The work shall be executed to the entire satisfaction of Engineer-in-Charge.
Supply & Laying of DWC pipe 51/63mm with hand bockey:- DSR 14.15.1 (75 cm below) Supply and Laying of pipe (OD-63 mm & ID-51 mm nominal) Double Wall Corrugated (DWC) With Hand Bockey High Density Polyethylene pipe ISI marked (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm maintenance free, ‘C’ value over 150 with lowest frictional losses, good weathering resistance, with all accessories like socket, bend, couplers etc. conforming to IS 14930/ IS 16205 complete with fitting and cutting, jointing etc.direct in ground (depth as per the direction of Engineer in charge or upto 75 cm below ground/ road level by digging the ground or cutting the road/ paver blocks upto required level & laying of DWC pipe for laying L.T. upto 1.1 KV grade) cables etc. including excavation and refilling the trench but including sand cushioning and protective covering etc., complete as required and PSEN-50086 (P-I & II) of Make Gemini, Rex, Duraline. The entire satisfaction of Engineer-in-Charge of work.
Supply & Laying of DWC pipe 51/63mm without hand bockey:- DSR 14.16.1 (75 cm below) Supply and Laying of pipe (OD-63 mm & ID-51 mm nominal) Double Wall Corrugated (DWC) Without Hand Bockey High Density Polyethylene pipe ISI marked (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm maintenance free, ‘C’ value over 150 with lowest frictional losses, good weathering resistance, with all accessories like socket, bend, couplers etc. conforming to IS 14930/ IS 16205 complete with fitting and cutting, jointing etc. direct in ground (depth as per the direction of Engineer in charge or upto 75 cm below ground/ road level by digging the ground or cutting the road/ paver blocks upto required level & laying of DWC pipe for laying L.T. upto 1.1 KV grade) cables etc. including excavation and refilling of digging including sand cushioning and protective covering etc., complete as required and PSEN-50086 (P-I & II) of Make Gemini, Rex, Duraline. The entire satisfaction of Engineer-in-Charge of work.
Supply& Erection of PVC insulated 2 core 10mm2 aluminium conductor twin core flat unarmured cable to fixed on the suitable clamp and nuts/ bolts etc make Rolex/ Sunhome/ Polycab/ Shalimar/ Havell's.The work shall be executed to the entire satisfaction of Engineer-in-Charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
techsummary_110120.pdf
BOQ Comparative Chart
xlsx
finsummary_110120.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.49 MB
BOQ_110120.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid