Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC | ₹1.0 Cr | L1 | Accepted-AOC L.-140 |
| 2 | L2₹1.1 CrRejected-Finance BALUMATH LATEHAR | LATEHAR | JHARKHAND | 822111 | ₹1.1 Cr | L2 | Rejected-Finance ATTACHED. |
| Sl No | Description | Qty | Unit | DIPAK KUMAR L2 | MADHUMOHAN CONSULTING AND CONSTRUCTIONS PRIVATE LIMITED L1 |
|---|---|---|---|---|---|
| 1.00 | EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I. 5.1.1/BCD | 169.92 | cum | 155 ₹26,337.60 | 149.16 ₹25,345.80 |
| 2.00 | Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume) 5.1.10/BCD | 45.57 | cum | 595 ₹27,115.94 | 579.19 ₹26,395.59 |
| 3.00 | Providing designation 75- A, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge. 5.6.1/BCD | 455.73 | sqm | 360 ₹1.6 L | 350.28 ₹1.6 L |
| 4.00 | Providing P.C.C. M-15 with nominal mix of (1:2:4) in Foundation with approved quality of stone metal grade III (53 to 22.4 mm size) and clean coarse sand of F.M. 2.5 to 3 including screening, , mixing cement concrete in mixture, placing in position, vibration, striking, curing, taxes and royalty all complete as per building specification & direction of E/I. 5.3.1.2/BCD | 35.19 | cum | 4,600 ₹1.6 L | 4,517.76 ₹1.6 L |
| 5.00 | Providing R.C.C. M-20 with nominal mix of (1:1.5:3) in FOUNDATION and plinth with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including , mixing cement concrete in mixer, placing in position vibrating striking curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I. 5.3.1.1/BCD | 49.95 | cum | 5,000 ₹2.5 L | 4,874.9 ₹2.4 L |
| 6.00 | Providing designation 75-A brick work in C.M. (1:6) in foundation & plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints,cost of screening materials raking out joints to 15mm depth , curing, taxes & royalty all complete as per building specification & direction of E/I. 5.2.3/BCD | 25.98 | cum | 5,460 ₹1.4 L | 5,344.65 ₹1.4 L |
| 7.00 | Providing designation 75-A BRICK WORK in CM. (1:6) in SUPERSTRUCTURE with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening,racking out joints to 15 mm depth,curing, taxes and royalty all complete as per building specification and direction of Engineer Incharge. 5.2.11/BCD | 143.78 | cum | 5,600 ₹8.1 L | 5,476.13 ₹7.9 L |
| 8.00 | Providing and laying cement concrete in retaining walls,return walls(any thickness) including attached pilasters,columns,piers,abutments,pillars,posts,struts,buttresses,string or lacing courses,parapets,coping,bed blocks etc. upto floor five level excluding the cost of centering,shuttering,finishing and reinforcement with 1:1.5:3( 1 cement :1.5 coarse sand(zone -iii) : 3 graded stone aggregate 20 mm nominal size.) BCD 5.3.2.1 | 23.83 | cum | 6,000 ₹1.4 L | 5,884.9 ₹1.4 L |
| 9.00 | Reinforced cement concrete works in beams,suspended floors,roofs having slope upto 150 landings,balconies,shelves,chajjas,lintels,bands,plain windows sills,staircases and spiral staircases above plinth level upto floor five level excluding the cost of centering,shuttering,finishing and reinforcement with 1:1.5:3( 1 cement :1.5 coarse sand(zone -iii) : 3 graded stone aggregate 20 mm nominal size.) BCD 5.3.11 | 137.73 | cum | 6,350 ₹8.7 L | 6,198.46 ₹8.5 L |
| 10.00 | Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings . 5.3.17.1/BCD | 91.2 | SQM | 200 ₹18,240 | 191.1 ₹17,427.98 |
Tender Value
₹1.1 Cr
EMD Value
₹2.1 L
Closing Date
2 Mar 2026, 5:00 pmClosed
EE, NREP, KHUNTI.
EE, NREP, KHUNTI.
Construction of 06 Additional Classroom at Residential Upgraded High School, Tapkara, Torpa,Khunti. (No. of Unit-06)
2026_NRPKH_110515_1
NREP/KHUNTI/F2-10/2025-26
Open Tender
Civil Works
335 days
KHUNTI
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹2.1 L
13 May 2026
25 Feb 2026
5 Mar 2026
25 Feb 2026
2 Mar 2026
25 Feb 2026
EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I. 5.1.1/BCD
Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume) 5.1.10/BCD
Providing designation 75- A, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge. 5.6.1/BCD
Providing P.C.C. M-15 with nominal mix of (1:2:4) in Foundation with approved quality of stone metal grade III (53 to 22.4 mm size) and clean coarse sand of F.M. 2.5 to 3 including screening, , mixing cement concrete in mixture, placing in position, vibration, striking, curing, taxes and royalty all complete as per building specification & direction of E/I. 5.3.1.2/BCD
Providing R.C.C. M-20 with nominal mix of (1:1.5:3) in FOUNDATION and plinth with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including , mixing cement concrete in mixer, placing in position vibrating striking curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I. 5.3.1.1/BCD
Providing designation 75-A brick work in C.M. (1:6) in foundation & plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints,cost of screening materials raking out joints to 15mm depth , curing, taxes & royalty all complete as per building specification & direction of E/I. 5.2.3/BCD
Providing designation 75-A BRICK WORK in CM. (1:6) in SUPERSTRUCTURE with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening,racking out joints to 15 mm depth,curing, taxes and royalty all complete as per building specification and direction of Engineer Incharge. 5.2.11/BCD
Providing and laying cement concrete in retaining walls,return walls(any thickness) including attached pilasters,columns,piers,abutments,pillars,posts,struts,buttresses,string or lacing courses,parapets,coping,bed blocks etc. upto floor five level excluding the cost of centering,shuttering,finishing and reinforcement with 1:1.5:3( 1 cement :1.5 coarse sand(zone -iii) : 3 graded stone aggregate 20 mm nominal size.) BCD 5.3.2.1
Reinforced cement concrete works in beams,suspended floors,roofs having slope upto 150 landings,balconies,shelves,chajjas,lintels,bands,plain windows sills,staircases and spiral staircases above plinth level upto floor five level excluding the cost of centering,shuttering,finishing and reinforcement with 1:1.5:3( 1 cement :1.5 coarse sand(zone -iii) : 3 graded stone aggregate 20 mm nominal size.) BCD 5.3.11
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings . 5.3.17.1/BCD
Centering and shuttering including strutting, propping etc. and removal of form for Columns,pillars. 5.3.17.6/BCD
Centering and shuttering including strutting, propping etc. and removal of form for Lintel,beams. 53.17.5/BCD
Centering and shuttering including strutting, propping etc. and removal of form for in suspended floors,roofs. BCD 5.3.17.3
Providing T.M.T. Reinforcement FE 500 of following dia Rods as per approved design and drawing including carriage of M.S. Rods of (Straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction and direction of E/I. (APPROVED BRAND - TATA/ SAIL)
5.5.4/BCD 8MM DIA.
5.5.5 A/BCD 10 MM DIA.
5.5.5 B/BCD 12-16 MM DIA.
Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) 5.5.12/BCD
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron) DSR 21.1.2.2
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):21.3.1 With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) DSR 21.3.1
Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows skylight, fanlights and C/W celetial windows openings, including wedge over all clamps complets including application of two coats of wood preservative of approved quality on the surface butting walls and lintels complete as per building specification and direction of E/I. BCD 5.4.1Pg No-113
Supplying, fitting and fixing 35mm thick solid core type non decorative single leaf flush door shutters in doors and windows with black board core bended with high quality phenol formal dehydes synthetic resin both side commercial veneered of standard make with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I. BCD 5.4.38 Pg No-116
Providing two coats of synthetic enamel paint of approved shade and make over new wooden surface including prepairing the surface after cleaning, removing dirt, cales,smokes,grease and sand papering, including cost of scaffolding and taxes all complete as per building specification and direcition of E/I. BCD Corrigendum 5.8.32 Pg No-133
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning,removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification) 5.8.41/BCD
Providing two coats of painting with synthetic enamel paint with one coat of primer of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l. 5.8.45/BCD
Providing 6mm cement plaster(1:4) in ceiling with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I . 5.7.6 /BCD
Water proofing of old and new roof slab :- providing and laying water proofing treatment on roof slab by applying two components,factory designed ----do---- all comp. BCD 5.12.1
Covering of treated surface with PCC: Providing 25 mm thick cement concrete M-20 (1:1.5:3) maintaining slope in alternate 2M X 2M panels with approved quality of materials do all comp. BCD 5.12.2
Providing and laying 25 mm thick kotah stone slab flooring of approved texture,size and colour over 19 mm thick base of lime mortar(1:1:1) laid and joined with grey cement slurry -do- all comp. (iv) 600x600 mm size. BCD 5.6.19
Providing and laying 25 mm thick kotah stone tiles in risers of steps,skirting and pillars of approved texture,size and colour over-do- all comp. (iv) 600x600 mm size. BCD 5.6.20
Providing 12 mm Thk. cement plaster(1:6) on inside walls with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I . 5.7.3/BCD
Making plinth protection 50 mm thick of cement concrete (1:3:6) over 75 mm dry brick ballast ---- all complete as per direction of E/I. DSR 4.17
Providing 150mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. 5.10.34/BCD
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the urface evn and smooth. DSR 13.26
Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over a new surface including preparing the plastered surface by rubbing smooth, with pumice stone or fine sand paper applying putty wherever required scalfolding. washing of floors and taxes. all complete as per building specification and direc tion of E/I.BCD 5.8.20
Providing and applying white cement based putty of average 1 mm thickness over plastered surface to prepare the urface evn and smooth. DSR 13.80
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqmover and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 5.8.21/BCD
Providing and fixing Fan Hooks of 16 mm dia M.S. Bar 1m long ----- complete as per direction of E/I. BCD 5.5.13
providing and fixing on wall face unplasticised - rigid P.V.C pipes -110 mm dia.. DSR 12.41.2
providing and fixing on wall face unplasticised - PVC moulded fittings and accessories of 110 mm dia. -do -all comp. DSR 12.42
COUPLER 110 MM
TEE 110X110X110 MM
providing and fixing on wall face unplasticised PVC pipe clips to fix rain pipes to wall -do- all comp. DSR 12.43
Providing earth work in filling in compound by carriage all complete as per direction of E/I .5.1.8/BCD
CARRAIGE OF MATERIALS
(I)CEMENT
(II)SAND
(III)STONE CHIPS
(IV)BRICKS
(V)STEEL,
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Energy 1.3.2 Group B Pg No-66
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.Energy 1.5 Pg No-66
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.Energy 1.7 Pg No-67
1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.7.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
1.7.11 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required..Energy 1.21 Pg No-69
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Energy 1.24 Pg No-70
1.24.1 5/6 A switch
1.24.4 3 pin 5/6 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.Energy 1.25 Pg No-70
Supplying and fixing suitable size GI/PVC box of 121mm x 173mm x 48mm (6"x8") (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc as required. Energy 1.30 Pg No-71
Supplying and fixing following three pole and neutral sheet. MCB distribution board.415 V …. As required 4 way (8+12), TPN, vertical type, MCB DB, double door Energy 2.10.3 Pg No-77
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Energy 2.12.1 Single pole Pg No-78
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.Energy 2.14.1 Pg No-78 40A TPN
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal/ coke and salt ) as required Energy 3.2 Pg No-80
Supplying and laying 8 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.Energy 3.7 Pg No-80
Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.Energy 4.2 Pg No-82
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.Energy 4.4 Pg No-82
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)Energy 4.7 Pg No-82
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)Energy 4.8 Pg No-82
Providing and fixing of 1200 mm Ceiling Fan M-772 Pg No-52
Providing and fixing of 50/60 watt LED Flood Light Energy 9.2.2 Pg No-89
Providing and fixing of wall/ceiling light fixtures with 15/16W CFL lamp. Energy M-856 Pg No-54
Goods & Services Tax (G.S.T.) @ 18%
Labour Cess @ 1%
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
BOQ_149419.xls
BOQ • 0.36 MB
DOC_2.pdf
Tender Documents • 0.53 MB
Download all tender documents and submit your bid