Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC SHOP NO 82 6 TRANSPORT NAGAR NARWAL JAMMU 180004 | JAMMU | JAMMU | J K | 180004 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹29.6 L+₹1.3 L (4.71%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
18 Jun 2024, 6:00 pmClosed
GE NAGROTA
GE NAGROTA
REPAIR AND MAINTENANCE OF EXTERNAL PIPE LINE, SLUICE VALVE MOTORS STARTERS AND CONNECTING ITEMS AT VARIOUS LOCATION UNDER GE NAGROTA
2024_MES_654010_1
CA NO GEN-11/2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
NAGROTA
Class D category b ii
8 documents required · 8 mandatory
₹50
GE NAGROTA
₹56,000
Yes
25 Sept 2024
15 May 2024
25 Jun 2024
15 May 2024
18 Jun 2024
1 Jun 2024
Amount
SCHEDULE ‘A’ PART-I Taking out existing unserviceable/serviceable CI/MS/GI/PVC/CPVC/UPVC Pipe 300 mm bore from the trenches including disconnecting branch connections, fittings and control valves complete all as specified and directed (Excavation and earth work shall be measured and paid for separately).
All as per srl item No 1 above but 250mm bore
All as per srl item No 1 above but 200mm bore
All as per srl item No 1 above but 150mm bore
All as per srl item No 1 above but 100mm bore
All as per srl item No 1 above but 80mm bore
Supply and Lay Mild steel pipe 300mm bore IS-3589(1981) with 6mm thickness (ERW) with all fittings such as MS flanged , gasket with required no of holes, MS connecting piece suitable size of nut and bolts and washers, MS bends, connecting piece etc complete all as specified.
Supply and laying DI K 9 tubings medium grade ISI Mark with all fittings such as elbow, bends, sockets, nipples and union etc and fixed complete laid in trenches for the 250 mm bore including taking down all as specified and directed by Engr-in-charge :-
All as per item No 8 above but 200 mm bore DI K-9 tubings medium grade
All as per item No 8 above but 150 mm bore GI tubings medium grade
All as per item No 8 above but 100 mm bore GI tubings medium grade
All as per item No 8 above but 80 mm bore GI tubings medium grade
Supply and fix Foot valve for 200 mm bore including GI flanged Bolts/Nuts/washers gasket etc all and removal of old valve and fixed complete all as specified and directed
Supply and fix Foot valve for 150mm bore including GI flanged Bolts/Nuts/washers gasket etc all and removal of old valve and fixed complete all as specified and directed
All as per item No 14 above but 100 mm bore pipe.
All as per item No 14 above but 80 mm bore pipe.
Supply and fix Air Release valve for 100mm bore including GI flanged Bolts/Nuts/washers gasket etc all and removal of old valve and fixed complete all as specified and directed Note : The quoted rate shall include for cutting of existing pipe for fixing of Air Valve
All as per item No 17above but 80 mm bore pipe.
Supply and fix Non Return Valve for 200 mm bore including GI flanged Bolts/Nuts/washers gasket etc all and removal of old valve and fixed complete all as specified and directed
All as per item No 19 above but 150 mm bore pipe.
All as per item No 19 above but 100 mm bore pipe.
All as per item No 19 above but 80 mm bore pipe.
Excavating in trenches n exe 1.5 m wide and not exceeding 1.5 m in depth getting out hard/dense soil complete all as specified and directed
Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm in hard dense soil complete all as specified and directed
Removing excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed
Material and labour for heavy duty sluice valve 300mm bore complete with iron wheel conforming to IS 1538,PN 1.6 of double flanged and drilled end provided with high tensile steel spindle including GI flanged Bolts/Nuts/washers gasket etc all and removal of old valve of following sizes :
All as per item No 26 above but 200 mm bore pipe.
All as per item No 26 above but 150 mm bore pipe.
All as per item No 26 above but 100 mm bore pipe.
All as per item No 26 above but 80 mm bore pipe.
Material and labour for heavy duty butterfly valve 150mm bore complete with iron wheel conforming to IS 1969,PN 1.6 of double flanged and drilled end provided with high tensile steel spindle including GI flanged Bolts/Nuts/washers gasket etc complete all as specified & directed
Material and labour for Repair to foot valve 200 mm bore in position by replacement of UNSV parts such as leather packing, Rubber packing,, nuts, bolts, washers etc. complete all as required to make it functional complete all as specified & directed
Material and labour for Repair to foot valve 150 mm bore in position by replacement of UNSV parts such as leather packing, Rubber packing,, nuts, bolts, washers etc. complete all as required to make it functional complete all as specified & directed
Material and labour for construction of brick valve pit of brick masonry of size 600 x600 x 600mm internal dimension complete with Angle Iron, 3.15mm thick MS sheet cover and locking arrangement including excavation and earth work and P.C.C 1:3:6 type with provision of two coat of synthetic enamal paint over one coat of red oxide primer including demolition of existing valve pit complete all as specified and directed.
Material and labour for construction of valve pit of brick masonry of size 900 x 900 x 900mm internal dimension complete with Angle Iron, 3.15mm thick MS sheet cover and locking arrangement including excavation and earth work and P.C.C 1:3:6 type with provision of two coat of synthetic enamal paint over one coat of red oxide primer including demolition of existing valve pit complete all as specified and directed.
Material and labour for construction of valve pit of brick masonry of size 1000 x 1000 x 1000mm internal dimension complete with Angle Iron, 3.15mm thick MS sheet cover and locking arrangement including excavation and earth work and P.C.C 1:3:6 type with provision of two coat of synthetic enamal paint over one coat of red oxide primer including demolition of existing valve pit complete all as specified and directed.
Disconnecting of all electrical connection for taking out unserviceable centrifugel pump of any size from the foundation including other accessories carrying to workshop for repair complete all as specified and directed. Note: Spare part measured and paid under relivent items.The cost of transportation to workshop is deemed to be included in the quoted rate.
M & L for Replacement the defactive part of centrifugel pumps Set are as under cap 5 to 125 HP:-
Impeller of existing size as directed by Engr-in-Charge
Gland bush including gland packing of existing size as directed by Engr-in-Charge
Pump shaft of existing size as directed by Engr-in-Charge
Neck ring any size as directed by Engr-in-Charge
Remetaling, grinding, polishing and balancing of shaft for induction motor of capacity 5 to 10 HP. Note: (i) The rate for replacement of bushes, shaft sleeves etc required for making the shaft functional shall be included in the quoted rate).
All as per item No 43 above but of cap 10 to 20 HP
All as per item No 43 above but of cap 20 to 30 HP
All as per item No 43 above but of cap 40 to 60 HP
All as per item No 43 above but of cap 75 to 125 HP
Supply and fixing in replacement of ball bearing of induction motor/pump of cap 5 to 15 HP as per existing size complete all as specified and directed
Supply and fixing in replacement of ball bearing of induction motor/pump of cap 20 to 30 HPas per existing size complete all as specified and directed
Supply and fixing in replacement of ball bearing of induction motor/pump of cap 40 to 60 HP as per existing size complete all as specified and directed
Supply and fixing in replacement of ball bearing of induction motor/pump of cap 75 to 125 HP as per existing size complete all as specified and directed
Supply and fixing in replacement of star coupling suitable for connecting centrifugal motor and pump of capacity upto 125 HP complete all as specified and directed.
Supply and fixing in replacement of Tyre coupling suitable for connecting centrifugal motor and pump of capacity upto 125 HP complete all as specified and directed.
Material and labour for rewinding of centrifugal motor of any description, dismantling and strip opening of the motor, removing the old existing burnt windings, cleaning the slots and rewinding of the electric motor of 3 phase, 415 Volts, 50 Hz AC supply with existing gauge copper wire ( 99.99 % purity) including insulating material such as illumines paper, etherized paper, cotton waste, glass sleeves insulating varnish etc, refixing on existing platform and connected all the electric connections and mechanical connections and testing the complete pumping set up to the entire satisfaction of the Engr-in-Charge for Upto 5HP capacity complete all as specified and directed.
All as per item No. 54 above but capacity 5 HP to 15 HP
All as per item No. 54 above but capacity 15 HP to 20 HP
All as per item No.54 above but capacity 25HP to 30 HP
All as per item No 54 above but capacity 35 HP to 40 HP
All as per item No. 54 above but capacity 50 HP to 60 HP
All as per item No. 54 above but capacity 60 HP to 75 HP
All as per item No. 54 above but capacity 125 HP.
Disconnecting the electrical connection for taking out unserviceable submersible pump set any size from the bore well including column pipe and other accessories carrying to workshop for repair & back to site complete all as specified and directed. Note:- (i) T&P required for lifting and lowering for submersible pump set column pipe (any number) shall be provided by the contractor. (ii) Necessary safety precautions for workmen shall be the responsibility of the contractor. (iii) The cost of transportation to workshop is deemed to be included in the quoted rate.
M & L for Lowering the servicable submersible pump set any size after repair shifted to in its orignal location joint with column pipe and other accessories connecting to all electrical connection testing and commissioning the same complete all as specified and directed. Note: The cost of transportation from workshop is deemed to be included in the quoted rate.Necessary safety precautions for workmen shall be the responsibility of the contractor.
M & L for Replacement the defactive part of submersible pump sets are as under:-
Thrust plate of submersible motor 5 HP to 40 HP
Thrust bearing of submersible motor 5 HP to 40 HP
Gun metal bushes for submersible motor 5 HP to 40 HP
Remetaling,grinding,polishing and balancing of shaft for submersible motor 5 HP to 40 HP
Coupling arrangement with key of submersible motor of cap 5 HP to 40 HP
Stainless steel shaft of submersible pump of cap 5 HP to 40 HP
Impellers for submersible pump set 5 HP to 40 HP
Bowl bush for submersible pump set 5 HP to 40 HP
Neck ring for submersible pump set 5 HP to 40HP
M & L for removing old existing burnt windings of the submersible motor cleaning the slots for rewinding, and rewinding the motor with super enamelled copper winding wire superior quality ( 99.99 % purity) as per exisitng gauge and size, varnishing, drying, replacement of bearings and assembling the motor of Cap up to 12.5 HP complete all as specified and directed.
M & L for removing the burnt winding wire of the submersible motor cleaning the slots for rewinding, and rewinding the motor with super enamelled copper winding wire ( 99.99 % purity) superior quality as per exisitng gauge and size, varnishing, drying, replacement of bearings and assembling the motor of Capcity from 15 HP to 40 HP complete all as specified and directed.
M & L in replacement of sand guard assembely of 5 HP to 40 HP submersible Motor as existing make and size all as specified and directed.
M & L in replacement of bush housing set including bush of 5 HP to 40 HP submersible Motor as existing make and size all as specified and directed.
M & L in replacement of upper housing set of 5 HP to 40 HP submersible Motor as existing make and size complete all as specified & directed
M & L in replacement of lower housing set of 5 HP to 40 HP submersible Motor as existing make and or size complete all as specified & directed
M & L in replacement of mechanical seal of 5 HP to 40 HP submersible Motor as existing make and size complete all as specified & directed
M & L in replacement of seal guide sleeve of 5 HP to 40 HP submersible Motor as existing make and size complete all as specified and directed
M & L in replacement of startor assembly along with winding wire of 5 HP to 40 HP submersible Motor as existing make and size complete all as specified and directed
M & L in replacement of roter assembly of 5 HP to 40 HP submersible Motor as existing make and size complete all as specified & directed
M & L in replacement of cable connector sleeve and spring guide plate of 5 HP to 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of tie rod/tie bolt of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of diaphragm along with diaphargm spring of 5 HP to 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of doom nut and "O" ring of 5 HP to 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
Disconnecting the electrical connection for taking out unserviceable VT Motor of any size from the foundation of bore well and other accessories carrying to workshop for repair including all electrical connection testing and commissioning complete all as specified and directed. Note: Spare part measured and paid under relivent items.
M & L for removing the burnt winding wire of the VT motor, cleaning the slots for rewinding, and rewinding the motor with super enamelled copper winding wire ( 99.99 % purity) superior quality as per exisitng gauge and size, varnishing, drying, of Capacity 30 to 40 HP complete all as specified and directed.
M & L for Lowering the VT pump any size after repair shifted to in its orignal location joint with column pipe,motor and other accessories connecting to all electrical connection testing and commissioning the same complete all as specified and directed. Note: The cost of transportation from workshop is deemed to be included in the quoted rate.
M & L for Replacement the defective part of VT pump sets are as under up to 40 HP Vertical turbine Motor :-
Neck Ring
Gland plate
Studs
Stainless steel line shaft 3 metre long
Guide spider 6"
Guide spider bush
Stainless steel sleeve
Shaft coupler
Thrust bearing
B Kulf bush
Split Ring
M& L for Opening and checking and repair of fully automatic solid state CC-4A,CB-4SA,CC-4P,CC-4A models fault analyzer cum control system with (a) Low voltage cut off 350 Volt AC (b) High Voltage Cut off 450 Volt AC (c) Pick up volt 360 Volt AC (d) Cut off time- Fraction of time (e) Unbalanced volt cut off- a deference of 35Volt to 45 Volt between any two phase with 3 phase over load protection (f) Relay contact rating 5 Amps resistence at 230 V AC or 1 Amp at 415V AC (e) 4 LED fault indicators (Make: Guardian) once in a month to make it functional at all the times for smooth operation of pumping set installed at various location of water supply installations. Note : Minor parts of the system will be replaced during checking and the cost of the same is deemed to be included in the quoted rate.
Disconnecting and transport to workshop and complete connection after disconnecting of voltaze stablizer, opening for repair automatic voltage stabilizer for automatic operation air natural/oil cooled servo controlled type input voltage 260-440V and output voltage 420 V capacity 25 to 400 KVA complete all as specified and as specified and as directed (Note :- (i) Cost of transportation of voltage stabilizer to workshop and back after repair complete is deemed to be included in the quoted rate. (ii) Replacement of the parts if any found worn out/defective shall be measured and paid for separately.
Supply and fixing in replacement of dimmer coil with super enameled copper winding wire of existing make and size complete in all respect including varnishing tapping and insulating material to get same capacity of 25 to 400 KVA complete all as specified and directed.
Supply and fixing in replacement of electronic circuit plate complete with DC transformers and shape (PCB cold ) Upto 400 KVA complete all as specified and directed.
Dismantling of old servo motor and supply and fix new servo motor of upto 150 KVA Voltaze Stablizer and shape along with all connected accessories and cap complete all as specified and directed.
Dismantling of old carbon bush with carbon holder incl S & F new carbon bush with carbon holder of upto 400 KVA Voltaze Stablizer size and shape complete all as specified and directed
Supply and fixing in replacement of brass studs fixed for upto 400 KVA Voltaze Stablizer input and output of stabilizer with brass nuts along with all necessary connection complete all as specified for any capacity of Voltage Stablizer complete all as specified and directed
Supply heating and filling of transformer oil EHV grade having dielectric strength not less than 45 KV (Rms) with a 4 mm gap with high viscosity in transformer as per IS-335 of 1983 complete all as specified and directed
Supply and fixing in replacement, of power contractors 3 phase, 3 pole, 415 Volts, 50 Hz suitable for operation of a load of capacity of 70 Amps complete all as specified and directed .
Supply and fixing in replacement, of power contractors 3 phase, 3 pole, 415 Volts, 50 Hz suitable for operation of a load of capacity of 110 Amps.complete all as specified and directed
Supply and fixing in replacement, of power contractors 3 phase, 3 pole, 415 Volts, 50 Hz suitable for operation of a load of capacity of 185 Amps.complete all as specified and directed
M & L for Taking down of manually operated oil immersed star delta starter of any capacity from its existing position, removing the transformer oil in a suitable container for reuse, replace the old unserviceable fixed and moving contract, over load coils, no volt coil complete and refixing the starter assembly in its existing position connecting the complete system and making the starter functional complete all as specified and directed.
M & L for Servicing / maintenaace of Air Blowers of adequate capacity (not less than 250 cfm) coupled with electric driven AC induction Motor of cap 20 HP three phase including carrying out maintenace check along with following repairs (a) Dismantling of Twin lobe commpressor in presence of MES representative and display all the parts without damage any portion for inspection of Engr in Charge to ascertain the serviceability of existing parts and assembling the same after filling compressor oil No 320 or as existing, upto indicated level. (b)Heating, varnishing to stator, rotor with super qualityvarnish and drying out properly. (c) Cleaning, washing and greasing of ball bearing complete. (d) Assembling of motor with old serviceable parts and replacement of UNSV parts with new as ordered where necessary. (e) Installation of motor by making connections as per existing and testing on load complete. Note:- Any minor repair and replacement of parts like bearing,gasket, gland packing, Nuts bolts washers, Gear oil of compressor etc and labour cost to be included in the quoted rates. (ii) Rewinding of motor if required shall be measured and paid to be included in the quoted rates
Taking down of LT Panel star delta starter of any capacity from its existing position, removing the Burnt contactors ,replace the old unserviceable fixed and moving contract, over load coils, no volt coil complete and refixing the starter assembly in its existing position connecting the complete system and making the starter Panel functional complete all as specified and directed.
Supply and fix Flat three core PVC insulated & PVC sheathed industrial cable of size 10 Sqmm to 12 Sqmm for submersible pump motors complete all as specified and directed.
Supply and fix Flat three core PVC insulated & PVC sheathed industrial cable of size 25 to 35 Sqmm for submersible pump motors complete all as specified and directed
Supply and fixing in replacement of MCCB 400 Amps 4 pole 415 Volts 36 KA with adjustable thermal and adjustable magnetic settings fixed in repair as per existing at site complete all as specified and directed
Supply and fixing in replacement of MCCB 250 Amps 3 pole 415 Volts 36 KA with adjustable thermal and adjustable magnetic settings fixed in repair as per existing at sitecomplete all as specified and directed
Supply and fixing in replacement of MCCB 200 Amps 3 pole 415 Volts 36 KA with adjustable thermal and adjustable magnetic settings fixed in repair as per existing at site complete all as specified and directed
Supply and fixing in replacement of MCCB 100 Amps 3 pole 415 Volts 16 KA fixed type as per existing at site complete all as specified and directed
Supply and fixing in replacement of volt meter as per existing size complete all as specified and directed.
Supply and fixing in replacement of Amp meter with CT as per existing size complete all as specified and directed.
Supply and fixing in replacement of indicator lamp assembly complete LED type suitable for the existing system supply voltage for the existing system supply voltage 230V / 440 V AC including taking down old lamp assembly complete all as specified and directed
Supply and fixing copper thimble of following sizes
35 sqmm Heavy duty
50 sqmm Heavy duty
70 sqmm Heavy duty
90 sqmm Heavy duty
Nitika electricals and engineers works
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .