Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 LAccepted-AOC | L1 | Accepted-AOC Being overall reasonable | |
| 2 | L2₹35.0 L+₹99,664 (2.93%)Rejected-Finance 67 A HAFIZALI BAHADUR KHAN MARG SURAJI COMPOUND BEHIND KHATAU MILL BYCULLA W MUMBAI 400011 BRITE INDUSTRIES 67 A HAFIZALI BAHADUR KHAN MARG SURYAJI COMPOUND BEHIND KHATAU MILL MUMBAI | MUMBAI | MAHARASHTRA | 400011 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹37.5 L+₹3.5 L (10.4%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹40.4 L+₹6.4 L (18.9%)Rejected-Finance GALA NO B 128 129 130 SATYAM INDUSTRIAL ESTATE OFF KARVE ROAD OPP SNDT COLLEGE ERANNDWANE PUNE 411038 PUNE MAHARASHTRA 411038 | PUNE | MAHARASHTRA | 411038 | L4 | Rejected-Finance Not lowest bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
27 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
REPAIR MAINTENANCE OF VARIOUS CENTRAL PACKAGE TYPE AC PLANTS AND ITS RELATED WORKS SUCH AS REPLACEMENT OF FILTERS V BELTS PULLYS CONTROLS AT 512 ABWS CAFVD UNDER AGE EM II C IN GE C KIRKEE
2020_MES_356988_1
8365/E8 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
260 days
KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹96,000
Yes
19 Sept 2020
30 Jun 2020
29 Jul 2020
30 Jun 2020
27 Jul 2020
15 Jul 2020
30 Jun 2020 - 14 Jul 2020
60 days
Amount
Disconnecting water connections to the condenser of package/central A/C plant of following capacity by dismantling the both end cover of condenser. Descaling the condenser of compressors with dilute sulphuric acid and flushing/cleaning with brush and water and re-fixing the side cover with new gasket nut / bolts and detect leakage all as specified and directed by Engineer -in-Charge. Note : Dilute sulphuric acid for descaling is deemed to be included in the quoted rates.
Material and Labour for for Servicing/Cleaning of FRP cooling towers of following capacity by dismantling top cover, fan with fan motor and removing the honey comb frills. Cleaning of base tray & frills, pot strainer etc. servicing of fan motor with changing of bearings and greesing refixing the fan, frill & top cover testing commissioning complete all as directed by Engr-in-charge. Note : Spares as required during the servicing and repairs as declared unservicable by Engr in charge shall be mesured and paid under relavant items of this schdule.
16 TR to 45 TR
50 TR to 100 TR
110 TR to 200 TR
Disconnecting/Isolating the compressor from the system by putting plates to the suction and discharge valve opening of the compressor. Dismatling the compressor completely by taking down the crank shaft. Removing unserviceable internal parts cleaning overhauling complete replacement of worn out parts such as suction reed, discharge reed, cylinder liners, loading/unloading system of compressor, washers, nut bolts, gaskets shaft seal, "O" rings, cutting, metalizing, grinding, balancing the crank shaft and reassembling the compressor including changing the compressor oil, leak testing with nitrogen, repairing leakages and charging R-22, gas, testing/comissioning complete for following compressor make Accel sabro/Kirloskar, complete all as directed by engineer in charge. Note : Spare parts , R-22 gas, compressor oil and nitrogen gas shall be measured and paid separately under respective items.
Supply and fixing in replacement of following spares for compressor make :- Kirloskar/Accel / Sabro 8-65/6-65/4-65 model. All as specified & directed .
Piston
Piston ring
Pisotn pin
Shaft seal assembly
Discharge valve reed
Loading Unloading Frame
Main bearing Bush
Connecting rod bearing
Gasket set for 6-65
Gasket set for 8-65
Gasket set for 4-65
Aluminium washer set
Oil pump assembly
Oil ring
O Ring set
Solenoid valve for loading & unloading
Split pin
Sunction valve reed
Thrust collor
Oil filter
Cylinder liner
Oil drain valve
Bushing for connecting rod
Crank shaft complete for SMC 6-65
Crank Shaft for SMC 8-65
Supply and fixing in replacement of following spares for compressor of AC-470 (Make : Kirloskar) all as directed by Engr-in-charge.
Connecting rod assembly
Piston
Piston ring
Gudgeon Pin
Shaft seal assembly
Paper filter
Sunction valve reed
Discharge valve reed
Gasket set
O ring set
Solenoid valve
Main Bearing
Cylinder liner
Oil drain valve
Oil pump assembly
Crank Shaft for AC - 470
Supply and filling nitrogen gas for leak testing of central & package A/C plants all as directed by Engr-in-charge.
Supply and filling of R-22 Gas in central & package A/C plants all as directed by Engr-in-charge
Supply and fillling compressor oil suitable to air conditioning plants compressor and taking out old dirty compressor oil, cleaning the crank case and oil filter all as directed by Engr-in-charge.
Supply and fixing in replacement of defective brassomatic pressure releas valve of suitable size for 300 PSI refrigerent gas pressure complete.
Dismantling, Removing the unserviciable spares from A/C plant of any make & supply & fix new spares for A/C plant of following specifications all as directed by Engr-in-charge.
HP/LP cutout MP 15R
Oil Pressure Switch MP 55
Teflone TAL- O Ring 50 & Tal 40
Brass angle valve 1/4" for freon gas
1 1/8" Brass valve Teflone sheet
Site glass sperion or equivalent
Adaptor for valve 3/8" x 1/4"
Supply & fixing in replacement of over load relays type MN relay range 14-23 A complete all as specified . Make : L & T or equvilant to BCH/SIMENS
Supply & fixing in replacement of over load relays type MN relay range 24-40 A complete all as specified . Make : L & T or equvilant to BCH/SIMENS
Supply & fixing of MCCB 63 Amps 25KA, TP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete Make :- L & T or equvilant to ABB/Legrand
Supply & fixing of MCCB 100 Amps 36KA, TP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete Make :- L & T or equvilant to ABB/Legrand
Supply & fixing of MCCB 125 Amps 36KA, TP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete Make :- L & T or equvilant to ABB/Legrand
Supply & fixing of MCCB 200 Amps 36KA, TP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete Make :- L & T or equvilant to ABB/Legrand
Supply & fixing of MCCB 200 Amps 36KA, FP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete Make :- L & T or equvilant to ABB/Legrand
Supply & fixing of MCCB 250 Amps 36KA, FP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete. Make :- L & T or equvilant to ABB/Legrand Note : For item No 13.00 to 28.00 - (i) All cable connections should be done with supply and fixing suitable size lugs/thimble etc. (ii) Any addition / alteration to sheet metal enclosure existing panel for fixing of MCCBs and removal of old u/s switch gear is deemed to be included in the rates quated.
Supply & fixing in replacement of following spares for central AC plant :-
Indicating lamps RYB - 01 Set
V ' belt of size / No A 28 make - Fenner
V ' belt of size / No B 85 make - Fenner
V ' belt of size / No B 108 make - Fenner
V ' belt of size / No C 156 make - Fenner
Power Contactors ML1.5 Make - L & T or equvalant to Simens/BCH
Power Contactors ML2 Make - L & T or equvalant to Simens/BCH
Power Contactors ML3 Make - L & T or equvalant to Simens/BCH
Power Contactors MNX 18 Make - L & T or equvalant to Simens/BCH
Power Contactors MNX 25 Make - L & T or equvalant to Simens/BCH
Power Contactors MNX 40 Make - L & T or equvalant to Simens/BCH
Power Contactors MNX 50 Make - L & T or equvalant to Simens/BCH
Power Contactors MNX 70 Make - L & T or equvalant to Simens/BCH
Labour only for detection of leakage and repairing of central type AC Plant of capacity 24 TR to 60 TR capacity by leak testing, leak repairing, pressure testing with nitrogen, vacuumising complete system of central type AC plant with double stage vacuume pump of atmospheric pressure less than 28 to 30mm/HG and charging of refrigerant gas upto required pressure after satisfactory results. Note :- Nitrogen gas and refrigerant will be measured and paid separately.
Dismantling of Air Handling Unit of any capacity with complete accessories such as cooling coil ,air filters,blower motor, blower / drum ,blower shaft,side panels , and wall opening if required etc including removing of electric connection and dismantling of pipe work of any size and type by using gas cutter or Electric cutter complete all as specified and directed.
Re-assembling/Refixing the complete Air Handling Unit of any capacity after carring out cleaning, servicing to cooling coil, blower & filters by using CTC solution including remetling, fine grinding blower shaft and hardening balancing, realignment to AHU shaft, replacing unserviceable blower fins ,replacing bearings 2 Nos including inlet out let pipe welding,all electric connections and leak testing by using nitrogen gas and testing and commissioning all as specified and directed by Engr-in- Charge.
Supply and fixing Cast iron Sluice valves class PN 1.6 of size 100mm dia (4") incl gasket, nutbolts, handle with cuting of CI pipe fabrication work as per site requirment & incl removal of Unsv Sluice valves complete all as specified and directed Engr-in-Charge.
Supply and fixing Cast iron Sluice valves class PN 1.6 of size 80mm dia (3") incl gasket , nutbolts,handle with cuting of ci pipe fabrication work as per site requirment & including removal of Unsv Sluice valves complete all as specified and directed Engr-in-Charge.
Taking out unserviceable liquid line valve/discharge line valve from refrigerant line of different size/type for necessary replacement all as directed including cutting / welding of existing pipe line complete.
Supply and fixing liquid line valve/discharge line valve as per existing including providing Gasket/Taflon/bushing to both side sheet, suitable for 40 mm dia pipe line including brazing/welding,fixing all as diected and specified.
Supply and fixing liquid line valve/discharge line valve as per existing including providing Gasket/Taflon/bushing to both side sheet, suitable for 25 mm dia pipe line including brazing/welding,fixing all as diected and specified.
Supply and fixing liquid line valve/discharge line valve as per existing including providing Gasket/Taflon/bushing to both side sheet, suitable for 20 mm dia pipe line including brazing/welding,fixing all as diected and specified.
Supply and fix thermostate expansion valve of suitable size for 22TR/30TR capacity air conditioning plants including taking down the unserviceble valve.
Supply and Fix thermostate expansion valve of suitable size for 15TR capacity air conditioning plants including taking down the unserviceble valve.
Supply and Fix thermostate expansion valve of suitable size for 7.5TR capacity air conditioning plant including taking down the unserviceble valve.
Supply and Fix thermostate expansion valve of suitable size for 5TR capacity air conditioning plants. including taking down the unserviceble valve.
Supply & fixing water pressure gauge 0-7 Kg/Sqmtr including taking down the unserviceble gauge.
Supply& fixing refrgerant pressure gauge 30 to 150 PSI including taking down the unserviceble gauge.
Supply and fix in replacement of pressure release valve of condensor 3/8" BSP threaded suitable for 300 PSI.
Supply and Fix in replacement of DB/WB thermometer wall mounted with the facility of RH readings.
Taking down carefully and overhauling of Monoblock pump set by disconnecting the pump from foundation and pipe line, dismantling of shaft from the pump, replacing the unserviceable wornout bearing, gland packing, seal and bushing and assembling after repairs complete testing for the pump:-
7.5 HP to 10 HP
12.5 HP to 20 HP
Material and Labour in replacement of 50mm bore GI pipe medium grade incl all fitting and acessories complete all as directed.
Material and Labour in replacement of 40mm bore GI pipe medium grade incl all fitting and acessories complete all as directed.
Material and Labour in replacement of 25mm bore GI pipe medium grade incl all fitting and acessories complete all as directed.
Material and Labour in replacement of 20mm bore GI pipe medium grade incl all fitting and acessories complete all as directed.
Supply and fix Gate Valves (Brass Insert) of 50 mm bore, ISI marked , heavy duty incl taking down old one complete all as directed.
Supply and fix Gate Valves (Brass Insert) of 40 mm bore, ISI marked , heavy duty incl taking down old one complete all as directed.
Supply and fix Gate Valves (Brass Insert) of 25 mm bore, ISI marked , heavy duty incl taking down old one complete all as directed.
Supply and fix Gate Valves (Brass Insert) of 20 mm bore, ISI marked , heavy duty incl taking down old one complete all as directed.
Supply & fix float valve/ball type assemblt complete of size 20 mm size dia.
Painting of CI/GI/MS pipes of Air / Water distribution of size 100 / 80 mm dia along with side supports complete with two coats of synthetic enamel paint all as per colour code directed by Engr-in-Charge.
Material and Labour for earthing complete with galvanized steel earth plate Electrode 600mm x 600mm x 6mm thick buried directly in ground earth pit not less than 2.25 meters deep below ground level with top edge of the plate not less than 1.5mt below GL connected to 32 x 6mm GI streep upto 7.5 m long by mean of GI bolts ,nuts,check nuts & wasters and connected to earthing test point & earth dolly all as shown in electrical plate No 3 of SSR part I 2009 & as specified and testing on completion including earth work & excavation in any type of strata , PCC (1:3:6) type chamber precast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric of XPM, weight not less than 4 Kg /Sqm) with cast iron frame ,funnel with water pipe of 20mm dia GI medium grade, wire mesh and lugs etc complete all as directed by Engr-in-charge.
Supply and Fix Earth continuity conductor or main earthing lead of size 25 x 3mm Aluminium strip fixed to wall on poreclion/PVC insulator buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthling etc. incl removal of old strips as required all as specified and directed.
Material and Labour for Mild Steel brackets, frames ,supports, channels and stands of type as required at site made out of angle iron, flat or strip of grade Fe-410-S of any size as per site requirement for PGI air duct etc complete all as specified and as directed by Engr-in-charge .
Supply and fix double nitted polymer fabric HDPE fresh air filter washable/cleanable type having efficiency 95% to 99% down to particle size of 5 to 20 micron, fabricated out of CRCA sheet metal duly painted with two coat of grey hammer tone spray painted over two coats of red oxide primer, with lifting handle, Box/flanged type, aluminium spacer etc, all as specified by Engr-in-charge of sizes 630 x 500 x 50mm.
Supply and fix double nitted polymer fabric HDPE fresh air filter washable/cleanable type having efficiency 95% to 99% down to particle size of 5 to 20 micron, fabricated out of CRCA sheet metal duly painted with two coat of grey hammer tone spray painted over two coats of red oxide primer, with lifting handle, Box/flanged type, aluminium spacer etc, all as specified by Engr-in-charge of sizes 630 x 400 x 50mm.
Supply and fix double nitted polymer fabric HDPE fresh air filter washable/cleanable type having efficiency 95% to 99% down to particle size of 5 to 20 micron, fabricated out of CRCA sheet metal duly painted with two coat of grey hammer tone spray painted over two coats of red oxide primer, with lifting handle, Box/flanged type, aluminium spacer etc, all as specified by Engr-in-charge of sizes 610 x 610 x150mm.
S&F filter "HEPA' with fibre glass paper filtering media capacited 1000 CFM efficiency 99.97% down to particle size of 0.3 micron aluminium frames box type of size 610 x 610 x 300mm incl taking down old filter all as specified & directed by Eng - in - charge Note:- cleaning of duct and minor fabrication of duct to be done all as specified by Engr-in-charge.
Material and Labour for for Copper piping 5/8" (18/20 gauges) with necessary fitting such as elbow bends sockets and tee's , clamps and supports on wall and grounds.
Material and Labour for for Copper piping 1 1/8" with necessary fitting such as elbow bends sockets and tee's , clamps and supports on wall and grounds or frame etc.
Material and Labour for for Copper piping 1/4" with necessary fitting such as elbow bends sockets and tee's , clamps and supports on wall and grounds.
Supply , laying,commissioning and testing XLPE insulated ,armoured heavy duty electric cable Aluminium conductor, 1100 volt cross sectional area 70 Sqmm 3.5 core incl removing unserviceable/old cable complete all as specified and as directed. Make: Polycab/Finolex /Paragaon/Havells
Supply , laying,commissioning and testing XLPE insulated ,armoured heavy duty electric cable Aluminium conductor, 1100 volt cross sectional area 35 Sqmm 3.5 core incl removing unserviceable/old cable complete all as specified and as directed. Make: Polycab/Finolex /Paragaon/Havells
Supply , laying,commissioning and testing XLPE insulated ,armoured heavy duty electric cable Aluminium conductor, 1100 volt cross sectional area 16 Sqmm 4 core incl removing unserviceable/old cable complete all as specified and as directed. Make: Polycab/Finolex /Paragaon/Havells
Supply , laying,commissioning and testing XLPE insulated ,armoured heavy duty electric cable Aluminium conductor, 1100 volt cross sectional area 6 Sqmm 3 core incl removing unserviceable/old cable complete all as specified and as directed. Make: Polycab/Finolex /Paragaon/Havells
Material and Labour for for disconnection/dismantling of electric motor 3 Phase, 415 Volt, from installation & transporting to workshop for rewinding , taking out old unserviceable burnt winding and rewinding the same with super enamelled copper wire 'H' Class of same size to get the same output of motor including material such as varnish, sleeves, leothariod paper etc and refixing the same in position with proper alignment, balancing and testing of capacities 7.5HP to 12.5 HP all as specified and directed.
Material and Labour for for disconnection/dismantling of electric motor 3 Phase, 415 Volt, from installation & transporting to workshop for rewinding , taking out old unserviceable burnt winding and rewinding the same with super enamelled copper wire 'H' Class of same size to get the same output of motor including material such as varnish, sleeves, leothariod paper etc and refixing the same in position with proper alignment, balancing and testing of capacities 15HP to 20 HP all as specified and directed.
Material and Labour for for disconnection/dismantling of electric motor 3 Phase, 415 Volt, from installation & transporting to workshop for rewinding , taking out old unserviceable burnt winding and rewinding the same with super enamelled copper wire 'H' Class of same size to get the same output of motor including material such as varnish, sleeves, leothariod paper etc and refixing the same in position with proper alignment, balancing and testing of capacities 30HP to 40 HP all as specified and directed.
Disconnection and taking out old defective Hermetically reciprocating sealed compressor unit as required of pakage AC plants and M&L for fixing new compressor (new sealed unit only) sealed unit by means of nut bolt & washer with antivibrating bush/ pad and brazing work, pressure testing for leakage, vacuumising etc of capacity 3 TR for pakage AC plants of the existing makes:-Voltas/Hitachi/ Carrier /copland/Emirson.
Disconnection and taking out old defective Hermetically reciprocating sealed compresso as required of pakage AC plants and M&L for fixing new compressor (new sealed unit only) sealed unit by means of nut bolt & washer with antivibrating bush/ pad and brazing work, pressure testing for leakage, vacuumising etc of capacity 5 TR for pakage AC plants of the existing makes:-Voltas/Hitachi/ Carrier /copland/Emirson.
Material and labour for fabrication and installation of Sign board made of Flex/Acrylic board, with computer imaging matter is directed by engr-in charge at one side of the board, GI plain sheet, cubicle housing, having arrangement to open the flex/Acrylic board and suitable for mounting on wall complete all as directed by engr-in-charge. Note :- The cost of Fabrication and welding work is included in the quoated rate.
Dismantling existing control & power wiring of LT starter Panel of Air conditioning plants capcity 10 TR to 60 TR & rewiring with PVC insulated copper wire existing size of control & power wiring for proper sequential working of contactors with delay timer, over load relay of compressor, water pumps, cooling tower motor,AHU motor, control mccb etc. by making proper connections to contactors, relays, fuses, switches, voltmeter,ammter incl Repair/ replacement of damaged hinges of each compartment of panel, taking down existing bus bars and cleaning with CTC applying with becktol red solution, providing bus bar insulation and refixing with new nuts, bolts, washers etc testing commissioning complete as directed. Note:- (i) Cost of electric cable, lugs & connectors is included in above cost. (ii) The quoted rate include the cost of painting of the panel with two coats of paints complete all as up to satisfection of Engr-in-charge. (iii) Cost of replacement of MCCB's, Contractor,s ,relay,s not included in the scope of work. (iv) Addition / Alteration/ Welding / fabrication work for fixing of new component is included in the quoted rate.
BRITE INDUSTRIES
BRILLIANT AIRCONDITIONING AND REFRIGERATION WORKS
M/s Vijay Airconditioning Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .