GE (AF) SIRSA
GE (AF) SIRSA
REPAIR AND CLEANING OF MONSOON DRAINS AND RECHARGE PITS AND REPAIR REPLACEMENT OF DTGM SIGN BOARDS AND RETRO REFLECTIVE TAPE MARKING AT AF STN SIRSA
2022_MES_550764_1
GE/SRA/T-34 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) SIRSA
As per Tender documents and NIT
3 documents required · 3 mandatory
₹500
GE (AF) SIRSA
₹40,000
Yes
12 Oct 2022
8 Sept 2022
8 Oct 2022
8 Sept 2022
6 Oct 2022
22 Sept 2022
8 Sept 2022 - 15 Sept 2022
Amount
Demolition of brick work of any description and built in cement mortar including all quoins, arches, pillers etc and complete all as specified and directed by Engineer-in-Charge.
M & L brick work with (old size) sub class B bricks straight or curved on plan exc 6 mtr mean radius and built in CM 1:4 and complete all as specified and directed by Engineer-in-Charge.
Ditto- all as per item No 3 here in before but except bricks and complete all as specified and directed by Engineer-in-Charge.
M&L for flush pointing to brick walls built in cement mortar 1:4 and complete all as specified and directed by Engineer-in-Charge
Raking out joints/pointing to brick walls built in cement mortar and complete all as specified and directed by Engineer-in-Charge.
Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and complete all as specified and directed by Engineer-in-Charge.
M & L 15 mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth with using extra cement and complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:2:4 type B1 (using 20mm graded stone agg) as in coping incl necessary form work and complete all as specified and directed by Engineer-in-Charge.
M&L for Cement Concrete type B2 1:3:6 (40 mm graded crushed stone aggregate as in surface channel and drains including demolition of cement concrete of any description and in any position not otherwise specifically provided for complete and all as per directed by Engineer-in-Charge.
Getting out/desilting of silt/soil along with roots of grass/bushes if any, from the beds of R/way/PTT side open drains, girth of drain bed not exceeding 1.50 m and depth of excavation of silt/soil upto drain bed level including removing excavated material exceeding 250 m but not exceeding 500 m from the sides of drain and spreading in low laying areas all as dirrected for depth of drain up to 1.5 m and complete all as specified and directed by Engineer-in-Charge
(ii) All as per item No. 10 here-in-before but depth of drain exceeding 1.5m to 3.0m and complete all as specified and directed by Engineer-in-Charge.
Getting out/desilting of silt/soil along with roots of grass/bushes if any from the beds of R/way/PTT side drains covered with RCC Drain Cover, girth of drain bed not exceeding 1.50 m and depth of excavation of silt/soil not exceeding 50 cm in depth including removing excavated material exceeding 250 m but not exceeding 500 mfrom the sides of drain and spreading in low iaying areas and complete all as specified and directed by Engineer-in-Charge for depth of drain up to 1.5 m Note : (a) Rate of Removing & re-fixing of RCC drain cover are included in the item as mentioned. (b) Hydra / Crane or any other arrangement shall be used for safely removal & refixing RCC Drain covers to avoid any damage to the drain and covers and the rates are also included in the item
All as per item No. 12 here-in-before but depth of covered drain exceeding 1.5m to 3.0m and complete all as specified and directed by Engineer-in-Charge
Getting out/desilting of silt/soil along with roots of grass/bushes if any from the beds of Recharge Pits, of any size of bed and depth of excavation of silt/soil not exceeding 100 cm in depth including removing excavated material exceeding 250 m but not exceeding 500 m from the sides of recharge pits and spreading in low iaying areas all as dirrected for depth of recharge pit/ manhole/ sump up to 1.5 m and complete all as specified and directed by Engineer-in-Charge.
Getting out/desilting of silt/soil along with roots of grass/bushes if any from the beds of Recharge Pits, of any size of bed and depth of excavation of silt/soil not exceeding 100 cm in depth including removing excavated material exceeding 250 m but not exceeding 500 m from the sides of recharge pits and spreading in low iaying areas all as dirrected for depth of recharge pit/ manhole/ sump exceeding 1.5 m to 3.0 m and complete all as specified and directed by Engineer-in-Charge.
S&F self adhesive reflective tape background including preparation of surfaces as taking down of existing self adhesive reflective tape background including alphabets / numbers / letters in DTGM / Cautionary boards / Sign boards complete all as specified and directed by Engr-in-Charge Note : Alphabets / Numbers / letters shall be measured and paid separately.
S&F self adhesive retro reflective tape including preparation of surfaces as existing tape for alphabets / numbers / letters in DTGM / Cautionary boards / Sign boards complete all as specified and directed by Engr-in-Charge Note : Qty shall be measured based on length/width and height of letters cut from a square/rectangular sheet.
M&L for replacement of existing sign board of size exc 0.36 Sqm and n. exc 0.81Sqm with following specifications or as directed by Engineer-in-Charge:- (a) Main frame for sign board shall be made of aluminium square / rectangular hollow section not less than 38.10mm x 38.10mm x 1.20mm incl supply & fixing of polycarbonate sheet of size exc 0.36Sqm and n. exc 0.81 Sqm both side of aluminium frame. (b) The height of bottom side of Board shall be minimum 300 mm above ground level or as per users requirement and the board shall be fixed minimum 300 mm below ground level with PCC 1:4:8, type D1, using 20 mm graded crushed stone aggregate. (c) The numbers/letters/digit/sign/lines/arrows, etc. made of retro reflective tape having reflective tape background shall be fixed over 2mm thick Polycarbonate sheet of approved colour. Note : Before procurement/ supply, sample of board shall be produced by the contractor for approval of GE.
M&L for replacement of existing sign board of size exc 0.81 Sqm and n. exc 1.50Sqm with following specifications or as directed by Engineer-in-Charge:- (a) Main frame for sign board shall be made of aluminium square / rectangular hollow section not less than 63.50m x 38.10mm x 1.2mm incl supply & fixing of polycarbonate sheet of size exc 0.81Sqm and n. exc 1.50 Sqm both side of aluminium frame. (b) The height of bottom side of Board shall be minimum 450 mm above ground level or as per users requirementand the board shall be fixed minimum 300 mm below ground level with PCC 1:4:8, type D1, using 20 mm graded crushed stone aggregate. (c) The numbers/letters/digit/sign/lines/arrows, etc. made of retro reflective tape having reflective tape background shall be fixed over 2mm thick Polycarbonate sheet of approved colour. Note : Before procurement/ supply, sample of board shall be produced by the contractor for approval of GE.
M&L for replacement of existing glow sign board of size exc 1.50Sqm and n. exc 3.00Sqm with following specifications or as directed by Engineer-in-Charge:- (a) Main frame for sign board shall be made of aluminium rectangular section (63.50 mm x 38.10 mm) incl supply & fixing of transparent perpex sheet of size exc 1.50Sqm and n. exc 3.00Sqm. (b) The height of bottom side of Board shall be minimum 450 mm above ground level and the board shall be fixed 30 cm below ground level with PCC 1:4:8, type D1, using 20 mm graded crushed stone aggregate. (c) The numbers/letters/digit/sign/lines/arrows, etc. made of retro reflective tape having reflective tape background shall be fixed over transparent perpex sheet not less than 3mm thick. (d) The board shall have suitable lighting arrangement (incl all light/ electrical fittings, bulbs, LEDs, etc alongwith min 15mtr long (from outside the board) suitable wire to give connection to light) to glow both sides of the board to see both side markings. (e) The gap between both sides of sheet shall not be less than 30 cm and the gap shall be covered with 1mm thick Aluminium sheet alround the aluminium frame. Note : Before procurement/ supply, sample of board shall be produced by the contractor for approval
M/s MANN CONSTRUCTIONS
AGGARWAL CONSTRUCTION CO.
M/s Satguru Traders
shiv shanker enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .