Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.1 LAccepted-AOC DEHRADUN | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹16.8 L+₹2.2 L (15.4%)Rejected-Finance OPP AIR FORCE STATION VPO SORANA DISTT SAHARANPUR UP PIN 247 232 | SAHARANPUR | UTTAR PRADESH | 247232 | L2 | Rejected-Finance Being 2nd lowest |
Tender Value
₹18.6 L
EMD Value
₹37,150
Closing Date
2 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MMD PRAVEEN NANDIKATTI GE AF SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
RENOVATION OF UNIT MANDIR AT NEW CAMP, PTS (VIKAS) UNDER GE (AF) SARSAWA
2024_MES_664509_2
8124/SAR-T-36/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE(AF) SARSAWA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (AF) SARSAWA
₹37,150
Yes
27 Jan 2025
11 Sept 2024
10 Oct 2024
11 Sept 2024
2 Oct 2024
18 Sept 2024
11 Sept 2024 - 18 Sept 2024
Amount
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Demolition of cement concrete (reinforced) in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engr-in-Charge
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr-in-Charge
Dismantling mild steel framed trusses n.exc. 10 m span complete all as specified and directed by Engr-in-Charge
Dismantling false ceiling (any type) incl insulation boards/slabs/blankets, any thickness, including cover fillets, grid & rod for false ceiling etc. complete all as specified and directed by Engr-in-Charge
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified.
M&L for Cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed by Engr-in-Charge
M&L for Reinforced cement concrete (Nominal Mix) Type B-1 1:2:4 (20mm graded aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engr-in-Charge. Note : Reinforcement shall be measured & paid separately under respective item.
M&L for Reinforced cement concrete (Nominal Mix) Type B-1 1:2:4 (20mm graded aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed by Engr-in-Charge. Note : Reinforcement shall be measured & paid separately under respective item.
M&L for Reinforced cement concrete (Nominal Mix) Type B-1 1:2:4 (20mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engr-in-Charge. Note : Reinforcement shall be measured & paid separately under respective item.
M&L for Reinforced cement concrete (Nominal Mix) Type B-1 1:2:4 (20mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr-in-Charge. Note : Reinforcement shall be measured & paid separately under respective item.
M&L for Reinforced cement concrete (Nominal Mix) Type B-1 1:2:4 (20mm graded aggregate) as in chajjas complete all as specified and directed by Engr-in-Charge. Note : Reinforcement shall be measured & paid separately under respective item.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished surfaces of concrete complete all as specified and directed.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finished surfaces of concrete complete all as specified and directed.
M&L for Formwork to Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. rough finished surfaces of concrete complete all as specified and directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished surfaces of concrete complete all as specified and directed.
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge.
M&L Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge.
M&L for Brickwork with old size subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St.-240 complete all as specified and directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe 410 -W (Gde- E- 250 quality-A) complete all as specified and directed.
M&L for Preparing new or previously untreated steel & iron surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (any colour) over & including a coat of red oxide primer complete.
M&L for false ceiling made out of E-board classic of size 600 x 600 x 4 mm thick, Gl frame consisting of main Tee of size 38.50 x 24.00 mm and cross Tee of size 28.50 x 24.00 mm thick made out of PGI sheet 0.30 mm thick doubled at web and single at flange, flange covered with poder coated sheet 0.25 mm thick and angle 24.00 x 24.00 x0.4 mm thick powder coated suspended with Gl wire 3 mm dia and up to 2 Mtrs long complete including, plugging fixing of angle to brick walls with steel rawl plugs @ 450 mm c/c and applying two coats of OBD to the ceiling board complete all as specified and as directed by Engineer-in-Charge
Dismantling floor hearth or wall tilling including cement mortar bedding ( but not backing) removing serviceable tiles to store & rubbish off the premises, complete all as specified.
M&L for Virified Ceramic tiles (light shade) 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over 15 mm thick cement screed bed in CM (1:6) complete all as specified.
M&L for Virified Ceramic tiles (light shade) 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in DADO/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over 10 mm thick cement screed bed in CM (1:4) complete all as specified.
Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete.
M&L rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete.
M & L for applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified.
M&L rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete.
M & L for Preparing new plastered or unplastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over a coat of 3mm thick wall care putty complete all as specified and directed.
M&L rendering 5 mm thick in cement mortar 1:3 on ceiling, finished even and smooth without using extra cement complete.
M & L for Preparing new plastered or unplastered surfaces of ceiling and applying two coats of distemper oil emulsion, white or tinted over a coat of 3mm thick wall care putty complete all as specified and directed.
M&L for hardcore, broken stone or boulders of gauge n. exc 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/ rammed to a true surface complete all as specified and directed by Engr-in-Charge
M&L for 100mm thick Cement concrete type D- 2, 1:4:8 (40mm graded aggregate) as in sub base complete as specified and directed.
M&L for 75mm thick Cement concrete type B- 2, 1:2:4 (40mm graded aggregate) as in sub base complete as specified and directed.
M&L for Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like over 20mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete as specified and directed.
M&L for Marble work (table rubbed and polished) for wall lining (veneering to wall) 25mm thick over 10mm thick cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade complete as specified and directed.
Taking down Chowkhats or frames with shutters (without taking off shutters from the frame) exc 1.5 sq. m but n exc 4 sq. m each complete as specified and directed.
M&L powder coated aluminium anodised three way track sliding windows of frame size 92 mm x 31.75 mm x 1.5mm thickness (section no. 20831 of JINDAL) and of shutter size 40 mm x 18 (with 9.00 mm interlocking legs) x 1.45 mm thick (section no. 20737 of JINDAL) section(two shutter glazed, covering half of span of opening each & one shutter sketlon covering half of span of opening ) incl provn for making windows air tight, including 95mm aluminium handle with spring lock , stainless steel wire cloth, 0.45 mm nominal dia of wire and average width of aperature 1.4mm and fixed with steel wire stapples and 5mm thick plain glass including necessary fitting/ fixture/ aluminium snap beads complete all as specified. Note: (i) Measurement shall be taken for clear opening i.e. out to out of window frame as a whole including all fittings and fixtures and no extra shall be paid separately. (ii) Glass & wire mesh (as applicable) is deemed to be included in the quoted rates and no extra measurement is required for the same.
M&L for PCC (1:2:4) TYPE B1 (using 20mm graded stone aggregate) as in coping and other similar bands incl weathering, slightly rounded or chamfered, angles and waste of form work throating as directed incl necessary form work complete all as specified and directed by Engr-in-Charge
S&F painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
S&F painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
M&L for Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) avg 40mm thick as in roof pedding , finished even and smooth without using extra cement ,including cleaning the concrete surface by steel wire brushes, up to three stories bldgs, complete .
M & L for APP polymeric water proofing membrane minimum 3 mm thick and wieghing not less than 3.0 Kg per Sqm , black finish reinforced with non woven polyester matt with a thermo fasable finish laid over bitumen primer @ 0.5Kg/Sqm by torching application with a propane or a butrane gas torch with an overlap of 100mm at the sides and 150 mm at the ends, as per manufacturers instructions and applying two coats of bituminous aluminium paint over membrane complete all as specified and directed by Engr-in-charge
M&L for applying two coats of bituminous aluminium paint over APP membrane complete all as specified and directed by Engr-in-charge.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed by Engr-in-charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25cm in soft / loose soil complete all as specified& directed by Engr-in-Charge.
Removal of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above or below the starting point complete all as specified & directed by Engr-in-Charge.
Taking down carefully copper / aluminium point wiring light / fan, socket or power point complete including fittings such as switches, sockets, ceiling rose, bell push bell buzzer lamp holder bracket etc. removing from site for taking credit and making good disturbed surface of wall, floor etc complete all as specified and as directed.
M & L for concealed point wiring complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit ISI marked medium grade not less than 20 mm dia, with MS stove enamelled sunken boxes (normal and modular type as required) including earth dolly with plastic laminated sheet top cover (cover plate with frame in case of modular) of approved make and colour including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and directed for the followings :- One light / fan point controlled by one way switch
All as per above item No-49 here in before but One 5 Amp socket outlet on independent board.
All as per above item No-53 here in before but One 5 Amp socket outlet on same board.
All as per above item No-53 here in before but One light point controlled by two 2-way switch
All as per above item No-53 here in before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
M&L for point wiring in stove enamelled steel conduit not less than 20 mm dia on surface of wall/ceiling floor etc complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade with including modular type PVC rectangular block of suitable size and plate and frame of modular type including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and as directed for the followings :- One light / fan point controlled by one way switch
All as per above item No-58 here in before but One 5 Amp socket outlet on independent board.
All as per above item No-58 here in before but One 5 Amp socket outlet on same board.
All as per above item No-58 here in before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
S&F of ceiling rose surface bakelite 63 x50mm three terminals complete all as specified and as directed.
S & F sub main wiring with PVC insulated, FRLS unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of 4.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) Two runs of 4.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor and conduit shall be a unit length.
S & F sub main wiring with PVC insulated, FRLS, unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 6.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of 6.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) Two runs of 6.0 sqmm cable and one run of 6.0 sqmm cable of earth continuity conductor and conduit shall be a unit length.
S&F in replacement of Double door distribution board 6 way TPN when MCB to be used as incomer powder coated with Bus Bar 200 Amps, 415 V, Earth Stud, Din Rail, complete all as specified and directed (Note- (a) MCBs are to be measured and paid seperately.
Supply and fixing modular type AC box 3 module operated with 20 Amp single pole MCB including 15 amp modular socket and plug top complete all as specified and directed by the Engr-in-charge. Make : - Legrand, Havells, Indo asian
S&F MCB SP 5 to 40 Amps, 240 volts curve 'B',breaking capacity 10KA, all as specified.
S&F MCB TPN 63 Amps, 240 volts, curve 'B', breaking capacity 10 KA, all as specified.
Supply and fixing Earthing to DBs with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 4.0 sqmm galvanised iron wire by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead shall be protected by GI pipe 15 mm dia medium grade and connected to distribution board including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and as directed.
M & L for Earth continuity conductor or main earthing lead of 4.0 Sqmm galvanized iron wire, buried in ground or fixed to wall in and including 15 mm bore GI pipe medium grade for protection of earth wire complete all as specified and directed.
S&F of enviroment friendly indoor decorative 20 Watt LED Polycarbonate Batten to provide light in three different colours cool white, Neutral white and warm whitewith the help of switch in same batten with opal diffuser , operating voltage range 140 v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤ 20 CRI>80 , inbuilt surge protection = 2.5 Kv, with zero mercury content including all accessaries all as specified and directed.
S&F of enviroment friendly indoor decorative 9/10 Watt LED polycarbonate with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed.
Supply and fixing of PVC round shape junction box cover of suitable size including fcomplete all as specified and as directed.
Supply & fix wall mounting fans 230 volts single phase oscillating 400 mm sweep suitable for wall mounting complete all as specified and as directed by Engr-in-Charge.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, 1400 RPM, blades, and frame and louver complete with making arrangement for fixing of exhaust fan on steel/Aluminium frame window/ making opening in brick wall as per site requirement and also making good to disturbed surfaces as per matching to existing complete all as specified and as directed by Engr-in-Charge.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed by Engr-in-Charge.
S&F in socket outlet 6A/16A-5 pin multipurpose combined 2 module modular type complete all as specified and directed.
S&F switch 16 amps modular type one module one way complete all as directed.
S&F in switch 6 amps modular type one module one way complete all as directed.
S&F in replacement socket outlet 6A- 5 Pin 2 module modular type complete all as specified and directed.
S & F in replacement of modular Fan Regulator fan step regulator,120W- single module ISI Marked complete all as specified as as directed.
S & F In replacement of modular switch 2 way, 6 Amp,1 module ISI Marked complete all as specified and as directed.
S&F of 24 watt LED strip type light in warm white colour or blue colour as decided departmnent including driver complete all as specified and directed.
M&L for taking down ceiling Fans/Exhaust fan and deposite to MES store yard complete all as specified and directed.
Taking Down LED fittings of any type any size compete all as specified and directed.
Taking Down MCB DB including MCB/MCCB of any type any size compete all as specified and directed.
S & F in replacement enviroment friendly recess/pendent mounting 36 watt LED flat panel 2'x2' fabricated CRCA sheet steel duly powder coated housing cool white with high efficient LEDs & glare free opal diffuser PF>0.95 , lumen efficacy>100 lm/W, THD<10% operating range 220v to 240V,CRI>80, colout temperature cool day light/Warm white as required including connection with existing wire and all accessaries all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 25 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide & not exc 1.5 mtr deep and getting out for taking out/laying cable, poles & stay etc complete all as specified and directed by engr-in-charge.
M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying ( total 23 cm ) and compaction till 18 cm thick for measurement purpose complete all as specified and directed .
Material labour for common burnt clay bricks, sub class 'B' grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified and as directed by Engr-in-Charge
Supply and install hi wall split Type Airconditioner with indoor & outdoor unit complete with Inverter Technology, 3D Airflow, power chill operation,cordless remote control unit and with in built air ioniser, PM 2.5 Filter for better indoor air quality with 5 star rating and EER 3.2 of capacity 2.0 TR with precharged CFC free refrigerant with hot and cold function all as specified and directed by Engr-in-Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed.
M&L for taking down Airconditioner of any type (spilt or window type) for depositing to MES store yard and refixing as per directed location including voltage stabilizer complete all as specified and directed.
SUBHASH CHAND CONTRACTOR (BID ID -3112462)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .