Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹19.9 LAccepted-AOC GALI NO 5 6 H NO 6 275 JHARODA MAARA EXTN PART III BURARI NEW DELHI 110084 | NEW DELHI | CENTRAL DELHI | DELHI | 110084 | 1 | Accepted-AOC Acceptance Of Tender | |
| 2 | 2₹22.0 L+₹1.9 L (9.24%)Rejected-Finance | 2 | Rejected-Finance Not L1 |
| Sl No | Description | Qty | Unit | QUALITY CONSTRUCTIONS CO L1 | Gaurav Enterprises L2 |
|---|---|---|---|---|---|
| 1.00 | B/R Items For Job No. LSA/DWP/08/SRW/2025-26 Taking down cement or cement lime plaster any description from brick or stone walls/ceiling etc including raking out joints, hacking for key & scrubbing down with water all as specified. | 1,330 | Sqm | 10 ₹13,300 Lowest | 20 ₹26,600 |
| 2.00 | M&L for rendering 15mm thick in CM 1:6 on brick work or concrete surface of wall and finished surface even and smooth without using extra cement all as specified and directed. | 900 | Sqm | 140 ₹1,26,000 Lowest | 169 ₹1,52,100 |
| 3.00 | M&L for rendering 15mm thick in CM 1:4 on brick work or concrete surface of wall and finished surface even and smooth without using extra cement all as specified and directed. | 400 | Sqm | 150 ₹60,000 Lowest | 190 ₹76,000 |
| 4.00 | M&L for rendering 10mm thick in CM 1:3 fair surface of ceiling finished surface even and smooth without using extra cement all as specified and directed. | 30 | Sqm | 150 ₹4,500 Lowest | 175 ₹5,250 |
| 5.00 | M&L for gunniting to RCC works in column beams, slabs, chajja, facia, landing, balconies etc by removing/ dismantling of RCC (loose concrete) and cutting of steel bar including plaster cleaning of surfaces with wire brushes and applying epoxy, paint anti corrosive coating of minimum 40-50 microns thick with sikatop Armatec 108 or Colusal VL of MC Bauchemie to rusted steel reinforcement after removing cleaning all rust and supply and fixing welded steel wire mesh 75mm x75mm with 4mm dia steel wire as facies/drops and similar works etc and expoxy based or other equivalent suitable bonding against treatment to be carried out on old concrete surface with Sikadur 32 of Sikka. Nito bond EP of fosroc or equivalent (as per manufacturers instruction) to bond old and new concrete mixing @ 2% by weight of cement polycrete and providing gunniting with a minimum pressure of 2 to 2.5 Kg sqcm and applying 25mm thick gunniting in cement mortar (1:2) (one part of cement and two part of ghaghar sand) using ordinary port land cement of 43 grade over wherever required, complete all as specified and directed by Engineer-in-Charge.
Note:-(i)After placing the additional reinforcement all concrete surface shall be thoroughly scrubbing with. (ii)Additional reinforced TMT bars where incorporated in work and including 20mm thick cement plaster in 1:4
(iii) Work to be carried out as in patches as directed by Engr-in-charge.
(iv) Rate for steel scaffolding as directed to be included in quoted rate.
(v) All demolished material removed from MOD land completely. | 30 | Sqm | 1,300 ₹39,000 | 1,200 ₹36,000 Lowest |
| 6.00 | M&L preparation of newly plastered surfaces and applying two coat of oil emulsion distemper (OBD) over 2 mm wall care putty & Primer on wall, approved shade/tint all as specified & as directed | 900 | Sqm | 60 ₹54,000 Lowest | 75 ₹67,500 |
| 7.00 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm | 400 | Sqm | 55 ₹22,000 Lowest | 90 ₹36,000 |
| 8.00 | M&L Prepration new/old plastered surfaces and applying two coat of white wash on ceiling all as specified. | 140 | Sqm | 10 ₹1,400 Lowest | 20 ₹2,800 |
| 9.00 | Removing existing roof treatment and preparing surfaces to the entire satisfaction of Engr-in Charge /GE including taking down existing plaster,cleaning of all foreign material such as grass roots dust etc and roughening the concrete surfaces by wire brushes and washing down to remove dust etc . flushing at junction of parapets complete and removing the same to the places complete all as specified and directed. | 110 | Sqm | 20 ₹2,200 Lowest | 35 ₹3,850 |
| 10.00 | Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for in this Schedule complete, all as specified. | 4.4 | Cum | 200 ₹880 Lowest | 350 ₹1,540 |
Tender Value
₹24.8 L
EMD Value
₹49,540
Closing Date
18 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE LUCKNOW
HQ CWE Lucknow, 229 MG Road, LucknowCantt, Lucknow-226002
SPL REPAIR TO BLDG NO P-25F AT 4 KB ROAD AND BATHROOM OF OR AT HQ DDGSI (CZ) UNDER GE (EAST) LUCKNOW.
2025_MES_731886_1
CWE/LKO/E/T-65 OF 2025-26
Open Tender
Civil Works
Item Rate
180 days
LUCKNOW
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
₹49,540
Yes
22 Jan 2026
20 Sept 2025
25 Oct 2025
20 Sept 2025
18 Oct 2025
4 Oct 2025
20 Sept 2025 - 4 Oct 2025
Amount
B/R Items For Job No. LSA/DWP/08/SRW/2025-26 Taking down cement or cement lime plaster any description from brick or stone walls/ceiling etc including raking out joints, hacking for key & scrubbing down with water all as specified.
M&L for rendering 15mm thick in CM 1:6 on brick work or concrete surface of wall and finished surface even and smooth without using extra cement all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on brick work or concrete surface of wall and finished surface even and smooth without using extra cement all as specified and directed.
M&L for rendering 10mm thick in CM 1:3 fair surface of ceiling finished surface even and smooth without using extra cement all as specified and directed.
M&L for gunniting to RCC works in column beams, slabs, chajja, facia, landing, balconies etc by removing/ dismantling of RCC (loose concrete) and cutting of steel bar including plaster cleaning of surfaces with wire brushes and applying epoxy, paint anti corrosive coating of minimum 40-50 microns thick with sikatop Armatec 108 or Colusal VL of MC Bauchemie to rusted steel reinforcement after removing cleaning all rust and supply and fixing welded steel wire mesh 75mm x75mm with 4mm dia steel wire as facies/drops and similar works etc and expoxy based or other equivalent suitable bonding against treatment to be carried out on old concrete surface with Sikadur 32 of Sikka. Nito bond EP of fosroc or equivalent (as per manufacturers instruction) to bond old and new concrete mixing @ 2% by weight of cement polycrete and providing gunniting with a minimum pressure of 2 to 2.5 Kg sqcm and applying 25mm thick gunniting in cement mortar (1:2) (one part of cement and two part of ghaghar sand) using ordinary port land cement of 43 grade over wherever required, complete all as specified and directed by Engineer-in-Charge. Note:-(i)After placing the additional reinforcement all concrete surface shall be thoroughly scrubbing with. (ii)Additional reinforced TMT bars where incorporated in work and including 20mm thick cement plaster in 1:4 (iii) Work to be carried out as in patches as directed by Engr-in-charge. (iv) Rate for steel scaffolding as directed to be included in quoted rate. (v) All demolished material removed from MOD land completely.
M&L preparation of newly plastered surfaces and applying two coat of oil emulsion distemper (OBD) over 2 mm wall care putty & Primer on wall, approved shade/tint all as specified & as directed
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm
M&L Prepration new/old plastered surfaces and applying two coat of white wash on ceiling all as specified.
Removing existing roof treatment and preparing surfaces to the entire satisfaction of Engr-in Charge /GE including taking down existing plaster,cleaning of all foreign material such as grass roots dust etc and roughening the concrete surfaces by wire brushes and washing down to remove dust etc . flushing at junction of parapets complete and removing the same to the places complete all as specified and directed.
Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for in this Schedule complete, all as specified.
M&L cement concrete type B-1, 1:2:4 (20mm graded aggregate) on roof slab all as specified and directed.
Rendering 10mm thick on fair faces of concrete surfaces in cement mortar 1:4, mixed with liquid water proofing compound finished even and smooth without using extra cement . (Liquid water proofing compound to be measured paid separately) complete all as specified and directed.
Supply only Liquid water proofing compound complete all as spesified and directed.
M&L for application of high perfomance hybride polyurea elastomeric water proofing coating cold applied, liquid membrane at 1.5 kg/Sqm with an elongation minimum of 500+100% by airless spray machine and tensile strength of minimum 11-13 N/mm2 as per ASTM D2370, crack bridging ability minimum of 3 to 4 mm as per ASTM C1305 , Shore Hardness of minimum 70+5 as per ASTM D2240 complete as per directed by Engr-In-Charge. The System shall also include final base preparation including cleaning of the plaster surface etc and applying epoxy primer as approved makes in two coats at a coverage of 0.40 kg/Sqm, etc as per manufacturer specification, complete all as specified and directed. Note:- (a) The work petaining to water proofing treatment shall be executed for authorized applicator through manufacture of wich the materials is proposed to be used by the contrator and approved by Garrision Engingeer.
M&L for cement concrete 1:3:6 type C2, 75 mm thick as in plinth protection and flooring and finishing the surface even and smooth without using extra cement.
Demolition of reinforced cement concrete as in self etc (reinforcement cut as reqiured to faciliate demolition) complete all as specified and directed.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) and area n.exc 1.5 Sqm each all as specified.
S&F for in repair three layer rotational moulded polyethylene water storage tank cylindrical hoisted & fixed in position incl dismantiling water tank complete all as specifed capacity 1000 ltrs.
S&F in repair 20 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod and high density Plastic ball Screwed for iron pipe and fixed (Minimum weight -210 gms.
S&F 15 mm bore GI tubing medium grade with all fittings and fixed complete to wall and ceiling or laid in floors including taking down
S&F 20 mm bore GI tubing medium grade with all fittings and fixed complete to wall and ceiling or laid in floors including taking down
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, all as specified and directed
S&F vitrified tiles dark/light shade digital tiles/(double charged), 8 mm thick (square/ rectanglar) polished , exceeding 0.18 sqm of each tiles not exceeding 0.38 sqm, in floors etc. laid over 15mm thick screed bed 1:6 , set and jointed in neat cement slurry and pointed in white/coloured cement to match complete all as specified.
M&L Glazed ceramic tiles (coloured) in vertical surfaces 600x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to matchover 10mm thick rendering in cement mortar 1:3 complete all as specified and directed.
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
S&F 65x100 mm single rebated factory made 100% solid WPC (Wood Polymer Composit) door frame from 100% lead free ( Single & extruded process) material with dencity not less then 780kg /Cum all as specified and directed
S&F 65x125 mm double rebated factory made 100% solid WPC (Wood Polymer Composit) door frame from 100% lead free ( Single & extruded process) material with dencity not less then 780kg /Cum all as specified and directed.
S&F 30mm thick factory made solid WPC (Wood plastic composit) moulded glzed door shuter with wire mesh in any number of division with brown wood grain texture including SS wire mesh (G-304) 0.36 mm minimum dia of wire and average width of aperature 1.4mm shall to be fixed with 15x15 square tube in side rails with screwing 8x28 heat metel zink coated screws can be remove of fix again after changing of wire mesh needed. The density shall be as per manufacture instruction complete all as specified and as directed
S&F for XPM Aluminium alloy wire cloth of wire all as specified and directed.
S&F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
S&F 4.8mm thick sheet glass ordinary quality and glazing with oil putty/Aluminium beads in square exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces ground or obsecured to one side complete all as specified.
Providing & fixing of vajra series windows made of pre-painted steel (Base steel as per IS 513 of 0.58mm thick “D” Quality galvanized as per IS 277 with zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 72x55mm, centre mullion should be of 72x50mm, section for fixed glass beading should be of 12x12mm and section for shutter should be of 52 x 25mm. Outer frame & mullion sections to have rebate for glazed shutters, fly mesh and 20 mm provision for guard bars/ grills fly mesh shutter section should be of 20x40mm. The sections are to be cut to length mitre joined with corner bracket. Centre mullions to be fixed with mullion cap. Elixir or equivalent stay, handles 2nos of heavy-duty stain less steel pivot hinges shall be provided per shutter. The windows should be panelled with 4 mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade). Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self-expanding, screws. Including 10mm square guard bars with 6” (152.4mm) pitch, complete for finished item of work including of all taxes. (Make: Elixir Met Form Pvt Ltd or equivalent or as approved by concerned GE
S&F 250 mm long stainless steel sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolts all as specified
S&F for stainless steel barrel tower bolts 200 mm of extruded section and fixed.
S&F for stainless steel barrel tower bolts 150 mm of extruded section and fixed.
S&F 150 mm size stainless steel handles fabricated type extruded section ,ISI marked all as specified
S&F Butt hinges 125 mm stainless steel hinges medium weight and fixed
S&F Butt hinges 100 mm extruded stainless steel steel hinges pin anodised type B-21 and fixed to PVC frame
S & F Vitreous china Squatting pan, indian pattern, size 580 x 440mm white, with integral foot rest in cluding 'P' or 'S' trap complete, fixed in repairs
S&F 10 Litres capacity PVC valveless syphonic action type flushing cistern low level, white with inlet ball valve float and handle including brackets connection to pipes and fixing of lever if any joint between flushing pipe and socket of WC pan pre-made Make : Parry ware/Slimline/ Cera
S&F 110mm PVC (SWR) junction single (single T) equal or unequal
S&F in repair 75mm bore PVC (SWR) pipe single socketed in any length with rubber rings joints laid in trenches or in floor/wall all as specified and directed by Engineer-in-charge.
S&F 110mm bore PVC (SWR) bends, any radius.
S&F PVC (SWR) bends any radius of 75 mm dia all as specified.
S&F 15mm dia fancy type chromium plated bib taps cast copper alloy with crutch or butterfly handle, scresed down screwed for iron pipe or for brass ferrule and fixed both ends for iron pipe or for unions
S&F in repair 15 mm dia Pillar tap cast copper alloy chromium plated fancy type with capstan head and cup screwed down screwed for G I pipe or for brass ferrule all as specified.
S&F 15mm dia fancy type chromium plated angle valve/cast copper ally screwed down, high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed to GI Pipe.
S&F CP brass towel rails 20 mm dia and 600 mm long fixed as in repair incl chromium plated brass screw and wooden / cleats
S&F PVC connection of 15 mm bore 600 mm long with brass coupling on both ends of superior quality all as specified.PTMT nuts fixed as in repair.
S&F in repairs 32 mm dia Waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm 45gms/40mm-60 gms)
S&F in repairs 32mm dia PVC waste pipe approx 900mm long for sink/WHB complete all as specified.
S&F stainless steel drapery curtain rods standard quality dia not less than 25mm with fancy type stainless steel latoo at both ends and Stainless Steel Bracket for middle support as required all as specified and direced as approved by GE.
B/R Items for Job No. DDGSI/DWP/01/SRW/2025-26 S&F powder coated Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified
S&F butt hinges of size 100 mm medium weight, cold rolled stainles steel ISI marked complete all as specified and directed.
S&F 150 mm size aluminium alloy handles, fabricated type, extruded section.
M&L for aluminium sliding door bolt of lenghth 200mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
S&F 200 mm long aluminium anodised barrel tower bolts of extruded section all as specified.
M&L brick work with sub class B bricks, straight or curved on plan any radius half brick thick wall, built in cement mortar 1:4
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc, all as directed.
M&L for 10mm thick rendering in CM 1:6 on brick or concrete surfaces on wall and finished surface even and smooth witout using extra cement all as specified and directed
M & L rendering 15mm thick on brick work in CM 1:4 finished even and smooth without using extra cement
M&L for applying two coats of oil emulsion paint(OBD) over a coat of primer on new / old plastered surface of wall including preparation of surfaces,complete all as specified and directed
M&L preparation of newly plastered surfaces and applying two coats of cement base paint
Taking down 15mm dia GI tubing and connections incl. cleaning for refixing or removal to store complete all as specified and as directed.
Taking down 20mm dia GI tubing and connections incl. cleaning for refixing or removal to store complete all as specified and as directed.
Cutting chases, pining in, making good to facings where required and pointing in CM 1:3 for concealed water tubing and making good, cutting exc 10cm but n.exc 20cm girth in brick walls all as specified.
S&F of 15 mm bore steel tube, medium grade, galvanised with all fittings such as bends, elbows, tee etc and fixed to walls and ceiling complete all as specified and directed.
S&F of 20 mm bore steel tube, medium grade, galvanised with all fittings such as bends, elbows, tee etc and fixed to walls and ceiling complete all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding ( but not backing ) removing serviceable tiles to store yard complete all as specified and directed by Engineer-in-Charge.
M&L for non Skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm , in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match including 15 mm thick rendering in CM 1:4 complete all as specified and directed.
S&F glazed coloured ceramic digital tiles 600x300x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick rendering in CM 1:4 as in vertical surfaces as approved.
M&L in repair PVC floor trap 75mm with grating incl jointing to waste pipe fixed in cement concrete type B1 ,1:2:4,all as specified and directed.
M&L in repair PVC floor trap 100 mm with grating incl jointing to waste pipe fixed in cement concrete type B1 , 1:2:4 ,all as specified and directed.
S&F in repairs PVC (SWR) pipes 75 mm dia bore single socketed, in any length with rubber ring joints laid in trenches or in floors
S&F in repair 75 mm UPVC (SWR) bends any radius,make:- Supreme or equivalent
S&F in repair 100 mm Traps ‘P’ or ‘S’
S&F in repair for Vitreous china squatting pan Orissa pattern size 580x440 mm white with P or S trap front or back inlet with integral foot rests (excluding flushing cistern and flush pipe ) complete
S & F in repair vitreous china wash down water closet pan (pedestal pattern) white (excluding flushing cistern and flush pipe) including connection to drain or out going pipe and flush pipe anti syphonage pipe etc complete all as specified and as directed.
S&F in repairs Plastic water closet seat cover coloured/white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device all as specified and directed.
S&F in repair vitreous China Urina half Stall type(back or corner wall type) size of 465x355x265mm white,complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinalto plugs with and including 60 mm long brass screws, pointing around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe gratings and urinal for discharge pipe etc all as per directed.
S&F in repair soap dish of fancy type all as specified.
S&F glass self/corner self assembly consisting of 5.5 mm thick glass sheet glass self 12 Cm wide with CP bracket gaurd and railing 60 Cm long all as specified.
S&F in repair bib tap 15mm dia long body,chromium plated, fancy type all as specified.
S&F in repair brass CP tubular towel rail of superior quality 20mm dia 60cm long between flanges fancy type all as specified.
S&F in repairs PVC connection of 15mm bore,600mm long with brass coupling on both ends of superior quality all as specified.
S&F in repair CP angle valve for 15 mm bore pipe with capstan head long screwed shank including cp cover plate fancy type fixed as in repair.
S&F in repair 15 mm dia Pillar tap cast copper alloy chromium plated fancy type with capstan head and cup screwed down screwed for G I pipe or for brass ferrule all as specified.
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
S&F in repair 15mm dia CP two way tap consisting angle valve to control water suitable for jet cleaner all as specified.
E/M Items for JOB NO. LSA/DWP/SRW/08/2025-26 Supply and fix in replacement of integrated LED bulk head fitting 10 Watt, 100 lm/wat ,6500K with IP 65 &ik-08 protection comprises of polycarbonate cover, etc complete all as specified and directed.
Supply and fix in rep[air of MCB DB TPN 8 way 230 volts, double door type with minimum capacity of 200 Amps rated bus bar including necessary dummy plate and necessary civil works all as specified and directed.
Supply and fix in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN),double door, AC, 440 volt, 04 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed and comprising of the following:- (a) MCCB, 125 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. Make:- Havells/L&T/ABB/Sechinder/Indo-Asian (b) MCB, SPN, AC, 240 volt of 40 Amp, "C" curve, 10 KA breaking capacity - 08 Nos.
Supply and fix MCB SP 230V, 6-32 Amps capacity all as specified and directed.
Supply and fix MCB SPN 230V, 6-32 Amps capacity all as specified and directed.
Supply and fix MCB TPN 415V, 32 to 63 Amp capacity all as specified and directed.
Material and Labour for Submain wiring with 2 runs of FRLS grade PVC copper conductor cable 6 sqmm, multistranded along with FRLS grade PVC insulated copper earth continuity conductor 6 Sqmm drawn through and including PVC Conduit pipe 20 mm dia with all fittings all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 3.5 core all as specified and as directed by the Engr-in-Charge.
Supply & fix HDPE pipe DWC grade 80mm bore in trench/ wall/floor for protection of Cable including making good of the distubed surface all as specified and directed.
Supply and fix single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one 20amps SPN MCB all as specified and directed
M&L for laying 6 sqmm two core aluminium cable incl 25mm dia PVC Conduit and all other connected items all as specified and directed by Eng-in-Charge.
Supply and fixing storage water heater (Geyser) of capacity 50 ltrs, 230 volts, power consumtion 230V, vertical type, Rated pressure 5.6 bar pressure rating more than 8 bar suitable for high rise buildings,rust and shock proof ABS Outer body for lomg life,Stainless steel inner tank of 304 grade,65 MPa bar pressure,automatic shut off including four nos of rag bolts and making the elctrical / water supply connection including testing after installation complete all as specified and directed by Engr-in-Charge.
Supply and fixing ceiling fans ( COPPER WINDING) complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as specified and directed. Note:- Down rods of suitable length( 4feet,5 feet or 6 feet) is incl in the item rates and no extra payment will be done to the contractor for the same.
Supply and fixing steel body Exoust fan 300 mm sweep AC single phase, 230/240 volts 50 Hz with louvers and making connection from ceiling rose with twisted copper flexible wire 23/0.076 mm incl cutting of holes and matching with the surface after finishing all as specified and directed.
Cutting chases in concrete wall/stone for laying PVC conduit and making good to facings where required and pointing in cement mortar 1:3, and making good, cutting not exc 20 cm girth.
E/M ITEMS FOR JOB NO. DDGSI/DWP/01/SRW/2025-26Supply and fix Modular switch one way 16A 230V AC 50 HZ SP one module all as specified.
Supply and fix Modular socket 2/3 pin combined 6A 230V AC 50 HZ SP two module all as specified.
Supply and fix Modular socket 6A/16A 2/3 pin combined 230V AC 50 HZ SP two module all as specified.
Supply and fix PVC Ceiling rose all as specified.
Supply and fixing of wall/surface mounted integrated batten LED light luminaire of 4ft length with a system wattage of 20-22W with a nominal system lumen output of 2000-2200 lumens and a minimum system efficacy of 100Lm/W. CCT shall be 6500K and CRI ≥ 80. Housing shall be extruded aluminimum with powder coating & with IP20 protection, The luminaire shall meet IP20 rating with surge protection of 2.5KVA, THD ≤10% and PF ≥ 0.95,
Supply and fix spot/Display/picture light with adjustable head and colour changing fucntion 12W all as per directed.
Supply and fix 45W Pressure die cast aluminium housing street light with system lumen of 6300 lm and system efficacy of 140 lm/w, IP-66,IK-10 single piece die cast incl spigot, dia 48-76mm,LED lifetime (L70B50) 75k Hrs with integrated optical cover. Street light should have standalone lighting control system with AUTO ON/OFF based on DUSK/DAWN timings,preset time settings with monthly variations (Jan to Dec), inbuilt real time clock for switching, incleds dimming profile for energy savings,drift not exceedind max 2mins/year, clock retention upto five yeras, auto switching off secondary power for module,dimmable driver based on PWM control, dim to off with high/low voltage cut off with 440V protection for 8 hrs for complete luminiarie incl driver and astro module,surge protection as perIEC 61000-4-5 incl MS Clamps and bracket of 40mm dia and farsnut for fixing the light all as specified and directed by engineer in charge. Make- Philips Model No- UrbanedgeD2DBR501 or Eqv to Havells/Bajaj
Supply and fix in rep[air of MCB DB SPN 8 way 230 volts, double door type with minimum capacity of 200 Amps rated bus bar including necessary dummy plate and necessary civil works all as specified and directed.
Supply and fix MCB SP 230V, 6-32 Amps capacity all as specified and directed.
Supply and fix MCB SPN 230V, 63 Amps capacity all as specified and directed.
Supply and fix single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one 20amps SPN MCB all as specified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core all as specified and as directed by the Engr-in-Charge.
Supply and fixing PVC Airfreshner 250 mm sweep AC single phase, 230/240 volts 50 Hz with louvers and making connection from ceiling rose with twisted copper flexible wire 23/0.076 mm all as specified and directed. Make:- Bajaj/Havells/Crompton/Usha
Common B/R items for both the Jobs Taking down chowkhat or frame with shutter (without taking off shutter from the frame) and area exc 1.5 Sqm but n.exc 4 sqm each all as specified.
S&F 75x50mm single rebated factory made 100% solid WPC (Wood Polymer Composit) door frame from 100% lead free ( Single & extruded process) material with dencity not less then 780kg /Cum all as specified and directed.
S&F Factory made 30 mm thick 100% solid WPC (Wood Polymer Composite) solid both side 14 micron Flush door shutter wit 10mm deep CNC moulding design of required size comprising of virgin PVC resin of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately)
S&F in repair 110mm bore PVC (SWR) pipe single socketed in any length with rubber rings joints laid in trenches or wall including down all as specified and directed.
S&F PVC (SWR) 75mm floor trap, plain with grating including jointing with solvent cement
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete .
M&L for brick work with sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius built in cm 1:6
S&F in repairs vitreous china wash hand basin, white, flat back of size 550x400mm with & including a pair of cast iron brackets embedded in PCC 1:3:6 type C1 blocks of size 10x7.5x15cm, 32 mm dia PVC waste pipe and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified.
Common E/M Items for both Jobs Taking down carefully copper/aluminium point wiring ( light, fan, socket , bell or power) complete including all electrical fittings & fixtures all as specified and directed by Engineer-in-charge.
Taking down carefully Submain wiring any size complete including all electrical fittings & fixtures etc all as specified and directed by Engineer-in-charge.
Taking down carefully Ceiling fan/wall fan/Ex fan any size complete and handing over to Yard-I OR taking credit including all (electrical fittings & fixtures etc) all as specified and directed by Engineer-in-charge.
Material and Labour for point wiring complete with 1.5 sqmm (nominal area) FRLS grade PVC insulated, unsheathed multi stranded copper conductor single core cable 1100 volts grade in and including PVC conduit with accessories including 1.5 sqmm FRLS grade PVC insulated unsheathed stranded copper conductor cable for earth continuity conductor and connected to common earth dolly for One light/Ex-fan point controlled by one switch 5Amps SP all as specified and directed. Note :- Sunken box/cover plate for modular switches, sockets etc will be measured and paid seperately under relevant items and blank plate required if any will be deemed included in the item rate.and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall all as specified.
All as per Item No 130 hereinbefore but for One 5 A socket outlet on same Board all as specified and directed.
All as per Item No 130 hereinbefore but point wiring complete with 2.5 sqmm for 3 pin 5 Amp and 15 A socket outlet on independent board including 2.5 sqmm FRLS grade PVC insulated unsheathed stranded copper conductor cable for earth continuity conductor all as specified and directed.
Material and Labour for Submain wiring with 2 runs of FRLS grade PVC copper conductor cable 4 sqmm, multistranded along with FRLS grade PVC insulated copper earth continuity conductor 4 Sqmm drawn through & including PVC Conduit pipe 20 mm dia with all fittings all as specified and directed.
Supply and fix frame plate with match cover three module all as specified and directed.
All as per item No.134 above but six module all as specified and directed.
All as per item No.135 above but eight module all as specified and directed.
Supply and fix terminal box suitable three modular plat of size 100X75x50 mm including cutting, grooving and plastering etc. all as specified and directed.
All as item No 137 above but six modular plat of size 210X75x50 mm including cutting, grooving and plastering etc. all as specified and directed.
All as item No 137 above but eight modular plat of including cutting, grooving and plastering etc. all as specified and directed.
Supply and fix Modular switch one way 6A 230V AC 50 HZ SP one module all as specified.
Supply and fix Modular switch one way 16A 230V AC 50 HZ SP one module all as specified.
Supply and fix Modular socket 2/3 pin combined 6A 230V AC 50 HZ SP two module all as specified.
Supply and fix Modular socket 6A/16A 2/3 pin combined 230V AC 50 HZ SP two module all as specified.
Supply and fix Modular Regulator 230V AC 50 HZ SP two module all as specified.
Supply and fix PVC Ceiling rose all as specified.
Supply and fixing of wall/surface mounted integrated batten LED light luminaire of 4ft length with a system wattage of 20-22W with a nominal system lumen output of 2000-2200 lumens and a minimum system efficacy of 100Lm/W. CCT shall be 6500K and CRI ≥ 80. Housing shall be extruded aluminimum with powder coating & with IP20 protection, The luminaire shall meet IP20 rating with surge protection of 2.5KVA, THD ≤10% and PF ≥ 0.95,
Supply and fix wall spot/Display/picture light with adjustable head and colour changing fucntion 10-12W all as per directed.
Supply and fix 45W Pressure die cast aluminium housing street light with system lumen of 6300 lm and system efficacy of 140 lm/w, IP-66,IK-10 single piece die cast incl spigot, dia 48-76mm,LED lifetime (L70B50) 75k Hrs with integrated optical cover. Street light should have standalone lighting control system with AUTO ON/OFF based on DUSK/DAWN timings,preset time settings with monthly variations (Jan to Dec), inbuilt real time clock for switching, incleds dimming profile for energy savings,drift not exceedind max 2mins/year, clock retention upto five yeras, auto switching off secondary power for module,dimmable driver based on PWM control, dim to off with high/low voltage cut off with 440V protection for 8 hrs for complete luminiarie incl driver and astro module,surge protection as perIEC 61000-4-5 all as specified and directed by engineer in charge.
Supply and fix in rep[air of MCB DB SPN 8 way 230 volts, double door type with minimum capacity of 200 Amps rated bus bar including necessary dummy plate and necessary civil works all as specified and directed.
M &L for Excavation in trenches not exc 1.5 m wide and not exc 1.5m deep for laying of pipe, cable etc and getting out in soft/loose complete all as specified and directed.
M&L for Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and directed.
M &L for Removing surplus excavated material to a distance not exc 50 meter and depositing where directed at level not exc 1.5m above the starting point complete all as specified and directed.
M&L for sand cushioning for protection of cables complete all as specified and directed.
Supplying & laying common bricks sub class B for LT cable for protection of cable complete all as specified and directed.
Material and labour Earthing complete with galvanized steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized earth wire of size 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 connected to earth testing point including necessary excavation, earth work, PCC pit ,RCC cover 1:2:4 B1 with 8 mm dia MS rounds 1.5 kgs, funnel ,watering pipe etc. all specified and directed including testing on completion.
Gaurav Enterprises (BID ID -3453779)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.10 MB
Tenderet65.pdf
Tender Documents • 1.33 MB
BOQ_819414.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .