Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹62,100
Closing Date
15 Jun 2026, 2:00 pmClosed
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
72 days
Expenditure
Capital (Works)
12 conditions · 1 needing a document upload
Partnership firm/Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. Please submit a certificate in the prescribed format (please download the format from the link given below). Non submission of the certificate, or submission of certificate either not properly filled in, or in a format other than the prescribed format shall lead to summary rejection of your offer. (Click here to download the Format of Self Certification)
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
61 conditions · 17 needing a document upload
Whether the List of works on hand indicating description of work, contract value and approximate value of balance work yet to be done and date of award, has been uploaded?
Whether the List of plant and machinery available on hand (Own) and proposed to be inducted (Own and hired) for the subject work, has been uploaded?
Whether the documents related to particulars of technical staff to be employed on the work has been uploaded?
Whether the documents related to sole proprietorship, Partnership firm, Company/Co- operative society etc. has been uploaded?
COMPLETION TIME: The work must be completed within 6 months from the date of issue of acceptance letter. The contractor shall state clearly at the earliest possible time in which they can commence, complete the work and handing over to the Railway administration. The period stipulated by the contractor shall not under any circumstances be altered subsequently. Delay in booking, materials or making arrangements for accommodation of staff and materials shall not be an excuse for delay in executing the contract.
Tenderer should submit the Bank details such as Name of the Bank along with Bank Branch code, account No., IFSC Code and PAN Number etc.
Other points, in details, are furnished in the Document Section.
All the bidders/tenders should ensure that they are GST complaint and their quoted tax structure/rates are as per GST Law.(Please upload certificate of GSTIN registration).
Please Submit your bank details.
The Authority reserves the right of declining / accepting the Tender or re-tendering without assigning any reason.
RELEASED MATERIALS: The released materials if any must be deposited with proper challan and proper documents.
Electric Contractor License: The contractor shall fulfill valid Electrical Contractor License requirement as per IE Rule 1956 clause no-45 along with Electrical Supervisory License. The same shall be submitted along with the offer, failing which the offer will summarily rejected.
INSPECTION AND ACCEPTANCE: Materials shall be offered for inspection to the authorized representative of Dy. CEE (W)/E. Rly./LLH (for Scheduled Item Sl. No. 1 to 20 and 22 to 32) and RITES / TPI (for Scheduled Item Sl. No. 21) on his written acceptance the same are to be fitted at site. The cost of inspection charges shall be borne by the contractor.
Bid Security deposited by the successful tenderer will be forfeited if the tenderer shows resiliencies form his/her/their offer or modify the terms and condition thereof in a manner not acceptable to the Railway within the stipulated period of validity of offer. If the successful tenderer fails to execute the agreement bond/security deposit or start the work within the stipulated period, or as may be stipulated in the letter of acceptance, the entire earnest money shall be liable to be forfeited to the Rlys. Earnest money is liable to be forfeited in cases where any of the statements/declarations/information made by the tenderer is proved wrong/false/incomplete or such as to withhold any information relevant for consideration of the tenderer.
The amount of Bid Security will be refunded to the un-successful tenders after finalization of the tender. The earnest money remitted by the successful tenderer, will be refunded on deposition of full security money of the contract or may be adjusted against security deposit.
As per provision of IR GCC, 2022; the Bid Security shall be deposited either in cash through e payment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure-VIA and shall be valid for a period of 90 days beyond the bid validity period. In case, submission of Bid Security in the form of Bank Guarantee, following shall be ensured: (i) A scanned copy of the Bank Guarantee shall be uploaded on e-Procurement Portal (IREPS) while applying to the tender. (ii) The original Bank Guarantee should be delivered in person to the official nominated as indicated in the tender document within 5 working days of deadline of submission of bids. (iii) Non submission of scanned copy of Bank Guarantee with the bid on e- tendering portal (IREPS) and/or non submission of original Bank Guarantee within the specified period shall lead to summary rejection of bid. (iv) The Tender Security shall remain valid for a period of 90 days beyond the validity period for the Tender. (v) The details of the BG, physically submitted should match with the details available in the scanned copy and the data entered during bid submission time, failing which the bid will be rejected. (vi)The Bank Guarantee shall be placed in an envelope, which shall be sealed. The envelope shall clearly bear the identification "Bid for the ***** Project* and shall clearly indicate the name and address of the Bidder. In addition, the Bid Due Date should be indicated on the right hand top corner of the envelope. (vii) The envelope shall be addressed to the officer and address as mentioned in the tender document. (viii) If the envelope is not sealed and marked as instructed above, the Authority assumes no responsibility for the misplacement or premature opening of the contents of the Bid submitted and consequent losses, if any, suffered by the Bidder.
While processing payment of any 'On Account Bill' or 'Final Bill' or release of 'Advances' or 'Performance Guarantee/ Security Deposit' etc. contractor has to submit a certificate regarding uploading/updation of the correct details of contract labours engaged in connection with the subject contract and payments made during the wage period in Railway's Shramikkalyan portal at ''www.shramikkalyan.indianrailways.gov.in'' till........Month..........Year............
Police Verification of Antecedents of Contractual Staff through online mode as per Sr. DSC /RPF/ER/HWH's letter No. HWH/Contractual Labour/2024 dt. 26.11.2024 (Letter uploaded in Document Section).
TERMS OF PAYMENT: Subject to any deduction or recoveries which the Railway Administration may be entitled to make under the contract, the contractor shall unless otherwise agreed to be entitled to get the payments according to condition stipulated below: (i) Payment against the work shall be made in 03 (Three) spells against satisfactory completion of the work duly certified by the competent authority. (ii) The Contractor will have to submit bills in triplicate along with the actual work done certificate/ Joint witnessing certificate by firm's representative and the supervisor-in- charge of the work. (iii) The Rly. at their discretion may make payment to the contractor through ECS/ NEFT.
Commencement of Works: As per GCC 2022 Clause no. 19.(2), The Contractor shall commence the works within 15 days after received the LOA and shall proceed with the same with due expedition and without delay.
Penalty - The Railway reserves the right to deduct following penalty for non-compliance of terms and condition of this contract. i) In case the contractor fails to commence the work at any worksite within 15 days after receipt of Letter of Acceptance, a penalty of Rs.1000/- per day will be levied. However, if railway has asked for late commencement of work due to administrative reasons, then no penalty will be levied. ii) If the scrap materials are not disposed properly to an identified location (nominated dustbin), a penalty of Rs.1000/- will be levied per occasion. iii) Exemption of penalty can be considered by the competent authority on special cases such as natural calamity, bad weather or any valid reason etc. The decision of the competent Railway authority is final and binding on the contractor.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Electrical General work in connection with "Water balancing of South Tank with North Tank through underground pipe line with sump well, pump house & desilting, slope protection etc. of south Tank at Liluah under CWM/LLH"
W_LLH_02_2026-27~ER
W_LLH_02_2026-27
Open
Works - General
6 Months
Howrah, West Bengal
₹0
₹62,100
15 Jun 2026
27 May 2026
1 Jun 2026
65 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 31,02,805.33 | ||
| — | 50.00 | — | — | ||
| Supply of ISI marked LT XLPE insulated, PVC outer sheathed, non-magnetic galvanised steel strip armoured, stranded compact circular Aluminium conductor cable of size 4 core x 35 sq. mm nominal system Voltage 11000V grade and highest system voltage 1210 V conforming to IS 7098(Part I-1988 ) with amendment number 1 and 2 and 3 reaffirmed 2005 or lastest ( Make: Anchor/ KDK/ Gloster/ Havells/ Polycab/ KEI/ Nicco/ Finolex/ RR kabel/ Mescab) (S= 460.20, L= 0.00) | — | — | — | 23,010 | |
| — | 50.00 | — | — | ||
| Supply of ISI marked LT XLPE insulated, PVC outer sheathed, non-magnetic galvanised steel strip armoured, stranded compact circular Aluminium conductor cable of size 4 core x 70 sq. mm nominal system Voltage 11000V grade and highest system voltage 1210 V conforming to IS 7098(Part I-1988 ) with amendment number 1 and 2 and 3 reaffirmed 2005 or lastest ( Make: Anchor/ KDK/ Gloster/ Havells/ Polycab/ KEI/ Nicco/ Finolex/ RR kabel/ Mescab) (S= 414.89, L= 0.00) | — | — | — | 20,744.5 | |
| — | 300.00 | — | — | ||
| Supply of ISI marked LT XLPE insulated, PVC outer sheathed, non-magnetic galvanised steel strip armoured, stranded compact circular Aluminium conductor cable of size 4 core x 185 sq. mm nominal system Voltage 11000V grade and highest system voltage 1210 V conforming to IS 7098(Part I-1988 ) with amendment number 1 and 2 and 3 reaffirmed 2005 or lastest ( Make: Anchor/ KDK/ Gloster/ Havells/ Polycab/ KEI/ Nicco/ Finolex/ RR kabel/ Mescab) (S= 1010.48, L= 0.00) | — | — | — | 3,03,144 | |
| — | 70.00 | — | — | ||
| Laying, jointing, connection, testing& commissioning of LT cable 1100V grade of higher size (above 95 sq.mm.) along the wall/catenary or garder truss by necessary clamping arrangement including socketing and termination with epoxy end jointing where necessary (clamp should be made of 50mm x 6mm M.S. Flat) (S= 74.00, L= 53.00) | — | — | — | 8,890 | |
| — | 200.00 | — | — | ||
| Laying of cable through HDPE Pipe by Micro tunnelling Process including termination of both end with necessary Nut & bolt, suitable rating socket, gland, PVC tape , cable jointing kits etc. (S= 335.00, L= 745.00) | — | — | — | 2,16,000 | |
| — | 100.00 | — | — | ||
| Laying, jointing, connection, testing& commissioning of LT cable 1100V grade of higher size (up to 95 sq.mm.) along the wall/catenary or garder truss by necessary clamping arrangement or concealed through wall with make good including socketing and termination with epoxy end jointing where necessary (clamp should be made of 50mm x 6mm M.S. Flat) (S= 41.00, L= 23.00) | — | — | — | 6,400 | |
| — | 30.00 | — | — | ||
| Cutting of concrete and trenching drawing laying and jointing of the 1100V grade cable through underground as per CEE's drawing no. E4/GPST/033/87 and refilling the trench after laying the cable including making good the damages and then smooth flooring and re-concreting (18" wide x min 3' deep) with cement , sand,& stone chips in ratio 1:2:4 and connection with switchergear along with supply of suitable size gland, socket etc as required. (S= 240.00, L= 206.00) | — | — | — | 13,380 | |
| — | 2.00 | — | — | ||
| Supply,digging,insertion, testing and commissioning of earth pipe made of heavy duty GI pipe of Size 50 mm dia, 3 mtr long (Conforming to IS:1239 PART-1 (2004) or latest) (Make: TATA, JINDAL, SKIPPER, Nezone (or) ISI equivalent ) including construction of earth pit and each pit should be provided with 2 nos. of above pipe duly shorted by suitable length of G.I flat ( 50 mm x 6 mm) including necessary earth connection from pit to the distribution panel with 4 SWG GI wire. The earth pit should be encashed with panel with alternate layer of salt and charcoal to be spreaded inside the pit. Eatth pit shall be completed with necessary civil work like brick chamber, PCC work & finally covered with medium duty cast iron hinged cover of size 400 x 400 mm sq. N.B: The earthing should be done as per CEE/KKK's specification. All earth value should be marked on MS plate with date by painting work. The MS flat, plate should be painted by one coat of Red Oxide annd 2 coats of Black paint before execution. The marking should be done by white paint. (S= 3962.15, L= 657. 39) | — | — | — | 9,239.08 | |
| — | 3.00 | — | — | ||
| Supply ,Fixing ,connection,testing and commissioningof indoor type,surface mounted 18-20 Watt integrated batton LED fitting with BIS certified driver and luminare, operating voltage of 150-270 Volt having industrial grade constant current driver (minimum driver efficiency of 85% ),ingress protection of IP 20 (or better),impact protection of IK03 (or better),minimum system lumen efficacy of 100 Lm/W (or higher), LED life of 50000 burning hours (or greater), aluminium housing ,color temperature of 6500K,CRI>=80,THD<= 20%,PF>=0.95,SPD>= 2 KV with all accessories for erection of the same(Make- As per explanatory note/ Schedule) (S= 294.00, L= 166.00) | — | — | — | 1,380 | |
| — | 3.00 | — | — | ||
| Supply, fixing, connection, testing and commissioning of indoor type, surface mounted 2x18-20 Watt LED fittings with 2x18-20 Watt LED luminaries of BIS certified driver, operating voltage of 150-270 Volt industrial grade constant current driver (minimum driver efficiency of 85%), ingress protection of IP20 (or better), impact protection of IKO3 (or better), minimum system lumen efficacy of 100Lm/W (or higher), LED life of 30000 burning hours (or greater), aluminium housing, colortemperature of 6500K, CRI>=80, THD<=20%, PF>=0.90, SPD>=2KV with all accessories for erection of the same. (Make: As per Explanatory Note) (S= 795.00, L= 267.00) | — | — | — | 3,186 | |
| — | 6.00 | — | — | ||
| Supply, fixing, testing and commissioning of outdoor type 90 Watt LED street light luminaries with BIS certified driver and luminare, operating voltage of 140-270 Volt having industrial grade constant current driver( minimum driver effiency of 85% ), ingress protection of IP 65(or better) , impact protection of IK 07(or better), minimum system lumen efficacy of 100 Lm/W (or higher), LED life of 50000 burning hours (or greater), pressure die cast aluminimum housing , color tempreature of 5700k CRI>= 70, THD,= 20%, PF>= 0.95,SPD>= 4 KV with all accessories for erection of the same complete with necessary clamping arrangement with heat resistance toughened glass,minimum IP 65 protection with individual LEDs,better optics for uniform distribution. High efficacy Operating input volt along with all fixing accessories including bend pipe and fixing arrangement at per site condition (in Volts) 140-270 (make, Crompton , Bajaj,Philips, Havells, Orient,Halonix or equivalent) (S= 4100.00, L= 0.00) | — | — | — | 24,600 | |
| — | 1.00 | — | — | ||
| Supply fixing , installation ,testing and commissioning of 8 Way, MCB DB 240 V , 50 HZ complete with enclosure with metal door 1 NO 40 Amp DP Isolator and 6 NOS. SP MCB 6-32 Amp (as required) including connection and concealed with necessary arrangement ( MCB, DB, Isolator make: LK(L&T), Siemens, ABB, C&S, Havells, Legrand,standard). ( MCBs should confirm to IS/IEC 60898-1 or latest & 60947-2 or latest )(Isolator should confirm to IS/IEC 60947-3 or latest) ( DB should confirm to IEC 61439-1&3 & IS 8623 -1&3 or latest with CRCE sheet steel). (S= 2003.00, L= 207.00) | — | — | — | 2,210 | |
| — | 1.00 | — | — | ||
| Supply, Fixing & connection of 450 mm sweep Heavy Duty Single Phase IP 55 & ISI marked metal exhaust fan with necessary masonry work (Crompton make Cat no. EXHD450-4-1 (450mm 1400 rpm S.Ph.) or similar ) ( Make Havells, Crompton, Bajaj, Usha,Polar,Orient). (S= 8499.00, L= 199.00) | — | — | — | 8,698 | |
| — | 30.00 | — | — | ||
| Wiiring of submain with 2 nos. of single core HRFR/FRLSH PVC insulated stranded Copper conductor cable of size 6 sq. mm.,1100 V grade confirming to IS 694/2010 in suitable size heavy guage PVC pipe in concealed along with PVC insulated copper conductor cable of size 2.5 sq. mm for ECC.(Wire make : Finolex ,KDK, Havells, Polycab, Standard, RR Kabel) (S= 116.85, L= 0.00) | — | — | — | 3,505.5 | |
| — | 14.00 | — | — | ||
| Wiring of light points, fan points,bracket fan points, exhaust fan point, sinage light, call bell point with 2.5 sq. mm. multi-strand single core HRFR/FRLSH PVC insulated copper conductor cable 1100 V grade confirming to IS 694/2010 in suitable size heavy guage PVC pipe in concealed along with PVC insulated copper conductor cable of size 1.0 sq. mm for ECC & suitable size heavy gauge PVC board, switches should be of modular type and all other accessories. (Wire make : Polycab, Havells , Finolex, KDK, KEI, RR Cable, mescab, gloster) , (5Amp switch make -Anchor, Crabtree, Legrand, LK(L&T) , HPL, standard) (S= 473.64, L= 0.00) | — | — | — | 6,630.96 | |
| — | 2.00 | — | — | ||
| Wiring of 6A/5 pin plug point with single core HRFR/FR-LSH PVC insulated multi-strand Copper conductor cable of size 1.5 sq. mm.,1100 V grade confirming to IS 694/2010 in suitable size PVC pipe in concealed with PVC insulated copper conductor cable of size 1.5 sq. mm for ECC. & suitable size heavy gauge PVC board. switch & socket should be of Modular type .(Wire make : Polycab,Havells , Finolex,KDK, KEI, RR Cable,mescab, gloster) , (5 amp switch, socket make -Anchor, Crabtree, Legrand, LK(L&T), HPL,standard ) & haevy gauge PVC pipe/Conduit or casing /capping- ( PRICISION/AKG/PCG) (S= 215.86, L= 0.00) | — | — | — | 431.72 | |
| — | 2.00 | — | — | ||
| Wiring of 16/6 Amp 6 pin plug point with single core HRFR/FRLSH PVC insulated multistrand Copper conductor cable of size 4 sq. mm.,1100 V grade confirming to IS 694/2010 in suitable size PVC pipe in concealed and made 16/6 Amp socket and switch along with PVC insulated copper conductor cable of size 2.5 sq. mm for ECC. & suitable size heavy gauge PVC board. Switch & socket should be of Modular type (Wire make : Polycab,Havells , Finolex,KDK, KEI, RR Cable,mescab, gloster) , (16 amp switch, socket make -Anchor, Crabtree, Legrand, LK(L&T) , HPL,standard ) & haevy gauge PVC pipe/Conduit or casing /capping- ( PRICISION/AKG/PCG) (S= 720.72, L= 0.00) | — | — | — | 1,441.44 | |
| — | 2.00 | — | — | ||
| BLDC ceiling fan of sweep 1200 mm, air delivery range from 245 cubic meter per minute to 272 cubic meter per minute and input power consumption range from 26W to 28W (Star rating - 5 star, Class of insulation-'F' ,service value -7.4 & above cubic meter per minute per watt) with remote for speed control of fan suitable for operation on 1 Ph, 50Hz, 240V power supply system (Confirm to all the performance requirements laid down in IS 374:2019 or latest, including all amendments, as applicable) with 60 months warranty (BLDC Ceiling Fan Make and detailed TDS: As per explanatory Note) (S= 2975.27, L= 0.00) | — | — | — | 5,950.54 | |
| — | 2.00 | — | — | ||
| Supply of 3.0 ft MS down rod for hanging new ceiling fan including GI clamps made of GI flat of suitable size and GI nut bolts for hanging of MS down road from ceiling. (S= 96.53, L= 0.00) | — | — | — | 193.06 | |
| — | 2.00 | — | — | ||
| Fixing, connection and commissioning of new BLDC ceiling fan by GI clamps made of GI flat of suitable size and GI nut-bolts along with down road arrangements (as per site condition) including transportation from site to stores. (S= 77.72, L= 25.36) | — | — | — | 206.16 | |
| — | 2.00 | — | — | ||
| Supplying of 80000 GPH (approx.) portable type non clog Submersible sewage/ drainage Pump motor set (IE 4 or above), power supply 3 Ph, 415 V , 50 Hz, soft solid handling size 80 to 125 mm., discharge dia- 200 mm with main cable , control cable, pedestal auto coupling , Guide pipe G.I. 6 m length, Duck foot bend with tool box etc.( Detailed specification of pump motor set as per Annexure A) (S= 720866.25, L= 0.00) | — | — | — | 14,41,732.5 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of submersible pump starter, auto transformer stsrter of 30HP (80000 GPH) with ammeter, voltmeter, selection switch of ammeter & voltmeter , selector switch of ammeter & voltmeter, single phase preventer thermal overload with Water level controller along with hard copy of circuit diagram and operation mannual ( make LK(L&T), BCH, SIEMENS, C&S) (S= 31078.86, L= 0.00) | — | — | — | 62,157.72 | |
| — | 4.00 | — | — | ||
| Supply of SS Lifting chain with shackle (15 m length per pump) (S= 14180.61, L= 0.00) | — | — | — | 56,722.44 | |
| — | 4.00 | — | — | ||
| Supply of 200 mm dia C.I. D/F Duck Foot Bend 90° with flange. (S= 29661.19, L= 0.00) | — | — | — | 1,18,644.76 | |
| — | 2.00 | — | — | ||
| Supply of suitable dia. Reputed make C.I. D/F Non rising sluice valve rating PN1.0 Conforming To IS 14846 : 2000 (S= 10675.67, L= 0.00) | — | — | — | 21,351.34 | |
| — | 30.00 | — | — | ||
| Supply of 200 mm dia 8 mm thick GI Pipe ( Make TATA, Jindal). (S= 2671.86, L= 0.00) | — | — | — | 80,155.8 | |
| — | 2.00 | — | — | ||
| Supply of 2 ton capacity INDEF 'M' or its equivalent make SS chain pulley block with lifting chain with Hooque , handling chain in standard length ie. 6 mtrs. (S= 36580.82, L= 0.00) | — | — | — | 73,161.64 | |
| — | 2.00 | — | — | ||
| C I Non-rising spindle non return valve (PN 1.6) of size - 200 mm ISI marked as per latest IS 5312 (S= 22600.00, L= 0.00) | — | — | — | 45,200 | |
| — | 2.00 | — | — | ||
| Installation , fitting , fixing, commissioning of pump motor set with electrical control panel & above supply, delivery pipeline upto installation of valve ( Installation of all items from sl no. 21 to 28) with foundation of control panel and all necessary civil work as required including foundation of beam structure for hanging of pump and cleaning of sump ( Foundation & Installation as per site condition with all accessories, CPWD norm will be followed) (S= 82287.56, L= 0.00) | — | — | — | 1,64,575.12 | |
| — | 2.00 | — | — | ||
| Supply, installation, fixing , testing, connection, and commissioning of 400 Amp Changeover switch with SS Enclouser (Havells cat no. IHCPFE0400 or similar) with Cable entry box with gland socket and thimble for connection of cables. (installation as per site condition with all accessories) (S= 32080.00, L= 0.00) | — | — | — | 64,160 | |
| — | 1.00 | — | — | ||
| Supply, foundation,installation, connection,testing and commissioning of indoor type 14 SWG LT M.S.Distribution panel board with castle lock arrangement consisting of the following. (i)MCCB 400 Amps, 4 pole, 35 KA,415 Volt as incoming with inbuilt overload , short circuit and ground fault protection -2 Nos., (ii) MCCB 100A, 4 pole, 35 KA, 415 Volt as incoming with inbuilt overload , short circuit and ground fault protection -8Nos, (iii) Timer with contactor of 70 A, 4-pole along with by pass arrangement- 2 sets,(iv) Multi functional Digital type metering system such as energy meter, trivector meter,voltmeter, ammeter etc. with LED indication lamp -1 set, (v)4 pole copper bus bar 600 Amp,capacity-1 set. (vi) Suitable MS Enclouser-1 set. (vii) Cable entry box with gland socket and thimble for connection of cables. MCCBs should confirm to IEC:60947-II / IS:13947-II) (MCCBs make : Siemens , GE , Hager, LK(L&T), Havells, Legrand, ABB) ( Digital meters make: CONSERVE/ SECURE, LK(L&T), Havellls) with foundation as per CPWD norm. (S= 255927.53, L= 22062.72) | — | — | — | 2,77,990.25 | |
| — | 2.00 | — | — | ||
| Supply of Special Type staff locker, overall size:- Height-1995mm, Width-1020mm, Depth- 495mm, Leg Height- 76mm consisting of 12 nos cages of size:- Height-420mm, Width-305mm, Depth- 495mm, with individual locking arrangement. All MS Sheet thickness- 1.2mm, and conforming to IS:513-2008, Gr. CR1 with overall Powder Coated painting of Off-White colour. ( Warranty Period : Upto 30 months from the date of supply) Make- Godrej/ Steelco/Bajaj or similar. (S= 18856.40, L= 0.00) | — | — | — | 37,712.8 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
2018_CE-I_CT_9Date04_06_2018LetterofCredit.pdf
ATTACHMENT
AnnexureV_1.pdf
ATTACHMENT
BankGuaranteeBondAnnexure-VIA_1.pdf
ATTACHMENT
RBA__48_09052018_1.pdf
ATTACHMENT
RBA_10_21022018_1.pdf
ATTACHMENT
GCCApril-2022_1.pdf
ATTACHMENT
VerificationofContractualStaff_1.pdf
ATTACHMENT
CommercialCompliance2022_1.pdf
ATTACHMENT
GeneralCompliance2022_1.pdf
ATTACHMENT
OnlinePoliceVerification_1.pdf
ATTACHMENT
Undertaking2022_1.pdf
ATTACHMENT
TenderForm_1.pdf
ATTACHMENT
ExplanatoryNote-I1682_1.pdf
ATTACHMENT
ExplanatoryNote-II1682_1.pdf
ATTACHMENT
Annexure-A1682_1.pdf
ATTACHMENT
ConservencyCharges07-09-2021.pdf
ATTACHMENT
RBE_20_18.02.2020LabourLaws.pdf
ATTACHMENT
LabourDataShramikKalyanPortal17.10.2018.pdf
ATTACHMENT
InsuranceSuretyBondDated.09.01.2025inGCC.pdf
ATTACHMENT
AdvanceCorrectionSlip1to10toGCCcombined_compressed.pdf
ATTACHMENT
2026_03_13IndianRailwaysStandardGeneralConditionsofContractApril2022AdvanceCorrectionSlipNo_111-compressed.pdf
ATTACHMENT
checklist.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .