Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹46.3 LAccepted-AOC RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | ₹46.3 L | 1 | Accepted-AOC Being lowest and reasonable rates |
| 2 | 2₹51.5 L+₹5.3 L (11.3%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | ₹51.5 L+₹5.3 L (11.3%) | 2 | Rejected-Finance Not being a lowest tenderer |
| 3 | 3₹54.2 L+₹8.0 L (17.2%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹54.2 L+₹8.0 L (17.2%) | 3 | Rejected-Finance Not being a lowest tenderer |
| 4 | 4₹55.3 L+₹9.0 L (19.4%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | ₹55.3 L+₹9.0 L (19.4%) | 4 | Rejected-Finance Not being a lowest tenderer |
| 5 | 5₹57.2 L+₹11.0 L (23.7%)Rejected-Finance | ₹57.2 L+₹11.0 L (23.7%) | 5 | Rejected-Finance Not being a lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
23 Dec 2020, 6:00 pmClosed
CWE U
HQ CWE U Delhi Cantt 110010
Repair replacement and maintenance of 33 KV and 11 KV Power Transformer Switchgear Relay at Shankar Vihar grid and Repair Replacement to underground HT Cable and connected items in various units at Shankar Vihar and associated area of AGE U Elect Sup
2020_MES_387399_1
89035/CWE(U)/D-25/2020-21/E8
Open Tender
Electrical and Maintenance Works
Item Wise
180 days
Delhi Cantt
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Yes
GE U Electric Supply
₹1.6 L
Yes
22 Jan 2021
29 Oct 2020
25 Dec 2020
29 Oct 2020
23 Dec 2020
11 Dec 2020
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 m deep in soft/loose soil for laying of cables or GI pipe and getting out including levelling of bottom suface to required level complete all as specified and as directed.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc,complete all as specified and as directed. Note : Only Punned Sand shall be measured and paid for.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mmcomplete all as specified and as directed.
Laying only old HT cable cover obtained from excavation complete all as specified and as directed.
Returning filling in,. including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing excavated material (ie soil) from site to a distance n. exc 50 m away and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and as directed.
Supplying, laying, testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 Part-II marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and as directed of following sizes :- Note : Excavation, Earth work, Cable protection, sand filling and Cable Joints shall be measured and paid separately in respective item of this BOQ.
95 sqmm 3 core.
120 sqmm 3 core.
185 sqmm 3 core
240 sqmm 3 core
300 sqmm 3 core
M & L for Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 100 to 160 mm bore and making good both ends complete all as specified and as directed.
Supply and laying GI pipe light grade in replacement as cable protection laid in trench/floor, fixed on pole/wall etc complete all as specified and as directedof following sizes :-
100 mm dia bore
80 mm dia bore
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and as directed of following size :-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm, 3 core.
240 Sqmm to 300 Sqmm 3 core
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and as directed of following size :-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm, 3 core.
240 Sqmm to 300 Sqmm 3 core.
Supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and as directed of following size :-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm, 3 core.
240 Sqmm to 300 Sqmm 3 core.
Supply and fixing in replacement air break switch gang operated tripple pole mechanically operated mechanism, switch air break gang operated mounted on 15 Nos insulator and steel frame with operating rod of 25 mm bore GI Pipe and locking arrangements worked from ground level for current rating 400 Amps, HT 11 KV grade including drop out fuses and necessary silver coper coating jumpers and making all electrical connections complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 , connected to earth test point and the equipment on the other nuts and washers of galvanised iron complete including taking down, testing and commissioning complete all as specified and directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
M&L for 2 coat of aluminium painting over a coat of red oxide to steel surfaces of HT PCC Pole or MS 2/4 Pole structure (Angle Iron/Ms channel/MS clamp etc) including preparationof old surface complete all as specific and as directed.
All as per Serial item No 15 here-in-before but 6/8 pole structure incoming/outoing feeder.
Material & Labour for replacement of Perished/Corroded/ Jumper bar made of ACSR conductor of existing size on HT Four/Six pole structure having 2/3 incoming/outoing feeder including bus bar with PVC sleeve , lugs , nut bolts and washers complete all as specified and as directed.
S&F in replacement Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint on 4/6 pole 11 KV HT structure complete all as specified and as directed.
M & L for cutting and removing grass, vegetation bushes etc from surrounding 4 pole/6 pole HT structure/ 33 KV yard and etc , outside area of HT installation and removing all rubbish to a distance not exceeding 50 m complete all as specified and as directed.
Material and labour for spreading of stone aggregate of nominal size not more than 25mm under 4/6 pole HT structure /surounding area of outdoor RMU manually without damaging any equipments, cable or parts , spreading & levelling of finished gravel uniformaly in layers n. exc. 15 cm thick and rammed to true surface complete all as specified and as directed.
Suplying only in replacement in sub station 3.3 to 11 KV electrical insulation mat IS Marked of size 1 meter wide x 10 meter length and 2 mm thick conforming to IS 15652.
Re-Adjustment, Cleaning of Contact, greasing and testing of out door type Air break switch 11 KV, current rating upto 400 Amps for desired alignment to smooth operation from ground level and replacement of unserviceable parts in position. Note : Replacement of unserviceable parts shall be measured and paid separately under relevant items of this BOQ complete all as specified and as directed.
Supplying and fixing in replacement male contact/moving contact of 400A for gang operated air break device 11 KV complete all as specified and as directed.
Supplying and fixing in replacement female contact /fix contact of 400A jaw for gang operated air break device 11 KV complete all as specified and as directed.
Supplying and fixing in replacement tinned copper flexible jumper 400 Amp for gang operated air break device 11 KV complete all as specified and as directed.
Supplying and fixing in replacement MS jumper carrier for gang operated air break device 11 KV complete all as specified and as directed.
Supplying and fixing in replacement back connector plate for gang operated air break device 11 KV complete all as specified and as directed.
Supplying and fixing in replacement porcelain post insulator for gang operated air break device 11 KV complete all as specified and as directed.
Supplying and fixing in replacement drop out fuse element 5 to 25 Amp ccomplete all as specified and as directed.
Supplying and fixing in replacement drop out fuse element 50 Amp complete all as specified and as directed.
Supplying and fixing in replacement drop out fuse element 60Amp complete all as specified and as directed.
Supplying and fixing in replacement drop out fuse element 100 Amp complete all as specified and as directed.
S&F in replacement disc type insulator,porecelain, viterous 145mm high and 255mm dia ball and socket type , brown tow in series assembly for tension with tension clamps for conductors, working presseue 11000 volts ccomplete all as specified and as directed.
S&F in replacement pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers,nut size 150 mm height 150mm dia, 11000 volts grade complete all as specified and as directed.
S&F in replacement for Danger Notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white , with letters, figures and conventional skull and bobes in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT, 25x20 cm size including taking down old one complete all as specified and as directed.
S&F in replacement of Lightening arrestors expulsion type with all fittings, transmission class, discharge capacity 10 kilo Amps suitable for 11000 volts ccomplete all as specified and as directed.
Demolition of path /concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Material and labour for Cement Concrete type B-2, 1:2:4 (40mm graded aggregate) finishing the top surfaces fair and even complete all as specified and as directed.
Dismantling the existing unserviceable (damaged/broken) PCC electric pole of any type and size, from ground after necessary excavation & breaking of concrete foundation & encasing the pole including making good the disturbed surfaces complete all as specified and as directed.
Supplying, Errection & fixing in replacement Steel Tubular Swaged Poles, type 410 SP-55 (11 metres long) complete with cast iron base plate all as specified in IS including the followings:- (a) Excavation in post holes in any types of soil up to 1.6 mtr depth from GL, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 m from the starting points and paid under respective items. (b) Providing PCC (1: 4:8) type D-2 using 40 mm graded stone aggregate as in foundations up to ground level all as specified and directed. (d) Providing PCC (1:2:4) type B-2 using 20 mm graded stone aggregate as in coping including necessary form work all as specified and directed. (e) Painting of Poles with one coat of red oxide primer and one coat of aluminum paint before fixing and one coat of aluminum paint after fixing. The complete embedded portion shall be painted with two coats of black bituminus paint. Note:Earth work and PCC shall be measured and paid under relevant Items of this BOQ.
Supplying and fixing (in replacement) anti climbing device, spikes type, fabricated out of mild steel bars of size 16 Sqmm (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete with and including painting with two coats of aluminium paint over a coat of red oxide primer to match it with existing surfaces complete all as specified and as directed.
M&L for painting with two coats of superior aluminium paint including necessary preparation of old surfaces of wire mesh / matte steel fencing by brushing/cleaning complete steel structure/frame/ gate for 11 KV transformer/2 pole to 8 pole structure/ HT panels/Sub Station up to 30 Sqmm arera complete all as specified and as directed.
Material and labour against replacement for Pre-cast reinforced cement concrete cover slabs for cable duct of any size, Type B1, 1:2:4 mix (using 20 mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in Cement Mortar. 1:4 of suitable size for carrying handle complete all as specified and as directed.
Material and labour for Mild steel bars 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for columns,for PCC slab hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Supplying and fixing (in replacement) 4 mm dia MS wire 75x75mm mesh, made upto into mattress or cages appx 2.00 m height and fixed on existing flat iron/angle as per existing by welding in position complete all as specified and as directed.
Material and labour for two coats of synthetic enamel paint of silver colour on steel surfaces over a coat of red oxide primer including preparation of surfaces complete all as specified and as directed.
Material and labour for PCC 1:3:6 type C-2, (using 40 mm graded crushed stone aggregate) for foundation, filling and mass concrete etc complete all as specified and as directed including dismantling of old unserviciable PCC.
Material and labour Brick work with sub-class 'B' bricks, straight or curved on plane exc 6 m mean radius, built in cement mortar 1:6 complete as specified and as directed including dismantling of old unserviciable brick work.
Material and labour Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) finished fair and even without using extra cement complete all as specified and as directed.
Material and labour for cement concrete type D-2, 1:4:8 (using 40 mm graded crushed stone aggregate) for sub floors, sub-bases, floors and paving etc complete all as specified and as directed including dismantling of old unserviciable PCC.
Material and labour for cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) for floors and paving etc complete all as specified and as directed including dismantling of old unserviciable PCC.
M & L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 200 mm dia suitable for 0.6 mpa working pressure. Note For Sr No 8 & 52 Above : The Rate for taking permission from concerned authorities like MTNL, Army Signal, BSES and other utility authority are deemed to be included in the quoted rates. If any utilities services like road are damaged during execution of work , the same will be repaired/replaced/ made good by the Contractor without any additional payment by the Department.
Material and labour for servicing of HT control panel including outdoor CT, PT and relays in control panel of outdoor SF6 breaker of capacity 1250 Amps and rating 36 KV complete all as specified and as directed as details mentioned as under:- Details of servicing of HT Panel (breaker) :- (i) Checking of Closing/Tripping coil assembly (ii) Adjustment of mechanism if required. (iii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth. (iv) Checking the contact for wear. Replace if the contact piece has worn out. (v) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (vi) Check for rust and wear. (vii) Checking of spring charge mechanism (viii) Visual check for rust and deformation. (ix) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (x) Check for loosened connections, rust, damaged lead wires.
(xi) Checking of control circuit & tighten the connections if any. (xii) Check close & trip coil. (xiii) Replacement of Dashpot/shock absorbers . (xiv) Replacement of carbon brush of spring charging motor (xv)Cleaning of porcelain bushing (xvi)Checking of limit switch Note :- Spare parts shall be measured & paid in respective items of this BOQ.
Opening of the VCB/OCB , 11 KV 400 to 800 Amps of any make by removing of the Breaker from the existing position after disconnecting all the connections from the system, servicing, Overhauling of the same, checking of the same for proper operation, spring charge, charged control cables are fastened tightly to the terminals, any abnormality, VCB, cleaning the surface of the insulators, fasten the bolts, checking and correcting interrupting units, mechanism, linkages etc, fasten the hardwares of control wiring, check that the split pins, Circlips, dowell pins etc. have not come out and are intact, lubricate the mechanism, moving parts by castrol, all purpose grease or equivalent, check that the vaccum pots/chambers is within limit including opening of the shutters properly, replacing of the trip catch, roller, holding catch, stopper, close push button, closing cum reassembling, controll limit switches reconnecting of the breaker for smooth functioning complete all as specified and as directed.. Note :- Spare parts shall be measured & paid in respective items of this BOQ.
Decarbunizing/cleaning complete HT 11KV, 3 phase independent main bus bar, section bus bar chamber of HT panel electrification connection complete, consisting of set of 3 to 5 HT VCB switch gear arrangement incoming and outgoing installed in sub-stations after removing the complete bus bar spout, circuit spout from the bus bar chamber/cleaning with CRC and ensure proper decarburizing, re-fixing the same after applying backtol (Red) solution to the spout, checking all the connections, tightening the nuts, bolts thimbles for incoming and outgoing systemcomplete all as specified and as directed. and rate quoted is inclusive of bactol red, CRC & cotton waste provided by contractor.
Decarbunizing/cleaning complete HT 11KV, 3 phase independent main bus bar, section bus bar chamber of HT panel electrification connection complete, consisting set of 6 to 10 HT VCB switch gear arrangement incoming and outgoing installed in sub-stations after removing the complete bus bar spout, circuit spout from the bus bar chamber/cleaning with CRC and ensure proper decarburizing, re-fixing the same after applying backtol (Red) solution to the spout, checking all the connections, tightening the nuts, bolts thimbles for incoming and outgoing system complete all as specified and as directed.and rate quoted is inclusive of bactol red, CRC & cotton waste provided by contractor.
Decarbunizing/cleaning complete HT cable ougoing/Incoming circuit of CTs & PTs, 3 phase, cleaning with CRC and ensure proper decarburizing, re-fixing the same checking all the connections, tightening the nuts, bolts thimbles for incoming and outgoing system complete all as specified and as directed. and rate quoted is inclusive of CRC & cotton waste provided by contractor.
Material and labour for testing and calibration of 11 KV HT Panel complete all as specified and as directed as mentioned under - (i) Primary Injection Test of CT / PT (ii) Closing & Opening Timing Test for all three poles. (iii) IR Test with megger in open and closed condition. (iv) Contact resistance test for all three poles (v) Closing coil resistance (vi) Tripping coil resistance. Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay :- (i) Over current and earth fault relay (ii) DC Supply supervision relay. (iii) Master trip relay Note:- (I) DC Supply for relay testing shall arranged by the contractor.
M&L for ON load / ON line Centrifuging and dehydration including filteration and cleaning of transformer oil by dehydration machine of 33 KV transformer at site and topping up deficient transformer oil including testing of samples before and after dehydration and filteration complete all as specified and as directed. Note :- Deficient quantity of Transformer oil required for top up shall be measured and paid separately under respective item of this BOQ as supply only.
Supply only transformer oil of approved quality as per IS having dielectric strength of 45-60 KV in 2.5mm gap for filling in OLTC & for topping up in transformer complete all as specified and as directed.
Supply only in replacement of closing coil assembly 50 volts DC of existing make for SF 6 breaker of capacity 1250 amps of rating 36 KV complete all as specified and as directed.
Supply only in replacement of tripping coil assembly 50 volts DC of existing make for SF 6 breaker of capacity 1250 amps of rating 36 KV complete all as specified and as directed.
Supply only in replacement of closing coil assembly 50 volts DC of existing make for VCB of capacity 400/630 amps of rating 36 KV complete all as specified and as directed.
Supply only in replacement of tripping coil assembly 50 volts DC of existing make for VCB of capacity 400/630 amps of rating 36 KV complete all as specified and as directed.
Material & labour for servicing of OLTC ( On load tap changer ) of 33KV/11KV Power transformer of capacities 8/10 MVA at site by carried out following work of Schinder/ABB make :- (a) Opening of top plate of OLTC. (b) Draining out of transformers oil from the OLTC. (c) Stoping of leakage of oil from main shaft of OLTC including replacement of oil seal and all gasket of OLTC. (d) Checking /servicing of moving and fixed contact of OLTC and resistence test of contact. (e) Flushing of OLTC assembly with hot new oil and removing of sludge. (f) Filling of new transformer oil in OLTC . (g) Tightening of all tapping leads and connections. (h) Refixing of top plate of OLTC in original position after overhauling. (i) Electrical testing of manual/auto operation of OLTC. Note :- Transformer oil as required shall be measured and paid separately under respective item of this BOQ as supply only.
Material and labour for spreading of stone aggregate of nominal size not more than 40mm from the bay/yard manually without damaging any equipments, cable or parts of the 33 KV Grid bays, filling,spreading & levelling of finished gravel uniformaly in layers n. exc. 15 cm thick and rammed to true surface complete all as specified and as directed.
M&L for Servicing & Repairs to Air-break switch (isolator) off load, rotating type, 33 KV, 800 Amps to 1250 Amps capacity, with proper alignment of isolator rotating blades, with fixed contact jaws, arcing horns, applying petrolium jelly to moving mechanism, cleaning and lubricating to isolator gear box assembly, tightening all nuts, bolts and clamps of jumpers etc, repairing to isolator gear box assembly and making in proper serviceable condition for smooth functioning, testing and commissioning on load complete all as specified and as directed. Note : Spares shall be measured and paid separately under relevant items.
Supplying only in replacements, male/moving contact/ rotating blade of HDE copper silver plated of Air Brake, off load isolator switch, rotating type, 33 KV, 1250/800 Amps capacity with all fixing nuts, bolts etc complete all as specified and as directed.
Supplying only in replacements, Fixed Contacts, made of HDE copper, silver plated, of Air Brake, off load isolator switch, rotating type, 33 KV, 1250/800 Amps capacity with all fixing nuts, bolts etc. complete all as specified and as directed.
Supply, installation, testing and commissioning in replacement of lightening arrestor SMX type at door complete with all fittings transmission class 36 KV 10 KA 50 Hz suitable for system voltage 33/36 KV complete all as specified and as directed.
Supplying ,fixing , testing of master trip relay in replacements , 24 Volt DC in control panel including wiring complete all as specified and as directed.
Supplying ,fixing , testing of master trip relay in replacements ,110V Volt DC in control panel including wiring complete all as specified and as directed.
Supplying ,fixing , testing of master trip relay in replacements ,50 Volt DC in control panel including wiring complete all as specified and as directed.
Supplying ,fixing , testing of Trip circuit supervision relay in replacements, 50 Volt DC in control panel including wiring complete all as specified and as directed.
Supplying ,fixing , testing of DC supervision relay in replacements, 50 Volt DC in control panel including wiring complete all as specified and as directed.
Supplying and fixing PT fuse for 11 KV/110 V PT complete all as specified and as directed.
Supply installation & commissioning in replacement of 24V/30A Bank, three Phase , Float Cum Boost Battery Charger unit including battery bank comprising 12 Nos of 2 Volts-100 AH sealed maintenance free battery. The CCCV battery charger consisting of copper wound, air cooled transformer, 01 Set single phase full wave bridge rectifier consisting of diodes and SCRs, liberally rated mounted on heat sink and complete with resistor/condenser network for surge supperssion . During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DC digital ammeter , DC digital voltmeter, Potentiometer , DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility for fuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation , gland plate will be provided for cable entry from bottom .
The battery charger shall be divided into two compartments.The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries at Shankar Vihar control Panel room. Tech specification shall be as under:- (a) Input working voltage-180 -270 Volts (b) Nominal Input Voltage - 230 V , AC , 50 Hz,1 (c) On load input power factor - > 0.8 (d) On load unit watt efficiencies-> 80% (e) No load losses of complete charge-< 10% (f) Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition. (h) Boost charging - 2.4 V/Cell . (j) Float charging -2.15 V/Cell
(k) Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode. (l) Reverse polarity -No damage will caused . A visual indication for reverse polarity will appear with an audio alarm. (m) Short circuit-MCB protecton provided.
Supply and laying in replacements PVC insulated PVC sheathed cable galvanized steel strip or wire armoured electric control cables (Heavy duty) with stranded Copper conductor of size 2.5 sq mm 10 core 1100 Volts grade complete all as specified and as directed.
All as per item No. 79 above but 2.5 sqmm 6 core copper conductor.
Supply, installation and testing in replacement of over current & earth fault feeder protection relays comprising of the following protection auxillary working voltage at 110 V to 24 V DC supply, with 4 count inputs CT / 5 / 1 A, 5 discrete & 9 discrete outputs DNP3, modbus RTC, IEC 60870-5-103 communication flush mounted (a) over current ANSI code 50/51 (b) Re-closer ANSI code: 79 (c) cold pickup (d) Earth fault code 50G/51G (e) Phase under current ANSI code: 37 (f) Restricted earth fault ANSI code : 64 REF (g) Negative sequence overcurrents ANSI code : 46 (h) Fault recording (i) Event recording (j) Disturbance Recording (k) Trip circuit supervision ANSI code : TCS (l) 4 analog input, 8 DI & 8 DO
Supply, installation and testing in replacements of Microprocessor Based, transformer differential Relay draw out type suitable for HT Panel comprising of new and modern numerical scheme for detecting, indicating and tripping the breaker on faults of differential current, over-current and earth-fault in any of the three phases of transformer, Trip circuit supervision relay of Make Schnider Micom P63X or equivalent in ABB/Siemens. The relay shall also have SCADA communication flush mounted on the RTCC 33 KV control the following features as minimum; (i) Programmable rated current 1A, 5A & DC 48 Volt (ii) Last 8 fault record & 200 event record with time stamping, (iii) 4 analog input, 8 DI & 8 DO, (iv) Communicable on IEC61850 protocol, (v) Disturbance recording upto 300 cycles, (vi) Self supervision function. (vii) Phase current differntial protection (viii) Three phase Non directional/Directional overcurrent protection (ix) Earth fault protection (x) Undercurrent
(xi) Transient Overreach and overshoot (xii) Thermal overload (xiii) Direct transfer trip and inter relay command transfer (xiv) Permissive intertrip (xv) Protection signalling channel, Dual redundancy, channel failure, propagation time check and error statistics (xvi)Comatibility with external interfaces Note:- Rate quoted includes the cost of configuration, testing & setting of the trip timing required as per the site condition.
S&F in replacement of main Bus spout for Areva/Alstom/CG make, complete suitable for 11 KV HT VCB of capacity 400 Amps with female contact, epoxy insulated body, locking/ connect nuts along with fixing accessories complete all as specified and as directed.
S&F in replacement of main Bus spout for Areva/Alstom/CG make, complete suitable for 11 KV HT VCB of capacity 630 Amps with female contact, epoxy insulated body, locking/ connect nuts along with fixing accessories complete all as specified and as directed.
S&F in replacement of circuit male with female contact spout for Areva/Alstom/ CG complete suitable for 11 KV HT VCB of capacity 400/630/800 Amps complete all as specified and as directed.
Supply and fix in replacement triping coil assembly 24/50/110 Volt DC for 11 KV HT VCB of capacity 400/630/800 Amps capacity all as specified and as directed.
Supply and fix in replacement closing coil assembly 24/50/110 volts DC for 11 KV HT VCB of capacity 400/630/800 Amps capacity all as specified and as directed.
Supply and fix in replacement auxillary switch (7 No + 7NC) for HT V.C.B 12KV 400/630/800 Amps capacity complete all as specified and as directed.
Supply and fix in replacement spring charging motor with spun/worm gear assembly type 220 Volt AC motorised mechanism of 11 KV VCB including testing & puting on load complete all as specified & as directed and suitable for VCB of make CG/Seimens/Aeva/ABB/Crompton/L&T.
Supply and fix in replacement of LED indication lamp for breaker ON/OFF/TRIP/Breaker Spring Charged/R-Y-B etc in HT 11 KV VCB panel including associated wiring, if reqd, complete all as specified and as directed.
Supply and fix in replacement Bus supporting epoxy insulators with fixing nuts & bolts with washer on both ends complete all as specified and as directed.
Supply and fix in replacement Digital Ampere meter 0-300 Amps in HT 11 KV VCB panel working on auxilary supply of 110V DC/ 220V AC including associated wiring, if reqd, complete all as specified and as directed.
Supply and fix in replacement Digital volt meter 0-15 KV in HT 11 KV VCB panel working on auxilary supply of 110V including associated wiring, if reqd, complete all as specified and as directed.
Supply and fix in replacement T&C Switch for Breaker ON/OFF purpose in HT 11 KV VCB panel including associated wiring, if reqd, for proper functioning of switch complete all as specified and as directed.
Supply and fix in replacement vacuum interrupter (3 inch/4 inch dia) WL type suitable for 11 KV VCB 630 Amps including testing & puting on load complete all as specified & directed for the VCB of make Crompton/ABB/Siemens/L&T.
Material & labour for complete replacement of the epoxy body of the Areva/Alstom/ CG 11 kv VCB 400/630 A along with new epoxy body of similar rating & model , epoxy insulators supporting insulator & circuit / Bus connections complete all as specified and directed.
Supply and fix in replacements PT unit three phase three limb upto 11 KV draw out type single ratio having primary 11 KV & secondary 110 volts, 200 VA class I, including necessary bus bar connection & wiring for metering after disconnecting of HT supply from HT VCB of any capacity for repair works, taking out unserviceable PT unit complete all as specified and as directed .
Supply and fix in replacement of HT 11 KV current transformer double wound cast resin type of ratio 200/100/5+5 Amps suitable for metering and protection, 26.3 KA/1 Sec, accuracy class 0.5, 5P10 including associated wiring complete all as specified and as directed.
Supply and fix in replacement of HT 11 KV current transformer double wound cast resin type of ratio 100/50/5+5 Amps suitable for metering and protection, 26.3 KA/1 Sec, accuracy class 0.5, 5P10 including associated wiring complete all as specified and as directed.
Supply and fix in replacements Digital Multifunction Meter with Multi Display for all basic parameters, power, energy, pf, max demand, etc and RS-485 port for ModBus communication in existing HT 11 KV VCB panel including associated wiring complete all as specified and as directed.
M&L for disconnecting power supply from HT load break switch of cap 200/400 Amps for repair works, taking out trolly unit & complete servicing of the same through decarbonising, cleaning the male /female isolating contacts, lubricating moving parts, cleaning with CRC, removing dust particles from bus bar chamber, spout gear mechanism and moving parts, repair to motor charge spring mechanism, tightening all nuts and bolts of entire trolley, checking proper operation of trolly, inserting trolley inside, testing, and putting on load complete all as specified and as directed.
M&L for marking to the transformers with black strip of size 300 mm x 250 mm and writing the details such as SM/MES No, Srl No & Capcity in white paint on the transformer complete all as specified and as directed.
M&L for Laminated paper sticker of letter size 250 mm x 8 mm in Red/Black/ white colour and printing of SM/MES No/feeder name/CT ratio etc as provided by AGE (U) E/S No-III in black colour and pasting the same on HT/LT panels complete all as specified and as directed. Note:- Each sticker shall have different printing matter.
S&F in replacements of earth continuity conductor or main earthing lead fixed on wall or recess or chases or buried in ground or drawn in conduit/pipe or fixed on poles or any other situation for loop earthing etc as required of size 32 x 6 mm galvanized iron strip incl necessary cutting chases, excavation, nut bolts etc incl dismantling old strip complete all as specified and as directed.
Supply & fixing in replacement of Air circuit breaker 4 pole 800 Amps 50 KA with microprocesser based fixed type , manual operated including dismantling & taking out old unserviceable ACB from panels & fabrication works to BUS bar for proper fitting complete all as specified and as directed.
Supply & fixing in replacement of Air circuit breaker 4 pole 1000 Amps 50 KA with microprocesser based draw out type , manual operated including dismantling & taking out old unserviceable ACB from panels & fabrication works to BUS bar for proper fitting complete all as specified and as directed.
Supply & fixing in replacement of Air circuit breaker 4 pole 1250 Amps 50 KA with microprocesser based draw out type , Manual operated including dismantling & taking out old unserviceable ACB from panels & fabrication works to BUS bar for proper fitting complete all as specified and as directed.
Supply and installation in replacement Anti-condensation space-heater withThermostatic in circuit breaker compartments of HT switchgears complete all as specified and as directed.
Taking out of heavy duty cooling fan ,3 phase, 50 Hz of size 24" from power transformer 33/11 KV of capacity 8/10 MVA ,servicing of the fan by opening including cleaning, greasing , replacement of defective spares parts such as bearing/ bushing, capacitor, canopy, clamp etc with new one and painting of fan body with synthetic enamel paint and re-assembling in same position after repairs and testing complete all as specified and as directed. (a) The cost of spare parts deemed to be included in quoted rates . (b) Rewinding of the fan will be measured and paid separately under respective item of this BOQ
M&L in replacements for Rewinding of heavy duty cooling fan, 3 phase, 50 Hz of size 24" of power transformer 33/11 KV capacity with super enamelled copper wire as per existing gauge including heating, varnishing, etc complete all as specified and as directed.
All as per item No 110 here-in before but of size 18"
S & F in replacement of hooter complete complete with switch etc suitable for warming HT 11 KV VCBs internal chambers complete all as specified and as directed.
S&F in replacements Identification plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures showing the details of 11KV feeder and fixed with M S clamps, bolts and nuts of approved size complete all as specified and as directed.
S & F in replacement maintenance free battery 12V, DC, 150 AH complete all as specified and as directed.
S & F in replacements MCB Single pole 6 Amps complete all as specified and as directed.
S & F in replacements MCB Double pole 6-32 Amps complete all as specified and as directed.
Repair to HT 11 KV four pole structure of 11 meter height Steel/RCC poles including replacement of all perished ACSR conductor (Beaver) of Horizontal bus bar and down conductors for 4 Nos. GOD system on structure, jumpering and binding with aluminium conductor to the post insulators/pin insulators and providning PVC sleeves to the down conductor with colour code R, Y&B, replacing all rusted nuts & bolts on the four pole structure complete all as specified and as directed.
All as per above item No. 117 here in before but for two pole strtucture complete all as specified and as directed.
M & L for taking down HT 11 KV grade tripple pole gange operated Air break switch from 4 pole/2 pole structure and S & F NEW gang operated Air break switch (GOD) HT 11 KV of 200 A capacity out door type suitable for vertical/horizantal mounting fixed type complete with 3 no. silicon rubber polymeric insulator per phase complete all as specified and as directed.
M&L for re-painting of HT 11 KV VCB panel/Bus Coupler of approx size 4 to 6 Sqm with 2 coats of super enamal paint over a coat of red-oxide with sparygun including writing of Inoming/outgoing/Bus cupller Name/numbers in appropriate size of letters complete all as specified and as directed.
S&F in replacement of 33 KV 50 Hz PT IS code 3156/1992 complete all as specified and as directed of specifications as under :- (a) Single phase, oil filled, self cooled, hermetically sealed, outdoor type. (b) Ratio (33/√3)/(110/√3) (c) As per IS: 3156 or equivalent IEC (d) Solidly earthed (e) Highest System Voltage (KV rms) 36 KV (f) Copper windings (g) Creepage factor (Max.) 4.0 (h) Nos of Lt winding 2 (i) Metering Core Accuracy class - 0.5 (j) Metering Core Rated Burden- 50 VA (k) Nos of Phase- Single (Earthed Type) (l) Protection core accuracy class - 3P (m) Protection core rated Burden - 50 VA (n) Rated Voltage Factor - 1.2 continuous & 1.5 for 30 Sec (o) Insulation Level- 36/70 KV.170 KVP (p) Temp rise at rated contineous thermal current over ambient at site - 50 degree C
S&F in replacement of PG clamps aluminium cast alloy suitable for ACSR conductor suitable for (weasel / panther ) for straight connections/ cross / t connections of type( as per conductor) 33 kv yard with GI nuts, bolts etc complete all as specified and as directed.
Material and labour for Preparation of old painted surfaces Including all safety measures of 33 KV yard Shankar Vihar site including all steel structures/ frame/gate of bus bay at Grid at an height of 10 mtrs to 15 mtr from GL consisting for 5 nos isolator per bay CT and PT and VCB supporting structure by brushing/cleaning stains, greasy spots with thinner, applying two coats of spray painting of existing colour (synthetic enamel paint) with spray machine in the yard complete all as specified and directed.
M&L for replacement of aluminium jumper made of ACSR conductor of type Dog / Panther / of size not less than 1 mtr of length conductor of 33 KV yard complete all as specified and as directed.
Material and labour for Preparation of old painted surfaces of fencing of 33 KV yard shankar vihar grid by brushing/cleaning stains, greasy spots with thinner, applying two coats of synthetic enamel paint of existing colour in the yard complete all as specified and as directed.
S&F of Switch Disconnector Fuse units of 630Amp TPN open executive type in existing main LT Panels at VIKRAM VIHAR and Shnkar Vihar complete all as specified and as directed.
Dismantling taking down 11 KV load break switch outdoor type and supply, installation , testing and commissioning of 11 KV, 400 Amps, 21 KA/3 sec outdoor type Ring main unit IP 54 protection plug in type extensible on one side SF 6 gas insulated one incoming and one outgoing (2 way ) with metering plate form mounted compact switch gear consisting of 01 Nos load break switch as incommer and 01 Nos outgoing VCBs , all live parts, bus bars VCB will be enclosed in robotically/manual welded minimum 2 mm thick stainless steel tank filled with SF 6 gas IP 67 Degree of protection and tested for internal arc 20 KA/1 sec as per latest IEC 62271-200 complete installed at basement of building, including the cost of PCC foundation for placing of RMU on plinth complete all as specified and as directed. The unit shall include the following with all necessary standard fitting required at site.
(A) Incoming Load Break Module - 01 Nos each switching unit shall be designed as a three position switch. This three function switch combines the functions of switch disconnector and earthing switch cables switch 12 KV, 400 Amp, 21 KA - 01 Set. Snap action mechanism for motorised and manual(Both) operation with integrated earthing switch switch - 01 Nos. Cable bushing 400 Amp standard C bushing - 01. Fault passage indicator, On(N-1) load break switch where n= no of load break switch >>s/c & E/F FPI with digital display to be added for detection of cable fault. ON, OFF, EARTH mechanical indication on the front mimic of the panel - 01. Capacitive voltage indication fixed type LED display - 01. ON, OFF, TRIP mechanical indication on the front mimic of the panel - 01. Cable box for termination of cable up to 1 No. x 185 sq.mm - 01. Cable cover standard - 01. Set of 12kV Cable Termination Boots - 01. Cable entry bottom, front - 01
(B) (i) Out going VCBs - 01 No consisting of following - function unit consist of vaccum circuit breaker in combination with a three position switch. The three position switch fulfills the operation of the disconnector function and earthing function circuits breaker unit is equipped with an over current transformer for the protection of distribution Transformer/circuit vaccum circuit breaker 12 KV, not less than 400 A, 21 KA - 01. Spring assisted closing with stored Energy triping mechanism for motorised operation with integrated earthing switch - 01. live cable LED indicators thru capacitor voltage dividers mounted on the bushings push button for breaker trip - 01 sec O/C + E/F self powered numerical protection relay with low and High set for Over current and earth fault Relay should have facility to display the maximum loaded phase current also current also relay shall record minimum 5 fault records with time stamping - 01 Alaram trip indication 6 window anuciator for transformer faults Mechanical ON/OFF/EARTH indication -01.
Auxliary contacts on load switch are 1 No+2NC & Auxiliary conract on earth switch is 1 No+ 1NC-01. Self powered electronic numerical protection relay providing 3 over-currents & 1 E/F protection - 01, shunt trip coil 24 V DC-01 capactive voltage indication fixed type LED display -01 ON/OFF/Trip mechanical indication on the front mimic of panel-01 cable box for termination boots-01. Metering Equipment incl. 01 x Digital Voltmeter (Acc.Cl.0.5), 01 x Digital Ammeter (Acc.Cl.0.5), 01 x Tri-VectorMeter (Acc.Cl.0.5) Auxliary relay for transformer protection -06 Nos.
(B) (ii) Out going VCBs - 01 No, each consisting of CT 100/1 -5p10.2.5VA- 03 Nos. "(C ) Additional equipment deliverd separately or mounted separately, Bus connected with battery charger and battries for motor power supply-01 (i) PT ratio 11KV/3/110/v3, 100 va, 0.5 class for measurement with volts meter (ii) Auxliary transformer of 11KV/230V, 1 KVA for powering the motors and battery charger (iii ) 24 V DC battery charger and battries for motor power supply. Standard mano meter -01, Operating handle - 02 , cable clamping provision(standard)-01 Operation and maintance manual - o1, installation and commissioning manual - 01, cost of PCC works for placing RMU on plinth is deemed to be included in the cost, Height of plinth shouldnot be less than 0.45 mtrs from ground level. NOTE :- (a)The above module consisting of one Load break Switch and 01 VCBs shall be alligned appropriately and must have electrical and mechanical interlocking as per latest electrical safety norms including foundation complete.
Supply and fix in replacement of 630/800A Breaker Bushing for tulip contact for HWX/VMX 11KV Breakers complete all as specified and as directed.
Supply and fix in replacement of 630/800A Breaker Bushing for socket contact for HWX/VMX 11KV Breakers acomplete all as specified and as directed.
Supply and fix in replacement of 630/800A Breaker spider for HWX/VMX 11KV Breakerscomplete all as specified and as directed.
Supply and fix in replacement of 630/800A Breaker Drive insulator with M10 Nyloc Nut complete all as specified and as directed.
Supply and fix in replacement of Isolating Socket- 1250A of 11 KV breakercomplete all as specified and as directed.
Supply and fix in replacement of Shunt Trip coil both 24 volt DC ( OG 835) and 110 volt DC (OG 838) complete all as specified and as directed.
Supply and fix in replacement of Motor charge spring mechanism ( SPMX Form AM) with coils ( mention trip, close & motor voltage) of 11 KV Breaker complete all as specified and as directed.
Supplying, laying, testing and connecting XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 33 KV (E) grade, of size 300 Sq mm, 3 core, laid in trenches/duct/encased in GI pipe/fixed to pole, complete by taking down/out the old unserviceable cable all as specified & as directed. Note : Excavation, Earth work, Cable protection, sand filling and Cable Joints shall be measured and paid separately in respective items of this BOQ.
Supply and fix Cable jointing kit for 33 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 300 Sqmm complete by taking down/out old unserviceable cable joint all as specified & as directed.
Vijay Electricals
SANJEEV ENTERPRISES
mayur enterprises
Water Power Engg. Enterprises
Buddham Builders
M P TYAGI ENGINEERS AND CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .