Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.3 LAccepted-AOC 368 PHASE 4 SAS NAGAR MOHALI 160059 PB | MOHALI | SAS NAGAR | PUNJAB | 160059 | L1 | Accepted-AOC L1 QUOTED | |
| 2 | L2₹30.1 L+₹4.7 L (18.3%)Rejected-AOC HM 324 PHASE IX SAS NAGAR MOHALI PB | L2 | Rejected-AOC L2 QUOTED |
Tender Value
₹30.8 L
EMD Value
₹61,500
Closing Date
10 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Chandigarh
GE AF Chandigarh PIN-160003 C/o 56 APO
IMPROVEMENT OF RUNWAY CONTROLLER HUT INCLUDING ALLIED WORKS AND CERTAIN MINOR WORKS AT AF STATION CHANDIGARH
2024_MES_637034_1
GE(AF)/CHD/T-53/2023-24
Open Tender
Civil Works
Item Rate
183 days
Chandigarh
All as per NIT and Tender documents
10 documents required · 10 mandatory
₹500
GE AF Chandigarh
₹61,500
Yes
31 Mar 2024
11 Jan 2024
17 Feb 2024
11 Jan 2024
10 Feb 2024
27 Jan 2024
11 Jan 2024 - 18 Jan 2024
Amount
Note :The unit rate quoted by the tenderer under Col No (13) of Sch `A’ (BOQ) unless specifically mentioned otherwise such as labour only/fixing only, for all items of works shall be deemed to be including cost of all materials, labour, tools and plants, testing and commissioning of work in position complete as required for entire completion of work.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loosec soil including removing excavated soil to a distance exceeding 250 metre but not exceeding 500 metre and depositing where directed at a level not exceeding 1.50 meter above the starting point , complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches in soft/loosec soil , not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out, complete all as specified and directed by Engrineer-in-Charge.
Removing excavated soil to a distance exceeding 250 metre but not exceeding 500 metre and depositing where directed at a level not exceeding 1.50 meter above the starting point , complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested, complete all as specified and directed by Engineer-in-Charge.
Hardcore of gauge n exc. 63 mm of broken stone , deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface , complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete (1:5:10), type E-2, using 40 mm graded mechanically crushed stone aggregates as in sub base ,foundations, filling and mass concrete , complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete 100 mm thick,(1:4:8), type D-2, using 40 mm graded mechanically crushed stone aggregates as in sub base ,foundations, filling and mass concrete , complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete ,75 mm thick (1:4:8) type D-2, using 40 mm graded mechanically crushed stone aggregatesd aggregate as in sub base / Floor, complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete 75 mm thick, 1:3:6, type C-2, using 40 mm graded mechanically crushed stone aggregates, laid in 1:20 slope as in plinth protection including making joints at 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/ 25 & two parts heated sand (by volume), surface finished even and fair ,complete all as specified and directed by Engineer-in-Charge. Note :Quoted rates are inclusive of use and waste of formwork and to devide the area in panels.
Plain cement concrete ,(1:3:6) type C-2, using 40 mm graded mechanically crushed stone aggregatesd aggregate as in sub base /base of post ,complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete ,75 mm thick (1:3:6) type C-2, using 40 mm graded mechanically crushed stone aggregatesd aggregate as in sub base , complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete ,75 mm thick (1:2:4) type B-2, using 40 mm graded mechanically crushed stone aggregatesd aggregate as in sub base , complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete (1:2:4) type B-0 using 12.5 mm graded mechanically crushed stone aggregates 40 mm thick as in Damp proof course to horizontal or vertical surfcaces including necessary form work , complete all as specified and directed by Engineer-in-Charge.
Demolition of brickwork or stone boulder masonary built in cement mortar including all quoins, arches, pillars etc for the area where unservicable bricks retrived and removal of rubbish outside MoD land , complete all as specified and directed by Engineer-in-Charge.
Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 , complete all as specified and directed by Engineer-in-Charge.
Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:4 , complete all as specified and directed by Engineer-in-Charge.
Brick work with sub-class `B' bricks, straight or curved on plan in any radius in half brick thick wall built in cement sand mortar 1:4 ,complete all as specified and as directed by Engineer -in-Charge.
Use & waste of for formwork to floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs,etc. also splays between floors and beams, etc for rough finished surfaces of concrete,complete all as specified and as directed by Engineer -in-Charge.
Use & waste of form work to soffits of suspended slab of concrete such as roof slabs, floor slabs, cover slab, shelve, landings and similar works n.exc 200 mm thick (horizontal or sloping); for rough finished surfaces of concrete flat surface, complete all as specified and directed by the Engineer in Charge.
Use & waste of form work to chullah hoods, cha jjas, troughs and similar items including edges for rough finished surfaces of concrete,complete all as specified and as directed by Engineer -in-Charge.
Mild steel TMT bars 10 mm dia and over as in reinforcement cut to length , bent to shape required, including cranking, bending spirally for hooping ends for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.90 mm dia, complete all as specified and directed by the Engineer in Charge.
Mild steel TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90 mm dia. or higher , complete all as specified and directed by the Engineer in Charge.
Reinforced Cement concrete M-25 ( Design mix), using 20mm graded crushed stone aggregate Beams, cantilevers, bressummers , lintels over 1.5m span, complete all as specified and directed by Engineer-in-Charge. Note: Steel reinforcement shall be measured and paid for separetely.
Reinforced Cement concrete M-25 ( Design mix) ,using 20mm graded crushed stone aggregate as in chajjas, complete all as specified and directed by Engineer-in-Charge. Note: Steel reinforcement shall be measured and paid for separetely.
Reinforced Cement concrete M-25 ( Design mix) type B1 using 20mm graded crushed stone aggregate as in slabs supported on wall beam and column in floor slabs and roofs landing deck slabs and in shelves , complete all as specified and directed by Engineer-in-Charge. Note: Steel reinforcement shall be measured and paid for separetely.
Taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, and removing of rubbish outside MoD land , complete all as specified and directed by Engineer-in-Charge.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished the surface even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
Rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 finished the surface even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
Rendering 5 mm thick on fair faces of concrete surfaces of ceiling in cement mortar 1:3 finished the surface even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
Rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 finished the surface even and smooth without using extra cement and mixing with water proofing compound as per manufacturers instruction @3% of cement weight , complete all as specified and directed by Engineer-in-Charge. Note: Quoted Rate of above item is inclusive the cost of WPC and nothing extra shall be admissible on this account.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished the surfaces even and fair without using extra cement and mixing with water proofing compound as per manufacturers instruction @3% of cement weight , complete all as specified and directed by Engineer-in-Charge. Note: Quoted Rate of above item is inclusive the cost of WPC and nothing extra shall be admissible on this account.
Preparation of new plastered or unplastered surfaces of walls and applying three coats of white washing , complete all as specified and directed by Engineer-in-Charge.
Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white washing , complete all as specified and directed by Engineer-in-Charge.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper including priming with alkali resistant priming paint preparatory to distempering , complete all as specified and directed by Engineer-in-Charge.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint over a coat of primer on walls, complete all as specified and directed by Engineer-in-Charge.
First quality glazed designer pattern ceramic coloured tiles of 300x450x7 mm thick fixed in pattern to wall ( combination of dark and light colour with boarder) laid on vertical surfaces such as skirting, dados and risers to steps etc laid over and including 10mm thick cement plaster in CM (1:3) set and jointed in neat cement paste of honey like consistancy and pointed in white or coloured cement to match the shade of tiles, complete all as specified and directed by Engineer-in-Charge. Note :- Design, pattern and colour of tiles will be as approved by GE. Quoted rates are inclusive of any no of Highlighters required for making pattern .
First quality glazed designer pattern ceramic coloured tiles of 300x450x7 mm thick fixed in pattern to wall ( combination of dark and light colour with boarder) laid on vertical surfaces such as skirting, dados and risers to steps etc laid over and including 10mm thick cement plaster in CM (1:3) set and jointed in neat cement paste of honey like consistancy and pointed in white or coloured cement to match the shade of tiles in and including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off the premises, complete all as specified and directed by the Engineer in Charge. Note :- Design, pattern and colour of tiles will be as approved by GE. Quoted rates are inclusive of any no of Highlighters required for making pattern .
First quality, Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sq.m but not exceeding 0.18 Sq.m, laid in floors with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:4) including pointing in white or coloured cement to match the shade of tiles , complete all as specified and directed by the Engineer in Charge. Note :- Design, pattern and colour of tiles will be as approved by GE.
First quality, Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sq.m but not exceeding 0.38 Sq.m, laid in floors with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:4) including pointing in white or coloured cement to match the shade of tiles in and including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off the premises, complete all as specified and directed by the Engineer in Charge. Note :- Design, pattern and colour of tiles will be as approved by GE.
Granite black/brown colour (any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding ,moulding and polishing and laid over 15mm thick screed bed in CM 1:4 in and including demolition of stone slab and tiles of any description or thickness in floors, aprons etc, laid bedded and pointed in white cement with pigment,complete all as specified and directed by Engineer-in- Charge.
Granite black/browncolour (any type) tiles 20mm thick tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete and laid over 10mm thick screed bed in CM 1:3 in and including demolition of stone slab and tiles of any description or thickness in floors, aprons etc, laid bedded and pointed in white cement with pigment,complete all as specified and directed by Engineer-in- Charge.
Providing and laying 60mm thick factory made machine pressed interlocking paver block of M-35 grade of any shape and size confirming to IS 15658-2006 with grey cement and pigment laid over and including 25 mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra , complete all as specified and directed by Engineer-in-Charge. Note : Quoted rates are inclusive of fine sand and nothing extra shall be admissible on this account.
Taking down Chowkhats with shutters without taking of shutter from the frame of any description not exceeding 1.50 Sq. m each, and making good the disturbed surface in CM 1:4 & finished with similar specification as exists, complete all as specified and as directed by the Engineer-in-Charge.
Taking down Chowkhats with shutters without taking of shutter from the frame of any description exceeding 1.50 Sq. m but not exceeding 4.00 Sq. m each, and making good the disturbed surface in CM 1:4 & finished with similar specification as exists, complete all as specified and as directed by the Engineer-in-Charge.
Factory made solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplied and fitted as per specification & drawing and as per manufacturer's instructions and shown on drawing on Page 160 of SSR Pt-II ,complete all as specified and directed by the Engineer in Charge.
Factory made solid panel PVC door shutters 30 mm thick (style) consisting of frame made out of MS tube for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for style and plain colour PVC sheets for top rail, lock rail and bottom rail on either sides & as gap insert for top- rail and bottom rails. Paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement supplying and fixing in the frame at site as per specification and drawing ,complete all as specified and directed by Engineer-in- Charge.
Anodised aluminium frame for doors, windows,ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and as directed by Engineer-in- Charge.
Aluminium Anodised door shutter, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips rubber neoprene packing , Handle 2 Nos in each door, 3 hinges, anodised aluminium snap beading screw etc for fixing of Glass or baord , complete all as specified and directed by Engineer-in-Charge Note: Supplying and fixing of Glass or board shall be measured and paid seperately under respective items.
Anodised aluminium window and ventilator shutters,without sash bar,aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc, complete all as specified and directed by Engineer-in-Charge. Note: Supplying and fixing of Glass or board shall be measured and paid seperately under respective items.
Pre-laminated particle board 9mm thick , interior grade, pre-laminated both side with decorative choice laminaton fixed with screws to timber frame work, as in doors or partitions, complete all as specified and directed by Engineer-in-Charge
Toughened high strength sound proof glass 18 mm thick ,coushioning of two layer of glass sheet outer side of 12mm and 10mm vacume and 2nd layer of 6mm thick glass fixed in slant position and fixrd with aluminium galzing clips, rubber neoprene packing aluminium snap beading screw etc.,complete all as specified and directed by Engineer-in-Charge.
Factory made steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welde ,complete all as specified and directed by the Engineer in Charge.
Factory made steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded ,complete all as specified and directed by the Engineer in Charge.
Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm in steel window clips and wooden beading in wooden joinery ,complete all as specified and directed by Engineer-in- Charge.
Sheet glass 3 mm thick, ordinary quality and glazing with oil putty or wooden bead in squares not exceeding 0.5 Sq. m in each pane ,complete all as specified and directed by Engineer-in- Charge.
Butt hinges 100 mm size ,extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed type C21 ,complete all as specified and directed by the Engineer in Charge.
Barrel tower bolts aluminum anodizes of extuded section and fixed of 200 mm long size (length of bolt), complete all as specified and directed by Engineer-in-Charge
Handles of size 150 mm ,extruded aluminium alloy , fabricated type anodized ,complete all as specified and directed by Engineer-in- Charge.
Aluminum alloy, anodized, sliding door bolt with hasp staple ( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed length of bolt 250mm, bolts not less than 12mm dia with and including a minimum of 6 bolts not,four on bolt plate and two on staple plate complete (ISI marked ) , complete all as specified and directed by Engineer-in-Charge.
Butt hinges medium weight (ISI Marked) cold rolled mild steel and fixed of size of hinges100 mm ,complete all as specified and directed by the Engineer in Charge.
Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixe of 150 mm long size (length of bolt), complete all as specified and directed by Engineer-in-Charge
Mild steel pressed handles of size 150 mm, oval type, stove enamelled black ,complete all as specified and directed by Engineer-in- Charge.
Mild steel sliding door bolts,plate type, stove enamelled black, and fixed length of bolt 250mm with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed (ISI marked ) , complete all as specified and directed by Engineer-in-Charge.
Aluminium body ( extruded section ) Door closer hydraulically regulated, designation No. 3 , universal type , suitable for door shutters 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed as in repair , complete all as specified and directed by Engineer -in-charge.
Mortice lock of size 100 mm aluminium, verticle type brass 4 Levers , complete all as specified and directed by Engineer-in-Charge.
M S work as Framed works such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes,framed guard bars barred iron doors ladders, framed balusters walk ways railing, framed work of water tanks, framed and hung as gates including pintle hinges, stops, hand made sliding sliding bolts etc ,cdrilling bolting or reveting etc and similar work conforming Fe-290 Gde E-165, complete all as specified and directed by Engineer-in- Charge.
Venation blind roller type including all fittings,complete all as specified and directed by Engineer-in- Charge.
Steel water tubing, 15 mm bore medium grade ISI Marked, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors, fixed, complete all as specified and directed by Engineer-in-Charge. Note: Fittings & specials as required shall be provided by the contractor. Contractor's rate shall be deemed to include the cost of fittings provided.
Steel water tubing, 20 mm bore medium grade ISI Marked , galvanized with all fittings and fixed complete to walls, ceiling or laid in floors, fixed ,complete all as specified and directed by Engineer-in-Charge. Note: Fittings & specials as required shall be provided by the contractor. Contractor's rate shall be deemed to include the cost of fittings provided.
Rotational moulded PVC, tripple layered, water storage tanks of capacity 500 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, with & including all fittings such as GI tank nipple etc. but excluding ball valve, complete all as specified and directed by the Engineer in -Charge.
Ball brass valve of 20 mm bore,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed , complete all as specified and directed by Engineer-in-Charge.
Salt-glazed stoneware gully traps, square or round mouthed, tvpe 'P of size 150mmx150 mm, complete all as specified and directed by the Engineer in -Charge. Notes : (i) The quoted rate of this item is deemed to be included the setting and jointing to drains with cement mortar 1:1. (ii) All excavation and earthwork, concrete in beds, surrounds, kerbs, etc. and cast iron grating, shall be measured and paid separately.
Gratings doom of PTMT 100 mm dia with waste hole fixed on floor /nahani traps with cement mortar (Minimum weight 25 gms), complete all as specified and directed by Engineer-in-Charge.
Gratings doom of PTMT 125 mm dia with waste hole fixed on floor /nahani traps with cement mortar (Minimum weight 40 gms), complete all as specified and directed by Engineer-in-Charge.
Shelf of PTMT fixed with and including Chromium plated brass screws and wooden / platic cleats (minimum weight 300gms), complete all as specified and directed by Engineer-in-Charge.
Liquid soap container of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 105gms) , complete all as specified and directed by Engineer-in-Charge.
Waste fittings 32 mm, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end , complete all as specified and directed by the Engineer in -Charge.
Angle valves, 15 mm bore chromium plated cast copper alloy, screwed down,high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed , complete all as specified and directed by Engineer-in-Charge.
Stop valves, 15 mm bore fancy type chromium plated cast copper alloy, screwed down,high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed , complete all as specified and directed by Engineer-in-Charge.
Stop valves, 20 mm bore cast copper alloy, screwed down,high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed , complete all as specified and directed by Engineer-in-Charge.
Bib taps,15 mm bore fancy type chromium plated long body cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed , complete all as specified and directed by Engineer-in-Charge.
Pillar taps, fancy type cast copper alloy , with capstan heads, chromium plated , screwed down for 15 mm bore pipe,high pressure , with or without l'ettered ' 'HOT' or 'COLD' with long screwed shanks and fly-nuts , screwed for iron pipe fixed , complete all as specified and directed by the Engineer in -Charge.
Wash basins , vitreous china, white, flat back of size 550x400 mm including cutting for and pinning in ends in brackets or erecting stand and including new M S brackets ,complete all as specified and directed by Engineer-in- Charge.
Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including connection to trap,and to flushing pipe, anti-syphonage pipe,etc.in and including plastic water closet seat, white, closed pattern with flat bottom , and cover and mild steel chromium plated or aluminised hinging device complete including making good to floor , complete all as specified and as directed by the Engineer-in-Charge. Note :- Qty and Rates are inclusive of for both P type and S type Traps as on actual required basis on ground
PVC valveless , syphonic action type flushing cisterns 10 ltrs capacity , low level , white, with inlet ball valves , float and handle including brackets and pvc flush pipe 32 mm dia for low level , complete all as specified and directed by the Engineer in -Charge
PVC connections 15mm size with PTMT nuts of length 450mm , complete all as specified and directed by Engineer-in-Charge.
Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges , complete all as specified and directed by the Engineer in Charge.
Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum),with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws pointing around urinal back in cement including 32 mm Waste coupling of PTMT (half or full threaded) suitable for urinals , complete all as specified and directed by the Engineer in -Charge.
PVC (SWR) pipes 110mm bore single socketed in any length with ruber rings joints laid in trenches or in floor ,complete all as specified and directed by Engineer-in- Charge.
PVC (SWR) pipes 75 mm bore single socketed in any length with ruber rings joints laid in trenches or in floor ,complete all as specified and directed by Engineer-in- Charge.
PVC (SWR) pipes 75 mm bore single socketed in any length with ruber rings joints fixed to walls with necessary brackets and making good the mouth of rain water pipe ,complete all as specified and directed by Engineer-in- Charge.
PVC (SWR) bends any radius 110mm bore fixed with solvent cement in any position as per site requirement , complete all as specified and directed by Engineer-in-Charge.
PVC (SWR) bends any radius 75mm bore fixed with solvent cement in any position as per site requirement , complete all as specified and directed by Engineer-in-Charge.
PVC (SWR) pipes 110mm bore junction single, (single Tee) equal or unequal with oval accesss door fixed with solvent cement in any position as per site requirement , complete all as specified and directed by Engineer-in-Charge.
PVC (SWR) pipes 75mm bore junction single, (single Tee) equal or unequal fixed with oval accesss door fixed with solvent cement in any position as per site requirement , complete all as specified and directed by Engineer-in-Charge.
PVC (SWR) vent cowl 110 mm bore fixed with solvent cement in any position as per site requirement , complete all as specified and directed by Engineer-in-Charge.
Gypsum partition interior wall of 85mm thickness (double layer boarding with 8mm thick proland providing and fixing system componenets, It includes fixing of frame , floor and ceiling channel (0.55mm thick, 52mm wide and having two flanges of 30mm each) to the RCC floor and slab with approved fasteners @ 600mm center to centre respectively . Frame wall studs (.055 mm thick , 50mm wide having one flange of 34mm another of 36 mm. these wall studs are placed at 610mm centre to centre in floor and ceiling channel. Double layered of 8mm thick. TUFFBLOCK boards is screw fixed vertically to either side of frame wall studs with 25mm long drywall screws at 300mm centre to centre. In the centre of the board there is layer of techsound 2.5mm for sound isolation , to stop the noise and inside the hallow cavity filled with the rockwool. The screws fixing of the board to the metal framing at the periphery, openings and cut edges should be at 150mm centre the horizontal and vertical jointof the tuff block boards on both sides of the metal frame work must be staggered so as to avoid through and through joints. MS fixing channel of 99 mm with (0.09mm thickhaving two flanges of 9.50mmEach) to be provided at the horizontal joints of two boards. fixed to the studs usingmetal to metal flat head screws. All joints to be taped and finished with 50mm wide paper tape & all proposed joint compound ,complete all as specified and directed by the Engineer in Charge. Notes: (i) All opening and cut shall be sealed with fire sealants as approved. (ii) All external 'L' Junction shall be finished with metal corner tape if required)
Cutting into walls of existing manholes for connecting new drain pipe 150 mm internal dia pipe, making good to wall in CM (1:3)/ PCC (1:2:4) after inserting pipe, cutting out benching & forming branch channel (1/2) round or (3/4 section) in cement concrete (1:2:4) type B-1, reforming benching as required and rendering smooth finished, including removal of rubbish outside MoD land, complete all as specified and directed by the Engineer-in-Charge.
Providing pre-cast reinforced cement concrete 1:2:4 type B-1, using 20 mm graded mechanically crushed stone aggregates set in cement mortar 1:4 as in manhole covers including necessary forms/moulds , complete all as specified and directed by Engineer-in-Charge. Note: Steel reinforcement shall be measured and paid for separetely.
Reinforced concrete pipes of dia 150 mm, class NP2, laid and jointed complete with collars, complete all as specified and directed by Engineer-in-Charge.
Salt- glazed stoneware drain pipe grade ‘A’ 150 mm bore, ISI marked jointed with cement mortar, laid in trenches and tested including pipe fittings such as bend, junction etc. of same grade , complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete 1:4:8, type D-2 (using 40mm graded stone aggregate) as in bed to SGSW/RCC hume pipes of 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed by the Engineer-in-Charge.
Construction of septic tank for 10 users with free board depth 0.45m including excavation and earth work in any type of soil, foundation in PCC 1:2:4, brick work in CM 1:4, RCC 1:2:4 type B-1 slab including CI manhole cover (HD) vent pipe and sludge chambers, returning filling in and depositing disposal soil to a distance not exceeding 50 metre, complete all as specified and directed by the Engineer-in-Charge.
Construction of Soakage wells, excavation in any type of soil, foundation in PCC 1:3:6 wells of honey combed and solid in M-25 concrete including intercepting chamber, screen chamber, Brick work in CM 1:4, RCC cover slab in M-25/ RR masonry/ filling with brick bats complete of size 1.20M dia x 3.00 M deep , complete all as specified and directed by the Engineer-in-Charge.
Excavation in post holes (or similar holes) each not exc. 0.5 Cum and getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc. 25 cm, watering and removing surplus spoil to a distance not exc. 50 m and making good surface in soft / loose soil , complete all as specified and directed by Engineer-in-Charge.
Mild Steel angle iron for post and flat iron, or other steel section or core for wooden hand-rail straight portion drilled including embedded in concrete and screwing etc., posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets (for scuring wire mesh etc). including all necessary drilling, bolting or riveting etc. and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed by Engineer-in- Charge. Note:- Earth work and concrete shall be measured and paid for separately under respective item of this schedule.
Supply olnly Chain MS galvanisd fencing, 4mm dia galvanised steel wire of mesh size 100x 100mm , fixed to MS post by means of screw to flat iron) , complete all as specified and directed by Engineer-in-Charge. Note:- Post shall be measured and paid under respective item of this schedule .
Fixing only chain link galvanised wire fencing of 4mm dia galvanised steel wire of mesh size 100x 100mm and both ends without knuckling/ twisting, fixed to flat iron rails with RCC/Angle iron post , complete all as specified and directed by Engineer-in-Charge. Note:- Supply of chain link and mild steel galvanised line wire shall be measured and paid separately under respective item of this schedule .
Mild steel screw bolt (machine made) factory made with hexagonal or square heads at one end and screwed the othe ,or screwed both ends,each screwed end to be fitted with washers and one hexagonal or square nut exc 5 cm but not exc 10 cm long and dia of neck 5 to 10 mm , complete all as specified and directed by Engineer-in-Charge.
Plain mild steel round bar 8 to 10mm dia, cut to length, bent to shape required, making hooks at ends, woven in chain link and fixed with nut and bolts, complete all as specified and directed by Engineer-in-Charge.
Preparation of new or previously untreated plastered surfaces of any description , not otherwise described over 10 cm width or girth and applying two coats of synthetic enamells paint over one coat of primer of Red and white in colour,complete all as specified and directed by the Engineer in Charge.
Preparation of old painted concrete surfaces of any description , not otherwise described over 10 cm width or girth and applying two coats of synthetic enamells paint ,complete all as specified and directed by the Engineer in Charge.
Preparation of new or previously untreated steel surfaces of any description , not otherwise described over 10 cm width or girth and applying two coats of synthetic enamells paint over one coat of red oxide primer,complete all as specified and directed by the Engineer in Charge.
Water proofing treatment on horizontal roof surfaces in the following manner complete all as specified and directed by the Engineer in Charge :- (a) Dismentling of existing roof treatment of any type including taking down existing bitumen felt as directed. (b) Cleaning of pastered or concrete surfaces of any description for preparation before water proofing treatment of roof horizontal surfaces (c) 15mm thick screed plaster on RCC slab in cement mortar 1:4 in and including using water proofing compound @ 3% by weight of cement. (d) The surfaces shall be painted with hot bitumen grade 30/40 confirming to IS-73 @ 1.20 kg/sqm over a coat of bituminous primer conforming to IS-3384 @ 0.30 ltr/sqm. (e) Providing with 3 mm thick APP water proofing membrane reinforced with non woven polyster matt laid using butane torch by torch application with a side lap of 10 cm & 15 cm end lap weinghing not less than 3.6 kg/sqm all as per manufacturer's instructions .
All as per Srl no. 115 here-in-before but on vertical surfaces, the surfaces shall be painted with hot bitumen grade 30/40 confirming to IS-73 @ 1.20 kg/sqm over a coat of bituminous primer conforming to IS-3384 @ 0.30 ltr/sqm. , complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete (1:2:4) type B-1 using 20 mm graded mechanically crushed stone aggregates as in coping /roof padding /roof kerb ior mud stop ,water through, benching and like icluding weathering slightly ropunded or chamfered angles and throating as directed including necessary form work , complete all as specified and directed by Engineer-in-Charge.
40mm thick brick tiles laid on and including15mm thick CM(1:6) using grey cement and grouted flush in CM (1:3) mixed with 5% of crude oil by weight of cement, laid on concrete roof in and including dismantling of brick tiles or terracing tiles, single layer on roofs, removal of serviceable tiles to store and rubbish off the permises., complete all as specified and directed by the Engineer in Charge
Cutting grooves in brick walls 75mm wide and 65mm deep for inserting APP membrane and shaping horizontal face of groove with cement mortar (1:3), removal the rubbish off the permises upto a distance not exceeding 50 mtrs , complete all as specified and directed by the Engineer in Charge
Cutting out cracks to V-section in existing RCC roofs or tarracing, cleaning out, wetting ,grouting with cement and sand slurry 1:3, complete all as specified and directed by the Engineer in Charge
Point wiring for one light point/fan point/bell point controlled by one switch one way drawn through and including non metalic rigid PVC conduit medium duty of suitable size with all strandard fittings such as Tee junction, bends etc ,using FRLS PVC unsheathed multistrand copper conductor cable of 1.5 sqmm single core including MS Sunken terminal boxes with mounting plates and cover plates suitable for modular switches/sockets and earth continuity insulated PVC unsheathed(green colour) 1.5 sqmm copper earth wire connected to common earth dolly and making good disturbed surfaces of walls, floors, etc. to match with the existing surfaces ,complete all as specified and as directed by Engineer-in- Charge. Note : Wiring shall be done by using proper colour coding.
All as per srl item No. 121 here-in-before but for 06 Amp socket outlet on independent board, complete all as specified and directed by Engineer-in-Charge. Note : Wiring shall be done by using proper colour coding.
All as per srl item No. 121 here-in-before but for 06 Amp socket outlet on same board, complete all as specified and directed by Engineer-in-Charge. Note : Wiring shall be done by using proper colour coding.
Point wiring for 16 amps socket point controlled by one, one way switch using drawn through and including non metalic rigid PVC conduit medium duty of suitable size with all strandard fittings such as Tee junction, bends etc ,using FRLS PVC unsheathed multistrand copper conductor cable of 2.5 sqmm single core including MS Sunken terminal boxes with mounting plates and cover plates suitable for modular switches/sockets and earth continuity insulated PVC unsheathed(green colour) 2.5 sqmm copper earth wire connected to common earth dolly and making good disturbed surfaces of walls, floors, etc. to match with the existing surfaces,complete all as specified and as directed by Engineer-in- Charge. Note : Wiring shall be done by using proper colour coding.
Moduler switch 1 way 6A, 1 modules square white mechanisms, complete all as specified and as directed by Engineer-in- Charge.
Moduler switch 1 way 16A, 1 modules square white mechanisms, complete all as specified and as directed by Engineer-in- Charge.
Moduler socket 6 Amps, 2/3 Pin combined, 2 module, complete all as specified and as directed by Engineer-in- Charge.
Moduler socket 6/16 Amps, 2/3 Pin combined, 2 module, complete all as specified and as directed by Engineer-in- Charge.
Wall mounted fan single phase 240 volts 400 mm sweep oscilating type with speed regulator , complete all as specified and as directed by Engineer-in- Charge.
LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose , complete all as specified and as directed by Engineer-in- Charge.
LED street light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including 25 mm dia GI medium grade pipe bracket bent to shape as directed & 90 cm long with and incl 02 Nos MS flat clamps of suitable size , complete all as specified and as directed by Engineer-in- Charge.
Portable lamp with dimmer and adjustable lamp , complete all as specified and as directed by Engineer-in- Charge.
LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including 40mm dia GI meduim grade pipe bracket bent to shape as directed 120cm long and including 02 Nos MS flat clamps nuts/ bolts/ washers etc of suitable size for steel tubular poles, complete all as specified and as directed by Engineer-in- Charge.
Taking out unserviceable cable from trenches of size 25 sqmm 4.0 core , complete all as specified and directed by Engineer-in- Charge.
LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 6 sqmm cross sectional area, 2.0 core ,laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers including jointing and testing , complete all as specified and directed by Engineer-in- Charge. Note : Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
All as per item No 135 here-in-before but size 25 sqmm 4.0 core , complete all as specified and as directed by Engineer-in- Charge. .
Sand cushioning to under ground cable with clean dry river sand in layer of sand 8cm thick before laying of cable and 15 cm after laying of cable, complete all as specified and directed by Engineer-in-Charge. Note- For payment purpose punned thickness of 18 cm shall be measured against spread thickness of 23 cm as mentioned in para 19.75 of SSR Part-I.
Protection of cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ bricks, complete all as specified and as directed by Engineer-in-Charge.
Steel water tubing, 40 mm bore light grade ISI marked galvanized with all fittings laid in trenches / road crossing/ fixed to pole /walls/path/drain /floor etc,compllete all as specified and as directed by Engineer-in-Charge. Note: Fittings & specials as required shall be provided by the contractor. Contractor's rate shall be deemed to include the cost of fittings provided.
Steel water tubing, 20 mm bore medium grade, galvanized with all fittings and laid in trenches ,complete all as specified and directed by Engineer-in-Charge. Note: Fittings & specials as required shall be provided by the contractor. Contractor's rate shall be deemed to include the cost of fittings provided.
Screwing existing steel tubing 20/25 mm dia for alterations or additions (or lengthening screw on pipe to form connector) done in position without taking down, complete all as specified and directed by Engineer-in-Charge.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure, complete all as specified and directed by Engineer-in-Charge.
Secondary Air field lightining cables as per IS:1554 (Part-II) of 5 KV grade in copper wires of size 4.00 Sqmm, 2 core ,laid in trenches/ laid under floor and including all acessories required for jointing and testing , complete all as specified and directed by Engineer-in- Charge. Notes : (i) Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items. (ii) The connection of this item shall be done as per site requirement. Any items/stores required alongwith any type of expert technicians/ electricians ets will be arranged by the contractor without any extra cost. Unit rate quoted will be deemed to include the cost of the same.
HDPE conduit pipe 40mm dia laid in trenches for protection of cable,complete all as specified and directed by Engineer-in-Charge. Note: Fittings & specials as required shall be provided by the contractor. Contractor's rate shall be deemed to include the cost of fittings provided.
Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete MS base plate and closed at top as specified, including necessary excavation and earth work , PCC 1:4:8 type D-2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block /coping etc including fair finishing the exposed surfraces even and smooth without using extra cement and necssary form work, disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint in and including dismantling of existing old damage steel pole/strut of any description ,complete all as specified and as directed by Engineer in charge. Notes : (i) Cost of Transportation of Pole at location shall deemed to be included in the rate quoted by contractor against this item and nothing extra shall be admissible on this account . (ii) Quoted rate of this item is deemed to inclusive cost of all the itmes mentioned therein and nothing extra shall be admissible on this account .
Weather proof/out door type PVC junction box of 30x30x15 cm size front door openable and having locking arrangment key type, including PVC cable glands for incoming and out going cables,comprising of MCB SP 6 Amps, 'B' Series 240 Volts TPN bus bar not less than 25x5mm aluminium strip and fixing clamps of size 25 x 5 mm two nos including necessary MS nut, bolts and locking arrangment with lock pressure type,connection hole in four Nos each bus bar with nuts ,bolts and washer made of galvanise iron and connection thimble etc, complete all as specified and as directed by Engineer-in-Charge.
Earthing complete with galvanised steel plate earth electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to GI strip 25x4mm at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 5 of SSR Part-I and testing ,complete all as specified and as directed by Engineer-in-Charge. Note : (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 1.00 metre away from earth.
Factory made LT feeder pillar box of size 750 mmx750 mm x 600 mm with 4 strip copper bus bar (200 Amp, 1100 volt grade, 600 mm long duly sleeved with relevant colored sleeve = 01 set) cubical double door outdoor type, weather proof , fabricated out 3.15 mm thick CRCA sheet, welded on 40 X 40 X 6 mm long below angle iron frame & having four Nos of angle iron legs made out of 40 X 40 X 6 mm- 120 cm long below frame groutal on ground with PCC 1:3:6 of suitable size with front,rear door having locking arrangements openable , bottom space for cable entry with & including dully powder coated with approved shade,complete all as specified and as directed by Engineer-in-Charge. Note: (i) Copper busbar in all panels should be colour coding RYB.
Isolation transformer 45 Watt per board of Model AGLST 45 W make of EFLA or equivalent made in EU for connection in Transformer box to Sign boards ,complete all as specified and as directed by Engineer-in-Charge.
Convertor DC to AC (12/24 Volt input DC and output AC 220 Volt) , complete all as specified and as directed by Engineer-in-Charge.
Secondary connector female and male end for runway lighting for two connections , complete all as specified and as directed by Engineer-in-Charge. Note for 149.00 to 151.00 :-The connection of this item shall be done as per site requirement. Any items/stores required alongwith any type of expert technicians/ electricians ets will be arranged by the contractor without any extra cost. Unit rate quoted will be deemed to include the cost of the same.
Illumilated signage boards of size 1730 x 800 mm and width of letter and numerial 64 mm, made up of PGI sheet 0.63 mm thick box type with 150 mm depth, front side 3 mm thick acrylic sheet of approved colour with suitable printing/tape marking and mounted on 40 mm heavy duty MS square tubing with 60 cm height above ground level and 45 cm below ground level and MS frame structure including necessary embeded in ground with PCC foundation 45 x 45 x 60 cm in 1:2:4 (20 mm graded aggregate including electrical connections with New Flexion LED strIp 24 W 6000 K range Flexible led strips with uniform light distribution and long lasting adhesive for perfect with Constant Voltage 12 V 2 A DRIVER , complete all as specified and as directed by Engineer-in-Charge.
All as per item No 152 here-in-before but of size 1664 x 800 mm and width of letter and numerial 64 mm , complete all as specified and as directed by Engineer-in- Charge.
All as per item No 152 here-in-before but of size 1638 x 800 mm and width of letter and numerial 64 mm , complete all as specified and as directed by Engineer-in- Charge.
All as per item No 153 here-in-before but of size 1420 x 800 mm and width of letter and numerial 64 mm , complete all as specified and as directed by Engineer-in- Charge.
All as per item No 153 here-in-before but of size 1354 x 800 mm and width of letter and numerial 64 mm , complete all as specified and as directed by Engineer-in- Charge.
All as per item No 152 here-in-before but of size 1320 x 800 mm and width of letter and numerial 64 mm , complete all as specified and as directed by Engineer-in- Charge.
All as per item No 152 here-in-before but of size 1908 x 800 mm and width of letter and numerial 64 mm , complete all as specified and as directed by Engineer-in- Charge.
All as per item No 152 here-in-before but of size 1732 x 800 mm and width of letter and numerial 64 mm , complete all as specified and as directed by Engineer-in- Charge.
All as per item No 152 here-in-before but of size 2600 x 1050 mm and width of letter and numerial 48 mm , complete all as specified and as directed by Engineer-in- Charge.
All as per item No 152 here-in-before but of size 2740 x 800 mm and width of letter and numerial 64 mm , complete all as specified and as directed by Engineer-in- Charge.
All as per item No 152 here-in-before but of size 1470 x 600 mm and width of letter and numerial 48 mm , complete all as specified and as directed by Engineer-in- Charge. .
Air termination single pointed aluminium rod, 12 mm dia, 300 mm long including mounting arrangment , complete all as specified and as directed by Engineer-in- Charge.
Aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground ,complete all as specified and directed by Engineer-in-Charge.
Note :Schedule of credit to be deducted on acceptances of bid.Details of Schedule of credit is given in tender documentse.
M/S MATLOOB AHMED
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .