Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-AOC | L1 | Accepted-AOC Contract is awarded to M/s Shete A J | |
| 2 | L2₹24.3 L+₹95,277 (4.08%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest quoted rate | |
| 3 | L3₹26.7 L+₹3.3 L (14.2%)Rejected-Finance | L3 | Rejected-Finance Rejected being other than lowest quoted rate | |
| 4 | L4₹27.5 L+₹4.2 L (17.9%)Rejected-Finance | L4 | Rejected-Finance Rejected being other than lowest quoted rate | |
| 5 | L5₹27.7 L+₹4.3 L (18.6%)Rejected-Finance | L5 | Rejected-Finance Rejected being other than lowest quoted rate |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
10 Nov 2023, 6:00 pmClosed
Shri Ankur Goyal, IDSE, EE
Military Engineer Services, Garrison Engineer (South) Ahmednagar - 414002
REPAIRS/ CLEANING OF SEWAGE LINE, MANHOLE, SEPTIC TANK, CULVERT, PATH, SURFACE CHANNELS, TOILETS, SANITARY FITTINGS, PLUMBING ETC TO MD/ OTM ACCN AT DAD AND CQA(V) UNDER GE(S) AHMEDNAGAR
2023_MES_623120_1
8115/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Ahmednagar
Class D Cat a (ii)
8 documents required · 8 mandatory
₹500
Garrison Engineer (South) Ahmednagar
₹80,000
Yes
15 Dec 2023
13 Oct 2023
13 Nov 2023
13 Oct 2023
10 Nov 2023
27 Oct 2023
13 Oct 2023 - 20 Oct 2023
Amount
Labour only for removing blockage of WC (Indian or EWC), urinal, bath and kitchen, gully trap including cleaning of pan, floor trap and removing blockage of down pipe upto1st manhole in foul conditions complete all as specified and as directed. Note : - (a) The item shall be operated on demand/complaint of users and shall be executed on specific written direction of JE/AGE . (b) All written docket shall be serially numbered, jointly signed including the user with bldg./Qtr No and entered in MB for the purpose of measurement and payment. (c) A recovery of Rs.200/-shall be levied as panalty from the contractor if the complaints are not done within 24 Hrs. Decision of GE in this regard shall be final and binding. Document in support of satisfatory completion of each complaint shall be preserved by contractor and submitted for verification.
Cleaning of existing SGSW/RCC pipe line upto 150 mm dia including intermediate manholes of any size in foul conditions by mechanical operated machine for removing blockage, taking out blocked sludge / debris etc collected in the manholes from pipe lines, cleaning & depositing sludge/debries to excavated pit/area, spreading necessary insecticise where sludge is deposited and covering the same with sand all as specified and as directed. Note :(a). All sludge/debried shall be deposited in nearest pit & covered with sand & necessary disinfection shall be carried out. (b). Rs 200.00 for each complaint shall be deducted from the payment of contractor in case complaint is not attended and rectified within 24 hours since ordered.
All as per serial item No. 2 here-in-before but 200 mm to 300 mm bore pipes.
Dewatering of sludge & removing the sludge from septic tank of capacity 25 to 50 users, in foul conditions cleaning the septic tank with water & removing the sludge outside the MD land & depositing, to carry out necessary disinfection where sludge is deposited all as specified and as directed
All as per serial item No. 4 here-in-before but septic tank of capacity 100 to 300 users
Cleaning of manhole upto any depth and taking out sludge, night soil, sludge water etc mechanically or manually and removing the same to a distance upto 5Km outside of MoD land and burried under ground including removing and refixing the manhole covers etc in foul conditions all as specifed and as directed. Note : (a) Rs. 200/-shall be deducted from the payment of contractor in case the complaint is not attended and rectified within 24 Hrs since ordered. (b) Internal size of manhole and depth of sludge only shall be measured and considered for payment.
Demolition of plain cement concrete in foundation, ground floors, pavings not exc 15 cm thickness (below or above ground level) all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specially provided for complete all as specified and as directed.
Demolition of PCC solid block masonry / brick masonry built in cement mortar including coping for manholes above or below GL in foul conditions or in any other condition all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing rubbish off the premises complete all as specified and as directed.
Dismantling stone slab and interlocking tiles of any description in floor, laid, bedded and pointed in any type of mortar all as specified and as directed
Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed
Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation, laying of pipe or for shafts, wells cesspits, man holes etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed.
Returning, filling, in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and as directed.
Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed.
M&L for hard core of gauge exc. 63 mm but n. exc. 100 mm, deposited spread and levelled in layers n. exc. 15cm thick, including watering and rammed etc. complete all as specified and as as directed.
M&L for PCC 1:4:8, type D2, using 40 mm graded stone aggregates as in foundation of manholes complete all as specified and as directed.
M&L for PCC 1:3:6, type C1 (using 20mm graded stone aggregates) as in coping including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and as directed.
M&L for RCC 1:2:4, type B1, using 20mm graded stone aggregates as in slabs of septic tank, supported on walls etc complete all as specified and as directed.
M&L for precast reinforced cement concrete, 1:2:4, type B-1, using 20 mm graded stone aggregates as in manhole cover slabs including necessary forms, moulds etc and finishing concrete surface, even and smooth without using extra cement complete all as specified and as directed.
M&L for precast PCC solid block masonry with PCC 1:5:8 blocks, exc 10 cm width, built in cement mortar 1:6 complete all as specified and as directed.
M&L for brickwork with sub class 'B' bricks, straight or curved on plan exc 6m mean redius, built in cement mortar 1:6 complete all as specified and as directed.
All as per serial item No. 22 here-in-before but except bricks Note : Serviceable bricks obtained from demoition shall be reused
Use and waste of form work to soffits and edges of suspended slab for septic tank and similar work, not exceeding 200mm thick for fair finished surfaces of confrete complete all as specified and as directed.
M&L for mild steel TMT bars, 10mm dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
All as per serial item No 25 above but 6 mm to 8 mm dia
M&L for mild steel work as in bands, straps, supports or stays, clamps, hold fasts, rungs, hooks, handles for manhole covers and similar articles conforming to Fe-410-0 all as specified and as directed.
M&L for mild steel angle iron frame work conforming to Fe-410-0 or Fe-310-00 for placing manhole cover complete all as specified and as directed.
M&L for water proofing treatment to floor & vertical surfaces of sunken portion complete comprising the following :- (a) After demolition of floor and lime concrete etc. remove all loose particles along with existing water proofing treatment (any No of layers) with wire brushes and cleaning the surfaces with water. (b) Brushing cement slurry with 1.2 kg of cement per square meter duly blended with & including water proofing compound Dr.Fixit or equivalent. (c) 15mm thick (Average thickness) plaster in cement mortar (1:4) mixed with WP compound on sunken surface including walls. The corner of sunken portion shall be rounded in concave shape and adequate slope shall be made during plastering to accommodate sump pipe and curing the sunken portion with water minimum for 48 hrs by ponding. (d) Applying a coat of bitumen primer @ 0.30 litre/sqm on prepared plastered surface, Applying self adhesive type APP based polymeric membrane minimum weighing not less than 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non-woven fabric (weight not less than 150 gm/sqm (e) M&L for PCC 1:4:8 for filling of sunken portion after conceling all membrane and sealing all joints to the entire with broken bats and light weight, floor area of WC/Bath not exceedding 2.00 sqm on plan and provide hole in the wall and fix 830 mm long 20 mm dia GI spouts light grade, PCC 1:3:6, type C1 (using 20 mm graded stone aggregates) filling complete all as specified and as directed. Note- The rates include for drilling of the hole RCC @ 1.00 m centre to centre, to a depth to a length of 30 mm and fixing of PVC pipes of dia 15/20 mm laid dry and grouting with cement slurry mixed with can bax 100 chemical with pressure grouting with minimum 3 Kg/Sqm complete all as specified and as directed
M&L for water proofing treatment to floor & vertical surfaces of sunken portion complete comprising the following :- (a) After demolition of floor and lime concrete etc. remove all loose particles along with existing water proofing treatment (any No. of layers) with wire brushes and cleaning the surfaces with water. (b) Brushing cement slurry with 1.2 kg of cement per square meter duly blended with & including water proofing compound Dr.Fixit or equivalent . (c) 15mm thick (Average thickness) plaster in cement mortar (1:4) mixed with WP compound on sunken surface including walls. The corner of sunken portion shall be rounded in concave shape and adequate slope shall be made during plastering to accommodate sump pipe and curing the sunken portion with water minimum for 48 Hrs by ponding. (d) Applying a coat of bitumen primer @ 0.30 litre/sqm on prepared plastered surface, Applying self adhesive type APP based polymeric membrane minimum weighing not less than 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non-woven fabric (weight not less than 150 gm/sqm (e) M&L for PCC 1:4:8 for filling of sunken portion after conceling all membrane and sealing all joints to the entire with broken bats and light weight, floor area of WC/Bath exceeding 2.00 sqm but not exceeding 3.00 sqm on plan and provide hole in the wall and fix 830 mm long 20 mm dia GI spouts light grade, PCC 1:3:6, type C1 (using 20 mm graded stone aggregates) filling complete all as specified and as directed. Note- The rates include for drilling of the hole RCC @ 1.00 m centre to centre, to a depth to a length of 30 mm and fixing of PVC pipes of dia 15/20 mm laid dry and grouting with cement slurry mixed with can bax 100 chemical with pressure grouting with minimum 3 Kg/Sqm complete all as specified and as directed
M&L for 75 mm thick PCC 1:4:8, type D-2, using 40 mm graded stone aggregates as in sub base complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in plinth protection, etc finished the surfaces even and smooth without using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed.
M&L for coloured non skid ceramic tiles, 7 to 8 mm thick (square/ rectangular), area of each tile not exceeding 0.11 sqm, as in floors etc. laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles complete all as specified and as directed.
M&L for coloured glazed ceramic tiles of size 300mm x 200mm x 7mm thick / 450mm x 300mm x 7 mm thick on vertical surfaces, over and including 10 mm thick cement plaster in cement mortar 1:4, set & jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles complete all as specified and as directed.
M&L for mirror polished machine cut Kota stone slab flooring, 20-25 mm thick over and including 20 mm thick screed bed in cement mortar (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and as directed Note:- The size of kota stone slab not less than 550mm x 550mm.
M&L for mirror polished machine cut kota stone slab, 18-22 mm thick over and including 10 mm thick cement plaster in cement mortar (1:4) on vertical surfaces such as risers of steps, skirting, dado and pillars, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and as directed.
M&L for providing and laying 60 mm thick factory made chamfered edge precast cement concrete paver blocks (interlocking tiles) of M-35 grade with any colour, design & pattern in foot path, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer, through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of brick or concrete surfaces in cement mortar 1:4 and finished the surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of new plastered or previously untreated surfaces of walls and applying two coats of cement base paint over a coat of primer all as specified and as directed
M&L for preparation of new concrete surfaces and applying two coats of synthetic enamel paint over a coat of primer all as specified and as directed
M&L for SGSW pipes of grade 'A', internal dia 150 mm, laid in trenches over PCC bed concrete and jointed & pointed in cement mortar 1:1 including demolition of bedding and haunching concrete and taking out old pipes in foul condition complete all as specified and as directed. Note : Excavation, earthwork and PCC bed and haunching concrete shall be measured and paid seperately under respective item.
M&L for RCC hume pipes, 150 mm bore dia, class NP2, laid in trenches over PCC bed concrete and jointed with collars including demolition of bedding and haunching concrete and taking out old pipes in foul condition complete all as specified and as directed. Note:- (i) Before starting the work the site shall be shown to the GE for his approval for laying the pipe. (ii) Paid vouchers duly verified by all the concerned shall be produced at the time of payment. (iii) Excavation, earthwork and PCC bed concrete shall be measured and paid for seperately under respective item.
All as per serial item No. 42 here-in-before but for 200 mm bore pipes
All as per serial item no. 42 here-in-before but for 300 mm bore pipes
M&L for PCC 1:4:8, type D-2, using 40 mm graded stone aggregates as in concrete bed for 150 mm bore dia drain pipes, any type, including packing under and haunching against the sides of the pipes after they are laid & tested complete all as specified and as directed.
All as per serial item No. 45 here-in-before but for 200 mm bore dia pipes.
All as per serial item No. 45 here-in-before but for 300 mm bore dia pipes.
S&F in repairs, pillar tap, 15mm bore, chromium plated, cast copper alloy with capstan heads, screwed down high pressure, with long screwed shank screwed for iron pipe,15mm bore dia all as specified and as directed.
S&F in repairs bib tap, 15 mm dia, cast copper alloy, chromium plated with crutch or butterfly handle screwed down for iron pipe or for brass ferrule all as specified and as directed.
S&F in repairs, stop valves/ angular stop valve, 15mm dia, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and as directed.
S&F in repairs 2 in 1 bib tap, 15 mm dia, cast copper alloy, chromium plated with crutch or butterfly handle screwed down for iron pipe or for brass ferrule all as specified and as directed.
S&F in repairs, health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed.
S&F in repairs, PVC connection, 15mm dia and 600mm long with adopter nuts of PVC complete all as specified and as directed.
S&F in repairs, 75 mm dia, PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and as directed.
S&F in repairs, 110 mm dia, PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and as directed.
S&F in repairs, 75 mm dia, PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.
S&F in repairs, 110 mm dia, PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.
S&F in repairs, 75 mm dia, PVC (SWR) bends, any radius with access door complete all as specified and as directed.
S&F in repairs, 110 mm dia, PVC (SWR) bends, any radius with access door complete all as specified and as directed.
S&F in repairs, 75 mm dia PVC (SWR) branch piece, single (single Y) equal or unequal, complete all as specified and as directed.
S&F in repairs, 110 mm dia PVC (SWR) branch piece, single (single Y) equal or unequal, complete all as specified and as directed.
S&F in repairs, 75 mm dia PVC (SWR) branch piece, double (double Y) equal or unequal complete all as specified and as directed.
S&F in repairs, 110 mm dia PVC (SWR) branch piece, double (double Y) equal or unequal complete all as specified and as directed.
S&F in repairs, 75 mm dia PVC (SWR) junction, single, (single T) equal or unequal complete all as specified and as directed.
S&F in repairs, 110 mm dia PVC (SWR) junction, single, (single T) equal or unequal complete all as specified and as directed.
S&F in repairs, 110 mm dia PVC (SWR) reducer complete all as specified and as directed.
S&F in repairs, 75 mm dia PVC (SWR) vent cowl complete all as specified and directed.
S&F in repairs, 110 mm dia PVC (SWR) vent cowl complete all as specified and directed.
S&F in repairs, PVC (SWR), 75 mm outer dia floor trap, plain with grating including jointing with solvent cement, complete all as specified and as directed.
M&L in repairs, vitreous China squatting pan 'Orissa' pattern, size 630 x 450 mm, white, with integral foot rests (excluding flusing cistern & flush pipe) including traps & provision of cement concrete bedding (1:3:6), type C-2, using 40mm graded stone aggregates complete all as specified and as directed..
M&L in repairs, vitreous China wash down water closet pan (pedestal pattern/anglo pattern) white including plastic water closet seat cover, closed pattern with flat bottom and cover and mild steel chromium plated hinging device (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and as directed.
S & F in repairs, vitreous china wash hand basin, angle back, size 600 mm x 480 mm, white, with and including brackets, pillar tap, 15 mm bore chromium plated, cast copper alloy with capstan heads, screwed down high pressure, with long screwed shanks, 32 mm waste coupling brass chromium plated suitable for wash hand basins with long screwed shanks and fly nuts and PVC waste pipe,15mm dia PVC connection pipe 600mm long fixed complete all as specified and as directed.
S&F in repairs, vitreous china, bowl urinal, flat back, 440mm x 345mm x 250 mm, white with grating and union for discharge pipe, including cromium plated urinal spreader, fixing properly with plugs all as specified and as directed.
S&F in repairs, 10 litres capacity, PVC valveless , syphonic action type, flushing cistern, low level , white with inlet ball valve and handle including brackets complete all as specified and as directed.
M&L in repairs, plastic water closet seat cover, white, closed pattern with flat bottom and cover and mild steel chromium plated hinging device (excluding fixing bolts) complete all as specified and as directed.
S&F in repairs, 32mm dia semi rigid PVC waste pipe for sink, urinal, wash hand besin etc, length not less than 900mm complete all as specified and as directed.
S&F in repair salt glazed stone ware gully trap, square mouthed type P of size 150mm x 150mm complete all as specified and as directed.
M.H Construction
Ms. D.G. SHIRKE
Arihant Construction
AZAD SERVICES
M/s.D.K.ALKUTE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .