Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.1 LQualified Make: MICROTEK 1KVA OFFLINE UPS
Model: MICROTECK 1KVA UPS 01 DULARI NAGAR RUDRI ROAD DHAMTARI DHAMTARI CHHATTISGARH 493776 UDYAM CG 04 0012212 | DHAMTARI | CHHATTISGARH | 493776 | Make: MICROTEK 1KVA OFFLINE UPS
Model: MICROTECK 1KVA UPS | ₹1.1 L | L1 | Qualified |
| 2 | L3₹1.1 LQualified Make: MICROTEK 1KVA OFFLINE UPS
Model: UPS 1 KVA Double Battery&Rating in KVA/ min VAH capacity of battery (KVA/VAH) -1.0/1200 with set packformat 0 RAM KUNJ NEAR SHIV HANUMAN MANDIR FIRENDS COLONY KAMRE PANDRA RANCHI JHARKHAND 835222 UDYAM JH 20 0042072 | RANCHI | JHARKHAND | 835222 | Make: MICROTEK 1KVA OFFLINE UPS
Model: UPS 1 KVA Double Battery&Rating in KVA/ min VAH capacity of battery (KVA/VAH) -1.0/1200 with set packformat | ₹1.1 L | L3 | Qualified |
| 3 | Qualified Make: MICROTEK 1KVA OFFLINE UPS
Model: UPS 1 KVA Micro-Tech 1009 IN FRONT OF UMC CIVIL LINES UNNAO UNNAO UTTAR PRADESH 209801 | UNNAO | UTTAR PRADESH | 209801 | Make: MICROTEK 1KVA OFFLINE UPS
Model: UPS 1 KVA Micro-Tech | - | - | Qualified |
| 4 | L2₹1.1 LDisqualified Make: microtek
Model: Microtek & 1 KVA UPS Microtek 4 20 HARI OM TRADERS SUKHARIA SHOPPING CENTRE 335001 SRI GANGANAGAR RAJASTHAN 335001 | GANGANAGAR | RAJASTHAN | 335001 | Make: microtek
Model: Microtek & 1 KVA UPS Microtek | ₹1.1 L | L2 | Disqualified |
| 5 | Disqualified Make: BPE
Model: BPE UPSX1101L2 | Make: BPE
Model: BPE UPSX1101L2 | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
9 Oct 2018, 5:00 pmClosed
Line Intractive UPS With AVR ( 19 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/800 * Technology MOSFET-PWM MOSFET-PWM
IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 Rated Output (Volt) Single phase sinewave 230v AC
50Hz Single phase sinewave 230v AC
50Hz
Single Phase Quasi-Sin-wave 230 V AC
50 Hz Degree of protection IP-21 IP-21
IP 20 Inverter Efficiency (%) >/= 70% >/= 60%
>/= 70% Warranty for the battery from the date of delivery 1 year 1 year
3 Years Warranty for Line Interactive UPS 1 Year 1 Year
2 Years
5 Years
3 Years Installation and No * 1/4 commissioning instructions CONSTRUCTIONAL Type of enclosure Mild steel * AC out put for printer (not through inverter) No Yes
No Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 2 Three pin
3 Three pin
Hard wiring
Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% * Input (Volt) Single phase sinewave(160-280v) * Switching over time (Mili sec) Maximum 10 milli seconds * Overload Time (Minutes) >/= 10 minutes * Load power factor >/= 0.6 * Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%
50 +/-3 Hz * Overload (%) >/=10% * Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% * Variation on output frequency in battery mode (Hz) </=0.5 * PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 * Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts
the system shall switch over to battery mode Yes * Protection against short circuit of UPS Yes * Protection for over voltage and over load Yes * 2/4 REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree
RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes * Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes * Cold Test as per IS:9000 pt-2/sec-4 Yes * Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes * Type Test certificate no. and date - * Name Of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Michael D Souza 145001
HQ 21 Sub Area
Opp GREF Station
Bharoli Kalan
NH 44
Pathankot
Pin - 145001 19 15
663482
GEM/2018/B/94109
Line Intractive UPS with AVR
15 days
Punjab; Pathankot
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Line Intractive UPS With AVR ( 19 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/800 * Technology MOSFET-PWM MOSFET-PWM | - | - | - |
| IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 Rated Output (Volt) Single phase sinewave 230v AC | - | - | - |
| 50Hz Single phase sinewave 230v AC | - | - | - |
| 50Hz | - | - | - |
| Single Phase Quasi-Sin-wave 230 V AC | - | - | - |
| 50 Hz Degree of protection IP-21 IP-21 | - | - | - |
| IP 20 Inverter Efficiency (%) >/= 70% >/= 60% | - | - | - |
| >/= 70% Warranty for the battery from the date of delivery 1 year 1 year | - | - | - |
| 3 Years Warranty for Line Interactive UPS 1 Year 1 Year | - | - | - |
| 2 Years | - | - | - |
| 5 Years | - | - | - |
| 3 Years Installation and No * 1/4 commissioning instructions CONSTRUCTIONAL Type of enclosure Mild steel * AC out put for printer (not through inverter) No Yes | - | - | - |
| No Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 2 Three pin | - | - | - |
| 3 Three pin | - | - | - |
| Hard wiring | - | - | - |
| Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% * Input (Volt) Single phase sinewave(160-280v) * Switching over time (Mili sec) Maximum 10 milli seconds * Overload Time (Minutes) >/= 10 minutes * Load power factor >/= 0.6 * Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9% | - | - | - |
| 50 +/-3 Hz * Overload (%) >/=10% * Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% * Variation on output frequency in battery mode (Hz) </=0.5 * PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 * Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts | - | - | - |
| the system shall switch over to battery mode Yes * Protection against short circuit of UPS Yes * Protection for over voltage and over load Yes * 2/4 REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree | - | - | - |
| RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes * Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes * Cold Test as per IS:9000 pt-2/sec-4 Yes * Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes * Type Test certificate no. and date - * Name Of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Michael D Souza 145001 | - | - | - |
| HQ 21 Sub Area | - | - | - |
| Opp GREF Station | - | - | - |
| Bharoli Kalan | - | - | - |
| NH 44 | - | - | - |
| Pathankot | - | - | - |
| Pin - 145001 19 15 | - | - | - |
Exempted
9 Oct 2018
11 Oct 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_663482.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].