Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC | ₹7.5 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹7.5 LRejected-Finance | ₹7.5 L | L2 | Rejected-Finance Rate quoted above Lowest bidder |
| 3 | L3₹7.5 LRejected-Finance AT DHANDA P O NUTANGRAM P S ONDA DIST BANKURA PIN 722152 | BANKURA | BANKURA | WEST BENGAL | 722152 | ₹7.5 L | L3 | Rejected-Finance Rate quoted above Lowest bidder |
| 4 | L4₹7.6 LRejected-Finance AT BENJTABANI P O BAIDYANATHPUR DIST BANKURA PIN 722140 | BANKURA | WEST BENGAL | 722140 | ₹7.6 L | L4 | Rejected-Finance Rate quoted above Lowest bidder |
Tender Value
₹7.5 L
EMD Value
₹15,062
Closing Date
18 Feb 2026, 11:00 amClosed
Executive Engineer (AM)
OFFICE OF THE EXECUTIVE ENGINEER (AGRI - MECHANICAL) BANKURA (AGRI - MECHANICAL) DIVISION, ADMINISTRATIVE BUILDING PRANABANANDA SARANI, P.O. KENDUADIHI, DIST. BANKURA
Repairing of Spout chamber, Extension of PipeLine,Replacement of Distribution chamber, Repairing of Pump House and Interal wiring For Gobindpur Govt. Owned and Operated Major RLI Scheme Indpur Block Under Bankura-II (A-M) Sub-Division Ban DV Non
2026_WRDD_996201_1
WBWRIDDEEAM/BANeNIT49/NP/25-26
Open Tender
Project Work
45 days
EE AM BANKURA AM DIV
Please refer Tender documents.
4 documents required · 4 mandatory
₹15,062
2 Mar 2026
3 Feb 2026
20 Feb 2026
3 Feb 2026
18 Feb 2026
3 Feb 2026
MATERIAL Rigid P.V.C. pipes with one loose coupler for every 6.0 mtr. Length and solvent cement accordingly to technical specification as per I.S.No. 4985/2000 with latest amendments and duly I.S.I. certification marked & CIPET tested. 200 mm.dia Class-I (0.25 MPA) with Coupler
140 mm.dia Class-I (0.25 MPA) with Coupler
160 mm.dia Class-II (0.40 MPA)
Rigid P.V.C. Accessories of Class-II (0.4 MPA) according to Technical specification as per relevant IS Code with latest amendment & duly I.S.I. certification marked & CIPET tested. 160 mm.dia F.T.P. with Metallic flange
200 mm.dia 90̊ Bend
140 mm.dia 900 Bend
200 x 140 mm.dia Reducer
160 x 140 mm.dia Reducer
200 mm.dia Equal Tee
140 mm.dia Equal Tee
200 mm.dia End Cap, class-III
140 mm.dia End Cap
200 mm.dia Extra Coupler
160 mm dia Extra Coupler
140 mm.dia Extra Coupler
Solvent cement conforming to I.S. No. 14128/94 with latest amendments, Medium Bodies.
Rubber Insertion, duly, reinforced 5 mm.thick 2 plies as per I.S.No.-6392 with latest amendments. 150 mm.dia (Table-17)
150 mm.dia (Table-5)
MS ACESSORIES:- 150 mm.dia Alfa Alfa Valve (Nipple Type as per IS 210)
MS ACESSORIES:-150 mm.dia C.I Sluice Valve (ISI Marked IS-14846)
Nut & Bolt :G.I 20 mm x 80 mm
20 mm x 100 mm
16 mm x 80 mm
16 mm x 65 mm
16 mm x 50 mm
Foundation Bolt :- G.I For Distrubution Chamber (20 mm.dia x 375 mm.long)
For Motor driven Pump Sets
Compresed Asbestos fibre jointing for Quadruped Set (for raised surface of Flange as per IS-6392/71) 500 mm.dia (Table-5)
Pump House Dismantling of all types of plain Cement Concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor (a) upto 150 mm. thick
Dismantling all types of masonry exception cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 mtrs
Stripping of wornout plaster and raking out jointsof walls, ceiling etc. upto any height and in any floor including removing rubbish and stacking as directed.
Ordinary Cement concrete (Mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur variety
Hire and labour charges for shuttering with centering and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 25 mm. to 30 mm. thick wooden shuttering. For PUMP HOUSE
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. For works in foundation, basement and upto roof of ground floor / upto 4m. Tor steel/Mild steel ( Other than SAIL/ TATA/RINL) i)For foundation Blocks of Water Distribution System
Brick work in cement mortar (1 : 6) with first class kiln burnt bricks including racking out joints, scaffolding and other incidental works etc. complete. b) In superstructure ground floor
Plaster (to wall, floor, ceiling etc.) with (1:6) sand and cement mortar including rounding off or chamfering corners, as directedand racking out joints or roughening of concrete surface including throating. Nosing and drip course as necessary at ground floor. (a) 15 mm thick (1:6) proportion.
b) 20 mm thick with 1:6 cement mortar.
c) 10 mm thick with 1:4 cement mortar.
Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. complete.
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg/sq. Mtr. and up to 16 Kg/sq. mtr.
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials.
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete A) UPVC Pipes:(i) 75 mm. Dia
B) UPVC Fittings:a) Plain Tee (i) 75 mm. Dia
C) Bend 87.5 degree (i) 75 mm. Dia
Priming one coat on timber, plastered surface with synthetic enamel/oil boud primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. Two coats (super gloss hi- gloss except white) (b) On steel surface (Normal gloss).Two coats (with any shade except white).
White washing including cleaning and smoothening surface thoroughly (5 parts of stone lime and 1 part of shell lime should be used in finishing coat) all floor b) Three coats
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification. ii) b) Two coats
Carriage 4% on (SL No.-29 to 48)
WATER TRANSMISSION ARRANGEMENT Repair of puncture/holes of any size in existing P.V.C. pipeline of HDTW/MDTW/RLI by placing half round P.V.C. pipe section of required size to cover the Holes/puncture having adequate bearing on all sides and joining the half round section with solvent cement after roughening the surface with wirw brush ,emery paper to make the joint leak proof as per direction of engineer -in-charge (cost inclusive of supplying sovent cement at site and transportation of required length of P.V.C. pipe to be issued departmentally ,for cutting half round section, from Sub-Divisional stores to site)i) 200 mm dia. PVC Pipe
iii)140 mm dia PVC pipe
Dismantling all types of masonry exception cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 mtrs.)
Dismantling of all types of plain Cement Concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor (a) upto 150 mm. thick
Stripping of wornout plaster and raking out jointsof walls, ceiling etc. upto any height and in any floor including removing rubbish and stacking as directed.
Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm
Earthwork in excavation of field trenches as per designed section & alignment for laying of pipe lines(PVC,RCC,ACP etc.) upto a depth of 1500 mm in all sorts of soil including removing, spreading or stacking extra earth as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom as required complete.
Laying of P.v.C. pipes of different diameters within field trenches in curve /straight line using P.V.C. fittings, viz. Bend, Tee, Reducer etc. and making leak proof joints with couplers after roughening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittings and solvent cement to be supplied by Deptt.) all complete as per direction of Engineer-in-Charge c) 200 mm dia
Earth work in filling in trenches after laying pipe lines (PVC,RCC,ACP etc.) with good earth obtained from excavation of field trences in layer not exceeding 225 mm , including watering & ramming etc. layer by layer complete. (payment will be made on the basis of measurement of finished quantity of work)
Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidating the same by through saturation with water ramming complete including the cost of supply of sand. (Payment to be made on measurment of finished quantity)
Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (Mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur vareit
Ordinary Cement concrete (Mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur vareity
Hire and labour charges for shuttering with centering and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of Engineer-In-Charge
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. For works in foundation, basement and upto roof of ground floor / upto 4m. Tor steel/Mild steelI. SAIL/ TATA/RINL (i)For foundation Blocks of Water Distribution System
Brick work with Ist class brick in cement mortar (1 : 6) . (a) In foundation and plinth
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (c) 15 mm thick plaster. .
Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. Complete..
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge. (i) 150 mm. dia. ERW pipe
Priming one coat on timber, plastered surface with synthetic enamel/oil boud primer of approved quality including smoothening surfaces by sand papering etc
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. Two coats (super gloss hi- gloss except white) (b) On steel surface (Normal gloss).Two coats (with any shade except white
Labour charges for fitting & fixing of 150 mm dia Sluice Valve.
Erection, fitting, fixing of set of M S Quadruped inlet and outlet pipe fittings for 1st chamber for Major RLI Scheme. (Rate inclusive of transportation from departmental store to work site
Labour charges for fitting, fixing 150 mm. Dia. Alfa-Alfa valve with 140 mm. dia.P.V.C. pipe with the help of flanged P.V.C. tail-piece by joining the P.V.C.End of Tail-piece and riser pipe with coupler and flanged end of Tail-piece and Alfa-Alfa valve with rubber insertion, nuts and bolts etc. complete.
Labour charges for fitting, fixing (150 mmx200 mm) dia MS expander with 200 mm dia UPVC pipe with the help of PVC flanged tail piece by joining flanged end of tail piece and expander with rubber insertion nuts and bolts and P.V.C end of tail piece with 200 mm dia. UPVC pipe with coupler all complete.
Installation of Diesel Engine /Electro-Motor pumping set of any make / brand and for RLI scheme on pump foundation over SAL sleeper (to be supplied departmentally) by fixing nuts and bolts and making connection of suction hose and foot valve with necessary fittings at the inlet end of the water pump and fitting fixing of 90° M S priming bend, sluice valve and delivery hose with all necessary fittings at the delivery end of the water pump, duly connected with the pipe line, maintaining proper alignment and level including cutting holes on the wall of the pump house where necessary, mending good damages after completion of the works as per direction of Engineer-in-charge. (Pump set and all accessories will be supplied departmentally
Testing of pipe line system against leakages by filling the distribution chamber with water and supplying water through the entirepipe line net work for at least 4 (four) hour by running the departmental Diesel Engine pumping set, including supplying necessary fuels & lubricants and hiring and transporting tools and plants all complete as per direction of Engineer-inCharge.
Carriage charge (4%) on every item from Sl. no-50 to 77 excluding Sl. No-55,56 & 58,77
INTERNAL WIRING Fitting of wooden pannel board of size 6ft. X 4ft. X 1 inch. with M.S. clamp on the wall of pump house and made necessary arrangment for fitting fixing the following elctrical equipment including 2 coat of pantigof app.quality as per direction of E.I.C.
Fixing only Sheet Steel Main Switch(Rewirwable type)/ Change over on Flat Iron Frame/Angle Iron Frame on wall 63 Amps On angle iron frame
Fixing only Sheet Steel Main Switch(Rewirwable type)/ Change over on Flat Iron Frame/Angle Iron Frame on wall 200 Amps On angle iron frame
Fitting & fixing of Starter (Direct on Line or Star-Delta/Auto- Transformer) with Nuts & Bolts fixed on Angle iron frame on wall and making necessary connection with the electrical cables. iii) Star-Delta / Auto-Transformer Starter (Above 15 HP upto 25 HP)
Fixing only MS sheet metal busbar Chamber on angle iron frame on wall. 4 bars, 200 Amps.
Meter loop connection with 1.1 K.v. Gr. 3% core 14 core 10 Sqmm to 50 Sq mm. p.v.C.! XLPE insulated & sheathed and armoured Aluminium/Copper Cable from Meter to incomming TPN Main Switch 1 Terminal. (Brand: Gloster/Havells/Finolex) d) For MAJOR RLI Scheme i) 50 Sqmm 3.5 Core Aluminium Cable
Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall/Kiosk Box , including making necessary connection to the pre-fixed devices with all necessary accessories like saddle, screw, clips, gland, socket etc. conforming to IEE regulation and as per direction of EIC. (Brand: Gloster/Havells/Finolex) (i) 4Cx 25 sqmm Copper cable conforming to IS 694 in [ 100/200 A TPN switch to Bus-bar]
(ii) 3C X 16 sqmm copper cable conforming to IS 694 [Busbar to 63 A, TP Main switch and 63 A TP switch to Motor starter]
(iii) 2 X 3C X 10 sqmm copper cable conforming to IS 694 in 32 mm GI conduit (ISI-Medium quality) [ Star-Delta Motor starter to Motor]
Supplying & fixing bulk head light fitting(Havells Make) on wall / Ceilling incl. S&F suitable 100 watts lamp complete with glass wire-guard and holder.
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI / PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casing capping and Switch board both on surface] (a) Average run 5 mtr
Connecting the equipments to earth busbar including S & F G (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages (a) Solid GI wire (iii) No. 8 SWG
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe
Supply & Fixing EI danger board on wall 20cm x 30cm ( 8" x 12" )
Insulation testing of internal wiring of Pump House/Kiosk Box including wiring of electric Motor & other ancilary equipments by means of Megger
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Add GST @18% for the item No (29 to 94) on 365813.77
cess 1% on for the item No (29 to 95) on 431660.24
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.24 MB
Tendernotice_2.pdf
PDF • 0.83 MB
Tendernotice_3.pdf
PDF • 0.10 MB
BOQ_2438937.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid