Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹9.0 L+₹1.4 L (18.4%)Admitted-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | MUKTI ENTERPRISES L1 | Rama Electricals L2 |
|---|---|---|---|---|---|
| 1.00Point wiring with multi-stranded copper conductor, single core, FRLSH PVC insulated and unsheathed cable, including FRLSH PVC insulated unsheathed stranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes, ISI MARKED, with 3 mm thick plastic/bakelight laminated sheet cover having necessary cutting for fixing switches/ sockets comprising the following: - | |||||
| 1.01 | One light/fan/exaust fan point controlled by one switch (one way) of 6 Amp or one fan point controlled by one switch(one way) of 6 Amp & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit, complete all as specified and directed. | 6 | Per Point | 650 ₹3,900 Lowest | 900 ₹5,400 |
| 1.02 | One Socket outlet of 3-pin/ 5-pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, complete all as specified and directed. | 1 | Per Point | 355 ₹355 Lowest | 600 ₹600 |
| 1.03 | One Socket outlet of 3-pin/ 5-pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit,complete all as specified and directed. | 2 | Per Point | 655 ₹1,310 Lowest | 800 ₹1,600 |
| 1.04 | Point wiring with multi-stranded copper conductor, single core, FRLSH PVC insulated and unsheathed cable, including FRLSH PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes, ISI MARKED, with 3 mm thick plastic/Bakelight laminated sheet cover for One socket outlet three pin, 15/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable single core & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit, complete all as specified and directed. | 2 | Per Point | 677 ₹1,354 Lowest | 800 ₹1,600 |
| 1.05NOTES: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. (b) GI boxes shall be fixed flush to walls in position with cement mortar (1:4) complete all as directed. | |||||
| 2.00Point wiring with multi-stranded copper conductor, single core, FRLSH PVC insulated and unsheathed cable, including FRLSH PVC insulated unsheathed stranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes, ISI MARKED, with 3 mm thick plastic/bakelight laminated sheet cover having necessary cutting for fixing switches/ sockets comprising the following: - | |||||
| 2.01 | One light/fan/exaust fan point controlled by one switch (one way) of 6 Amp or one fan point controlled by one switch(one way) of 6 Amp & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC casing & caping, complete all as specified and directed. | 80 | Per Point | 655 ₹52,400 | 500 ₹40,000 Lowest |
| 2.02 | One Socket outlet of 3-pin/ 5-pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, complete all as specified and directed. | 10 | Per Point | 300 ₹3,000 Lowest | 500 ₹5,000 |
| 2.03 | One Socket outlet of 3-pin/ 5-pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty casing & caping ,complete all as specified and directed. | 10 | Per Point | 655 ₹6,550 Lowest | 800 ₹8,000 |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
12 Aug 2026, 6:00 pmClosed
GARRISON ENGINEER AIR FORCE BIHTA
Military Engineer Services AF Stn bihta 801103
REPAIR/ REPLACEMENTS TO INTERNAL WIRING, LIGHT FITTINGS, FANS AND SUMMER, COOLING APPLIANCES CONNECTED WORKS AT AF STN DARBHANGA UNDER GE AF BIHTA
2026_MES_772425_2
GE/AF/BHT-12/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DARBHANGA UNDER GE AF BIHTA
Refer NIT and Tender Documents
8 documents required · 8 mandatory
₹500
GE AF BIHTA
₹16,000
Yes
20 Aug 2026
25 Jul 2026
15 Aug 2026
25 Jul 2026
12 Aug 2026
25 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Point wiring with multi-stranded copper conductor, single core, FRLSH PVC insulated and unsheathed cable, including FRLSH PVC insulated unsheathed stranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes, ISI MARKED, with 3 mm thick plastic/bakelight laminated sheet cover having necessary cutting for fixing switches/ sockets comprising the following: - | |||||
| 1.01 | One light/fan/exaust fan point controlled by one switch (one way) of 6 Amp or one fan point controlled by one switch(one way) of 6 Amp & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit, complete all as specified and directed. | 6 | Per Point | - | - |
| 1.02 | One Socket outlet of 3-pin/ 5-pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, complete all as specified and directed. | 1 | Per Point | - | - |
| 1.03 | One Socket outlet of 3-pin/ 5-pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit,complete all as specified and directed. | 2 | Per Point | - | - |
| 1.04 | Point wiring with multi-stranded copper conductor, single core, FRLSH PVC insulated and unsheathed cable, including FRLSH PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes, ISI MARKED, with 3 mm thick plastic/Bakelight laminated sheet cover for One socket outlet three pin, 15/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable single core & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit, complete all as specified and directed. | 2 | Per Point | - | - |
| 2Point wiring with multi-stranded copper conductor, single core, FRLSH PVC insulated and unsheathed cable, including FRLSH PVC insulated unsheathed stranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes, ISI MARKED, with 3 mm thick plastic/bakelight laminated sheet cover having necessary cutting for fixing switches/ sockets comprising the following: - | |||||
| 2.01 | One light/fan/exaust fan point controlled by one switch (one way) of 6 Amp or one fan point controlled by one switch(one way) of 6 Amp & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC casing & caping, complete all as specified and directed. | 80 | Per Point | - | - |
| 2.02 | One Socket outlet of 3-pin/ 5-pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, complete all as specified and directed. | 10 | Per Point | - | - |
| 2.03 | One Socket outlet of 3-pin/ 5-pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty casing & caping ,complete all as specified and directed. | 10 | Per Point | - | - |
| 2.04 | Point wiring with multi-stranded copper conductor, single core, FRLSH PVC insulated and unsheathed cable, including FRLSH PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes, ISI MARKED, with 3 mm thick plastic/Bakelight laminated sheet cover for One socket outlet three pin, 15/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable single core & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty casing & caping, complete all as specified and directed. | 10 | Per Point | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
Tender122627.pdf
Tender Documents • 0.90 MB
BOQ_874683.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .