| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 CrAccepted-AOC C 2488 SUSHANT LOK PHASE 1 GURGAON 122001 HARYANA | GURUGRAM | HARYANA | 122001 | ₹22.3 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹24.6 CrRejected-Finance F 18 ANSAL COMPLEX OPP JWALA HARI MARKET PASCHIM VIHAR NEW DELHI 110063 | NEW DELHI | WEST DELHI | DELHI | 110063 | ₹24.6 Cr | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹24.8 CrRejected-Finance PLOT NO 137 2ND FLOOR AVTAR ENCLAVE PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | ₹24.8 Cr | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹25.1 CrRejected-Finance | ₹25.1 Cr | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹27.1 CrRejected-Finance | ₹27.1 Cr | L5 | Rejected-Finance Not being lowest |
Tender Value
Refer Docs
EMD Value
₹14.8 L
Closing Date
25 Dec 2020, 6:00 pmClosed
CHIEF ENGINEER DELHI ZONE
HQ CE DELHI ZONE Delhi Cantt-10
PROVN OF DEFICIENT SAILORS MD ACCN (72 DUs) AT NARAINA BAGH NEW DELHI UNDER GE (P) WEST DELHI CANTT-10
2020_MES_391765_1
CEDZ-25 of 2020-21
Open Tender
Civil Works
810 days
DELHI CANTT
MES contractor enlisted in MES under class SS cat a i having deposited Standing Security of Rs 15.00 lakh with department. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
9 documents required · 9 mandatory
₹3,000
Yes
GE(P) WEST
₹14.8 L
Yes
25 Feb 2021
4 Nov 2020
28 Dec 2020
4 Nov 2020
25 Dec 2020
11 Dec 2020
Amount
INTERNAL WATER SUPPLY)
S&F Brass CP mixer for mixing Hot & Cold water screwed down for iron pipe & fixed complete all as specified and directed. Make :- Jaquar Cat Part No CON CHR 273 KNUPR/ CERA F1015401)
INTERNAL ELECTRIC SUPPLY)
S&F VTPN DB's 415 Volts, IP-43, with MCCB 63 AMP, 4 pole as incommer, 4 way with 200 Amps rated copper bus bar double door type complete all as directed
S&F Metal and glass decorative wall lights 1X 20 Watt complete all as directed. Make : Philips cat no. 30762 Delite or equivalent in Bajaj/ Surya/ CG
S&F Decorative box type fitting with end caps pre wired for LED tube light fittings 16 watts with side holder, accessories and including connecting up with twin twisted flexible copper conductor cable of size 23/0.0076 from ceiling rose to light fittings complete including LED lamp all as specified and as directed.
All as per Srl item No 6 here-in-before but 8 watt
M&L Lamp holder, insulated body, with back plate suitable for batten/angle fitting including 9 watt LED Complete all as directed by Engineer-in-charge.
Supply & fix Round surface mounted LED flat panel fitting 1X18 watt, PDC aluminium housing and PMMA diffuser makes it a robust luminaire complete all as directed. Make : CG cat no.LCDSPLN-R-18-CDL or equivalent in Bajaj/ Surya/ Philips
All as per Srl item No 9 here-in-before but 6 watt
M & L Exhaust Fan 200 mm Sweep, 240 Volt, AC 50 HZ , PVC body , heavy duty including lovers with and including cutting bricks/stone boulders wall for fixing of fan and finished the cutting surface even and smooth by using cement morter complete all as specified and directed.(Make: Havels cat no Ventil Air-DX WHT/BLK or equivelent in CG,Bajaj)
M & L Exhaust Fan 300 mm Sweep, 240 Volt, AC 50 HZ , Metal body, heavy duty including lovers with and including cutting bricks/stone boulders wall for fixing of fan and finished the cutting surface even and smooth by using cement morter complete all as specified and directed.
S&F Ceilling fan 1200 mm sweep, 230 volt, 50 HZ, BEE 5 star rating, BLDC with remote control complete all as specified and directed.
Supply, install, commissioning and testing busbar trunking 4 pole air isulated busbar, 3 phase 4 system (3P+N) of copper busbar 300 Amp 36 KA including with all accessories like Elbow, Flange End & hanger anchor bolt with MS angle support, busbar trunking enclosed shall be made of 1.5 mm thick aluminium, integral earth in GI in 1.5 mm 12KV impluse withstand & IP 54 with piug in point and IP-55 without plug in point with IP-55 busbar trunckimg enclosure shall provide a protection not less than IP-55 for feeder element & for distribution elements IP-55 as per IEC-529 with multilayer PET Class -F insulation, temprature rise of 55 deg centigrate over an ambient of 40 deg C as per IEC/EN60439-1&2
S & F Tap off box including MCB TPN complete all connection 63 Amp capacity with MCB TPN 63 Amp, 10 KA all as directed by Engineer-in-charge.
S&F AC single phase static energy meter of accuracy class 1.0, 240 V, 50 Hz with Backlit LCD display of rating 5 - 30 A, (measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power with transparent hinge type box complete all asspecified and directed.
S&F HOT press moulded SMC Meter box of inside dimensions 250x150x155 mm with hinged doors and all accessories required for fixing 01 nos single phase digital electronic meter complete all as specified and directed.
S&F envirounment friendly energy saving surface mounted bulk head LED lumaniare with 10 W LED IP 65 complete all as specified and directed.
S&F end feed unit with provn of and including MCCB 4 pole upto 400A, suitable for copper bus bar trunking of 400A 3 phase with earthing strip complete all as specified and directed.
S&F MCB single pole & neutral 16 Amp 240 volts 10 KA repturing capacity 'B' Curve complete all as specified and directed.
(EXTERNAL WATER SUPPLY)
S &F Centrifugal monoblock pump set suitable for 415 V, 3 phase system with not less than 50Cum/hr at 60 mtr head complete including suitable size of foot valve, suction pipe, delivery pipe, NRV, Sluice valve & pressure gauge, complete along with Electrical/Control panels, power and control cabling ,cable trays, and all accessories as specified and directed by Engineer-in-charge.
Supply installation testing and commissioning factory made and tested (incl CPRI type test certified) LT feeder pillar box (KIOSK) outdoor type plateform mounted suitable for 415 volts 3 phase 4 wire 50 Hzs AC supply system having bus bar chamber with insulated aluminium bus bar 500 Amps rating installed on porcelain insulators. The panel shall be dust and virmin proof IP 65 cass protection and made of 3.15mm CRCA MS sheet and 40x40x6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer inside, front opening type with provisions for cable entry with double door shutter and locking arrangement including probision of 65mm godrej freedom lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The shouild be suitable for housing in and including the following
(a) INCOMING :
(i) MCCB 4 pole 200 Amps rating and repturing capacity 35 KA - 01 No
(iv) CTs with ratio 100/5 class ISI marked - 01 Set of three
(v) LED type indicating lamp (R.Y.B) - 01 Set of three
(b) OUTGOING
(i) Star delta starter for 80 HP pump - 02 No
(ii) Star delta starter for 25 HP pump - 02 No
(iii) DOL starter for 7.5 HP pump - 01 No
(ii) MCCB 4 pole 415 volts 100 Amps 01 No
(iii) MCB 2 pole 32 Amps : 01 No ( for light and power/socket points)
(EXTERNAL ELECTRIC SUPPLY)
Supply, installation, testing and commissioning of Compact Sub Station of 11 KV/433 Volts equipped with 500 kVA Cast Resin Transformer, 2 way 11kV Ring Main Unit consisting of 1 no. 630A at 11kV fault making load breaking switch with one No tee-off as SF6 insulated Vacuum Circuit Breaker and with 800 Amps Air Circuit Breaker as secondary side control as detailed below :-
HT Switch gear (Inside CSS) Two way 11KV Non-Extensible Ring Main Unit Compact switchgear consisting of 630 A , One numbers fixed manual fault making / Load break Switches & one numbers fixed manual SF6 insulated vacuum circuit breakers. SF6 insulated VCBs with self- powered relay having Transformer protection, over current and earth fault protection. Interconnection between RMU and transformer shall be using suitable Aluminum unarmored 95 sq.mm 3 core or 3X1CX95 Sq.mm XLPE cable. Incomer / outgoing Load break switches shall be suitable for termination of 2run X 3C X 95 Sq.mm aluminum armored XLPE Cable. 500 KVA, 11KV / 415V, DYn11, Air Natural cooling Cast Resin Dry Type Transformer with off circuit tap links 5% to -5% @ 2.5% on HT side of transformer with WTI Scanner with Alarm and trip contact.. Digital Multifunction Meter with A,V,KW,KWH,PF, Cl-0.5 and 3 Nos 11KV Single core Ring type metering CTs with 50/1 A for transformer feeder. One no 3 phase, HT PT Panel common for the complete RMU with control MCB, 6A, SP, indoor LV panel with Aluminum Bus bars, fabricated using CRCA sheet steel, Ingress Protection IP4X, Compartmentalized complete with internal wiring.
LT Switchgear Incomer/Alternate: 800 A, TPN, 415V, 3P, 50Hz, 50KA, Fixed manual type ACB with Microprocessor based O/L, S/C, E/F release.Rated Insulation and two Nos MCCB 500 Amps 4 pole 50 KA and two Nos MCCB 400 A 4 pole 50 KA for outgoing supply (incl one spare MCCB) LT Switchgear should be suitable for termination of 2 run X 3 ½ C X 300 Sq.mm aluminum armored Cable.Qty: 2 sets ( one for incomer from Transformer and other for Alternate Enclosure :- Outdoor type enclosure having modular construction of Galvanized Sheet Steel. The degree of protection for HT & LT switchgear compartment shall be IP54 & degree of protection of transformer compartment of the enclosure shall be minimum IP23. The enclosure exterior shall be painted with polyurethene paint / powder coated and tropicalized to Indian weather conditions. Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door-operated switch shall be provided for each compartment. Structure of the substation shall be able to withstand the gross weight of all equipment. It should be possible to transport the equipment along with transformer, RMU & LT Panel from one site to another. Complete in all respect including excavation and earth work and PCC foundation as per manufacturers recommendation.
Supply installation testing and commissioning factory made and tested (incl CPRI type test certified) LT feeder pillar box (KIOSK) outdoor type plateform mounted suitable for 415 volts 3 phase 4 wire 50 Hzs AC supply system having bus bar chamber with insulated aluminium bus bar 800 Amps rating installed on porcelain insulators. The panel shall be dust and virmin proof IP 65 cass protection and made of 3.15mm CRCA MS sheet and 40x40x6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer inside, front opening type with provisions for cable entry with double door shutter and locking arrangement including probision of 65mm godrej freedom lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The shouild be suitable for housing in and including the following :-
Incomming:-
(a) ACB with microprocessor base 800 Amp 4 pole, 415 volt -01 Nos
(b) MCCB 4 Pole 500 Amp 50 KA, rating capacity 2 Nos
(e) CTs with ratio 400/5 class ISI marked - 01 Set of three
(f) LED type indicating lamp (R.Y.B) - 01 Set of three
(g) OUTGOING
(h) MCCB 4 pole 415 volts 400 Amps rating and repturing cap 36 KA - 01 No
(i) MCCB 4 pole 415 volts 250 Amps rating and repturing cap 36 KA - 02 No
(j) MCCB 4 pole 415 volts 160 Amps rating and repturing cap 36 KA - 02 No
(k) Astronomical timer switch with contractor 32 A fitted inside steel end : 01 No
Supply installation testing and commissioning factory made and tested (incl CPRI type test certified) Automatic power factor correction (APFC) (KIOSK) outdoor type plateform mounted suitable for 415 volts 3 phase 4 wire 50 Hzs AC supply system having bus bar chamber with insulated aluminium bus bar 600 Amps rating installed on porcelain insulators. The panel shall be dust and virmin proof IP 65 cass protection and made of 3.15mm CRCA MS sheet and 40x40x6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer inside, front opening type with provisions for cable entry with double door shutter and locking arrangement including probision of 65mm godrej freedom lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The shouild be suitable for housing in and including the following :-
INCOMING :
(a) MCCB 4 pole 500 Amps rating and repturing capacity 50 KA - 01 No
(d) CTs with ratio 400/5 class ISI marked - 01 Set of three
(e) LED type indicating lamp (R.Y.B) - 01 Set of three
(f) MD—XL Double metalized paper (Extra Low Loss) Capacitor for 3 phase 440 V & 50 Hz system for permissible non- leaner load 20% of capacity 50 (25 x 2) KVAR capacity- 02
(g) 40 (20 x 2) KVAR capacity- 02
(h) 25 KVAR capacity- 02
(i) 20 KVAR capacity- 01
Supply installation testing and commissioning factory made and tested (incl CPRI type test certified) LT feeder pillar box (KIOSK) outdoor type plateform mounted suitable for 415 volts 3 phase 4 wire 50 Hzs AC supply system having bus bar chamber with insulated aluminium bus bar 600 Amps rating installed on porcelain insulators. The panel shall be dust and virmin proof IP 65 cass protection and made of 3.15mm CRCA MS sheet and 40x40x6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer inside, front opening type with provisions for cable entry with double door shutter and locking arrangement including probision of 65mm godrej freedom lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The shouild be suitable for housing in and including the following :-
(a) INCOMING :
(i) MCCB 4 pole 400 Amps rating and repturing capacity 50 KA - 01 No
(iv) CTs with ratio 400/5 class ISI marked - 01 Set of three
(v) LED type indicating lamp (R.Y.B) - 01 Set of three
(b) OUTGOING
(i) MCCB 4 pole 415 volts 160 Amps rating and repturing cap 35 KA - 02 No
(ii) MCCB 3 pole 32 Amps : 01 No ( street light)
(iii) MCCB 4 pole 100 Amps repturing cap 25 KA - 01 No
(iv) MCCB 4 pole 63 Amps repturing cap 25 KA - 02 No
(v) Astronomical Time switch with contactor 32A fitted inside steel encl : 01 No
Supply and fix LED street light fittng, suitable for 60 Watts versatile pressure die cast aluminium IP65 roadway luminaire with high power LEDs as light source and electronic divert complete all as specified and as directed
Material and labour for shifting of existing compact/package type Sub Station of any capacity/make after disconnection of all HT/LT cableand earthing connections within 60 Mtr distance by using lifting crane of suitable capacity, including removing and relaying/reconnecting all HT/LT cables for restoring electric supply all as directed by Engr-in-Charge (Note : Excess qty of HT/LT cables required at site for rerouting of cable shall be measured and paid separately under relevant items)
Supply, installation, testing and commissioning of 11 KV SF6 gas insulated vacuum Ring main unit. RMU with front cable termination well protected with Pad-lock, interlock and earthing facilities. HT 11 KV One incoming two outgoing SF6 filled load break switch each of 630 Amps outdoor type. The RMU shall be IP56 (minimum) outdoor type comprising of one (01) no Load Break Switch and two (02) nos. of VCB and should be tested in accordance to IS/IEC 62271 or equivalent standards.The RMU shall consist of the following configurations: (i) 1 Nos. 630A, 11kV Load Break Switch with integral Earth Switch (ii) 2 No. of 630A, 11kV Feeder Vacuum Circuit Breakers with microprocessor based IDMT 2 O/C + E/F numerical relays. (iii) 1 Nos. Bus PT module, 11kV/110V, and burden 50VA Class 1P&3P castresin type. PT should be equipped protection HRC Fuse on HT side & MCB/Fuses on LT side. (iv) Voltage presence indicating system (VPIS) in all modules. (v) Digital Multifunction meter showing voltage, current, frequency, watt & VAR along with cast resin CT ratio 100/1 Amp, Class 1 metering, Burden 2.5VA, protection Class 5P10, 2.5VA on each Outgoing breaker feeder (vi) Provision of 24-30V DC power supply for auxiliary power supply system, (vi) The terminals of the switches shall be suitable for installation of XLPE cable sizes of 3C 11kV 300 sqmm.
(vii) All live parts of the switchgear and busbars assembly shall be grouped together and SF6 gas insulated in a gas-tight stainless steel chamber, and sealed for life. The RMU to withstand a short circuit current of 21 kA for 3 second or more at 11 kV nominal voltage. Current Rating: Load break switches (Isolator): 630 A, 11kV Circuit Breaker : 630 A, 11kV Bus Bar : 630 A, 11kV complete in all respect including earth work and PCC foundation as per manufacturers recommendation.
(RAIN WATER HARVESTING SYSTEM)
M&L for drilling 300 mm dia borehole by DTH cum Rotary at any depth below the ground level in any kind of rock/soil up to 40 m depth including disposal of surplus soil to a distance not exe 50 mtr away all as specified and directed.
S&F self preforted unplasticised PVC pipes 250 mm dia of pressure rating 10 kg/Sqcm fixed complete to wall or ceiling or in floors complete all as specified.
(FIRE FIGHTING E/M INCLUDING FIRE ALARM SYSTEM)
Providing ,fixing,testing and commissioning of 16 Zone window type main fire alarm panel for Manual call box, power card rectifier relay for actuation of hooter on respective floor, adjustable timmer, sealed maint free battery 15 AH 24 Volts capable of running minimum of 12 hours with battery charger. LED indicators for fire signal of individual unit. Each fllor shall have a separate relay for actuation of sounder. through tone generator and PA panel. Panel shall also be provided with key operated auto dialer and connection to P&T lines with 4 auto programmed into the panel. complete in all as directed.
Supply, installation, testing & commissioning of Horizontal mounted end suction / spit casing Electric Motor driven Main Fire Pump /Standby Fire Pump of capacity 2280 LPM at 88 Mtrs head with synchronous speed of 1500 RPM suitable for automatic operation ,high efficiency with bronze impeller , TEFC motor , with ERW pipe Class C of 150 mm dia suction pipe , foot valve, ERW pipe Class C 150 mm dia delevery pipe up to MS Header with NRV and butterfly valve,common base frame , foundation bolts etc complete as specified along with Electrical/Control panels, power and control cabling ,cable trays, and all accesories as specified and as shown on drawings and complying to specifications, drawings, relevant standards and authority regulations. complete all as specified and directed Notes: Rates for Itme No 1 to 2 are inclusive of followings:- (a) Supplying, installing ,testing and commissioning of Pressure gauges of suitable range for pump sets and Fittings like unions / colours / reducers etc. (b) Supplying, installing ,testing and commissioning of Pressure switches suitable for automatic operation of pump sets
Supply, installation, testing & commissioning of multistage Electric Motor driven Joickey Fire Pump of capacity 180 LPM at 88 Mtrs head speed of 2900 RPM suitable for automatic operation ,high efficiency with bronze impeller , TEFC motor , with MS Heavy duty pipe of 80 mm dia suction pipe , foot valve, MS Heavy duty pipe 80 mm dia delevery pipe up to MS Header with NRV and butterfly valve, common base frame , foundation bolts etc complete as specified along with Electrical/Control panels, power and control cabling ,cable trays and all accesories as specified and as shown on drawings and complying to specifications, drawings, relevant standards and authority regulations. complete all as specified and directed
Supplying , fixing, testing and commissioning of MS Header made out of Heavy duty ERW pipe of size 400 mm dia with end plates of 4 Mtrs length with inlet connection 150 mm dia - 2nos, 80 mm dia -1 no, connection with Air cushion Tank with suitable size of heavy duty pipe and outlet connection 100 mm dia -2 nos on PCC Pillars complete all specified and directed
Air Vessel 3m³ capacity having 450mm O.D x 1.5m cylindrical height, made out of 12mm thick Dishend and 10mm thick Shell of I.S:2062 Gr-A/B having dish end welded with shell manufacturing as per Design code I.S:2825, Class II suitable for working pressure 9 Kg/cm², Hydrotested at 21Kg/cm², Joint efficiency 0.85, Radiography longitudinal seam 100%, Circumferential seam 10% spot with all necessary valves & fittings complete all specified and directed
Providing and fixing set of wall mounted signages of Zinc Sulphide Photo luminescent coating on 6mm thick acrylic sheet each of size 15cm x 30cm and consisting of signage on half side and arrow on other half. Each set of signages made separately on each sheet of size 15x30 cm each comprise of "EXIT,STAIRCASE,MANUAL CALL BOX, HYDRANT, EXTINGUISHER
Supplying, laying, jointing and commissioning of M.S. "C" class pipe of size 100 mm dia conforming to IS: 1239 with all accessories like all fittings to IS: 1239 with all accessories like all fittings (standard MS fittings with welded joint shall be used on the pipes) including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer, including supporting laid in trenches /through hume pipe and with anti corrosions treatment (using anchor fastners) as per specification complete with painting of one coat primer and 2 or more coats of synthetic enamel paint of approved make / shade complete as per specification complete. All hangers, clamps, brackets etc. shall be of galvenized iron, welding of any kind on the galvenised support/ hanger not be permitted.
Providing and laying of NP3 class R.C.C Hume pipe (IS-458) with mortise - tension jointed with cement and with RCC collar to cover and overlap the joints laid to correct levels below ground of size 300 mm dia. For underground hydrant pipe at road crossings etc complete all as specified and directed
(b) Single phase centrifugal type cross flow blower 270 cu meter/hour-02 Nos. (c) Electrically operated with electric motor AC 415 Volts, 3 Phase 50 HZ of suitable capacity as per as Per IS(minimum efficiency class equivalent to IE 2 and operating gearless box with independent main sheave rim. (d) Electric cabling and wiring in FRLS copper cable including all necessary PVC conduits ISI marked of suitable size (e) Micro processor based VVVF type main controller with closed loop system. (f) Type of signal system FIGS fixtures with dot matrix display and car position indicator in car all fixture in SS face plate (both insided/out-side).All Buttons should be with brail marking and luminous. (g) Provn of travelling cable with copper conductor FRLS of suitable size & core or required wiring to intercom speaking, connect to complete cell and provn of through & other accessories. (h) Inbuilt ARD (Automatic Rescue Device) with maintenance free batteries operated to bring the car cage to the nearest floor level in case of power failure, which includes power failure of one or more phase. Emergency light and at least one fan inside the lift car shall be operational till the rescue operation and an audio and visual indicator shall be provided inside the lift car to alert the persons trapped inside they are being rescued.
(j) Provision of governor grooved belt and along with belt monitoring device which can ensure to prevent from any breakage of belt and taking elevator to nearest landing of suitable size, buffer springs as per manufacture's design, car cabin having powered doors and inspection box at top of the car cabin, compact high efficiency drive combined with suspension Traction Media Technology. (k) Provision of safety guarding equipments such as 02 Nos pit switches controller, guarding pit, pulley, guarding pit ladders, facia plate to cover free space between car cabin and hoist way & switches. (l) Door Sensor not less than 74 beam, 2D infra red full length. (m) Provision of fire man switch complete at ground floor fitted in box including SS face plate. (n)Provision of "Press and Speak" system to be connected with lift complaint cell compatible with exchange. Provision of Automatic call registration in case of breakdown (o) Do's & Don’ts chart on stainless steel to be installed inside the car cabin. (p)A three Pin plug socket with switch for hand lamp shall be fitted top of the lift car for use by person working there on.
(a) LED Light Ultra slim decorative aluminium casted, recess mounted square fixture in white with opal diffuser and separate electronic driver, suitable for low depth ceiling -12W BLAZE SQUARE with complete accessories including necessary wiring - 04 Nos. Make:- Havells (cat part no. LHEBMFP6IZ2W012) or equivalent model in CG/Philips. (b) Single phase centrifugal type cross flow blower 270 cu meter/hour-02 Nos.(c) Electrically operated with electric motor AC 415 Volts, 3 Phase 50 HZ of suitable capacity as per as Per IS(minimum efficiency class equivalent to IE 2 and operating gearless box with independent main sheave rim. (d) Electric cabling and wiring in FRLS copper cable including all necessary PVC conduits ISI marked of suitable size (e) Micro processor based VVVF type main controller with closed loop system. (f) Type of signal system FIGS fixtures with dot matrix display and car position indicator in car all fixture in SS face plate (both insided/out-side).All Buttons should be with brail marking and luminous. (g) Provn of travelling cable with copper conductor FRLS of suitable size & core or required wiring to intercom speaking, connect to complete cell and provn of through & other accessories.
(h) IInbuilt ARD (Automatic Rescue Device) with maintenance free batteries operated to bring the car cage to the nearest floor level in case of power failure, which includes power failure of one or more phase. Emergency light and at least one fan inside the lift car shall be operational till the rescue operation and an audio and visual indicator shall be provided inside the lift car to alert the persons trapped inside they are being rescued. (j) Provision of governor grooved belt and along with belt monitoring device which can ensure to prevent from any breakage of belt and taking elevator to nearest landing of suitable size, buffer springs as per manufacture's design, car cabin having powered doors and inspection box at top of the car cabin, compact high efficiency drive combined with suspension Traction Media Technology. (k) Provision of safety guarding equipments such as 02 Nos pit switches controller, guarding pit, pulley, guarding pit ladders, facia plate to cover free space between car cabin and hoist way & switches. (l) Door Sensor not less than 74 beam, 2D infra red full length.
(m) Provision of fire man switch complete at ground floor fitted in box including SS face plate. (n)Provision of "Press and Speak" system to be connected with lift complaint cell compatible with exchange. Provision of Automatic call registration in case of breakdown (o) Do's & Don’ts chart on stainless steel to be installed inside the car cabin. (p)A three Pin plug socket with switch for hand lamp shall be fitted top of the lift car for use by person working there on.
DG SET
Supply, installing, commissioning and testing complete of Manufacturer or OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 200 KVA (160 KW),or nearest higher rating 415 volts (AC 3 Phase, 4 wire system of supply), 50 Hz to operate at a powers factor of 0.8. The DG set shall consist of a diesel engine coupled through flexible coupling to a matching alternator and mounted on AVM pads (As per respective Mnufacturer Design ) on a common base frame all as specified complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete and shall comprise of the following: -
(a) ENGINE (PRIME MOVER): Diesel engine 1500 RPM of suitable HP as recommended by manufacturer but not less than 243 BHP (at NTP) water cooled, Turbocharged aircooled, electric battery start, confirming to BS 5514,BS 649 and IS 10000 complete with fly wheel and all standard fittings/ fixtures as per manufacturing practice including suitable engine control panel with tachometer, lub oil temp & pressure gauges, water temp gauge, and frequency meter (digital type) (including safety shutdown contents) and also including self starter, dynamo, fuel tank etc.
(b) ALTERNATOR : AC alternator, self excited, self regulated, self ventilated, brushless design, conforming to BS 2613 / 5000, 3 phase , 415 volts, 4 wire rated line current 2086 amps for output PF 0.8, 1500 RPM, insulation class ‘H’ Temprature Reise H @ 40 Deg C; Enclosure IP 23 confirming to IS-4722 / BS-2613 complete with AVR with + 1 % voltage regulation, directly coupled to and match the above engine.
(c) Anti-vibration pads for mounting engine – alternator assembly on the base frame/ plate.
(d) BASE FRAME:One no. MS Fabricated adequately machine Channel Common Base Frame with lifting facility,pre-drilled foundation holes suitable for permanent installation on concrete foundation for direct grouting or on anti-vibration mountings which will be suitable to receive the offered engine and alternator duly coupled through a flexible coupling. A suitable coupling guard shall also be provided
(e) Silencer: Critical Grade and exhaust gas piping system of suitable dia MS pipe of 'B' class of required legth as per CPCB norms with necessary bends, supports and clamps anti vibration mounting inulated with rockwool 50 mm thick with wire mesh and aluminium clading complete all as specified
(f) Fuel tank of 375 Litres, made of 14 SWG CRCA MS sheet, duly powder coated and provided with float, gauge and fuel float switch.
AMF Panel:-
Fabricating, Installing, Testing & Commissioning of automatic mains failure control including auto by-pass panel, suitable for 200 KVA silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyzer to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including for following:
MCCB 250 Amps. 4 Pole
(a) 2 Nos over voltage relay, 2 Nos reverse power relay and 2 Nos under voltage relay.
(b)3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering
(c) Energy analyzer unit to indicate current voltage frequency power factor and KWH
(d) Indicating lamps for load on mains and load on set
(e)Fuse for instruments
(g) Main supply failure monitor
(h) Supply failure timer
(i)Restoration timer
(j)Control unit with three impulse automatic engine start/ stop and failure to starty lockout
(l) Impulse counter with locking and reset facility
(i) Audio/ Video annunciation for
(ii) High water temperature
(iii) Low lubricating oil pressure
(iv) Engine over speed
(v) Engine fails to start
(vI) Full load/ maximum load warming
HOT WATER SUUPLY
Supply and fix water heater storage type, electric, capacity 25 Ltrs, BEE 5 star rated.complete including grouting of nuts bolts etc and PVC connection for inlet and outlet supply complete all as specified.
AVIATION LIGHT
S & F Aviation obstruction light (Twin) aviation Yellow painted die cast Al alloy housing, red coloured polycarbonate dome and accessories suitable for LED 2x6 watt complete all as specified and directed.
M&L for chemical earthing complete with earth electrode made of high tensile low steel circular rods, molecularly bonded with copper on outer surface to meet the relavent indian standards and shall be of the approved make & design. the earth electrode shall confirm IS and of minimum 17 mm dia and minimum 2 mtr long & thickness of copper bonding minimum 250 microns. hole of 100 mm to 120 mm dia shall be augured to a depth of about 2.5 mtr. earth electrode shall be placed into the hole. by penetrating it into the soil gently diving on the top of the rod, so that min. 150 mm of the electrode shall be ibserted in the natural soil/ present soil. earth enchancement material (minimum approx. 20 Kg) shall be filled in to the augured hole in slurry from and allowed to set. after the material get set, the diameter of composite structure (earth electrode + earth enchancement material) shall be of minimum 100 mm dia covering entirelength of the hole. remaining portion of the hole shall be covered by backfill soil/ material. A copper strip of 150mmx25mmx6mm shall be exothermically welded to main earth electrode for taking the connection to the main equi-potential earth bus bar /ICT centre. multi strand single core PVC insulated 10 Sqmm copper cable connecting to main earth electrode. earth enhancement material consist of Graphite and portland cement. Bentonite content shall be negligible. high conductivity & humidity retention capability, non corrosive in nature having low water soiubility but highly hygroscopic. Inspection chamber size of 300x300x300 mm (inside dimension) box (concret / Iron) with smooth finish shall be provided on the top of the pit. A concrete /Iron lid painted black with pulling hooks, shall be povided to cover the earth pit. copper lugs with stainless steel nut and bolts complete all as directed.
City Promoter and Buildwell Pvt. Ltd.
SHIVALAYA CONSTRUCTION CO. PVT LTD
B D Raizada Projects Pvt Ltd
Som Projects Pvt Ltd
surendra infrastructure pvt ltd
Hariom Projects Pvt Ltd
Inderjit Mehta Constructions Private Limited
Bidder Name
Ktech Engineer Builders Co. Pvt. Ltd
B D Raizada Projects Pvt Ltd
Inderjit Mehta Constructions Private Limited
City Promoter and Buildwell Pvt. Ltd.
Hariom Projects Pvt Ltd
surendra infrastructure pvt ltd
Som Projects Pvt Ltd
SHIVALAYA CONSTRUCTION CO. PVT LTD
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid