Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.1 LAccepted-AOC POCKET A 2 310 SECTOR 08 ROHINI NEW DELHI 110085 | NEW DELHI | NORTH WEST DELHI | DELHI | 110085 | L1 | Accepted-AOC Being lowest and reasonable tender | |
| 2 | L2₹70.0 L+₹5.9 L (9.16%)Rejected-Finance RZ 10 TF KH NO 641 INDRA PARK MAIN PALAM ROAD NEAR MANGAL BAZAR CHOWK NEW DELHI 110045 | NEW DELHI | NEW DELHI | DELHI | 110045 | L2 | Rejected-Finance Being second lowest tender |
Tender Value
₹71.5 L
EMD Value
₹1.3 L
Closing Date
29 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF PALAM
CWE(AF) PALAM, DELHI CANTT-10
PROVN OF LIFT FACILITY AT AFCAO MAIN BUILDING AT SUBROTO PARK UNDER GE (AF) SUBROTO PARK, DELHI CANTT-10
2023_MES_588905_1
CWE/PM/SP-01/2023-24
Open Tender
Civil Works
Item Rate
270 days
SUBROTO PARK
As per tender documents
10 documents required · 10 mandatory
₹1,000
GE AF SUBROTO PARK
₹1.3 L
30 Jun 2023
11 Apr 2023
31 May 2023
11 Apr 2023
29 May 2023
15 May 2023
Amount
BUILDING WORKS INCLUDING EXCAVATION/SITE CLEARANCE WORKS
M&L for surface dressing n.exc 150mm deep in hard/dense soil complete all as specified and directed.
M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed.
M&L for Excavating in trenches, n exc 1.5 m wide and exc 1.5 m in depth; for foundation, etc. n exc 10 sq m on plan and getting out in hard/dense soil complete all as specified and directed.
M&L for laying PCC 1:4:8 type D-2 (40 mm graded aggregate) as in steps, ramps,foundation filling and mass concrete complete all as specified and directed.
M&L for RCC M-25 (using 20 mm graded stone aggregate ) as in foundations incl footings, plinth beams, bases for columns , under reamed piles and mass concrete complete all as specified and directed.
M&L for Reinforced cement concrete (design mix) M-30 (20mm graded stone aggregates) as in columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for Reinforced cement concrete (design mix) M-30 (20mm graded aggregates) as in walls, retaining walls, basement walls, ballast walls and the like; any thickness ; above top of footings ; including attached pilasters and buttresses complete all as specified and directed.
M&L for RCC M-25 (using 20 mm graded stone aggregate ) (design mix) in chajjas complete all as specified and directed.
M&L for RCC M-25 (using 20 mm graded stone aggregate) in lintels, beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for Reinforced cement concrete (design mix) M-25 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished surfaces of concrete (Flat) complete all as specified and directed.
M&L for Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc. vertical or to batter, rough finished surfaces of concrete (flat) complete all as specified and directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), rough finished sufaces of concrete (Flat) complete all as specified and directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc , rough finished surfaces of concrete (flats) complete all as specified and directed.
M&L for Formwork to rough finished surfaces of concrete (Flat) of staircases with sloping or stepped soffits including risers and stringers (excluding landing) complete all as specified and directed.
M&L for Formwork to rough finished surfaces of concrete (square, rectangular or polygonal) sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
M&L for Formwork to edges of rough finished surfaces of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
M&L for brick work with sub class'B' bricks using old size bricks, straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed.
M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for rendering 5 mm thick on fair faces of brick work or concrete surfaces of ceiling in CM 1:3. finishing even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in CM 1;4 on brick work or concrete surfaces of walls in 2 layer (10mm+5mm) using WPC for top layer of plaster, finishing even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick on brick work or concrete surfaces on walls in CM 1:6 finishing even and smooth without using extra cement complete all as specified and directed.
M&L for three coats of white wash on new plaster surface of ceiling including preparation of surface complete all as specified and directed.
M&L for providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed.
M&L for preparing new plastered surface of walls and applying a coat of primer and distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification, two or more coats on new work complete all as specified and directed.
M&L for finishing walls with acrylic smooth exterior paint of required shade as in new work (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type-B-1 in under floor using 20mm graded aggregate complete all as specified and directed.
M&L for vitrified ceramic tiles dark shade / double charged / ultra charged 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles and including 15mm thick screed bed in CM 1:4 complete all as specified and as directed.
M&L for Vitrified Ceramic tiles dark shade / double charged /ultra charged 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, as in vertical surfaces such as skirtings, dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles and including 10mm thick rendering in CM 1:3 complete all as specified and as directed.
M&L for granite (of any type) tiles 20mm thick machine cut, as in steps, jambs, pillars, window cills, cooking platforms and like, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over and including 20mm thick screed bed or bedding layer in CM 1:4 complete all as specified and directed.
M&L for 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over and including 15mm thick rendering in CM 1:3 and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed.
M&L for 20-22mm thick mirror polished Kota stone of size 450 x 550mm as in flooring over 20mm thick cement screed bed or bedding layer in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding and polishing complete all as specified and as directed.
M&L for 20-22mm thick mirror polished Kota stone of size 450 x 550mm as in riser of steps, skirting, dado and pillar laid over and including 10mm thick rendering in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding and polishing complete all as specified and as directed.
M&L for chequered cement concrete tiles of size 300 x 300mm x 25mm thick set, jointed and pointed in neat cement slurry and mixed with pigment in floor over and including 20mm thick screed bed or bedding layer in CM 1:4 over sub base complete all as specified and as directed.
M&L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete for ATT(Anti termite treatment) all as specified and directed.
M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (area of the sub structure in contact with backfill to be measured) complete for ATT all as specified and directed.
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete for ATT all as specified and directed.
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete for ATT all as specified and directed.
M&L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete for ATT all as specified and directed.
M&L for two coats of synthetic enamel paint on steel surfaces over 10cm width or girth over a coat of red oxide primer including preparation of new surfaces complete all as specified and directed..
M&L for mild steel bars TMT Bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing complete all as specified and directed.
M&L for mild steel bars TMT Bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing complete all as specified and directed.
S&F for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars barred iron doors ladders framed balusters walk ways railings framework of water tanks and similar work type conforming to Fe.290.Gde-E-165 as specified complete all as specified and directed.
S&F for colour coated galvalume aluminum zinc coating GI based corrugated/ style pattern steel sheet 0.50mm thick fixed to steel frame using L or J bolts with washer in roofs including crumping of corrugated galvalume sheet and making good joint frame, complete all as specified and directed.
S&F for aluminium anodized powder coated window double shutters glazed and gauged of stainless steel wire cloth having nominal dia of wire 0.36mm and average width of aperture 1.40mm along with aluminium section with 50 micron anodizing size of frame 125x44.5mmx16 gauge having size of shutter, top/ bottom/central rail shall be 44.5x44.5mm x16 gauge aluminium section with 50 micron anodizing and 5.5mm thick black/ tinted sheet glass to be fixed on glazed portion including aluminium grill and stainless steel hooks and eye to be provided as stay of shutters, etc. complete including necessary jointing cleats, glazing clips, rubber packing, aluminium snap beading, screws anodized aluminium fittings such as peg stay 150mm long (1 No. for each leaf), hinge type B-21 of 100mm long (2 No. for each leaf), suitable handle (1 No. for each leaf) and 100mm aluminium tower bolts (2 No. in each leaf), complete all as specified and as directed. NOTE : Cost of black/tinted sheet glass, stainless steel wire cloth, jointing & packing materials, anodized aluminium fittings, etc. shall deemed to be included in the quoted unit rate.
M & L for powder coated aluminium (minimum thickness of polyester powder coating 50 micron) work for fixed frame portion and shutters of doors, sliding door (any track), openable / sliding windows, ventilators, partitions sliding/openable with extruded built up standard tubular section/appropriate Z section and other section conforming to IS : 733 and IS 1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required EPDM rubber / neoprene gasket roller etc aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ gauged / paneling, CP brass / stainless steel screws, complete all as specified and directed.
S&F for 5mm thick float glass, tinted/smoked shape fixed to frame/shutter for aluminium door/window/partition etc including aluminium powder coated snap beading and rubber gasket, complete all as specified and directed.
S&F for 140mm size floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and directed.
S&F for 180mm size powder coated (any tint) aluminium "American Handle" fixed to aluminium door with suitable screws, complete all as specified and directed.
S&F for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed, complete all as specified and directed.
S&F for Aluminium alloy, anodised, sliding door bolts 300mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy 12mm dia, complete all as specified and directed.
Supply and Fixing, Aluminium anodised, barrel tower bolts 200mm long, powder coated, of extruded section and fixed, complete all as specified and directed.
S&F 100mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed.
S&F Aluminium handles, cast type, anodised 100mm in size fixed with screws complete all as specified and directed.
M&L for Plain Cement Concrete, Type B0, (1:2:4) (12.5mm graded aggregate) as in padding, roof kerbs or mud stops, rounded or chamfered on edges complete all as specfied and directed.
M&L for rendering 10mm thick in CM 1:3 over roof surfaces including mixing with required water proofing compound as per manufacturer's specification and finishing concrete surface even & smooth with using extra cement complete all as specified and directed. Note : Water proofing compound shall be paid for separately.
Supply only Liquid water proofing compound complete all as specified and directed.
M&L for applying a coat of bitumen primer @ 0.3 Kg /sqm conforming to IS : 3384 and laying 3mm thick APP modified water proofing membrane reinforced with non woven polyester mat having softening point not less than 150 degree centigrade, having tensile strength 650 N/Sqcm in longitudinal & 400 N/Sqcm in transverse direction by torch method with min 100 mm side lap and 150 mm end lap followed by application of a coat of hot blown bitumen 85/25 grade @ 1.2 kg per sqm and blinded with clean dry sand @ 0.5Kg/sqm over the APP membrane complete all as specified and as directed.
S&F for Plain, galvanised mild steel sheeting 0.80mm thick in covering to crumple joint, steeped flashing with welded or soldered or by fixing screw/nut bolts joints are provided complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 type-C-2 (40mm graded aggregate) in plinth protection complete all as specified and as directed.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface as in plinth protection, ramp and under flooring complete all as specified and as directed.
M&L for 100 mm thick PCC type B-1, 1:2:4 (20mm graded stone aggregate) as in flooring of ramp and finishing cement concrete surface even and smooth without using extra cement including spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all as specified and as directed.
M&L for collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc: as specified erected in position and securing runners with holdfasts and brackets complete all as specified and as directed.
INTERNAL E/M SERVICES
Material and labour for point wiring with single core PVC sheathed 1100 volt grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, with GI saddles GI screws, rawl plugs (concealed conduit wiring in walls ) including Tee, Junction boxes and provision of 3 mm thick plastic laminated sheet cover of suitable size on existing terminal boxes with new brass screws for mounting switches sockets and regulators and drawing continuous earth wire with and including PVC sheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for one light/Fan/exhaust fan point controlled by one Switch.
All as per Srl item No 2.01 here-in-before but for 3 pin 5 Amps socket out let on independent board and different wall with 2.5 sqmm cable controlled by one switch complete all as specified and directed.
All as per Srl item No 2.01 here-in-before but for one power point 6 pin 15 Amps socket out let with 4 Sq mm stranded copper conductor cable PVC insulated including earth wire 4 Sq mm copper conductor cable connected to earth dolly complete, all as specified and directed.
Supply and fixing for switch piano flush type 5 Amps, single pole one way complete, all as specified and directed.
Supply and fixing for socket out let 3 pin 5 Amps, flush type complete, all as specified and directed.
S&F for switch piano flush type single pole one way 15 Amps complete, all as specified and as directed.
Supply and fixing for socket outlet 2 in 1, 6 pin 5/15 Amps, flush type complete all as specified and as directed.
Supply and fixing for ceiling rose, surface type, 65mm x 50mm, 2 to 3 terminal complete all as specified and as directed.
Supply and fix of LED complete fitting including batten and T-8 Retro LED Polycarbonate 1x20 W. Appx 4 feet long, environment friendly including electric connection with using 2 core flexible copper conductor cable 23/0.0076 from ceiling rose to tube light fitting complete fitting with all accessories and following specifications all as directed : - (a) Lumen system efficacy of luminiare should be minimum 100 Lumen per watt (b) Input Voltage Range : 140 to 270 Volt (c) Temperature operating Range : Minus 10 degree centigrade to plus 45 degree centigrade (d) Power Factor : Min 0.95 (e) THD : Max 10 % (f) IP rating : IP 20 (g) CRCA pre coated housing with two coloured plastic end cap (h) LED driver of the Make as of the luminiare (j) LED driver should be complete with all protections viz open / short circuit protection over voltage protection all as standard design of manufacturer (k) Surge protection minimum 2.5 KV (l) CCT : 6500 K (m) CRI : More than 80 (n) Rated life time : 50000 Burning hours (Avg 10 to 12 hrs daily)
Supply and fixing energy efficient LED building security light fitting of 35 watt pressure die cast aluminium housing / body, heat resistant clear toughened glass better optics for uniform distribution street / roadways luminiare with driver, lamp bracket with impact and corrosion resistant including electric connection complete fitting with all accessories and following specifications and all as directed : (a) Lumen system efficacy of luminiare should be minimum 100 watt lumen per watt (b) Input voltage Range : 140 to 270 volt (c) Temperature operating range : Minus 10 degree centigrade to plus 45 degree centigrade (d) Power factor : Min 0.95 (e) THD : Max 10% (f) IP rating : IP 66 (g) IK Rating : Min IK07 (h) Built in potted LED driver of the make as of the luminiare (j) LED Driver should be complete with all protections viz open / short circuit protection, over voltage protection, all as standard design of manufacturer (k) Surge protection 10 KA (Inbuilt + Extended) (l) CCT : 5700 K (m) CRI : More than 80 (n) Rated life time : 50000 Burning hours (Avg 10 to 12 hrs daily) (o) Lens : High efficiency wide angles lens (p) BIS Approved fixtures and driver
Supply and hanging / fixing ceiling fan 1200mm sweep AC supply (input voltage range : 120 to 280 V), BLDC type 5 star rated BEE and ISI marked super enamelled copper winding of 'B' class insulation single phase minimum 26 W (+/- 10%) temperature rise 40 degree maximum with out remote with and including operative based capacitive regulator 03 Nos blades down rod including accessories white colour total harmonic less than 10%, 5 speed hanging in position including making connection with flexible cord three twisted copper conductor of suitable size from ceiling rose to fan complete all as specified. Note : (i) Serial Number as issued by Engineer-in-charge of ceiling fan and GE office name shall also be written on fan with red colour permanent marker cost for the same shall deemed to be included in the quoted unit rate, nothing extra shall be paid on this ground
S&F heavy duty exhaust fan for shaft 450 mm (metal body)size with louvers suitable for ,1400 RPM, 90W,1710 cubic mm/hr,240V, 50 Hz single phase AC supply including fixing on wall with nut, washer etc complete and necessary electrical connection from ceiling rose to fan connecter with three core sheathed wire of required length complete all as specifed and as directed. Make- Crompton / Havells / Usha.
Supply and fix only of lift cabin fan 300mm sweep 230 volt ,50 Hz, 2200 RPM fitting suitable for Thyssenkrupp lift complete all as specified and as directed..
M & L for Load line DB suitable for 'G' frame MCCB IS : 8623 and IS : 13032 with sheet metal enclosure with double door category of protection type IP-42 factory made with tinned copper 200 Amps rated bus bar suitable for MCCB TPN 415 Volts, 4 way verticle type concealed in wall such that front cover shall be seen flush with the wall surface all as specified and directed. Make : Havells/L&T/Legrand
Supply and fixing MCB distribution board (concealed flush to wall) single pole and neutral for 240 Volts 4 way double door for mounting MCBs factory made conforming to IS 13032, fabricated out in CRCA sheet not less than 1.20 mm thick, fitted with DIN channel neutral link and 200 Amps rated bus bar. DBs shall be semi glossy finished with epoxy polyester based power paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DBs shall be double door type with hinged door worth locking arrangement, the DBs shall be same make as MCBs and shall be provided with lable marking indicating the incoming and outgoing circuits on all ways as specified, The DB shall be of IP 42 protection class all as specified and directed.
S&F of MCB single pole and neutral 32 amps working on 240 volts 50 Hz AC supply,10 KA 'C' series complete all as specified and as directed.. Make : Havells/L&T/C&S/Legrand
S&F of MCB single pole 6 to 32 Amps working on 240 volts 50 Hz AC supply,10 KA 'C' series complete all as specified and as directed.. Make : Havells/L&T/C&S/Legrand
S&F of MCB triple pole and neutral 63 Amps working on 415 volts 50 Hz AC supply,10 KA 'C' series complete all as specified and as directed. Make : Havells/L&T/C&S/Legrand
S& F of sub main wiring with two single core PVC insulated unsheathed cable 1100 volts FRLS grade with multi strand copper conductor and drawn through and including PVC conduit along with continuous earthing wire but in green colour complete on surface / concealed and connected to common earth dolly of the size 4 Sqmm ( 2 single run of 4 Sqmm and one run of 4 Sqmm as earth wire) Note : Three run of PVC cable and one run of PVC conduit shall be measured as one unit length.
Supply and fixing RCCB, 4 pole, 415 volt of capacity 63 amp, breaking capacity not less than 300mA with 10kA short circuit withstand capacity JEC-61008-I, IS-12640-I , including thimbles, nuts, bolts,washers and enclosure box with cover suitable for RCCB and connections all as specified and directed.
Supply and fix of MCCB, 415 volts, 3 pole adjustable thermal setting type 25 KA, 125 Amps complete all as specified and as directed. Make : Havells /L&T/C&S/Legrand.
Supply and installation of phase frequency corrector of capcity 25 HP of 3 phase corrector for 3 phase tower / casette / ductable Split AC and other 3 phase items , electrically controlled with interlocking system duly pre wired with multi stranded copper wire of durable rating , powder coated metalic housing with hanged door and indicator for each phase. current rate 40A- 100 A, Voltage rating 440V complete all as specified and directed.
Supply and fix of servo voltage stabilizer capacity of 20 KVA 3 phase in put range 430 V and AC output range 415 Volt ,air cooled servo stabilizer variable auto transformer+buck boost transformer+ servo motor, micro controller based digital cercuit and control, as per IS 9815 voltage correction rate 15-20 Volts/sec , ambient temperature 0-55 degree , under/Over cut off protection and overload / short circuit protection. manual bypass - changeover , input MCB /MCCB frequency Hz 47Hz to 53 Hz vector group star/star, 3 phase + neutral, output regulations +- 2 % installed in lift machine room with all necessary electrical connection complete all as specified and directed.
S & F earth continuity aluminium strip 32x6 mm or main earthing lead fixing to surface of wall or in recessed or chase or buried or drawn in conduit/ pipe or fixing to poles or any other situation for loop earthing etc. as required, complete all as specified and directed.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables complete all as specified and directed.
Supply & laying bricks, sub class 'B' burnt, old size, abutting each other with gap between adjacent brick not exceeding 10mm, laid flat perpendicular over UG cable for protection complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning LT under ground cables, 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty armoured with multistranded alumimium armoured conductors, IS - 7098 laid in trenches/ducts/fixed on poles/walls/laid under roads/paths/drain/culverts or encased in GI pipe complete all as specified and directed,cables of cross sectional area 70 Sqmm x 3.5 core.
Supply, laying, jointing, testing and commissioning LT under ground cables, 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty armoured with multistranded aluminium armoured conductors, IS - 7098 laid in trenches/ducts/fixed on poles/walls/laid under roads/ paths/ drain/ culverts or encased in GI pipe ,cables of cross sectional area 50Sqmm x 4 core complete all as specified and directed
Supply, installation,testing and commissioning of 8 gauge maintenance free earthing based on aluminium earthing electrode (Met- chem) 80 mm outer dia 3000mm long duly filled with ITPC - EECP 15 fixed with nut bolts incl excavation /earth work in any strats and PCC chamber with CI frame and cover (earth pit not less than 3 mtr deep below ground level ) with electrode surrounded by chemical (ITPC- EECP 15 ) amixture of sulphate, silca iron oxide, nickel oxide, magnesium oxide, sodium oxide, zinc oxide etc (earth enhanced compound powder) Each earth should have resistance less than 1 ohm by using earth electrode used as per the site requirement Chemical compound powder to be provide munimum 100 kg per site. aluminium strip of size 32 mmx6 mmx5mm as earth continuity conductor will be provided as required length and voltage between neutral and ground should not exceed to 3 Volt. Make : ITPC/Model Metcham CEE 80/EECP-15/Ewain
M&L for earthing complete for building with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, check nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of 22 gauge, 8 mesh per liner inch, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed.
M&L for earthing of with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below ground level connected to GI strip 32mmx6mm as earth lead by means of nuts, bolts, thimbles, check nuts, washers of GI or steel, including PCC, concrete chamber shall be PCC 1:3:6 type C-1 (using 20mm graded stone aggregate), with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in cement mortar 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) reinforced with XPM, jalli charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified or indicated including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, including all excavation and earth work & connecting the earthing to an earthing test point complete, all as specified and directed. Note: If the desired earth resistance as per equipment requirement is not obtained, the earthing shall be re-done by contractor without any extra cost to Govt.
EXTERNAL LIFT SERVICES Design ,supply, install, testing and commissioning of environmental friendly passenger machine room less elevator/lift for 08 passenger, speed upto 1.5metre/sec, Lift with Synchronous axial motor 415 V, 3 phase AC 50 Hz supply conforming to IS- 14665, suitable to serve G+04 upper floors with AC V3F drive complete with all standard accessories, simplex automatic & neutral duel controlled operation with/without attendant , entry through centre opening power doors with door drive (electric motor driven mechanism) sliding stainless steel hair line finish doors. Automatic rescue drive (ARD) system, 3D infrared door sensor in full height of door & built in announcing system without handset (04) Nos, one each in car & near ground floor landing door all as specified. Braille buttons to be integrated in COP and surface mounted LOP complete all as specified including accessories ,necessary equipment and testing from inspector of lift, Delhi. Make: ThyssenKrupp Elevator (India) / OTIS Elevator Company India Pvt. Ltd./ Schindler (India) Pvt. Ltd. / KONE Elevator India Pvt. Ltd. catering to 4 floor for opening on the same side with following:-
Item 3.00 contd.. (a) Car : Full height Silver Mirror Polish Stainless Steel Face plate with round flush Mounted white button. (b) White ,Dot Matrix Display Silver Mirror Polish Stainless Steel on Lintel Flush Mounted. (c) Other Features : Emergency Light and alarm, Emergency stop button with rechargeable battery 2 phase, Fireman drive Auto. Circuit Light & cross flow pan, Door Open and Close Button, Auto-Attendant Switch, Overload device, Inbuilt Automatic Rescue Device, Infra-Red Curtain 128 beams, single phase sensing device. (d) 02 Nos Earthing connections of the machine drive motor and control panel shall beprovided from near by earth dolly complete with suitable size copper strip. (e) Grouting suitable size MS ISMB, bolts & plates etc on existing RCC/PCC foundation all as directed complete as per manufacturer's design / requirement. (f) Provision of hoist way and Governor Rope with Governor. (g) Provision of New buffer springs for car as well as counter weight as per manufacture's design. (h) Battery operated alarm bell and emergency light. (i) Steel Wire Rope as per IS: 14665 Requirement. (j) Provision of travelling cables with copper conductor with suitable size GI/PVC through and other accessories complete. (k) Provision of any other components not considered in this schedule but required at the time of execution for smooth functioning of the lifts as a whole. (l) Car ceiling - CL88 silver mirror polish stainless steel. (m) Handrail - HR61 round tubular with straight ends alongwith silver mirror polish stainless steel finish.
Item 3.00 contd.. Safety measures as per manufacturer's design: (i) Over load relays and warning device. (ii) Contacts and fuses of suitable size and capacity. (iii) Electrical terminals, of suitable size and capacity. (iv) Limit switch with accessories on each door /cage. (v) Gravity /counter weight limit switches for top most position. (vi) Electro magnetic brake of suitable size with manned released arrangement. (vii) Phase sequence corrector & single phase preventer. (viii) Painting work with super enameled synthetic pain to all the exposed surfaces all as directed by GE/Engineer-in-Charge. (ix) Provision of necessary electrical wiring of lift well / shaft with FRLS copper cable multistranded 1.5 sq mm, LT 1100 Volts grade for minimum 5 points including bulk head luminary CFL 18 watt. Make : Bajaj / Philips / Crompton Greaves. (x) One inspection lamp and one power socket 5/15 Amps on top of car. (xi) Display of wiring diagram of lift control panel. (xii) Intercom
Item 3.00 contd.. Note :- (i) "Press & Speak" system to be connected with lift (ii) Intercom in the cabin & machine room shall be connected with existing communication network as desired. (iii) Dos & Don'ts chart on steel plates have to be installed inside car cabin. (iv) Contractors must check the details and dimensions at site before quoting the rates. The lift car door opening and landing door opening must be aligned with lift well opening so that maximum lift well opening is available at each floor. No addition/alteration to existing RCC columns will be permitted to provide necessary lift car/landing gate opening. (v) 415 Volts 3 Phase 50 Hz, AC supply shall be made available by MES and the contractor has to make necessary connections to the lift panel board. (vi) The rate quoted by the contractor is deemed to be inclusive of preventive and periodical maintenance for 02 years after completion of work as per the manufacturer's guide lines.
Item 3.00 contd.. (vii) Provide Automatic Rescue Device (ARD) by providing UPS of adequate capacity with SMF battery(s) having a power back up for minimum 30 minute stoop at the car a get at the nearest floor level for auto opening of door & for ejaculation of passenger & to operate car cabin fan, carlights, emergency lights, and alarm bell and intercom in the event of electric break down all as directed by GE/Engineer-in-Charge. (viii) Provn of voltage fluctuation with standing capacity to new microprocessor controller to safe guard the electric circuit and to enable smooth functioning of the light in case of voltage fluctuation in the system. (ix) Provision of safety guard equipments such as two Nos pit switches controller guarding pit pulley, guarding pit ladders, fascia plates to cover free space between car cabin and hoist way & switches. Make: ThyssenKrupp Elevator (India) / OTIS Elevator Company India Pvt. Ltd./ Schindler (India) Pvt. Ltd. / KONE Elevator India Pvt. Ltd.
ROAD / PATH / CULVERTS HARDSTANDING
Surface excavation n.exc 30cm deep and averaging 15 cm deep and getting out in hard/dense loose soil complete all as specified and as directed.
Removal of excavated material exc 250m but n.exc 500m and depositing where directed complete all as specified and as directed.
M&L for 75mm thick cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base for floors finishes complete all as specified and directed.
M&L for machine pressed precast concrete coloured interlocking paver block any shape and size confirming to IS 15658-2006, 80 mm thick, M-40 grade fixing with grey cement and pigment complete all as specified and directed.
M&L for glossy finished chequered cement concrete coloured tiles (300mm X300mm) 20-25mm thick confirming to IS -1237 (rubber moulded) in floor , set, jointed & pointed with cement slurry 15mm thick bedding layer of cement sand mortar (1:6) complete all as specified and directed.
SEWAGE DISPOSAL / AREA DRAINAGE
M&L for concrete bed 1:3:6 type C-2 to drain pipe including packing under and haunching against the sides of pipes after they are laid and tested, bore of pipe 300mm complete all as specified and as directed.
Demolition & breaking up drain pipes (salt glazed stone ware, AC or reinforced concrete) set in cement mortar, internal dia / bore of pipe 300 mm including removing debris out site MOD land complete all as specified and directed. NOTE:- Excavation / earth work shall be measured and paid separately.
M&L for Reinforced concrete pipes, class NP2, laid and jointed complete with collars bore of pipe 300mm complete all as specified and as directed.
M&L for cement concrete type B2 1:2:4 (40mm graded aggregate) as in haunching in Manhole etc complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry built in cement mortar complete all as specified and as directed.
M&L for brick work with subclass 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:4 etc complete all as specified and as directed.
M&L for plastering 15mm thick on fair faces of brickwork or concrete surfaces cement mortar 1:4 etc with using water proofing compound complete all as specified and as directed.
S&F in repair factory made SFRC manhole/drain cover (Grade M-25) heavy duty cover slab in rectangular / circular/ squared shaped of size as required 80 mm thick incl MS sheet 2 mm thick and 80 mm wide all around the cover, set in cement mortar (1:4) complete all as specified and directed.
M&L for cutting into existing manhole for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel ( 1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required of 150 mm dia of pipe complete all as specified and directed.
Supply only Integral water proofing compound complete all as specified and as directed.
M&L for PCC (1:3:6) type C-2 as in bed of drain and mass concrete complete all as specified and as directed.
M&L for PCC (1:2:4) type B0 using 12.5 mm graded aggregate as in coping etc complete including necessary formwork complete all as specified and as directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement, including forms moulds mitred/stopped ends etc complete all as specified and as directed.
Arihant Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .