Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.4 LAccepted-AOC GURDASPUR ROAD OPP WAREHOUSE PATHANKOT 145 001 PB | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹44.9 L+₹4.5 L (11.1%)Rejected-Finance KTA ROAD LAMBA LINE JUNGLIGHAT PO PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹46.3 L+₹5.9 L (14.5%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹46.5 L+₹6.1 L (15.0%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹46.5 L+₹6.1 L (15.1%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
26 Sept 2024, 6:00 pmClosed
GE HADDO PORT BLAIR
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
REPAIRS/ REPLACEMENT AND HYGINE OF LT UG CABLE AT NAVAL AREA UNDER GE HADDO, PORT BLAIR
2024_MES_672436_1
8893/E8
Open Tender
Civil Works
Item Rate
270 days
PORT BLAIR
As per tender document
9 documents required · 9 mandatory
₹500
GE HADDO
₹80,000
Yes
21 Jan 2025
5 Sept 2024
3 Oct 2024
5 Sept 2024
26 Sept 2024
19 Sept 2024
Amount
M&L for lifting of RCC slab, approximate length (2 to 4.5m) x width (1 to 2m) and upto 300mm thick and about 3.0 to 5.0 ton in weight on IN Jetty by lifiting of suitable slab with in 10 to 15m of length as per site condition by cutting /chipping the clearance, groove all around. keeping aside using a crane for laying of HT/LT cables or removing and relaying after fault rectification and replacing RCC slab at the same location after carrying out repairs including making good the surface with PCC (1:2:4) complete all as specified and directed. NOTE : (i) Two to three Nos of slab shall be taken out / removed as per site condition for laying of cables / earth strip in the cable duct of Jetty after for a span of 15 to 20 meters or as per site requirement. (ii) Cost of T&P required for the work shall be included in the quoted rate. (iii) Site will be availabile in a restricted manner and prior approval shall be obtained before commencement of work. (iv) Contractor is liabile for any damage caused to existing services or structures during the execution of work (v) Contractors are advised to visit the sites before quoting the rates.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth, for foundation of poles, stays, struts or for laying cables/pipes etc., not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. NOTE: 1. If new cable is laid as replacement of old cable in the same trench, all excavation and earth work shall be measured only once. 2. If any pipe is laid in trenches as cable protection, all excavation and earth work shall be measured either for cable or for pipe only and not for both. 3. If cable is laid in tiers and in loops, all excavation and earth work shall be measured accordingly.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each as in soils complete all as specified and as directed.
Removing excavated material (soils) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade of size 2 core x 6 sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., and connecting up with suitable size of lugs, glands and jointing material including taking out old unserviceable cable complete all as specified and as directed. NOTE:- (i) Necessary test results like continuity test, megger tests, shall be submitted to Engineer-in-Charge before the cable is laid. (ii) Necessary excavation earth work will be measured and paid separately under relevant items of this Schedule
All as per item No 5 herin before but cable of size 2 core x 10 sqmm
All as per item No 5 herin before but cable of size 4 core x 16 sqmm
All as per item No 5 herin before but cable of size 3.5 core x 25 sqmm
All as per item No 5 herin before but cable of size 3.5 core x 35 sqmm
All as per item No 5 herin before but cable of size 3.5 core x 50 sqmm
All as per item No 5 herin before but cable of size 3.5 core x 70 sqmm
All as per item No 5 herin before but cable of size 3.5 core x 95 sqmm
All as per item No 5 herin before but cable of size 3.5 core x 120 sqmm
All as per item No 5 herin before but cable of size 3.5 core x 185 sqmm
All as per item No 5 herin before but cable of size 3.5 core x 240 sqmm
All as per item No 5 herin before but cable of size 3.5 core x 300 sqmm
All as per item No 5 herin before but cable of size 3.5 core x 400 sqmm
M&L for GI earth strip of size 32 x 6mm laying in trench, fix to pole with necesary clamp and nut, bolt etc including taking out of unserviceable earth strip complete all as directed.
Taking down the corroded/ detoriated GI pipe from the trench crossings / obstructions for cable protection, supply & lay GI pipe 100mm medium grade including cuttings of existing road and making good the disturbed surfaces all as specified and directed. Make : Oswal / Jindal / TATA
Supply, connect and testing for straight though joints for 1100 volts grade of LT UG cables of size 3.5 core 25 to 50 Sqmm including taking out old joint complete all specified & directed.
All as per item No 20 herein before but for 3.5 core 70 to 95 sqmm.
All as per item No 20 herein before but for 3.5 core 120 to 150 sqmm.
All as per item No 20 herein before but for 3.5 core 185 to 240 sqmm.
All as per item No 20 herein before but for 3.5 core 300 to 400 sqmm.
Material & labour for laying of chequered plates of any thickness by cutting / making in to the shape providing necessary angular supports and handles with 6 mm dia rod as per the site condition for cable trenches of various sub-stations Fe-410-W (Gde E-250) quality-A alongwith painting of two coats of alongwith painting of two coats of synthetic enamel over a coat of redoxide all as specified and directed.
Taking down/removal of old burnt/damaged LT cable end termination after isolating supply to transformer/LT pillar box/LT panel and disconnecting burnt/faulty cable from the bunch of cable gland, M&L for new termination with suitable size of lugs duly crimped for LT, 1100 volts, 3½ core 95 Sqmm to 500 Sqmm, armoured aluminium conductor cables and connecting back with new nuts, bolts and washers of nickel chromium and applying petroleum jelly after end termination, testing and commissioning complete all as specified and as directed.
Supply and laying HDPE DWC pipe of size 120mm (OD) x 103mm (ID) along with connected accessories like couplers, bends, end caps etc. laid in trenches/floors/ducts or fixed on poles/walls for as in protection of LT/ HT cable protection complete all as specified and as directed by engineer in charge. [Make: Rex Poly Extrusion Ltd/ Tirupati Plastomatics Pvt Ltd.]
Supply and laying HDPE DWC pipe of size 77mm (OD) x 63mm (ID) along with connected accessories like couplers, bends, end caps etc. laid in trenches/floors/ducts or fixed on poles/walls for as in protection of LT/ HT cable protection complete all as specified and as directed by engineer in charge. [Make: Rex Poly Extrusion Ltd/ Tirupati Plastomatics Pvt Ltd.]
M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick,40mm bore medium grade (steel pipe) buried directly in ground (earth pit not less than 2.25m deep below GL) with top edge of the plate not less than 1.5m below normal GI, connected to galvanised earth strip 32 x 6 mm by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 connected to earthing test point all as specified or indicated including testing on completion. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 451 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
Disconnecting old unserviceable /under rated LT UG cables of size 3½ core, 50 to 185 Sqmm from its connections, taking out the cable from trenches or drawing out from the pipe and shifting the cable from existing location (power house) to different location (feeders/jetty/any other location) and re-using the same by laying in trenches / ducts or passing through pipes or fixed on walls / pole with suitable clamps/saddles and connecting up with suitable size of lugs, glands and jointing material complete all as specified and as directed. NOTE: Necessary excavation earth work will be measured and paid separately under relevant items of this Schedule
All as per item no.30 above but for size 3.5 core 185 to 500Sqmm.
Disconnecting and taking out existing old unserviceable copper bus bar of any size or shape and supply and fix new copper bus bar of suitable size and capacity to suit the existing requirement with proper bakelite highlam sheet, insulators, GI bolts, nuts and washers of required size for mounting including reconnecting the electric cables complete all as specified and as directed by Engineer in charge.
M&L for mild steel framed brackets fabricated made out of angles or tees, web and flanges heavy duty hinges for welding of cope boxes / panel doors etc., cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc., conforming to Fe-290 Gde E-165 including fabrication, fixing and painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including dismantling existing old unserviceable brackets and the like complete all as specified and as directed.
S&F heat shrinkable sleeves suitable for 150Sqmm to 500Sqmm LT UG cable, 415V grade including disconnecting LT UG cable from Transformer/LT Panel/Feeder Pillar Box/Cope boxes and re-connection after completion complete all as specified and directed.
Taking down existing LT Panel board and Supply and Fixing of outdoor LT Panel / LT Pillar Box of dimensions 1.8m x 1.4m x 0.6m size with following specifications. Fabrication Details : CPRI approved Main frame 3.15mm thick CRCA sheet, partition sheets / covers / doors of 2 mm thick CRCA sheet, gland plates 2 mm thick MS sheet (undrilled), base frame on ICMS channel with provision of incoming and outgoing cable entry at the bottom for outdoor installation, free standing floor mounted with degree of protection IP- 65 and locking arrangements. Bus bar details : Material shall be alluminum bus bar, sleeving heat shrinkable type, with bus bar sizes for phase 40mmx20mm aluminium Flat, neutral 40x10mm aluminium flat and bus bar support of epoxy type. Painting Detais : Pillar box shall be powder coated and painted with two coats of synthetic enamel spray paint over a coat of redoxide primer. Accessories for Pillar Box : 0-500V Digital voltmeter - 01 No and 0-630V Digital Ammeter - 01 No(0-500A), (Flush type) and Indication Lamps (LED) - 03 No. make: L&T /Binay /Elmeasure (a)Incomer:- 400A 4 pole , MCCB of Make:L&T or equivalent -1no. (b)Outgoings :- (i) 200A,3 pole MCCB,36kA of make: L&T, Cat No. CM98060OOO -1 nos. (ii) 125A, 3 pole MCCB of make: L&T, Cat No. CM90678OOLO -2 nos. (iii) 100A, 3 pole MCCB of make: L&T, or equivalent -3 nos. Location: At Samudrika Note: (i) All MCCBs should be of adjustable over load 80-100%, with thermal magnetic release Ics=100%Icu, suitable for any type of loads. (ii) Quoted rate is deemed to be includes cost of MCCBs, Volt meter, Ammeter, indication lamps, Change over switches and connected control wiring with 2.5Sqmm FRLS copper conductor and necessary spreader links, lugs,glands and connecting of cables complete all as specified as per site conditions and as directed by Engineer-in-Charge.
Accessories for Pillar Box : 0-500V Digital voltmeter - 01 No and 0-630V Digital Ammeter - 01 No(0-500A), (Flush type) and Indication Lamps (LED) - 03 No. make: L&T /Binay /Elmeasure (a)Incomer:- 400A 4 pole , MCCB of Make:L&T or equivalent -1no. (b)Outgoings :- (i) 200A,3 pole MCCB,36kA of make: L&T, Cat No. CM98060OOO -1 nos. (ii) 125A, 3 pole MCCB of make: L&T, Cat No. CM90678OOLO -2 nos. (iii) 100A, 3 pole MCCB of make: L&T, or equivalent -3 nos. Location: At Samudrika Note: (i) All MCCBs should be of adjustable over load 80-100%, with thermal magnetic release Ics=100%Icu, suitable for any type of loads. (ii) Quoted rate is deemed to be includes cost of MCCBs, Volt meter, Ammeter, Idiction lamps, Change over switches and connected control wiring with 2.5Sqmm FRLS copper conductor and necessary spreader links, lugs,glands and connecting of cables complete all as specified as per site conditions and as directed by Engineer-in-Charge. (iii) The unit rate quoted deemed to include for cost of breaking the existing PCC foundation, if any and making good the disturbed surfaces to match with existing surfaces. (iv) Drawings must be approved by Engineer-in-Charge before fabrication of LT Panel.
Cutting the existing road surface/PCC/ foot path (approx 50cm x 30cm) for laying of HT/LT cables including excavation of trenches, refurming filling, removal of soil in any type of soil, including making good for disturbed surfaces with PCC 1:2:4 type B1 using 20mm graded stone aggregate, use & waste of necessary form work including watering complete al as specified and directed.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping of pole including use & waste of necessary form work including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as as directed by engineer in charge.
S&F MCCB 4 Pole, 63 Amps, 25kA, 415 volts, 50 Hz adjustable over load 80-100%, with thermal magnetic release Ics=100%Icu, connecting up with necessary spreader links complete all as directed including disconnecting & taking down existing unserviceable MCCBs from LT panels / feeder pillar boxes complete all as specified and as directed by Engineer in charge. [Cat No. CM91712OOJOOG of make: L&T or equivalent in Schneider/ ABB/ Legrand]
S&F MCCB 4 Pole, 100-125 Amps, 25kA, 415 volts, 50 Hz adjustable over load 80-100%, with thermal magnetic release Ics=100%Icu, connecting up with necessary spreader links complete all as directed including disconnecting & taking down existing unserviceable MCCBs from LT panels / feeder pillar boxes complete all as specified and as directed by Engineer in charge. [Cat No. CM90642OOLO of make: L&T or equivalent in Schneider/ ABB/ Legrand]
S&F MCCB 4 Pole, 160-200 Amps, 25kA, 415 volts, 50 Hz adjustable over load 80-100%, with thermal magnetic release Ics=100%Icu, connecting up with necessary spreader links complete all as directed including disconnecting & taking down existing unserviceable MCCBs from LT panels / feeder pillar boxes complete all as specified and as directed by Engineer in charge. [Cat No. CM90642OONO of make: L&T or equivalent in Schneider/ ABB/ Legrand]
S&F MCCB 4 Pole, 200-250 Amps, 36 kA, 415 volts, 50 Hz adjustable over load 80-100%, with thermal magnetic release Ics=100%Icu, connecting up with necessary spreader links complete all as directed including disconnecting & taking down existing unserviceable MCCBs from LT panels / feeder pillar boxes complete all as specified and as directed by Engineer in charge. [Cat No. CM92109OOP1OG of make: L&T or equivalent in Schneider/ ABB/ Legrand]
M & L for fault detection in damaged HT/LT UG cable by using cable fault detector/locator vehicle mounted comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc to accuracy of 2 meter for various location inside Haddo and vijaybaugh for UG cables of any size any type upto 11 KV incl excavation & Earthwork in any type of stratra to usually inspect/repair the damaged cable when and where required all as directed by Engr-in-Charge. Note : (i) Compaint will be notified to contractor on mobile phone at any time and contractor is responsible to rectify the fault after notification. (ii) Rates included necessary earth work in any type of strata or road for opening the cable and prepare the cable ready to jointing work and making good to match with existing finishes. (iii) Cable joints and cable if required shall be measured and paid separately.
Kakolil Trade Agencies (BID ID -3115004)
M/s Kamal Electrical (BID ID -3114658)
Bismi Builders & Enterprises (BID ID -3114728)
NAVJEEVAN ENTERPRISES (BID ID -3114463)
SKV Engineering (BID ID -3114922)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .