Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC AT BUDHIJAM COLONY ORIENT COLLIERY BRAJRAJNAGAR JHARSUGUDA ODISHA 768216 | JHARSUGUDA | ODISHA | 768216 | ₹17.7 L Quoted ₹15.0 L | L1 | Accepted-AOC AOC awarded for being L1. |
| 2 | L2₹18.0 L+₹3.0 L (19.9%)Rejected-Finance AT RAMPUR COLLIERY BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | ₹18.0 L+₹3.0 L (19.9%) | L2 | Rejected-Finance Rejected for being L2. |
| 3 | L3₹18.2 L+₹3.2 L (21.4%)Rejected-Finance AT PLOT 2388 8730 239 8731 2387 5729 INFRONT OF BSNL OFFICE GANDHI CHOWK BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | ₹18.2 L+₹3.2 L (21.4%) | L3 | Rejected-Finance Rejected for being L3. |
Tender Value
₹27.2 L
EMD Value
₹34,100
Closing Date
31 May 2024, 5:00 pmClosed
Staff Officer(EnM), Orient Area
Office of the EnM Dept, GM Office, Orient Area
Day to day HT and LT overhead line work (colony LT lines , 3.3 KV ,11KV,33KV HT line) for Regional Sub Station, Kalinagar for a period of 365 days.
2024_MCL_308138_1
MCL/GM/OA/EnM/e-Ten/24-25/03 Dtd.14/05/2024
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Regional Substation, Kalinagar
AS PER NIT
4 documents required · 4 mandatory
₹34,100
26 Jul 2024
14 May 2024
1 Jun 2024
14 May 2024
31 May 2024
15 May 2024
14 May 2024 - 20 May 2024
Amount
Assistance in day to day HT & LT overhead work in summer & moonsoon season and any other emergency work as instructed by Engineer-In-Charge.(02 Electrician & 02 Electric Helper)
Testing of insulation level of 33 KV overhead lines, Insulators and Lightening arrestors as per IE rules and replacing of insulators (Pin, Post, Disc insulator), lightening arrestors if required and checking earthing continuity of running earthing and lightening arrestors once before monsoon season.
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.0 metre and upto 12.0 metre
Erection of all aluminium conductor of 7/1.96 mm to 7/3.10 mm diameter including binding etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) V shape cross arm for two 11 KV over head line conductors complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Supplying of 50 mm X 8 mm M.S. flat iron pole top bracket/ cross arm for single 11/22/33 KV over head line conductor complete with fixing clamps, bolts, nuts and washers drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/ 33 KV as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required.
Supply of 33KV Pin insulator with washer & Nuts
Supplying 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Erection of disc/ pin insulator for 11 KV/33KV over head lines as required.
Supplying and erection of stay set complete (galvanised) with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener, 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Loading and unloading of pole
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 8.0 metre and upto 10.0 metre
Erection of all aluminium conductor of 7/3.40 mm to 7/4.00 mm diameter and above including binding etc. as required.
Supplying and erection of 100 mm X 110 mm shackle insulator with G. I. Bolt, nuts and straps etc. as required .
Supplying and erection of 100 mm X 80 mm pin insulator complete with G. I. Spindle and nuts etc. as required .
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required .
Supplying and erection of stay set complete (galvanised) with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required .
Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supply of Aluminium Lugs for 50Sq.mm Cable
Supply of Aluminium Lugs for 70Sq.mm Cable
Supply of Aluminium Lugs for 95Sq.mm Cable
Supply of Aluminium Lugs for 120Sq.mm Cable
Supply of Aluminium Lugs for 150Sq.mm Cable
Supply of Aluminium Lugs for 185Sq.mm Cable
Supply of Aluminium Lugs for 240Sq.mm Cable
Supply of Aluminium Lugs for 300Sq.mm Cable
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:(3CX120Sq.mm)
Supply of Fixed Contact 11KV,400A for Gang Operated Air Break Switch
Trimming of trees and branches, removing the roots, disposal of unserviceable material before onset of monsoon season.(Beyond 30 cm girth upto and including 60 cm girth)
Uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish to a distance of 50 m outside the periphe of the area cleared cleared of different sub stations two times in a year under RSS Kalinagar, OA
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
M/s BIKASH ENTERPRISES
R.K SINGH AND SONS
Bidder Name
M/S LIGHT PALACE
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_319296.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .