Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-Finance 000 RATH TALA UKHRA UKHRA UKHRA BARDHAMAN WEST BENGAL 713363 | PASCHIM BARDHAMAN | WEST BENGAL | 713363 | ₹23.8 L | L1 | Accepted-Finance 1st lowest bidder |
| 2 | L2₹24.0 L+₹13,009.84 (0.55%)Rejected-Finance | ₹24.0 L+₹13,009.84 (0.55%) | L2 | Rejected-Finance 2nd lowest bidder |
| 3 | L3₹24.0 L+₹13,895.84 (0.58%)Rejected-Finance 10 11 UMA CHARAN BHATTACHARJEE LANE HOWRAH 711101 | HOWRAH | HOWRAH | WEST BENGAL | 711101 | ₹24.0 L+₹13,895.84 (0.58%) | L3 | Rejected-Finance 3rd lowest bidder |
| 4 | L4₹29.4 L+₹5.6 L (23.5%)Rejected-Finance NICHUPATY BOLPUR P WEST BENGAL BIRBHUM PIN 731204 | BOLPUR | BIRBHUM | WEST BENGAL | 731204 | ₹29.4 L+₹5.6 L (23.5%) | L4 | Rejected-Finance 4th lowest bidder |
| Sl No | Description | Qty | Unit | NARAYAN CHANDRA DAS L4 | MAA TARA ENTERPRISE L1 | M/S R. K. ENTERPRISE L2 | ELECTRO POWER L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | S/F Double Door Type 8 Way Vertical TPN PDB in S.S. enclosure with IP-42/43 protection (Cat no 6079 14) on wall consisting with 1 no 125 A., 4-Pole MCCB (36KA, 420096) as incomer, 8 nos. 63A. TP MCB as outgoing. and both side cable end box complete with all connection with suitable size of Cu. wire with proper socketing as per direction of E.I.C. (Make:- Legrand / Siemens / Schnider(1.6mm) | 3 | Sets | 45,500 ₹1,36,500 Lowest | 48,950.87 ₹1,46,852.61 | 48,980 ₹1,46,940 | 48,960 ₹1,46,880 |
| 2.00 | S & Fixing 415V. 125A four pole on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc as to G.S. (Make:L&T--for UPS) | 3 | Sets | 11,799 ₹35,397 Lowest | 16,975.44 ₹50,926.32 | 16,980 ₹50,940 | 16,981 ₹50,943 |
| 3.00 | S&F Double Door 8-Way TPN MCB DB (Up to 160 A) in S.S. enclosure (min 1.5mm thick) with IP-42/43 protection flushed in wall consisting with 1 No., 100A. 4-Pole Isolator as incomer & 24 nos., 16 - 32 A. SP MCB as outgoing, complete with DIN Channel, Neutral Bar, Earth Bar , both side cable end box and other accessories & connection with suitable size of Cu. wire with proper socketing incl. necsy. earthing attachment.(Make:- Legrand/ Siemens / Schnider (1.6mm)]. | 2 | Sets | 15,700 ₹31,400 Lowest | 19,984.7 ₹39,969.4 | 19,989 ₹39,978 | 19,983 ₹39,966 |
| 4.00 | S/F Double Door 2+10 Way SPN MCBDB in S.S. enclosure (min 1.5mm thick) with IP-42/43 protection flushed in wall consisting with 1 No., 63A. DP Isolator 10 nos., 6/16/32 A. SP MCB as outgoing, complete with DIN Channel, Neutral Bar, Earth Bar and other accessories & connection with suitable size of Cu. wire with proper socketing incl. necsy.earthing attachment.(Make :- Legrand / Siemens / Schnider (1.6mm)]. (for lighting and computer point) | 10 | Sets | 5,850 ₹58,500 Lowest | 7,436.49 ₹74,364.9 | 7,450 ₹74,500 | 7,445 ₹74,450 |
| 5.00 | S & Fixing of 4 way MCB SS enclosure with IP-20/30 protection including 4P 63 A, C-Curve MCB , powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment (Make:Legrand/Schnider/Siemens)--for UPS | 3 | Sets | 5,200 ₹15,600 | 4,327.47 ₹12,982.41 Lowest | 4,350 ₹13,050 | 4,335 ₹13,005 |
| 6.00S & Drawing following sizes PVC insulated FRLSH Cu wire in suitable sizes of 25mm polythene / PVC rigid conduit pipe (Precision/Polycab make, HMS/MMS Type) recessed in/on wall as follows incl. making connections as per direction of EIC as to G.S. (Make :- Havells/Polycab/KEI/Gloster) | |||||||
| 6.01 | (a) 4x16 & 2x10 mm² copper wire. | 250 | Mtrs. | 1,964 ₹4,91,000 Lowest | 2,147.14 ₹5,36,785 | 2,150 ₹5,37,500 | 2,146 ₹5,36,500 |
| 6.02 | (b) 2 x 6 & 1 x 4 mm² copper wire | 250 | Mtrs. | 448 ₹1,12,000 | 374.22 ₹93,555 Lowest | 380 ₹95,000 | 375 ₹93,750 |
| 7.00Finishing the end of following sizes copper wire end / PVC cable/Al. with dowells solderless socket (Make:dowells) by crimping method as per GS as follows :- | |||||||
| 7.01 | (a) 4x16 & 2x10 mm² copper wire. | 30 | Sets | 100 ₹3,000 Lowest | 179.14 ₹5,374.2 | 180 ₹5,400 | 180 ₹5,400 |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
22 Aug 2026, 12:00 pmClosed
Exe.Engr._I, KSHED, P.W.Dte.
75 D H Road Kidderpore Kol_23
IPGMER-SSKM Hosp- Providing FDS, Fire Damper System at Fire Control Room and Emerg. and Escape lighting as per Revised Fire safety Recom. of Trauma Care Centre (G X), New OPD Bldg (B G Viii), Sports Medicine(G III) and Building (G VIII)-E.I. work
2026_WBPWD_5016706_1
WBPWD/EE-I/KSHED/Q26/26-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
90 days
SSKM Hospital
Please refer Tender documents.
5 documents required · 5 mandatory
₹48,000
O/o EE, KSHED, P.W.Dte.
10 Sept 2026
13 Jul 2026
25 Aug 2026
13 Jul 2026
22 Aug 2026
21 Jul 2026
20 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S/F Double Door Type 8 Way Vertical TPN PDB in S.S. enclosure with IP-42/43 protection (Cat no 6079 14) on wall consisting with 1 no 125 A., 4-Pole MCCB (36KA, 420096) as incomer, 8 nos. 63A. TP MCB as outgoing. and both side cable end box complete with all connection with suitable size of Cu. wire with proper socketing as per direction of E.I.C. (Make:- Legrand / Siemens / Schnider(1.6mm) | 3 | Sets | - | - |
| 2 | S & Fixing 415V. 125A four pole on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc as to G.S. (Make:L&T--for UPS) | 3 | Sets | - | - |
| 3 | S&F Double Door 8-Way TPN MCB DB (Up to 160 A) in S.S. enclosure (min 1.5mm thick) with IP-42/43 protection flushed in wall consisting with 1 No., 100A. 4-Pole Isolator as incomer & 24 nos., 16 - 32 A. SP MCB as outgoing, complete with DIN Channel, Neutral Bar, Earth Bar , both side cable end box and other accessories & connection with suitable size of Cu. wire with proper socketing incl. necsy. earthing attachment.(Make:- Legrand/ Siemens / Schnider (1.6mm)]. | 2 | Sets | - | - |
| 4 | S/F Double Door 2+10 Way SPN MCBDB in S.S. enclosure (min 1.5mm thick) with IP-42/43 protection flushed in wall consisting with 1 No., 63A. DP Isolator 10 nos., 6/16/32 A. SP MCB as outgoing, complete with DIN Channel, Neutral Bar, Earth Bar and other accessories & connection with suitable size of Cu. wire with proper socketing incl. necsy.earthing attachment.(Make :- Legrand / Siemens / Schnider (1.6mm)]. (for lighting and computer point) | 10 | Sets | - | - |
| 5 | S & Fixing of 4 way MCB SS enclosure with IP-20/30 protection including 4P 63 A, C-Curve MCB , powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment (Make:Legrand/Schnider/Siemens)--for UPS | 3 | Sets | - | - |
| 6S & Drawing following sizes PVC insulated FRLSH Cu wire in suitable sizes of 25mm polythene / PVC rigid conduit pipe (Precision/Polycab make, HMS/MMS Type) recessed in/on wall as follows incl. making connections as per direction of EIC as to G.S. (Make :- Havells/Polycab/KEI/Gloster) | |||||
| 6.01 | (a) 4x16 & 2x10 mm² copper wire. | 250 | Mtrs. | - | - |
| 6.02 | (b) 2 x 6 & 1 x 4 mm² copper wire | 250 | Mtrs. | - | - |
| 7Finishing the end of following sizes copper wire end / PVC cable/Al. with dowells solderless socket (Make:dowells) by crimping method as per GS as follows :- | |||||
| 7.01 | (a) 4x16 & 2x10 mm² copper wire. | 30 | Sets | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.72 MB
TenderForm.pdf
Tender Documents • 0.69 MB
BOQ_5086399.xls
BOQ • 0.85 MB
corrigendum_2.pdf
PDF • 0.51 MB
corrigendum_1.pdf
PDF • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .