| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-Finance | L1 | Accepted-Finance Being lowest quoted rates | |
| 2 | L2₹9.9 L+₹1.5 L (17.8%)Rejected-Finance JAISALMER | BARMER | RAJASTHAN | 344001 | L2 | Rejected-Finance Higher quoted amount than L1 | |
| 3 | L3₹11.3 L+₹2.9 L (34.6%)Rejected-Finance | L3 | Rejected-Finance Higher quoted amount than L1 |
| Sl No | Description | Qty | Unit | M/s Shri Inder Construction Company L2 | M/s Rashid Mohammed L1 | M/S R.K. Builders & Developer L3 |
|---|---|---|---|---|---|---|
| 1.00 | Demolition of PCC in Ground Floor and paving n exc 15 cm (below or above ground level) | 4.25 | Cum | 300 ₹1,275 | 200 ₹850 Lowest | 200 ₹850 Lowest |
| 2.00 | M&L for PCC type D2 1:4:8 using 40mm graded stone aggregate, 75 mm thick as in sub base for floors, complete all as specified and directed. | 30 | Sqm | 350 ₹10,500 | 160 ₹4,800 Lowest | 300 ₹9,000 |
| 3.00 | M&L for 50 mm thick PCC 1:3:6 type C1 (using 20 mm graded crushed stone aggregates) as in plinth protection finished even and fair w/o using extra cement | 40 | sqm | 250 ₹10,000 Lowest | 300 ₹12,000 | 300 ₹12,000 |
| 4.00 | Complete removal of existing water proofing treatment incl bedding if any n exc. 50mm thick etc. on any type of roof, cleaning with wire brushers etc. and removal of debris out side MD land complete all as specified and directed. | 255 | Sqm | 40 ₹10,200 | 30 ₹7,650 Lowest | 50 ₹12,750 |
| 5.00 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate for levelling course for consolidated thickness shall be varied from 25 to 55 mm as per the requirements all as directed by Engr-in-Charge. | 255 | Sqm | 250 ₹63,750 Lowest | 250 ₹63,750 Lowest | 300 ₹76,500 |
| 6.00 | M&L for 10mm thick screed plaster on roof for laying in CM 1:4 waterproofing treatment, with using WPC (WPC will be measured and paid separately as supply only) | 255 | Sqm | 230 ₹58,650 | 150 ₹38,250 Lowest | 300 ₹76,500 |
| 7.00 | Supply only integral Waterproofing compound. | 34.53 | Kg | 250 ₹8,631.75 | 150 ₹5,179.05 Lowest | 160 ₹5,524.32 |
| 8.00 | M&L for water proofing treatment with 3 mm thick APP (Actatic Poly Propylene) modified membrane reinforced with non woven polyester mat of weight 150 gms/sqm as centre core & without multiple layers of polyethylene applied by thermo fusion using LPG torch on the bottom portion of the membrane after applying a coat of bituminous primer @ 0.3 kg/sqm over roof (an overlap of 100 mm & 150 mm shall be provided on sides & end respectively )including a coat of bitumen grade 85/25 @ 1.20 Kg/Sqm and applying one coat of aluminium paint @ 100ml/sqm on top of APP membrane to get uniform finish complete all as per specified and directed. | 255 | Sqm | 540 ₹1,37,700 Lowest | 550 ₹1,40,250 | 550 ₹1,40,250 |
| 9.00 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar. Note : Work will be in patches or in bulk | 3 | Xsqm | 100 ₹300 Lowest | 100 ₹300 Lowest | 200 ₹600 |
| 10.00 | M & L for Sand stone 5cm thick slabs in shelves, cills, landings, cover stones, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4. including pointing in white cement (1:2) using marble dust with admixture of pigment to match complete all as specified and directed by Enginer in charge. | 30 | Sqm | 1,350 ₹40,500 | 1,300 ₹39,000 Lowest | 1,700 ₹51,000 |
Tender Value
₹9.9 L
EMD Value
₹19,800
Closing Date
16 May 2026, 6:00 pmClosed
AGE I POKARAN
MILITARY ENGINEER SERVICES ASST GARRISON ENGINEER I POKARAN MILITARY STATION POKARAN-345021
REPAIR OR REHABITATION OF RCC STRUCTURES, ROOF TREATMENT, REPAIR TO RCC FACIAS, CGI OR PPGI SHEETS UNDER AGE I POKARAN
2026_MES_760165_1
8360/E8
Open Tender
Civil Works
Item Rate
POKARAN
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE I POKARAN
₹19,800
Yes
21 May 2026
13 Apr 2026
19 May 2026
13 Apr 2026
16 May 2026
27 Apr 2026
14 Apr 2026 - 20 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Demolition of PCC in Ground Floor and paving n exc 15 cm (below or above ground level) | - | Cum | - | - |
| 2 | M&L for PCC type D2 1:4:8 using 40mm graded stone aggregate, 75 mm thick as in sub base for floors, complete all as specified and directed. | - | Sqm | - | - |
| 3 | M&L for 50 mm thick PCC 1:3:6 type C1 (using 20 mm graded crushed stone aggregates) as in plinth protection finished even and fair w/o using extra cement | - | sqm | - | - |
| 4 | Complete removal of existing water proofing treatment incl bedding if any n exc. 50mm thick etc. on any type of roof, cleaning with wire brushers etc. and removal of debris out side MD land complete all as specified and directed. | - | Sqm | - | - |
| 5 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate for levelling course for consolidated thickness shall be varied from 25 to 55 mm as per the requirements all as directed by Engr-in-Charge. | - | Sqm | - | - |
| 6 | M&L for 10mm thick screed plaster on roof for laying in CM 1:4 waterproofing treatment, with using WPC (WPC will be measured and paid separately as supply only) | - | Sqm | - | - |
| 7 | Supply only integral Waterproofing compound. | - | Kg | - | - |
| 8 | M&L for water proofing treatment with 3 mm thick APP (Actatic Poly Propylene) modified membrane reinforced with non woven polyester mat of weight 150 gms/sqm as centre core & without multiple layers of polyethylene applied by thermo fusion using LPG torch on the bottom portion of the membrane after applying a coat of bituminous primer @ 0.3 kg/sqm over roof (an overlap of 100 mm & 150 mm shall be provided on sides & end respectively )including a coat of bitumen grade 85/25 @ 1.20 Kg/Sqm and applying one coat of aluminium paint @ 100ml/sqm on top of APP membrane to get uniform finish complete all as per specified and directed. | - | Sqm | - | - |
| 9 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar. Note : Work will be in patches or in bulk | - | Xsqm | - | - |
| 10 | M & L for Sand stone 5cm thick slabs in shelves, cills, landings, cover stones, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4. including pointing in white cement (1:2) using marble dust with admixture of pigment to match complete all as specified and directed by Enginer in charge. | - | Sqm | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.48 MB
tenderll.pdf
Tender Documents • 0.64 MB
tenderlll.pdf
Tender Documents • 0.70 MB
credit.pdf
Tender Documents • 0.27 MB
AppendxC.pdf
Tender Documents • 0.76 MB
tenderl.pdf
Tender Documents • 0.68 MB
BOQ_851458.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .