Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹25.2 L+₹26,935.62 (1.08%)Rejected-Finance KALIBARI ROAD M S PAUL ENTERPRISE KALIBARI ROAD LUMDING KAMRUP METRO ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | L2 | Rejected-Finance NOT THE LOWEST BIDDER | |
| 3 | L3₹25.4 L+₹43,453.72 (1.74%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST BIDDER | |
| 4 | L4₹25.7 L+₹68,968.09 (2.76%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST BIDDER | |
| 5 | L5₹25.8 L+₹86,655.89 (3.47%)Rejected-Finance GANDHI PARK ROAD TINSUKIA ASSAM PIN 786125 | TINSUKIA | ASSAM | 786125 | L5 | Rejected-Finance NOT THE LOWEST BIDDER |
Tender Value
₹23.5 L
EMD Value
₹47,000
Closing Date
1 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE DINJAN
COMMANDER WORKS ENGINEER DINJAN
REPAIR MAINT OF EXTERNAL WATER SUPPLY AND CONNECTED ALLIED SERVICES AT FSD LAIPULI GANESHBARI CHABUA NCC COMPLEX AND HATIALI AND REPAIR MAINT OF VARIOUS EQUIPMENT OF EM INSTALLATION UNDER GE DINJAN
2024_MES_672922_1
84362/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE DINJAN
AS PER TENDER DETAILS
8 documents required · 8 mandatory
₹500
GE DINJAN
₹47,000
Yes
26 Nov 2024
7 Sept 2024
3 Oct 2024
7 Sept 2024
1 Oct 2024
23 Sept 2024
Amount
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for taking out laying of cables, poles, Pipe line etc and gettting out in soft/loose soil all as specified and as directed
M&L for horizantal boring/drilling hole mannual under the road in soft/loose soil without cutting/disturbing the existing road and inserting GI pipe 80/50/40/32mm bore for drawing the cables complete all as directed and specified. (Note: (i) Cost of acessories required for making hole/bore deemed to be included in the quoted rate. (ii) GI pipe has been measured and paid separately)
Returning, filling in, including spreading, levelling, watering and well ramming in layers n exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing and excavated materials n. exc 50 mtr and depositing where directed at a level noexc 1.5 mtr above the starting point in soil, complete all as specified and directed
Taking up or down of 15 mm bore steel tubing and connections and keeping serviceable pipes in safe custady or for reuse in the work after and including cleaning as directed the following :- (Note Excavation and earth work shall be measured and paid separately under respective items of this schedule)
All as item no 4 above but of size 20mm bore
All as item no 4 above but of size 25mm bore
All as item no 4 above but of size 40mm bore
All as item no 4 above but of size 50mm bore
M&L steel water tubing of size 20mm bore galvanised, medium grade with all fittings, laid in trenches or under road etc complete all as specified and directed
All as item no 11 above but of size 25mm bore
All as item no 11 above but of size 40mm bore
All as item no 11 above but of size 50mm bore
M&L steel water tubing of size 15mm bore galvanised, medium grade with all fittings fix to walls and ceilings or laid in floor etc complete all as specified and directed
All as item no 17 above but of size 20mm bore
All as item no 17 above but of size 25mm bore
Material and labour for Gland packing of Monoblock pumps of any size and specification and making the monoblock pump leak proof and cleaning the pump with clear cloth and making it serviceable complete all as specified and directed.
Supply & Fix in repair of Direct Online Starter for 5 HP Motor with over load relay protection complete all as directed.Make :Havells Cat No IHPDOLLA/L&T or equivallent.
Supply and fix in repair MCB,TP, 415 Volt, 'C' curve breaking capacity 10 KA, 32 Amps. Make : L&T or equivalent as approved by GE.
Taking up or down old/unserviceable cast iron sluice valve of size 150mm/100mm/80mm bore form valve pit chamber and its connection as directed
S&F 80mm bore cast iron sluice valve both end flanged, class PN 1.6 conforming to IS - 14846 with iron wheel head and stainless steel spindle including necessary jointion materials like nuts, bolt, washer, rubber fibre board gasket complete as specified
All as per item above but sluice valve of 100 mm bore
Taking down old unserviceable gunmetal gate valves any size as directed by Engrs-in-Charge.
S&F 15mm bore, gun metal gate valve, with iron wheel head screwed both ends for iron pipe as specified.
All as per item No 13 above but 20 mm bore
All as per item No 13 above but 25 mm bore
S&F Single phase preventer to existing Motor Starter (Make Minilec Cat No VSP D2/Havell's or equivalent model as approved
M&L plain cement concrete 1:2:4 type B-2 (using 40mm graded stone aggregate) as in foundation, platform, etc including necessary formwork complete as specified and directed.
M&L for Cleaning of valve pit chamber with sluice valve, pipes etc, 80mm to 100mm dia including replacement of existing wornout/defective gland packing, nut, bolt & washer, etc with new one to make the sluice valve perfectly leak proof including marking of flow direction of inlet & outlet pipe line with necessary colour coding with one coat of synthetic enamel paint after preparation of old steel surfaces valve pit cover complete all as required and as directed
M&L for filling gland packing to control water leakage in sluice valve and centrifugal/monoblock pump sets of any capacity any type as and when required and all as specified and as directed
Supply only gland packing 8/10 mm Make CHAMPION or equivalent make as approved by E-in-C complete all as directed .
Material and labours for one coat of black bituminous paint drinking water grade to inner surface of steel water tanks over 10cm width of girth including preparation of old surfaces of pressed steel plate surfaces complete all as specified and directed.
Dismanting existing pressed steel plate of size 1.22m x 1.22m x 6mm thick including taking out jointing bolts, nuts, washers, etc from upto 10000 gallons over head pressed steel water tank installed at 12 to 15 m high staging for repair, cleaning internal and external surface in full, replacement of unserviceable plates, etc and removing unservicable plates from site and keeping serviceable plates, bolts & nuts in safe custody for reuse in the work all comlpete as required and directed. (Note : Cost of temporary staging/working platfrom as required for the above operation is deemed to be included in the unit rate quoted by the bidder.)
Dismanting old unserviceable/wormout one and S&F bracing, supports, cleats, clamp, etc as per existing size/section and fabricated the stuructural steel such as angles, flat, channel, etc as required of pressed steel water tank & staging at 12 to 15 m hight including cutting, drilling holes, welding as necessary to suit the site requirement and including two coats of lead free black bituminous paint suitable for drinking water internally and two coats of aluminium paint over a coat of red oxide, zinc chrome primer to exposed surfaces of steel section after preparation of surfaces complete as directed.
S&F factory made pressed steel plate of size 1.22m x 1.22m x 6mm thick placed on existing position at 12m to 15m high staging of over head water tank including necessary jointing/connecting materials such as lead wool, rubber gasket, bituminous compound with & includingg providing new mild steel bolts, nuts, washers, etc as required at site to make the joints perfectly leak proof all as per manufacturer's insturctions and including painting with two coats lead free black bituminous paints suitable for drinking water internally and two coats of aluminium paint over a coat of red oxide, zinc chrome primer to externally after preparation of steel surfaces complete and as directed. (Make : Buildsworth or as per existing/equivlant make as approved by GE)
Fixing only serviceable pressed steel plate after necessary repair, adjustment, cleaning, washing etc and connecting with new jointing materials such as lead wool, rubber gasket, bituminous compound etc as required to make the joints perfectly leaf proof and testing for water tightness of the tank complete as directed the Engr-in-Charge. (Note : (a) Old serviceable bolts & nuts obtained from item No 89 above shall be reused after cleaning. (b) New bolts, nuts & washers wherever required as a replacement of old one as directed by the Engr-in-Charge shall be measured and paid separately as "Supply only" under relevant item)
Supply only machine made bolts, nuts and washers made with hexagonal or square head at one end screwed the other end or both ends to be fitted with washers and hexagonal or square nut, (dia of bolt 5 to 10mm and length n.exc 5cm) as directed.
Dismanting existing wornout water level indicator from PS over head water tank at 12/15m high and provision of new water level indicator made out of 3mm thick MS plate of size 15x400cm long comprising of steel rope 4mm dia, MS pulley clamps, all as per existing arrangments including 30 cm dia PVC floats, weight,etc including marking with black/white paint and painting with luninous paint showing capacity ranging from 1000 gallons to 10000 gallons all complete as required to suit the site requrement and as directed by the Engr-in-Charge .
M&L for cleaning external steel surface of existing PS OH tank installed at height of 40' to 50'of by complete removal of old paints/rust by applying detergent and scrapping/wire brushing/sand papering and washing with clear water and painting of external surface of PS OH tank complete with two coats of aluminium paint over one coat of red oxide primer including painting of structure, sluice valve and connected all pipe lines from tank to borewell as per colour coding as specified and directed by Engr-in-charge. (Note : Cost of Temporary structure/truss for painting is included in the unit rate quoted).
M&L for Servicing of Long Travel 4 Nos Motor alongwith 4 Nos Gear Box complete dismantling, overhauling, gear oil change and fillup complete all as specified and as directed by the Engr-in-charge
M&L for Servicing of Cross Travel motor & gear box assembly by greasing & gear oil chane and fillup complete all as specified and as directed by the Engr-in-charge
M&L for Hoist motor, gear box greasing & oil change and fillup complete all as specified and as directed by the Engr-in-charge
M&L for servicing of break assembly and replacement of Leather of LT brake complete including of oil filling all as specified and as directed by the Engr-in-charge
M&L for sevicing, tightness,cleaning of Pannel Board 4 Nos Drive all contractor all relay checking complete all as specified and as directed by the Engr-in-charge
M&L for Cross travel motor rewinding 3 phase, 5 HP DC convert 110 V make-bharat bijlee 2 Nos bearing chane complete all as specified and as directed by the Engr-in-charge
M&L for rechecking, callibration and minor repair to pendent push button assembly complete all as specified and as directed by the Engr-in-charge.
M&L for Timer Off relay complete all as specified and as directed by the Engr-in-charge
M&L for Contractor 9 Amps. Cap set of 4 Nos complete all as specified and as directed by the Engr-in-charge(- Make-Simens.)
M&L for MCB Single pole 16 Amps cap complete all as specified and as directed by the Engr-in-charge.
Periodical maintenance of of Mechanical laundry complete in all respect complete all as specified and as directed. Items Covered for preventive and breakdown maintenance are : (i) Industrial Washer extractor of 01 Nos (ii) Industrial Dry Cleaning Machine of 02 No (iii) Hydro Extractor of 02 No Note :- (i) Quoted rate is Exclusive of the cost of the spares used and spares will be measured separately (ii) Quoetd rate is inclusive of T&P and service Engineer.
Supply only V belt of Cat No :AX60LP039 B-124 for Industrial washer extrator model AXS 60 Make : Stefab
Supply only 3way Water Solenoid Valve for Industrial washer extrator model AXS 60 complete all as specified and as directed.
Supply only Door gasket for Industrial washer extrator model AXS 60 complete all as specified and as directed.
Supply only bearing for electric motor for Industrial washer extrator model AXS 60 complete all as specified and as directed.
Supply only Limit Switch for drain-Straight for Industrial washer extrator model AXS 60 complete all as specified and as directed.
M& L for servcing of pump Motor sets 5.0 HP capacity the pump sets by repalcing the worn out bushes, gland rope, gland bolts & nuts, etc including testing and commissioning complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of driving V belt of size “B-89” for mechnical loundry including taking out existing unserviceable one complete all as specified and directed.
Supply and fixing of driving V belt of size “B-126” for mechnical loundry including taking out existing unserviceable one complete all as specified and directed.
Supply and fixing of driving V belt of size “C-97” for mechnical loundry including taking out existing unserviceable one complete all as specified and directed.
Supply and fixing of driving V belt of size “126” for mechnical loundry including taking out existing unserviceable one complete all as specified and directed.
Supply only steam iron heater coil for mechnical loundry including taking out existing unserviceable one complete all as specified and directed.
Supply only micro switch for mechnical loundry including taking out existing unserviceable one complete all as specified and directed.
Supply only slicon pipe for mechnical loundry including taking out existing unserviceable one complete all as specified and directed.
Supply and fixing in repair 230 Volt, single phase, 3 KW strip heater complete all as specified and directed.
Supply and fixing in repair 230 Volt, single phase, 9 KW round type heater complete all as specified and directed.
Supply and fixing in repair 230 Volt, single phase, 3 KW round type heater complete all as specified and directed.
Supply and fix in repair of double function type bearing for washer extractor or drying tumbler of capacity upto 60 KG including all fitting and fixture washer nut, bolts complete all as specified and as directed.
Supply and fix in repair of Vibrator bush as per existing sample complete all as specified and as directed.
M&L for Servicing of Fully electronic lorry weight bridge of capacity 40 MT by providing expert skilled person to check & calibration for lorry bridge using 3 Ton CI test weights incl transportion, repair and test to make the equipment in fully funtional and carry preventive mentance for unintruppted functioning of equipment all as specified and as directed.
Supply only display unit with RS-232 Facility for lorry weight bridge of capacity 40 MT complete all as specified and as directed by Engr-in-charge.
Supply only load cell cup and ball type lorry weight bridge of capacity 40 MT complete all as specified and as directed by Engr-in-charge.
Repair and maintenace of digital microprocesser/ computer system with printing module including refilling/replacing of printer cartridge complete all as specified and as directed by Engr-in-charge.
updating the software(Licence) of computer for lorry weigh bridge complete all as specified and as directed by Engr-in-charge.
Opening the 3 HP induction motor of Air compressor, taking down/out the burnt winding wire and cleaning the slots including rewinding the induction motor with super enamelled copper winding wire of existing gauge ,weight etc. and unserviceable spare parts including machining work and re-assembling the same in original position including all other insulating material complete all as specified and as directed.
Supply and fixing in repair of Air presure meter in air compresssor complete all as specified and directed
Supply and fixing in repair of V belt in air compresssor complete all as specified and directed
Supply and fixing in repair of Air pessuer switch in air compresssor complete all as specified and directed
Supply and fixing in repair of Comprehesive maint of air compressor complete all as specified and directed
Supply and fixing in repair of Air presure copper line in air compresssor complete all as specified and directed
Supply and fixing in repair of Air filter in air compresssor complete all as specified and directed
Supply and fixing in repair of MN 16 DOL starter type suitable upto 5 HP complete all as specified and directed
M&L for Servicing of 5 KVA ONLINE UPS providing expert skilled person to check, repair and test to make the equipment in fully funtional and carry preventive mentance for unintruppted functioning of equipment all as specified and as directed.
Supply and fixing in repair of 12 V 12 AH battery for UPS complete all as specified and directed
Providing of service for preventive and Comprehensive maintenance as per original equipment manufacture's (OEM'S) reccommendations for 10 x 16 HP VRF Air Conditioning units and associated indoor units by cleaning of airfilters,cleaning of all air control equipment for optimum cooling in every room, checking and rectification of minor control wiring, checking of all safety measures, topping of required refrigerant gas and compressor oil as required, balancing of blower etc and including repair/replacement of unserviceable spare parts as and when required i.e compressor of the VRF unit, micro processor control unit, indoor blower motor, outdoor fan motor, fan motor blade, condensor coils, airfilters, dampers, liquid line gas filter, charging valve, contractors, blower motor bearing, required size V-belts, leak test by nitrogen gas and charging the refrigerant as required at site, including test run for 24 hrs to achieve satisfactory service and designed condition test results, in presence of Engineer-in-Charge complete all as specified and directed. (a) Monthly checking and serviicing of the air - conditioning plant / units. (b) Attending to the plant when called upon by you. (c) Cleaning of air-filters once in every months (d) Taking a set of readings for parameters for assessing the healthiness of AC systems / circuits. (e) Checking/ clenaing the drain line of the units if found necessary (f) Cleaning the evaporator and condenser coils maximum twice in a year if condiered necessary. (g) Repairing/ overhauling the components of the equipment at site/ in our service station, including replacement of worn out parts when found necessary. (h) Replenishing regrigerant requried as a result of al eak in the system arising out of fair wear and tear. (j) Repair/ replacement of Microporcessor controls (k) Repacement of Sensors, pressure switches, PCB of indoor / outdoor unit if found defective (l) Lubricatingthe bearings of mototr, and fans when found necessary. (l) Checking the refrigerant system. (m) Checking motors and starters,checking the operation of controls. (n) Rewinding/ replacement of outdoor motor if found defective (o) Replacement of compressor if found defective from our loan stock .
Providing of service for Preventive and comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations of floor mounted Central air cooled AC plant of capacity 3x28TR, by cleaning of airfilters, cleaning of all dampers for optimum cooling in every room, duct inspection and cleaning from inside, checking and rectification of control wiring,greasing of blower motor, checking of all safety measures, topping of required refrigerant gas and compressor oil it retained as required, balancing of blower etc and including repair/replacement of unserviceable spare parts as and when required i.e compressor of the package unit, micro processor control unit, indoor blower motor, outdoor fan motor, fan motor blade, condensor coils, airfilters, dampers, liquid line gas filter, charging valve, contractors, blower motor bearing, required size V-belts, leak test by nitrogen gas and charging the refrigerant as required at site, including test run for 24 hrs to achieve satisfactory service and designed condition test results,in presence of Engineer-in-Charge, complete all as specified and directed. [Central AC plant of capacity 3x28 TR,Make- M/s Batliboy Ltd (installed at 162 MH)
Providing of service for Preventive and comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations for floor mounted Package type water cooled AC plant of capacity 3 x5 TR by cleaning of airfilters,cleaning of all air control equipment for optimum cooling in every room, duct inspection and cleaning from inside, checking and rectification of minor control wiring, greasing of blower motor,checking of all safety measures, topping of required refrigerant gas and compressor oil as required, balancing of blower etc and including repair/replacement of unserviceable spare parts as and when required i.e compressor of the package unit, micro processor control unit, indoor blower motor, outdoor fan motor, fan motor blade, condensor coils, airfilters, dampers, liquid line gas filter, charging valve, contractors, blower motor bearing, required size V-belts, leak test by nitrogen gas and charging the refrigerant as required at site, including test run for 24 hrs to achieve satisfactory service and designed condition test results, in presence of Engineer-in-Charge complete all as specified and directed.[Package type air cooled AC plant of capacity 3 x 5 TR, Make - M/s Batliboy Ltd installed at 162 MH].
Transportation of repairable refrigerator of capacity 165 litres to 350 litres from MES store yard to contractor's work shop and return the same to MES Store yard in serviceable condition after duly repaired complete all as specified and as directed. Note : Repair work shall be carried out under respective items of this BOQ and accordingly measured and paid separately.
All as per serial item No. 89 above but water cooler of capacity 40 litres to 120 litres.
All as per serial item No. 89 above but split type air conditioner of capacity upto 2 TR.
All as per serial item No.89 above but window type air conditioner of capacity 1 TR to 2 TR.
All as per serial item No. 89 above but deep freezer upto 320 ltrs capacity.
M&L for flushing, welding, vaccuming and gas charging to refrigerator of capacity 286 litres to 350 litres including refrigerant gas of suitable quantity complete all as specified and as directed. Note : Cost of gas for refrigirator : R-134A included in the quoted rate.
M&L for flushing, welding, vaccuming and gas charging to Refrigerator of capacity 165 litres to 250 litres including refrigerant gas of suitable quantity complete all as specified and as directed. Note : Cost of gas for refrigirator : R-134A included in the quoted rate.
M&L for flushing, welding, vaccuming and gas charging to water cooler of capacity 60 litres to 120 litres including refrigerant gas of suitable quantity complete all as specified and as directed. Note : Cost of Gas for Water Coolers : R-134A is included in the unit quoted rate.
M&L for flushing, welding, vaccuming and gas charging to water cooler of capacity 40 litres including refrigerant gas of suitable quantity complete all as specified and as directed. Note : Cost of gas for water coolers : R-134A included in the unit quoted rate.
M&L for flushing, welding, vaccuming and gas charging to window type air conditioner of capacity 2 TR including refrigerant gas of suitable quantity complete all as specified and as directed. Note : Cost of gas for AC's : R-22 is included in the unit quoted rate.
M&L for flushing, welding, vaccuming and gas charging to window type air conditioner of capacity 1.5 TR including refrigerant gas of suitable quantity complete all as specified and as directed. Note : Cost of gas for AC's : R-22 is included in the unit quoted rate.
M&L for flushing, welding, vaccuming and gas charging to deep freezer of capacity 320 Ltrs including refrigerant gas of suitable quantity complete all as specified and as directed. Note : Cost of gas R-134A included in the unit quoted rate.
M&L for flushing, welding, vaccuming and gas charging to split type air conditioner of capacity 1.5TR including refrigerant gas of suitable quantity complete all as specified and as directed. Note : Cost of gas for AC's : R-22 is included in the unit quoted rate.
M&L for flushing, welding, vaccuming and gas charging to split type air conditioner of capacity 2TR including refrigerant gas of suitable quantity complete all as specified and as directed. Note : Cost of gas for AC's : R-22 is included in the unit quoted rate.
S&F in repairs door rubber gasket with magnetic strip for refrigerator of capacity upto 350 litres of any make complete all as specified and as directed.
S&F in repairs PVC freezer chest doors, heavy duty, suitable for Godrej/Kelvinator/ Whirlpool make of Capacity upto 350 litres complete all as specified and as directed.
S&F in repairs auto defrost thermostat switch for refrigerator of capacity upto 350 litres complete all as specified and as directed.
S&F in repairs PVC heavy duty Ice tray for refrigerator of any make and capacity complete all as specified and as directed.
S&F in repairs open type relay for refrigerator of any make of capacity upto 350 litres complete all as specified and as directed.
S&F in repairs frost free blower motor of refrigerator complete all as specified and as directed.
S&F in repairs bi-metal relay for refrigerator complete all as specified and as directed.
S&F for timer for frost -free refrigerator complete all as specified and as directed.
S&F in repairs heating element for frost -free refrigerator complete all as specified and as directed.
S&F in repairs overload protector for refrigerator of any make and capacity upto 350 litres complete all as specified and as directed.
S&F in repairs copper conductor cables, 3 core, 4 Sqmm, 1100 volts grade FRLHS suitable for refrigerator/W.cooler complete all as specified and as directed.
S&F in repairs copper conductor cables, 3 core, 6 Sqmm, 1100 volts FRLHS grade suitable for AC complete all as specified and as directed.
Attending of complaints of only leakage of R-22 for split type AC and rectification on site and charging of refrigerant in system complete all as specified and as directed.
S&F in repairs drier filter 1/4" flare nipple for Deep Freeze complete all as specified and as directed.
S&F in repairs groomet rubber mounting for refrigerator, water cooler, air conditioner of any make and capacity complete all as specified and as directed.
S&F in repairs evaporator cooling coil for refrigerator of capacity 165 litres to 350 litres of any make complete all as specified and as directed.
S&F in repairs relay open type suitable for water cooler of any model and capacity complete all as specified and as directed.
S&F in repairs thermostat long tail of suitable capacity for water cooler complete all as specified and as directed. Make : Model No. 2064 of Indofoss.
S&F in repairs rubber lining for top cover suitable for water cooler complete all as specified and as directed.
S&F in repairs 15 mm bore, push cock, copper alloy, chromium plated, suitable for water cooler of any make complete all as specified and as directed.
Taking down carefully unserviceable indoor electronic type PCB at existing location repair and refixing split type AC of capacity 1.5 to 2.0 ton complete all as specified and as directed.
S&F in repairs stainless steel water tray basin for water cooler of any type complete all as specified and as directed.
S&F in repairs overload protector for water cooler of any capacity complete all as specified and as directed.
S&F in repairs capillary tube (copper) n.exc 20 ft long suitable for water cooler of any type complete all as specified and as directed.
S&F in repairs 20 mm bore, PVC high density polyethylene drain pipe complete with elbow and clamp suitable for referigerator/water cooler of any type complete all as specified and as directed.
S&F in repairs fan motor, 1/16 HP suitable for water cooler complete all as specified and as directed.
S&F in repairs condenser fan for water cooler of any make and capacity complete all as specified and as directed.
S&F in repairs sealed compressor suitable for refrigerator of capacity 286 litres to 350 litres complete all as specified and as directed.
S&F in repair sealed compressor suitable for referigerator of capacity 165 litres to 250 litres complete all as specified and as directed.
S&F in repair sealed compressor suitable for water cooler of capacity 60 litres to 120 litres complete all as specified and as directed.
S&F in repair sealed compressor suitable for water Cooler of capacity 40 litres complete all as specified and as directed.
S&F in repair sealed compressor reciprocating type suitable for window/split type air conditioner of capacity upto 2 TR complete all as specified and as directed.
S&F in repair sealed compressor rotary suitable for window/split type air conditioner of capacity upto 2 TR complete all as specified and as directed.
S&F in repairs thermostat for window type AC, capacity upto 2 Ton complete all as specified and as directed.
S&F in repairs air filter plastic type suitable for window type AC and split AC, capacity upto 2 TR complete all as specified and as directed.
M&L for servicing of window type AC capacity upto 2 Ton at site with cleaning, oiling, greasing including testing of capacitor relay and retightening of connections, suction line testing and hand over the machine to the user in smooth functional condition complete all as specified and as directed.
All as per Item No 138 above but split type AC.
S&F in repairs condenser fan for window type AC upto 2 Ton capacity complete all as specified and as directed.
S&F in repairs condenser fan for split type AC upto 2 Ton capacity complete all as specified and as directed.
S&F in repairs 2.5mfd capacitor for indoor split unit complete all as specifed as directed.
S&F in repairs blower fan for split type AC upto 2 Ton capacity complete all as specified and as directed.
S&F in repairs running capacitor of 2.5 MFD capacity complete all as specified and as directed.
S&F in repairs running capacitor of 4 MFD capacity complete all as specified and as directed.
S&F in repairs running capacitor of 6 MFD capacity complete all as specified and as directed. .
S&F in repairs running capacitor of 10 MFD capacity complete all as specified and as directed.
S&F in repairs running capacitor of 36 MFD capacity complete all as specified and as directed. .
S&F in repairs running capacitor of 45 MFD capacity complete all as specified and as directed.
S&F in repairs running capacitor of 50 + 4 MFD dual capacitor complete all as specified and as directed.
S&F in repairs, running capacitor of 60 + 4 MFD dual capacitor complete all as specified and as directed.
S&F in repairs starting capacitor of capacity 80 to 100 MFD complete all as specified and as directed.
S&F in repairs PCB board suitable for upto 2 Ton capacity, split type AC complete all as specified and as directed.
S&F in repairs drain pipe suitable for upto 2 Ton capacity, Split type AC complete all as specified and as directed.
Attending complaints of any nature for defective AC of various capacity split/ window type AC and rectification of defects including necessary dismantaling and taking out for repairing and refixing at the site and replacing spares as required for smooth function complete all as specified and as directed. Note : Spares shall be measured and paid separetely under relevant items of this schedule.
All as per item No. 155 above but water cooler of various size and capacity.
All as per item No. 155 above but Refrigerator of various size and capacity.
Dismantling and taking out voltage stablizer transformer unit, 1 KVA capacity, electric circuit board, all cable connections, complete overhauling of the system including repairing/replacement of push on switch, transistor, capacitor, relay transistor, diode, condenser, zener, pre-set, IC, 12 volt transformer, 24 Volt transformer, voltmeter, PVC connector, indicator lamp, cutout, MCB, and any other parts as required for proper functioning of stabilizer complete alongwith testing, commissioning including transportation from site to workshop and back complete all as specified and as directed.
All as per item No. 158 above but of capacity 2 KVA to 3 KVA.
All as per item No. 158 above but of capacity 4 KVA to 5 KVA.
S&F in repairs sheet metal enclosure, single pole and neutral with two pin and earth plug complete with one single pole MCB, 32 Amps, 240 volts complete all as specified and as directed.
Dismantling, Shifting and Refixing of 1.5 TR to 2 TR, Split type AC including gas charging with required type of refrigerant in the unit complete all as specified and as directed.
S&F in repairs condenser coil suitable for refrigerator upto 350 litres capacity complete all as specified and as directed.
S&F in repairs swing motor for louvre shutter complete all as specified and as directed.
S&F in repairs remote control operating device suitable for split type AC upto 2 Ton capacity complete all as specified and as directed.
Attending of complaints of only leakage of R-410/R-32 gas for split type AC and rectification on site and charging of refrigerant in system complete all as specified and as directed.
Supply only pcb for inverter refrigerator complete all as specified & as directed by Eng in Charge
S&F in repair pcb board for outdoor unit for inverter type split ac upto 2 ton complete all as specified & as directed.
S&F in repair pcb board for indoor unit for inverter type split ac upto 2 ton complete all as specified & as directed.
S&F in repair sealed compressor suitable for Deep freezer of capacity 320 litres complete all as specified & as directed.
Over hauling & servicing the solar water heater 100/200 ltr capacity by repair / replacing the spares and blocks in the solar cells removed by the acid cleaning and damaged solar cells to be replaced as directed. Note: Supply and replacement of spares will be measured and paid separately.
Supply and replacement of Anode for solar water heater 100/200 Ltr capacity as per exisiting type.
Supply and replacement of solar gasket as per exisiting type.
Supply and fixing in repairs Bib taps suitable for bore dia of pipe 15 mm, fancy type chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule .
S&F in repairs Stop valves, 20 mm Bore dia of pipe, fancy type, chromium plated cast copper alloy, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.
M&L for Point wiring for 15 Amps S/S combination complete with 2 runs of 2.5 sqmm , PVC insulated, unsheathed FRLS cable 1100 volts grade, multi stranded copper conductor drawn in existing PVC conduit on surface/ in wall/ roof etc. and including provision of one run of PVC insulated 2.5 sqmm copper conductor for earth continuity and connected to common earth dolly and pressed steel terminal boxes made out of 1.6mm thick MS sheet concealed in wall and laminated sheet cover of 3mm thick on top for housing the switch socket complete and taking down existing point wiring except PVC conduit all as specified and directed.
Sub main wiring with 2 runs of 4sqmm PVC insulated, unsheathed FRLS cable,1100 volts grade, multi stranded copper conductor, drawn through and including suitable size of PVC conduit pipe and accessories on surface/wall/ roof etc. with one run of PVC insulated, 4 sqmm FRLS cable, copper conductor for earth continuity conductor and removing existing u/s sub main wiring complete all as specified and as directed.
M&L for servicing of Diesel engine generating set of various capacity 25 to 62.5 KVA of Make:- Kirloskar/ Ruston/Cummins/Jacksons, Air cooled/Water cooled and carrying out to B check DG set as per manufactures maintenance norms and also carrying out following complete all as specified and as directed :- (a) Dismantling the engine parts/components as required and cleaning thoroughly by degreasing and de-carbonising all the rotary and static parts (b) Checking of all rotary and static parts of engine and adjust/repair the defects as required for satisfactory running of DG set. (c) Changing engine oil of DG sets. (d) Change of air filter. (e) Change of fuel filter, oil filter and by pass filter. (f) Change of water separator Note: Engine oil shall be issued under schedule 'B' free for filing and spare parts required to be replaced shall be measured and paid under relevant item of the schedule 'A' (g) Testing of DG set after servicing as per direction of Engineer-in-charge for satisfactory performance. (h) Cleaning the external surface of DG Set and near by floor area all as directed by Engr in charge. (j) Cleaning the diesal Tank of DG Set incl drain out diesel and after clean the tank pouring diesel Note :- (i) Any minor parts such as screw, washer, split ring, circlips and etc shall be supplied by the contractor and rate for the same shall be deemed to be included in the unit rate quoted. (ii) If any major part is found defective and needs replacements then new parts shall be measured and paid separately as "Supply only" under respective items of this schedule with Prior approval of Engr in charge. (iii) DHPP and lubricating oil required for servicing and testing will be supplied by the Department under Sch 'B' for free for filling. (iv) Completion of repair work should be carry out within 2 days by deploying maximum labour and resourses being the essentialness of the work.
All as per ser item No. 178 above but for DG Set of capacity 82.5 to 160 KVA. Make:- Kirloskar/Ruston/ Ashoka Leyland/Greaaves
All as per ser item No. 178 above but for DG Set of capacity 180 to 250 KVA. Make:- Kirloskar/Ruston/ Ashoka Leyland /Greaaves
M&L for repair and servicing of governor hydraulic and calibrating complete including supply and replacement of Governor hydraulic repair kit for DG set of capacity 30 KVA to 62.5 KVA complete all as sprecified and as directed.
M&L for repair and servicing of turbo charger and calibrating complete including replacement of turbo charger repair kit with new one (Make : HOLSET) of capacity 30 KVA to 62.5 KVA complete all as sprecified and as directed. Make : Kirloskar/MEADOWS/JACKSONS
M&L for repair and servicing water pumps assembly including replacement of water pump repair kit bearing (NDE) with new one for Meadows/Kirloskar engine of capacity 25 KVA to 62.5 KVA complete all as sprecified and as directed. Make : Kirloskar/MEADOWS/JACKSONS
M&L for repair and servicing to fuel injection pump by replacing fuel pump repairs kit and calibration complete for Meadows/Kirloskar Engine of capacity 25/30 KVA to 62.5 KVA complete all as sprecified and as directed. Make : Kirloskar/MEADOWS/JACKSONS/RUSTOR/GREAVES
Supply only V belt No. B-42. for Meadows/Kirloskar/Cummins engine to be incorporated as and when reqd for 25 KVA DG Set to 82.5KVA DG Set complete all as sprecified and as directed. Make : Fenner
PAUL ENTERPRISE (BID ID -3121280)
AFTAB ENTERPRISES (BID ID -3119968)
FREEZCON (BID ID -3120133)
Bimal Trading Company (BID ID -3120391)
M/s GANDHESWAR PHUKAN (BID ID -3120625)
M/s PRABIR ENTERPRISE (BID ID -3121530)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .