Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC PLOT NO 74 INDUSTRIAL AREA PHASE 1 CHANDIGARH | NA | NA | 160001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹1.6 Cr+₹19.0 L (13.0%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹1.7 Cr+₹24.0 L (16.4%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | Rejected-Technical CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | - | Rejected-Technical Does not qualify eligibility criteria. |
Tender Value
₹1.6 Cr
EMD Value
₹3.3 L
Closing Date
1 Sept 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Er. Dinesh Tandon
Executive Engineer, Electrical Division No. 2, 1st Floor Additional Deluxe Building Sector- 9/D, Chandigarh.
As per NIT
2025_CHD_87660_1
E2/25/76
Open Tender
Electrical Works
Percentage
90 days
Chandigarh
As per NIT
3 documents required · 3 mandatory
₹0
₹3.3 L
Chandigarh
14 Oct 2025
1 Aug 2025
1 Sept 2025
1 Aug 2025
1 Sept 2025
6 Aug 2025
6 Aug 2025
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | DSR item No.2.22 Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. | 7 | Each | 305 | ₹2,135 |
| 2DSR item No. 3.13Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminum bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminum strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required | |||||
| 2.01 | 1000 A 50kA SC for 1 sec | 20 | PM | 25,266 | ₹5,05,320 |
| 3DSR item No. 4.1 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. | |||||
| 3.01 | 300 mm width X 50 mm depth X 1.6 mm thickness | 200 | PM | 812 | ₹1,62,400 |
| 3.02 | 600 mm width X 62.5 mm depth X 2.0 mm thickness | 100 | PM | 1,529 | ₹1,52,900 |
| 4 | DSR item No. 5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. | 6 | Each | 7,808 | ₹46,848 |
| 5 | DSR item No. 5.9 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) | 25 | PM | 150 | ₹3,750 |
| 6 | DSR item No. 5.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. | 60 | PM | 255 | ₹15,300 |
| 7DSR Item No.9.1 Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1KV grade as required. | |||||
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
Tender Document • 17.15 MB
76corri.pdf
Tender Document • 0.45 MB
BOQ_107376.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .