Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹4.2 L+₹55,125 (15.1%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹5.1 L+₹1.4 L (39.6%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹8,000
Closing Date
27 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) (AF) Chimney Hills, Bangalore
Asst Garrison Engineer I AF Chimney Hills Chikkbanavara Post Bangalore, PIN- 560 090
MAINTENANCE AND REPAIR TO PERIMETER LIGHTS AT 58 SU CHIMNEY HILLS
2020_MES_382485_1
8402/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AGE (I) (AF) Chimney Hills, Bangalore
As per tender documents
8 documents required · 8 mandatory
₹300
AGE (I) (AF) Chimney Hills, Bangalore
₹8,000
Yes
20 Jan 2021
17 Oct 2020
30 Nov 2020
17 Oct 2020
27 Nov 2020
24 Oct 2020
17 Oct 2020 - 23 Oct 2020
60 days
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified. Note : A deduction of 10% shall be made from total computed volume of filling to cater for bulkage irrespective of machinery used for ramming.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as directed.
Supply, laying, jointing, testing and commissiong LT under ground, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, heavy duty electric cables with stranded aluminium conductor 1100 volts grade confirming to IS, laid in trenches, ducts, passing through pipes or fixed to wall with suitable clamps/saddles etc., including cable glands, terminal socket and connecting of size 2 Core x 10 Sqmm including taking out/down old damaged/unserviceable LT UG XLPE cable complete all as specified and as directed.
All as per item No. 4, here in before but for LT UG XLPE cable of size 4 Core x 16 Sqmm including taking out/down old damaged/unserviceable LT UG XLPE cable complete all as specified and as directed.complete all as specified and as directed.
Supply and laying common burnt clay, building bricks, sub class 'B' designation 75 and laid in trenches for cable protection as specified and directed.
Supply and spreading in layers, clean, dry, fine stone dust in trenches for cable cushioning to LT UG cable all as specified in clause 19.75 of SSR part -I complete all as specified and directed
Supply and laying galvanised steel pipe 40mm bore dia light grade including all fittings complete laid in trenches or in floor, for road crossing/fixed on wall/on pole for protection of LT UG cables all as specified and as directed
Material and Labour for cutting bituminous/concrete road width not exceeding 40 cm and depth not exceeding 60 cm for laying of pipes on road crossing for cable protection and making good with cement concrete 1:2:4, type, B-2 (using 40mm garded stone agregate) not less than 150mm thick to match adjacent surfaces over a layer of 150mm thick hard core of broken stone or boulder (granite/basalt/trap) of gauge not exceeding 63 mm, deposited, spread and levelled in layers, watered and rammed size including returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soils and removing of excavated materials not exceeding 50m complete all as specified and as directed
Taking down the unserviceable/defective street light/perimeter light/Garden light/Bollards/ Flood lights fittings of any wattage, from the buildings/poles/post tops for repair and refixing the same after carrying out necessary repairs including attending complaints received through online for non functioning lights complete all as specified and as directed Note: Replacement of spares like LED driver, surge arrestor, etc shall be measured and paid seperately as supply only under relevant items here in after
Supply and fixing in repairs energy saving, environmental friendly, long life, exclusive innovative, die cast aluminium LED Flood Light luminaire, 200 Watt capacity, with IP 66 protection, suitable for highlighting architectural features or retail spaces complete all as specified and as directed Make : Havells Model No: JETAVALOURFL200WLED757PINTNBLTG or equivalent in Philips/Crompton
Supply and fix in repairs new generation energy saving and environmental friendly long life LED street light, 60 watt, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07 complete all as specified and as directed Make: Havells Model No ENDURAPEARLNEOSL60WLED757PASYTOPC or equivalent in Philips/Crompton
Supply only LED driver suitable for 60 watt street light fitting, 240 Volts, 50 Hz complete all as specified and directed
Supply and fix in repairs hard PVC junction box of size 200x150x150 mm weather proof with three phase and neutral link connector and necessary cable gland- 2 Nos for LT UG cable 10/16 sqmm 2/4 core and locking arrangement and fixing with existing PCC / steel tubular electric poles above the coping with suitable MS clamps, nuts & bolts and necessary electric connection etc., complete all as specified and directed Make : Havells/L&T/Seimens
Material and Labour for Sub main wiring complete with two runs of 1.5 sqmm single core FRLS PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor drawn through and including suitable size PVC rigid conduit/PVC casing and caping fixed to walls / roofs / floors etc., with one run of 1.5 Sqmm single core multistranded PVC insulated unsheathed FRLS 1100 volts copper conductor as earth continuity conductor all as specified including dismantling unserviceable sub main wiring including accessories. Note: Two runs of wire, one run of earth wire and one run of PVC rigid conduit/casing caping shall be measured as one running metre
Material and Labour for wiring with two runs of 1.5 sqmm single core FRLS PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor on existing PVC conduit fixed on pole from junction box to light fitting including dismantling unserviceable cable/wiring including accessories. Note: Two runs of wire/cable shall be measured as one running metre
Supply and fix in repairs 40 mm dia medium grade GI pipe bracket 1.2 mtr long bend to shape suitable for fixing street light to PCC/steel pole including suitable size MS clamps, bolts, nuts, washers, etc., complete all as specified.
Supply and erecting of steel tubular swaged pole 9.0 mtr long, type 410-SP-31 complete with CI base plate, finial taper plug, bolts, nuts and screws etc including necessary excavation and earth work in any type of soil of size 600 x 600 x 1500mm, PCC 1:3:6 type C-2 in foundation, PCC 1:2:4 type B-1 in plinth block/coping disposal of surplus soil up to 50 M, one shop coat of painting inside with black bitumen paint and out side with two coats of aluminum paint over one coat of red oxide Primer and numbering the poles and applying 300mm wide black & white alternate striping with synthetic enamel paint up to 1.5 Mtr height from base including taking out old unserviceable pole any type complete all as specified and as directed.
Material and Labour for painting to steel tubular street light poles from top towards bottom with one coat of aluminium paint for first 5.5 mtr, for next 0.45 mtr with Navy Blue colour synthetic enamel paint and for further 1.10 mtr with white colour synthetic enamel paint and finally last 0.45 mtr on coping with yellow & black colour synthetic enamel paint in tiger cross pattern and writing pole No in white colour paint over black painted round label above the Navy blue painting including applying one coat of aluminium paint to GI bracket/pipe etc., pasting red colour fluorescent reflective stricker on the poles at the height of 1.5 metre above the coping complete all as specified and as directed.
manoj builders and consultants
KHUSHI CONSULTANTS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .