Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.7 LAccepted-AOC A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L1 | Accepted-AOC AMOUNT QUOTED LOWEST | |
| 2 | L2₹31.7 L+₹2.0 L (6.73%)Rejected-Finance | L2 | Rejected-Finance QUOTED AMOUNT NOT LOWEST | |
| 3 | L3₹35.3 L+₹5.6 L (18.7%)Rejected-Finance PLOT NO 17 GF PRATAP NAGAR NEW DELHI 110064 | WEST | DELHI | 110064 | L3 | Rejected-Finance QUOTED AMOUNT NOT LOWEST | |
| 4 | L4₹36.7 L+₹7.0 L (23.4%)Rejected-Finance | L4 | Rejected-Finance QUOTED AMOUNT NOT LOWEST | |
| 5 | L5₹37.1 L+₹7.4 L (24.8%)Rejected-Finance | L5 | Rejected-Finance QUOTED AMOUNT NOT LOWEST |
Tender Value
₹43.6 L
EMD Value
₹87,200
Closing Date
21 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE DELHI CANTT
HQ CWE Delhi Cantt Delhi Cantt Delhi-110010
SPL REPAIR TO BLDG NO T 22 SINGLE ORS LIVING ACCN AT STN HQ CAMP UNDER GE EAST DELHI CANTT 110010
2022_MES_504956_1
CWE/D-51/2021-22
Open Tender
Civil Works
Item Rate
120 days
Delhi Cantt
As per NIT
7 documents required · 7 mandatory
₹500
GE EAST DELHI CANTT
₹87,200
Yes
2 Apr 2022
1 Feb 2022
22 Feb 2022
1 Feb 2022
21 Feb 2022
15 Feb 2022
60 days
Amount
Taking down cement or cement lime plaster of any description on brick or stone walls and concrete surface etc including raking out joints hacking for key scrubbing down with water etc complete all as specified.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sqm each complete all as specified.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sqm but n. exc 4 sqm each complete all as specified.
Demolition of cement concrete (unreinforced) in ground floor and paving near 15 cm thick (below or above ground level) complete all as specified.
Dismantling framed timber scantling in fillets, rails, posts, rafters, purlins, etc over 40 sq cm in section complete all as specified.
S&F rolled mild steel Fe-410w (Gde-E-250) quality 'B' Roof trusses (framed ) , trussed, purlins, posts, rails and fastening (Beam, tee, angle, channel or flat sections) including distance pieces cleats etc complete all as specified.
S&F Pre-Painted galvanlume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws including dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coveringscomplete all as specified.
S&F Pre-Painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws including Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified.
M&L false ceiling with 4mm thick 'E' Board fixed over GI powder coated inverted Tee or 'L' section suspended from ceiling with 3mm thick GI wire tie with ceiling/trusses with suitable arrangement complete all as directed and specified (a) Main runner/ Cross tee size 29x24.7x0.8mm (b) Wall angle of size 22.2x22.2x0.65mm (C) Size of grid 600x600mm (d) Two coats oil bound distemper one side of board (e) Powder coating on exposed side of tee/angle including dismantling of old ceiling any size and description complete all as specified and as directed
M & L for 50mm thick cement concrete type B -1, 1:3:6 using 20mm graded aggregate as in subbase complete all as specified.
M & L for machine cut kota stone slab flooring 18-20mm thick over cement screed base 15 mm thick in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.
M & L for kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar laid over cement screed 10mm thick in CM 1:4, and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.
M & L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15 mm thick screed bed in CM 1:6 and dismantling of old tiles with backing complete all as specified.
M & L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in vertical surfaces etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick screed bed in CM 1:4 and dismantling of old tiles with backing complete all as specified.
M&L for 35 mm thick flush shutters, solid core construction with block board core and ply wood face panel, commercial type on both sides complete all as specified.
M&L for second class hard wood 35 mm thick skeleton shutters, open rebated and prepared to receive glass, guaze etc edges of framing plain chamfered or rounded fitted with cut and mitred beads of shutters as specified.
S & F steel windows with side hung shutters box type including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
S & F steel windows with side hung shutters box type including projecting type hinges with steel handle, and steel peg stay, complete but without glazing bars, dovetailed or welded complete all as specified and as directed.
M & L for sheet glass 3.0mm thick, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with staless wire staples complete all as per specified and as directed
S&F 100 mm size butt hinges medium weight complete all as specified.
S&F 150 mm long mild steel barrel tower bolt, stove enamelled blank with bright bolt and fixed complete all as specified and directed.
S&F 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with brigh bolt not less than 12 dia with and incluidng 1 minimum of 6 bolts and nuts four or bolt plate and tow on staple plate complete all as specified.
S & F 150 mm long mild steel pressed handle oval type, stove enamelled black complete all as specified and as directed.
M&L 75mm thick cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in plinth protection & finished the surface even & smooth w/o using extra cement complete all as specified and as directed.
M & L for brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 including demolition of Brickwork built in cement mortar including all quioins, arches, pillars complete all as specified and as directed.
S&F in repairs Harrison rails, anodised aluminium alloy, chromium plated with fixing brackets, stops, rollers etc complete all as specified and as directed.
M&L for rendering 15 mm thick in CM 1:6 finished fair and even without using extra cement complete all as specified.
M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces (Cement plaster 1:4) finished fair and even without using extra cement complete all as specified and as directed.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified.
M&L for two or more coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified and as directed.
M&L for preparation of new wooden surfaces & applying 2 coats of synthetic enemel paint over a coat of wood primer complete all as specified.
M & L for applying two coats of synthetic enamel ordinary tint paint inclduing red oxide primer and prepartion extra complete on new steel or iron surfaces of any description, over 10cm in width or grith, not otherwise described complete all as specified.
Demolition, Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified.
M&L providing cement concrete 1:2:4 Type B1 using 20mm graded aggregate in roof kerbs of mud stops rounded or chamfered on edges complete all as specified
M&L Hardcore of broken bricks gauge exc 63mm but n.exc 100mm deposited, spread and levelled in layers n.exc 15cm thick, watered and rolled /rammed to true surfaces complete all as specified
Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed.
Taking down old unserviceable point wiring from existing conduit/ batten ( light, fan, socket or power point) complete such as switches, celing rose, pandent holder, regulator, sockets and light fittings etc and removing the material from site and making good the disturbed surface of wall/ceiling etc as original complete alll as specified and directed
M&L for point wiring complete with 1.5 Sq mm (nominal area) FRLS, PVC insulated un-sheathed and stranded copper conductor cable ISI marked and including PVC concealed conduit ISI marked of size not less than 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers except conduit junction box (junction box will be of MS) including FRLS, PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and incl Metal flush box of suitable size for fixing switches/sockets/fan regulator etc , with and including bakelite sheet 3 mm thick of suitable size and making good surface as original by plastering, whitewash/colour and distemper etc complete all as directed for the following :-(Note : The cost of modular type Metal boxes and modular accessories like cover plates will be included in quoted rate.): (a) one light point / fan point/ wall fan point/ bell/ buzzer/socket on indepent board controlled by one 1-way switch/ bell push.
All as per srl item No.39 but for one socket outlet point 5 amps on the same board.
All as per srl item no. 39 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for power point. Note : The point wiring for power point will not be mixed with light/fan point circuit or not in the same conduit pipe.
S&F switch piano flush type, 6 amps one way,SP,230 volts AC all as directed.
S&F switch piano flush type, 16 amps one way,SP,230 volts AC all as directed.
S&F socket outlet 6 amps 5 pin , all as directed.
S&F socket outlet 6&16 amps 6 pin all as directed.
S&F piano type Step fan regulator, 120 watts single module all as directed.
Supply and fixing of Ceiling rose, insulated body, 3 terminal, 240 volts, 6 Amps complete all as directed.
Supply and fixing of LED tube light fitting 22 W to wall mounting type with and including all electric connections with two core PVC insulated, PVC sheathed copper conductor flexible cable complete all as specified.
S&FRecess/Surface mounting 2x2 square flat panel ultra slim scoop LED light 36/40 W warm/cool white with driver/transformer etc suitable for Grid ceiling/Gypsum board/POP ceiling incl making electric connection complete as as directed.
S&F LED street light fittings 45W LED suitable for building security light, pressure diecast aluminium roadway luminaire with high power LEDs and HF electronic driver complete all as directed.
Supply and fixing security light fitting bracket, 1.5 mtr long made out of galvanized iron pipe of 40mm dia size light grade complete with nut, bolts, washer etc inclusive of one primer coat, one under coat and one finishing coat of silver paint complete all as directed.
S&F ventilation/ Fresh air fan 250mm sweep made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding including hole arrangement in window/wall of suitable size complete all as specified and as directed.
S&F ceiling fan 1200mm sweep, Copper winding,240 Volts. 50 Hz BEE five star rating complete and depositing the old u/s ceiling fan to MES store yard all as specified.
M&L for Sub main wiring with 2 run of 6.0 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to separate PVC concealed conduit 25 mm dia with and including 6.0 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble complete all as directed. Note : 1. The conduit and conduit accessories shall be measured and paid as one unit. 2. The cost of earth wire is included in the quoted rates.
S&F in replacement of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 08 way, 240 volts with bus bar rating 200 Amps including dust and vermin proof and making all necessary connections complete all as directed.
Supply and fixing in replacement of MCCB incommer Distribution Board ( Vertical Load line DB) double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, VTPN 04 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB as incommer and MCB as outgoing and making all necessary connections and taking out the old unserviceable DB complete all as directed. Note:- MCCB & MCBs will be measured and paid separately
S & F of MCCB, 415 volts, three pole of cap 125 Amps, 10 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including necessary spreader / thimbles of suitable size and making connections complete all as directed.
Supply and fixing of MCB SP, C Curve type, 10 KA, 10 to 32 Amp, with over load and short circuit protection complete all as directed.
Supply and fixing of MCB SPN C Curve type, 10 KA, 40 to 63 Amp, with over load and short circuit protection complete all as directed.
S&F XLPE insulated armoured heavy duty U/G aluminium conductor cable served with an inner sheathing of PVC tape armoured with galvanised steel strip wire or tape and overall PVC sheathed of size 50 Sqmm 3 1/2 core.
Excavation in trenches in soft / loose soil not exceeding 1.5 meter depth and not exceeding 1.5 meter wide and getting out including trimming of sides complete all as directed.
Material and labour for brick protection to cable using old size class 'B' bricks, laid flat, dry butt jointed, laid lengthwise perpendicular to the axis of cable complete all as directed.
Material and labour for sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable complete all as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as directed.
Removal of excavated material n exc 50m and depositing n exc 1.5m above starting point complete all as specified and as directed..
S&F Galvanised Steel tubing light grade of size 40mm bore. Make : Prakash/Jindal/TATA.
M&L for earthing complete with GI earth plate electrode 600 mmx 600mm x 6mm thick burried directly in ground not less than 2.25 mtrs below ground level, with top edge of the plate not less than 1.5 mtrs deep below normal ground level, connected to galvanised earth wire 4mm by means of bolts, nuts check nuts to earth test point including necessary PCC 1:2:4 type B-1 pit, cover frame, GI pipe 15mm dia light grade for protection of earthing lead and GI pipe 20 mm dia for watering pipe with funnel, wire mesh, salt, charcoal dust and excavation complete all as directed.
VIKRANT CONSTRUCTION CO.
M/s Durga Traders
M/S GR construction compony
RAMGARHIA CONSTRUCTION CO
MAA SANTOSHI ENTERPRISES
M/S HARINDER SINGH
imran construction company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .