Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-AOC NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹36.1 L+₹1.6 L (4.67%)Rejected-Finance | L2 | Rejected-Finance Quoted rates higher than L1 bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical Tenderer not enlisted in eligible category b(ii). Hence T bid rejected. |
Tender Value
₹39.9 L
EMD Value
₹79,800
Closing Date
26 Nov 2021, 6:00 pmClosed
CWE AF TRIVANDRUM
CWE AF TRIVANDRUM HQ SAC IAF COMPLEX AKKULAM THURUVIKKAL POST TRIVANDRUM 11
Repair maintanace of transformers switch gears 2/4/6 pole structure LT Panels and connected works at AF Stn Thanjavur
2021_MES_484911_1
CWE(AF)/TVM 82384 Repair transformer thanjavur
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Thanjavur
Class D category b(ii)
7 documents required · 7 mandatory
₹500
GE AF Thanjavur
₹79,800
Yes
28 Dec 2021
29 Oct 2021
29 Nov 2021
29 Oct 2021
26 Nov 2021
12 Nov 2021
30 Oct 2021 - 5 Nov 2021
Amount
SCHEDULE 'A'
Supply, Laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 10 sqmm 2 core with all fixing & connecting accessories including taking down old unserviceable cable.
All as per Item No 2 here-in-before but 16 sqmm 2 core
All as per Item No 2 here-in-before but 16 sqmm 4 core
All as per Item No 2 here-in-before but 35 sqmm 3.5 core
All as per Item No 2 here-in-before but 50 sqmm 3.5 core
All as per Item No 2 here-in-before but 95 sqmm 3.5 core
All as per Item No 2 here-in-before but 120 sqmm 3.5 core
All as per Item No 2 here-in-before but 150 sqmm 3.5 core
All as per Item No 2 here-in-before but 185 sqmm 3.5 core
All as per Item No 2 here-in-before but 240 sqmm 3.5 core
All as per Item No 2 here-in-before but 300 sqmm 3.5 core
All as per Item No 2 here-in-before but 400 sqmm 3.5 core
Supply and lay HTcable, XLPE insulated screended PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 11000 volts grade (earthed cable) with stranded aluminium conductor of size 120 sqmm 3 core all as directed. Note: (i) Necessary excavation & earth work and cable protection items shall be measured and paid seperately vide relevant items of this schedule. (ii)The routine tests and acceptance tests as per IS 7098 (Part –II) shall be carried out at factory premises in presence of Accepting Officer’s rep. appointed by Accepting Officer, who shall directly report to him on quality control issues/ matters before dispatch of material and cost of such tests shall be borne by the contractor and their quoted rates shall be deemed to include for the same.
All as per Item No 14 here-in-before but 95 sqmm 3 core
Supply and laying in replacement 100 mm bore, steel tubings galvanised, light grade with all fittings fixing along the electric laing in trench or pole / wall for protection of cable complete all as specified and as directed.
Supply and laying in replacement 80 mm bore, steel tubings galvanised, light grade with all fittings fixing along the electric laing in trench or pole / wall for protection of cable complete all as specified and as directed.
Supply and laying in replacement 50 mm bore, steel tubings galvanised, light grade with all fittings fixing along the electric laing in trench or pole / wall for protection of cable complete all as specified and as directed.
Supply and laying in replacement 40 mm bore, steel tubings galvanised, light grade with all fittings fixing along the electric laing in trench or pole / wall for protection of cable complete all as specified and as directed.
Excavation in trenches not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out in soft/loose soil for taking up / laying under ground electric cable or for pole etc complete all as specified and as directed.
Excavation in trenches l not exc. 1.5 metre wide and exc. 1.5 metre but not exc 3 m in depth and getting out in soft/loose soi for taking up / laying under ground electric cable or for pole etc complete all as specified and as directed.
Returning and filling in two parts (i) using riddled soil obtain from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. Note:- Excavated soil shall be riddled by using sieve to separate composite partricles etc as per IS 1255 1983 and refilling in trenches as in cable cushioning.
Removing surplus soils to a distance not exceeding 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point all complete as specified and as directed.
Supply and laying Bricks, sub class 'B' old size bricks, laid flat dry with width of the bricks laid to the axis of the cable all complete as specified and as directed.
M & L for providing PCC (1:2:4) type B-1 with 20 mm graded aggregate as in, coping and finishing the surface even and smooth without using extra cement complete all as specified and as directed.
M & L for PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for stay set / Pole / feeder pillar lean concrete etc including fair finish even and fair to exposed surfaces without using extra cement complete all as specified and as directed.
Supply and erecting steel tubular pole complete with cast iron base plate, finial taper plug, nuts and screw as specified, type 410 SP-31, 9 Metre long including two coats of aluminium paint (PCC and earthwork in foundation shall be measured and paid under respective item separately) including dismantling of existing unserviceable pole including demolition of PCC work complete all as specified and as directed.
Supply and erecting steel tubular pole complete with cast iron base plate, finial taper plug, nuts and screw as specified, type 410 SP-55, 11 Metre long including two coats of aluminium paint (PCC and earthwork in foundation shall be measured and paid under respective item separately) including dismantling of existing unserviceable pole including demolition of PCC work complete all as specified and as directed.
S & F for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as directed inclusive of two coats of aluminium paint over a coat of red oxide primer after and including dismantling old unserviceable cross arm etc complete all as specified and as directed.
S & F aluminium conductor steel reinforced (ACSR) of any size stringing and jointing on poles including, binding wires, jointing sleeves, aluminium tap and PG clamp etc after and including taking out old unserviceable ACSR complete all as specified and as directed.
M & L for under ground high tension cable fault finding for exact location by using LT fault locating equipment and trace out the fault complete all as specified and directed Note :- The rate quoted by the contractor shall include the rate for earth work, cable jointing kit and necessary T&P etc.
M & L for under ground low tension cable fault finding for exact location by using LT fault locating equipment and trace out the fault complete all as specified and directed Note :- The rate quoted by the contractor shall include the rate for earth work, cable jointing kit and necessary T&P etc.
M&L in repacement of cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint compelete with jointing material and accessories suitable for 3 core XLPE armoured conductor cable of size 95 Sqmm.
M&L in repacement of cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint compelete with jointing material and accessories suitable for 3 core XLPE armoured conductor cable of size 120 Sqmm to 185 Sqmm.
M&L in repacement of cable jointing kit for 11 KV (earthed) grade cable for Straightthrough heat shrink type joint compelete with jointing material and accessories suitable for 3 core XLPE armoured conductor cable of size 120 Sqmm to 185 Sqmm.
Supply and fix cable route indicator made out of 15x15x6mm GI plate welded with 8 mm x 45cm long GI rod grouted in PCC block 1:2:4 type B1 using 20mm graded stone aggregate of size 15x15x10cm and writing the words 'LT cable' as directed with synthetic enamel paint of two coats over a coat of primer including excavation and earth work all as directed.
Supply and fix cable route indicator made out of 15x15x6mm GI plate welded with 8 mm x 45cm long GI rod grouted in PCC block 1:2:4 type B1 using 20mm graded stone aggregate of size 15x15x10cm and writing the words 'HT cable' as directed with synthetic enamel paint of two coats over a coat of primer including excavation and earth work all as directed.
Material and labour for painting to existing surfaces of HT/LT 11/9 mtr long steel tubular poles with 2 coats of aluminium paint over the existing surface including brackets clamps junction boxes etc including writing of pole number and painting to HT insulator RYB etc all as specified and as directed.
Material and labour Air break switch (GOD) Gang Operated Device horizontal / vertical type, tripple pole, mechanically operated, mounted on nine/twelve FRP insulators and steel frame, with operating mechanism worked from ground level, with operating rod 25mm dia light grade GI pipe, suitabel for current rating upto 200 Amps, HT 11 KV including taking out old unserviceable one and connecting up complete with locking arrangement all as directed .
Material and labour litening arrestors expulsion type complete with all fittings, transmission class discharge capacity 65 kilo amps suitable for 11000 volts complete all as specified and as directed by Engr In Charge.
Mateial and labour pin type, FRP insulator including one galvonised mild steel spindle, two galvonised iron washers and one galvonised iron nut, suitable for 11000 volts grade complete all as specified and as directed by Engr In Charge.
Mateial and labour shackle type,FRP insulator including one galvonised mild steel straps 38 x 5mm two galvonised iron washers and one galvonised iron bolts 20mm, suitable for 11000 volts grade complete all as specified and as directed by Engr In Charge.
Dehydration including filtration of transformer oil on different locations by dehydration plant including testing of samples before and after dehydration and fiteration complete all as specified and directed the dielectric strength to be achieved 60 KV at 4 mm gap after complete dehydration.
M&L for cleaning of complete body of transformer of capacity 315 KVA and painting with two coat dark BS Gray painting & R, Y, B, Black, Green colour coding to insulators complete all as specified and directed
All as per item No 44 but 250 KVA
All as per item No 44 but 100/160 KVA
All as per item No 44 but 200 KVA
Material and labour for filling in with new transformer oil for top up having low viscosity of approved make as per IS 355 of 1992 and di-electric strength 60 KV(after filtration) complete all as specified and directed by Engineer-in-Charge.
Taking down old and UNSV transformer any capacity at different locations in the area of responsibility falls under GE (AF) Thanjavur from two pole strcture/ foundation including disconnecting the LT/HT connection and shifting to workshop and getting back after repair and refixing the same at original location and connecting electrically and commissioning complete all as specified and directed.
M&L Replacement of burnt defective HT/LT copper coil of different type capcity winding with superior qulity enamelled copper winding wire/strips of approved of suitable size/guage and Nos of turns maching with the existing impendence and insulated including all allied materials such as cork sheets, fiver glass insulation/paper insulation cotton, empire tape and wooden, bolts, nuts and washer (Brass) soldering and other packing material etc required for entire winding of coils all as specified and directed by Engineer- in-Charge.
M&L Replacement of HT bushing porcelain, vitreous with brass spindle, threaded with washers nuts, lock nut and rubber seal suitable for transformer of any make /type/capacity in repairs all as specified and directed by Engineer-in-Charge
M&L Replacement of LT bushing porcelain, vitreous with brass spindle, threaded with washers nuts, lock nut and rubber seal suitable for transformer of any make /type/capacity in repairs all as specified and directed by Engineer-in-Charge
M&L in repairs for Top gasket sheet made out of 2 mm thick cork sheet with suitable GI bolts, nuts, washers for top of transformer any capacity complete all as specified and directed
M&L in repairs for Dehydrating breather assembly Aluminium/CI body of standard size filled with silica-gel for transformer of any capacity complete all as specified and directed
M&L in repairs for Temperature gauge circular dia type of standard size for transformer of any capacity complete all as specified and directed
Taking down old and unserviceable VCB/Load break switch any capacity at different locations in the area of responsibility falls under GE (AF) Thanjavur from foundation including disconnecting electrically and shifting to workshop and getting back after repair and refixing the same at original location and connecting electrically and commissioning complete all as specified and directed.
Supply and fix in replacement Tulip support 1250 amps Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement Tulip complete (15 Fingure) 1250 amps Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement Phase barrier 360 x 545 T=3mm Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement support insulator Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement close/trip coil 24 volt/30 volt/110 volt/220 volt DC Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement coil 24 volt/30 volt/110 volt/220 volt DC Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement aux contact Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement Motor assembly 110 volt / 220 volt AC/DC Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement Micro switch with ball or without ball Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement anti pumping relay 110 volts AC/DC Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Total of Schedule 'A'
Schedule of Credit (Minus)Rs. 71258.00 NOTE: Bidder shall insert credit amount Rs 71258.00 in the basic rate column (Green field under Col-5 )
Sub Total of Schedule of credit
EASHWAR ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .