| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹5.4 LAccepted-AOC AT POST RAY DIST RANCHI 829209 | RAY | RANCHI | JHARKHAND | 829209 | ₹5.4 L Quoted ₹4.6 L | L-1 | Accepted-AOC As per Recommendation of TC and Approval of Competent Authority |
| 2 | Rejected-Technical AT RAY COLLIERY POST CHURI DIST RANCHI 829209 | HAZARIBAGH | JHARKHAND | 829209 | - | - | Rejected-Technical As Per NIT |
| 3 | Rejected-Technical | - | - | Rejected-Technical As Per NIT |
| Sl No | Description | Qty | Unit | M/S DEVNANDAN SHARMA L1 |
|---|---|---|---|---|
| 1.00 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size 1 of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required for end termination in tubular pole upto 35 sq mm cable. For tubular poles installed in weighbridges and tower lights | 20 | nos | 2,525.88 ₹50,517.60 |
| 2.00 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required for end termination in tubular pole upto core 70 sq mm cable. For Generator power cable and Transformer power cable and various establishments | 30 | Set | 2,978.87 ₹89,366.10 |
| 3.00 | Supplying of double compression nickle plated brass cable glands for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required.4 C x 35 sq mm(31 mm) | 20 | nos | 822.56 ₹16,451.20 |
| 4.00 | Supplying of double compression nickle plated brass cable glands for following size of PVC Insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required.4 C x 70 sq mm(38 mm) | 30 | nos | 1,169.82 ₹35,094.60 |
| 5.00 | 600 mm X 600 mm X 6 mm thick G.I. plate for fixing of gland and making of 31 mm or 38 mm dia hole by drilling or welding as required for Generator and Tower light pannels. | 20 | nos | 1,571.4 ₹31,428 |
| 6.00 | Removing previously connected cables from over head line, Generetor panel and cleaning cable to be suitable for Glanding and Termination and again Connecting the cable in proper sequence with Proper fixing of Gl plate in proper hole of 31 mm or 38 mm dia. | 50 | Job | 927.32 ₹46,366 |
| 7.00 | Providing of 70 sq mm 4 core isi marked, upto 1.1 kv grade Alluminium armouredcable for changing of service cable where ever required. | 30 | Mtr | 1,086.4 ₹32,592 |
| 8.00 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of size not exceeding 35 to 95 sqmm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. As required | 30 | Mtr | 280.33 ₹8,409.90 |
| 9.00 | Providing of 35 sq mm 4 core isi marked, upto 1.1 kv grade Alluminium armouredcable for changing of service cable where ever required. | 30 | Mtr | 598.49 ₹17,954.70 |
| 10.00 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of size upto 35 sqmm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. As required | 30 | Mtr | 268.69 ₹8,060.70 |
Tender Value
₹5.6 L
EMD Value
₹6,980
Closing Date
21 Apr 2025, 6:30 pmClosed
Staff Officer (EnM),Magadh -Sanghmitra Area
Office of The General Manager M-S Area Bachra, 829201.
Fitting of double compression niclkle plated brass cable gland with end termination by heat shrinking kit of bus bar panels installed in diesel generators and transformers at Balumath, Bukru and Phulbasiya siding for earthing of armoured power
2025_CCL_334026_1
GM(MS)/SO(EnM)/e-NIT/25-26/05
Open Tender
Electrical and Maintenance Works
10 days
Office Of the Project Officer Magadh OCP, M-S Area
Please Refer NIT
4 documents required · 4 mandatory
₹6,980
31 Dec 2025
11 Apr 2025
22 Apr 2025
11 Apr 2025
21 Apr 2025
11 Apr 2025
11 Apr 2025 - 18 Apr 2025
Amount
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size 1 of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required for end termination in tubular pole upto 35 sq mm cable. For tubular poles installed in weighbridges and tower lights
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required for end termination in tubular pole upto core 70 sq mm cable. For Generator power cable and Transformer power cable and various establishments
Supplying of double compression nickle plated brass cable glands for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required.4 C x 35 sq mm(31 mm)
Supplying of double compression nickle plated brass cable glands for following size of PVC Insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required.4 C x 70 sq mm(38 mm)
600 mm X 600 mm X 6 mm thick G.I. plate for fixing of gland and making of 31 mm or 38 mm dia hole by drilling or welding as required for Generator and Tower light pannels.
Removing previously connected cables from over head line, Generetor panel and cleaning cable to be suitable for Glanding and Termination and again Connecting the cable in proper sequence with Proper fixing of Gl plate in proper hole of 31 mm or 38 mm dia.
Providing of 70 sq mm 4 core isi marked, upto 1.1 kv grade Alluminium armouredcable for changing of service cable where ever required.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of size not exceeding 35 to 95 sqmm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. As required
Providing of 35 sq mm 4 core isi marked, upto 1.1 kv grade Alluminium armouredcable for changing of service cable where ever required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of size upto 35 sqmm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. As required
Earthing with copper earth plate 600 mm X 600mm X 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr. Long etc.with charcoal/coke and salt as required For tubular pole installed in weighbriages wherever required.
Providing and fixing 25mmX5mm Gl.strip on surface or in recess for connections etc. as required.
Total impact of GST for the purpose of CTC
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid