| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.0 LAccepted-AOC | ₹12.0 L Quoted ₹14.8 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹19.1 LRejected-Finance 146 B SICOP BIRPUR INDUSTRIAL AREA BARI BRAHMANA JAMMU 181133 J K | BARI BRAHMANA | JAMMU | JAMMU AND KASHMIR | 181133 | ₹19.1 L | L2 | Rejected-Finance OTHER THAN L1 |
| 3 | L3₹23.1 LRejected-Finance | ₹23.1 L | L3 | Rejected-Finance OTHER THAN L1 |
| 4 | Rejected-Technical | - | - | Rejected-Technical No in WLR of QE Sep 25 of HQ CENC letter No 42594/WLR/A to D/455/E8 dt 31 Jan 26 |
| 5 | Rejected-Technical R O NAUSHERA DISTT RAJOURI J K 185151 | NAUSHERA | RAJOURI | JAMMU AND KASHMIR | 185151 | - | - | Rejected-Technical Rejected due to not having b(ii) category in enlistment letter |
| Sl No | Description | Qty | Unit | ASIA ENTERPRISES L3 | jaima electricals L2 | M/S JIWAN SINGH L1 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully of transformer capacity 50 KVA to 100 KVA from four pole and two pole structure, platform by disconnecting all the electrical connection and transporting the same to authorised workshop including draining out of the transformer oil in clean barrels, opening the top cover, taking out of the defective/burnt out HT/LT coils out of the tank for repair, insulation testing of the transformer winding ,refilling the transformer oil after checking proper dielectric strength, refitting the top cover and other accessories including painting of the transformer with approved colour with synthetic enamel paint, all as specified and directed and transporting the transformer back on original place for installation and securing properly on four/two pole/platform and making all HT/LT connection to the complete satisfaction of Engr-in-charge. | 14 | Each job | 10,000 ₹1.4 L | 10,000 ₹1.4 L | 2,000 ₹28,000 |
| 2.00 | Ditto all as per Srl item No 01 here-in-above but exceeding transformer capacity 150 KVA and upto 200 KVA
Note for Srl Item No 1 and 2 :-
(a) The rates are inclusive of transportation of transformer from site of installation to authorised workshop and back including T&P required for loading/ unloading and all the HT/LT winding shall be measured and paid separetly.
(b) Standby transformer shall be arranged by contractor at their own cost to avoid failure of supply on site and the capacity of transformer should be matched with repaired transformer.Penalty charges @1000/day shall be deducted on failure of arrangement of standby transformer.
(c) Contractor has to submit the list of authorized workshops for full satisfaction of Engr-in charge and final binding shall remain with the Engr -in-charge. | 2 | Each job | 10,000 ₹20,000 | 10,000 ₹20,000 | 2,500 ₹5,000 |
| 3.00 | Replacement of burnt defective LT copper coil of transformer capacity 50 KVA to 100 KVA with new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impedence and insulation all as specified and directed by Engr-in-Charge | 300 | Kg | 1,200 ₹3.6 L | 1,000 ₹3 L | 902 ₹2.7 L |
| 4.00 | Ditto all as per Srl item No 3 above but of transformer capacity exceeding 150 KVA and upto 200 KVA.
Note for srl item No 3 & 4 :-
The cost of coil shall be inclusive of cost of varnish insulating paper and other insulating materials and no extra payment will be made for the same. | 180 | Kg | 1,200 ₹2.2 L | 1,000 ₹1.8 L | 902 ₹1.6 L |
| 5.00 | Replacement of burnt defective HT copper coil of transformer capacity 50 KVA to 100 KVA with new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impedence and insulation all as specified and directed by Engr-in-Charge | 300 | Kg | 1,200 ₹3.6 L | 1,000 ₹3 L | 902 ₹2.7 L |
| 6.00 | Ditto all as per Srl item No 5 above but of transformer capacity exceeding 150 KVA and upto 200 KVA.
Note for srl item No 5 & 6 :-
The cost of coil shall be inclusive of cost of varnish insulating paper and other insulating materials and no extra payment will be made for the same. | 180 | Kg | 1,200 ₹2.2 L | 1,000 ₹1.8 L | 902 ₹1.6 L |
| 7.00 | Filtration, heating and dehydration of transformer oil on site by using filteration machine and EHV grade having dielectric strength not less than 55 KV with 2mm gap inluding removal of all moisture,dirt/girth all as specified and directed by Engr-in-charge.
Note:-Filtration, heating and dehydration of transformer oil shall be carried out on site and rate quoted by contractor shall deemed to include for arrangement of filtration machine and its transportation to various locations of installation of transformer and topping of oil. | 2,500 | Ltr | 40 ₹1 L | 15 ₹37,500 | 30 ₹75,000 |
| 8.00 | HT bushing assembly with brass nut, stud, washers and insulators suitable for outdoor type transformer capacity of 50 KVA to 200 KVA, complete all as specified and directed. | 30 | Each job | 4,000 ₹1.2 L | 2,500 ₹75,000 | 750 ₹22,500 |
| 9.00 | LT bushing assembly with brass nut, stud, washers and insulators suitable for outdoor type transformer capacity of 50 KVA to 200 KVA, complete all as specified and directed. | 30 | Each job | 4,500 ₹1.4 L | 3,000 ₹90,000 | 350 ₹10,500 |
| 10.00 | Construction in replacement of transformer platform size 3mx2mx1m from ground and 0.5 mtr below ground level with brick construction in wall and steps, XPM fencing upto 1.5 mtr height with angle iron post 50 x50x6mm including gate with locking arrangement min weight 60 Kgs, 100mm PCC 1:5:10 type E-2 in foundation, 0.23 mtr thick brick work in CM 1:4, 10 mm thick rendering in CM 1:4 to walls, 50 mm thick PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) in flooring over 100 mm thick sub base in PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) laid over rammed earth, 40 mm thick PCC on steps, painting to fencing with two coats of synthetic enemled paint over a coat of red oxide primer, complete all as specified and directed. | 2 | Each job | 50,000 ₹1 L | 80,000 ₹1.6 L | 40,000 ₹80,000 |
Updated dates
Tender Value
₹23.5 L
EMD Value
₹47,000
Closing Date
24 Jan 2026, 6:00 pmClosed
Anurag Anand DCWE
HQ 135 WKS ENGRS PIN 914135 C/O 56 APO
REPAIR/ MAINT OF TRANSFORMER, VOLTAGE STABLIZER, PAINTING WORKS AND CONNECTED ITEMS AT SUNDERBANI UNDER GE NORTH AKHNOOR.
2025_MES_746168_1
CWE/JA-29/2025-26
Open Tender
Electrical and Maintenance Works
180 days
AKHNOOR
AD PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE NORTH AKHNOOR
₹47,000
Yes
28 Mar 2026
26 Dec 2025
26 Jan 2026
26 Dec 2025
24 Jan 2026
10 Jan 2026
Taking down carefully of transformer capacity 50 KVA to 100 KVA from four pole and two pole structure, platform by disconnecting all the electrical connection and transporting the same to authorised workshop including draining out of the transformer oil in clean barrels, opening the top cover, taking out of the defective/burnt out HT/LT coils out of the tank for repair, insulation testing of the transformer winding ,refilling the transformer oil after checking proper dielectric strength, refitting the top cover and other accessories including painting of the transformer with approved colour with synthetic enamel paint, all as specified and directed and transporting the transformer back on original place for installation and securing properly on four/two pole/platform and making all HT/LT connection to the complete satisfaction of Engr-in-charge.
Ditto all as per Srl item No 01 here-in-above but exceeding transformer capacity 150 KVA and upto 200 KVA Note for Srl Item No 1 and 2 :- (a) The rates are inclusive of transportation of transformer from site of installation to authorised workshop and back including T&P required for loading/ unloading and all the HT/LT winding shall be measured and paid separetly. (b) Standby transformer shall be arranged by contractor at their own cost to avoid failure of supply on site and the capacity of transformer should be matched with repaired transformer.Penalty charges @1000/day shall be deducted on failure of arrangement of standby transformer. (c) Contractor has to submit the list of authorized workshops for full satisfaction of Engr-in charge and final binding shall remain with the Engr -in-charge.
Replacement of burnt defective LT copper coil of transformer capacity 50 KVA to 100 KVA with new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impedence and insulation all as specified and directed by Engr-in-Charge
Ditto all as per Srl item No 3 above but of transformer capacity exceeding 150 KVA and upto 200 KVA. Note for srl item No 3 & 4 :- The cost of coil shall be inclusive of cost of varnish insulating paper and other insulating materials and no extra payment will be made for the same.
Replacement of burnt defective HT copper coil of transformer capacity 50 KVA to 100 KVA with new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impedence and insulation all as specified and directed by Engr-in-Charge
Ditto all as per Srl item No 5 above but of transformer capacity exceeding 150 KVA and upto 200 KVA. Note for srl item No 5 & 6 :- The cost of coil shall be inclusive of cost of varnish insulating paper and other insulating materials and no extra payment will be made for the same.
Filtration, heating and dehydration of transformer oil on site by using filteration machine and EHV grade having dielectric strength not less than 55 KV with 2mm gap inluding removal of all moisture,dirt/girth all as specified and directed by Engr-in-charge. Note:-Filtration, heating and dehydration of transformer oil shall be carried out on site and rate quoted by contractor shall deemed to include for arrangement of filtration machine and its transportation to various locations of installation of transformer and topping of oil.
HT bushing assembly with brass nut, stud, washers and insulators suitable for outdoor type transformer capacity of 50 KVA to 200 KVA, complete all as specified and directed.
LT bushing assembly with brass nut, stud, washers and insulators suitable for outdoor type transformer capacity of 50 KVA to 200 KVA, complete all as specified and directed.
Construction in replacement of transformer platform size 3mx2mx1m from ground and 0.5 mtr below ground level with brick construction in wall and steps, XPM fencing upto 1.5 mtr height with angle iron post 50 x50x6mm including gate with locking arrangement min weight 60 Kgs, 100mm PCC 1:5:10 type E-2 in foundation, 0.23 mtr thick brick work in CM 1:4, 10 mm thick rendering in CM 1:4 to walls, 50 mm thick PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) in flooring over 100 mm thick sub base in PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) laid over rammed earth, 40 mm thick PCC on steps, painting to fencing with two coats of synthetic enemled paint over a coat of red oxide primer, complete all as specified and directed.
Supply and filling Transformer oil of dielectric strength not less than 40KV with 4mm gap of discharge 2 sec for topping up of transformer complete all as specified and directed.
Supply and fixing aluminium strip of size 25x 3.15 mm to be fixed on wall or to be laid in ground complete all as specified and directed.
Disconnecting input/output supply from voltage stabilizer of capacity up to 100 KVA any type oil/air cooled and dismantling the same for repair checking/testing all component complete repairing for efficient functioning checking/tightening of all connections resetting/recalibration of all PCB’s ,servo motors, voltmeter, cleaning of tapping, joints of dimmer stat including replacement of minor parts like screws bolts gear of servo motor carbon brushes button and other minor parts etc all as directed by Engr-in-charge.
Supply only servo motor 3 Kg torque of make of existing motor
Supply only servo motor 10 Kg torque of make of existing motor
Supply only servo motor 20 Kg torque of make of existing motor
Supply only servo motor 40 Kg torque of make of existing motor
Supply only dimmerstate for 30 KVA unbalanced servo stabilizer
Supply only dimmerstate for 25 KVA unbalanced servo stabilizer
Supply only dimmerstate for 15 KVA unbalanced servo stabilizer
Supply only RC network for 10Kg servo motor
Supply only RC network for 3 Kg servo motor
Supply only RC network for 20Kg servo motor
Supply only RC network for 40 Kg servo motor
Supply only PCB control Cards for Servo voltage stabilizer upto 100 KVA
Supply only PCB control Cards for Servo voltage stabilizer above 100 KVA to 200 KVA
Supply only Trigger transformer for up to 100 KVA for balanced type voltage stablizer
Supply only Trigger transformer rom for above100 KVA to 200 KVA for balanced type voltage stablizer
Supply only rotary switch for RYB phases
Supply only Drive assembly for voltage stabilzer upto 100 KVA per phase
Supply only Drive assembly for voltage stabilzer above 100 KVA to 200 KVA per phase
Supply only PCB holder for balanced type voltage stabilizer upto 100 KVA
Supply only PCB holder for balanced type voltage stabilizer above 100 KVA to 200 KVA
Note:- Deduction for Schedule of credit (Sch 'A' Part-II) to be made of ₹ 278566.00 from the total quoted amount of BOQ while accepting the bid. Details of schedule of credit is given in tender documents.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
TENDER29.pdf
Tender Documents • 0.93 MB
BOQ_835513.xls
BOQ • 2.02 MB
Download all tender documents and submit your bid