Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.6 LQualified Make: Koel Green Electro
Model: KOEL GREEN KG1-25WS WITH PART NO. 318181-3212 20 23 BHAGWANPUR RAIPUR SAHKARI AUDYOGIC KSHETRA HARIDWAR UTTARAKHAND 247661 | HARIDWAR | UTTARAKHAND | 247661 | Make: Koel Green Electro
Model: KOEL GREEN KG1-25WS WITH PART NO. 318181-3212 | L1 | Qualified | |
| 2 | L2₹5.8 L+₹1.3 L (27.8%)Qualified Make: Mahindra Powerol-Perfect
Model: Mahindra 3335 TCI GM C2 GANDHI NAGAR DELHI DELHI 110031 | SHAHDARA | DELHI | 110031 | Make: Mahindra Powerol-Perfect
Model: Mahindra 3335 TCI GM C2 | L2 | Qualified | |
| 3 | Disqualified Make: KOHLER
Model: KOHLER-KDG0025P1 | Make: KOHLER
Model: KOHLER-KDG0025P1 | - | Disqualified | |
| 4 | Disqualified Make: Greaves Power
Model: Escorts Limited,G25-II PANDURANG SHASTRIATHAVALE AHMEDABAD GUJARAT 380015 | AHMADABAD | GUJARAT | 380015 | Make: Greaves Power
Model: Escorts Limited,G25-II | - | Disqualified | |
| 5 | Disqualified Make: Sonalika
Model: SONALIKA-JAYCO & 25KVASP-AMF-INCT | Make: Sonalika
Model: SONALIKA-JAYCO & 25KVASP-AMF-INCT | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
26 Jun 2018, 3:00 pmClosed
diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 25 3.5
5
7.5
10
15
20
25
3 0
40
62.5
82.5
100
125
160
180
200
250
320
380
400
500
600
750
5 0
140 No of Phase - Single phase
Three Phase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine false - BIS license No
if applicable - - Type of Engine cooling Liquid Cooled Air Cooled
Liquid Cooled Type of governer Mechanical Mechanical
Electronic Class of governer A2 A0
A1
A2 Number of cylinders (nos) 3 - No of Strokes (nos) 4 - 1/4 Rated RPM of Engine (RPM) - 1500
3000 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 - Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 12 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 25 - Power Factor of AC generator 0.8 - Efficiency at rated Power factor at 75% of full Load 85 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 3 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel AMF Manual
AMF IP Rating of Control Panel IP 53 - ACOUSTIC ENCLOSURE Sheet Thickness 1.2 1.6
1.8
2
1.2 Thickness of Foam 25 - Density of Foam for sound insulation 32 - Noise level at 1 meter (dB) 75 - BATTERY Battery Type & Specification Normal lead acid to IS: 7372 for motor vehicles - Battery capacity (Ah) - - No of batteries 1 - TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes - 2/4 Test Report number and date(Engine) - - Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986
in respect of noise and emission norms
as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Installation & Commissioning With Installation With Installation
Without Installation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Rakesh Kumar 221007
ARCHAEOLOGICAL SURVEY OF INDIA 1 15 EMD Required No ePBG Required No
181934
GEM/2018/B/25923
diesel generators- DG Sets
15 days
Uttar Pradesh; Varanasi
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 25 3.5 | - | - | - |
| 5 | - | - | - |
| 7.5 | - | - | - |
| 10 | - | - | - |
| 15 | - | - | - |
| 20 | - | - | - |
| 25 | - | - | - |
| 3 0 | - | - | - |
| 40 | - | - | - |
| 62.5 | - | - | - |
| 82.5 | - | - | - |
| 100 | - | - | - |
| 125 | - | - | - |
| 160 | - | - | - |
| 180 | - | - | - |
| 200 | - | - | - |
| 250 | - | - | - |
| 320 | - | - | - |
| 380 | - | - | - |
| 400 | - | - | - |
| 500 | - | - | - |
| 600 | - | - | - |
| 750 | - | - | - |
| 5 0 | - | - | - |
| 140 No of Phase - Single phase | - | - | - |
| Three Phase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine false - BIS license No | - | - | - |
| if applicable - - Type of Engine cooling Liquid Cooled Air Cooled | - | - | - |
| Liquid Cooled Type of governer Mechanical Mechanical | - | - | - |
| Electronic Class of governer A2 A0 | - | - | - |
| A1 | - | - | - |
| A2 Number of cylinders (nos) 3 - No of Strokes (nos) 4 - 1/4 Rated RPM of Engine (RPM) - 1500 | - | - | - |
| 3000 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 - Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 12 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 25 - Power Factor of AC generator 0.8 - Efficiency at rated Power factor at 75% of full Load 85 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 3 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel AMF Manual | - | - | - |
| AMF IP Rating of Control Panel IP 53 - ACOUSTIC ENCLOSURE Sheet Thickness 1.2 1.6 | - | - | - |
| 1.8 | - | - | - |
| 2 | - | - | - |
| 1.2 Thickness of Foam 25 - Density of Foam for sound insulation 32 - Noise level at 1 meter (dB) 75 - BATTERY Battery Type & Specification Normal lead acid to IS: 7372 for motor vehicles - Battery capacity (Ah) - - No of batteries 1 - TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes - 2/4 Test Report number and date(Engine) - - Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986 | - | - | - |
| in respect of noise and emission norms | - | - | - |
| as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Installation & Commissioning With Installation With Installation | - | - | - |
| Without Installation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Rakesh Kumar 221007 | - | - | - |
| ARCHAEOLOGICAL SURVEY OF INDIA 1 15 EMD Required No ePBG Required No | - | - | - |
Exempted
26 Jun 2018
7 Jun 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_181934.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .