Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹10.5 L+₹1.1 L (11.2%)Rejected-Finance | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹10.6 L+₹1.1 L (11.8%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | L3 | Rejected-Finance Not the lowest tenderer | |
| 4 | L4₹11.8 L+₹2.3 L (24.4%)Rejected-Finance | L4 | Rejected-Finance Not the lowest tenderer | |
| 5 | L5₹12.4 L+₹2.9 L (30.9%)Rejected-Finance | L5 | Rejected-Finance Not the lowest tenderer |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
14 Jul 2020, 6:00 pmClosed
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
REPAIR/ REPLACEMENT OF UNSERVICEABLE LT PANELS FEEDER PILLER BOX AND LT UNDERGROUND CABLES AT MANESAR KHANPUR AND DUNDAHERA ARMY CAMP UNDER AGE EM (S) OF GE (SOUTH) DELHI CANTT-10
2020_MES_355106_1
GE/DS-12/2020-21
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹38,000
Yes
27 Aug 2020
23 Jun 2020
16 Jul 2020
23 Jun 2020
14 Jul 2020
7 Jul 2020
24 Jun 2020 - 4 Jul 2020
Amount
Supply and laying XLPE insulated armoured (heavy duty) electric cable with aluminium stranded conductor 1100 volts grade of following size including taking down with jointing kit complete all as specified and directed by Engineer-in-charge as follows :
25 Sqmm x 2 Core
35 sqmm x 3.5 core
70 Sqmm x 3.5 Core
95 Sqmm x 3.5 Core
120 Sqmm X 3.5 Core
300 Sqmm x 3.5 Core
Excavation, in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr in depth for laying cabel/GI Pipe and getting out old bricks in soft/ loose soil and getting out complete all as specified and directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick complete all as specified and directed by Engineer-in-charge.
Removal of surplus excavated material to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge.
M&L Sand cushioning to under ground cable with dry sand locally available 8cm thick before laying the cable and 15 cm above the cable, stretching and testing of cable complete all as specified and directed by Engineer-in-charge. Note:- Payment purpose punned thickness shall be measured 18 CM.
Supply and laying sub class ‘B’ bricks well burnt for cable protections laid flat with length equal to width of brick over cable perpendicular to length of cable complete all as specified and directed by Engineer-in-charge.
S&F for cable jointing kit for 11 KV (Earthed) grade for outdoor termination end joint kit, heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed by Engineer-in-charge.
S&F for cable jointing kit for 11 KV (Earthed) grade for indoor termination end joint kit heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed by Engineer-in-charge.
S&F for cable jointing kit for 11 KV (Earthed) grade for straight through, heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed by Engineer-in-charge.
S&F for Heat Shrinkable 1100 V XLPE Straight Joints cable jointing kit for the following size complete all as specified and directed by Engineer-in-charge as follows :
25 sqmm to 50 sqmm size
70 sqmm to 150 sqmm size
185 sqmm to 300 sqmm size
S&F in replacement of moulded case circuit breaker (MCCB) four pole 630 Amps 50 KA capacity 415V 50Hz with adjustable thermal and magnetic relay & lugs etc complete all as specified and directed by Engineer-in-charge. (Make of MCCB's Legrand/Havells/L&T/C&S)
All as per item No 14 here-in-before but 400 Amps 4 pole 36 KA Capacity 415V 50 Hz.
All as per item No 14 here-in-before but 320 Amps 4 pole 50 KA Capacity 415V 50 Hz.
All as per item No 14 here-in-before but 250 Amps 4 pole 36 KA Capacity 415V 50 Hz.
All as per item No 14 here-in-before but 250 Amps 3 pole 36 KA Capacity 415V 50 Hz.
All as per item No 14 here-in-before but 200 Amps 4 pole 36 KA Capacity 415V 50 Hz.
All as per item No 14 here-in-before but 200 Amps 3 pole 36 KA Capacity 415V 50 Hz.
All as per item No 14 here-in-before but 160 Amps 3 pole 36 KA Capacity 415V 50 Hz.
All as per item No 14 here-in-before but 100 Amps 3 pole 16 KA Capacity 415V 50 Hz.
Laying only brick for cable protection laid flate with length equal to width of brick over cable
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
aggarwal engineers contractors
verma enterprises
M/s S.G. BUILDERS
Surjit and Sons
PRASAD ELECTRICALS
M/S ASHISH AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .