Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.5 LAccepted-AOC BHAIRAVNATH NAGAR AT KUSGAON POST LONAVLA 410 401 DISTT PUNE | PUNE | MAHARASHTRA | 410401 | L1 | Accepted-AOC lowest tenderer | |
| 2 | L2₹37.4 L+₹15,984.60 (0.43%)Rejected-Finance SHOP NO 04 AKBAR ARCADE NEAR INDRAYANI BRIDGE LONAVLA PUNE 410401 | PUNE | MAHARASHTRA | 410401 | L2 | Rejected-Finance GREATER THAN L1 | |
| 3 | L3₹44.0 L+₹6.7 L (18.1%)Rejected-Finance 503 GIRIRAJ HEIGHT VAITY WADI L B S MARG NEAR HARINIWAS CIRCLE THANE 400 602 | THANE | MAHARASHTRA | 400602 | L3 | Rejected-Finance GREATER THAN L1 |
Tender Value
₹36.9 L
EMD Value
₹74,000
Closing Date
2 Apr 2024, 6:00 pmClosed
Shri Gaurav Tiwari, IDSE, EE
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
PROVN OF KITCHEN CABINET IN ALL OMQ / SMQS AND DEFICIENT EXHAUST FANS, STANBY POWER SUPPLY (WITH UPS AND SERVER ROOM) FOR CCTV SYSTEM, TEMPORARY PARKING SHED WITH HARD STANDING NEAR BLDG NO P-87, SPL REPAIRS TO CERTAIN BLDG (EM WORKS) AT AIR FORCE ST
2024_MES_645324_1
GE/LONAVLA/8221/E8
Open Tender
Civil Works
Item Rate
210 days
GE (I) (NAVY) LONAVLA
As per NIT /Tender documents
6 documents required · 6 mandatory
₹500
Yes
GEINDEPNAVYLONAVLA
₹74,000
Yes
18 May 2024
6 Mar 2024
4 Apr 2024
6 Mar 2024
2 Apr 2024
20 Mar 2024
6 Mar 2024 - 19 Mar 2024
Amount
Surface excavation n exc 30 Cm deep and averaging 15 Cm deep and getting out in hard dense soil.
Removing of excavated materials / debris depositing out side of the defence land
Excavating post holes or similar holes, each not exceeding 0.50 Cu. M, getting out in Hard/ Dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 100m & making good surface complete all as specified and directed.
M&L Plain Cement Concrete Type C2 1:3:6(using 20 mm graded granite stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
Supply and fix for steel work in tubular/ squre/rectangular trusses including special shaped washer etc., complete using ERW or induction butt welded tubes conforming to IS.1161-1998 grade st-240 (medium grade) complete all as specified and as directed by Engr-in-charge.
S&F Plates (plain or chequered ) channels , square cut or notched (ordinary and counter sunk) forming holes, without any attachement & complete all as specified
S&F wind ties for roof including securing bolts including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 etc complete all as specified and directed.
S&F for Pre- Painted galvatume aluminium zinc coating GI based corrugated steel sheet,plain sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and directed.
M&L Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
M&L for hardcore of broken stone or boulders of gauge not exc. 63 mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 100 mm thick cement concrete type D-2, 1:4:8 (40mm graded stone aggregate) as in sub base, flooring etc complete all as spd and directed.
M& L for 80mm thick Machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 ,M-40 grade laid over sand cushioning after consolidation set and level with grey cement and pigment and including 75mm thick sand cushion filing under floors including consolidation complete all specified as directed.
M&L for 12mm thick veneered decorative plywood, grade1 (with BWR resin) with decorative face veneers on both faces fixed with screws and adhesive to timber frame work alongwith necessary SS beading complete all as specified and directed.
S&F for SS two track channel suitable for 5mm thick sliding glass shutter fixed in timber framed work with self driving screw for cupboard shutter frame complete all as specified and directed.
S&F Stainless steel beading L/U shape or exc 15mm wide each side fixed in timber framed work with self driving screw for cupboard complete all as specified and directed.
S&F only SS roller suitable for 5mm thick sliding glass shutter for cupboard glass shutter complete all as specified and directed.
S&F only Sheet glass, ordinary quality 5mm thick plain/tinted in square exc 0.5 sq. m in each pane complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide, & n exc 1.5m deep and getting out in hard/dense soil.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth; for foundation and getting out in hard rock compete all as specified.
Returning filling in, including, spreading levelling watering and well ramming in layers not exc 25cm in soft/loose soil etc complete.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation and mass concrete.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
M & L for RCC M30 (Nominal mix) for foundation beams, plinth beams, bases for columns etc basement slabs, under reamed piles and mass concrete.
M&L for RCC M30 (Nominal Mix) for roof beam supported on walls, beams and lintel above 1.5 m clear span complete all as specified
M&L for RCC M30 (Nominal Mix) for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like complete all as specified .
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) complete all as specified.
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for coloumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips on slab, MH cover etc. complete all as specified and directed by Engineer-in-charge.
All as per ser item 27 here-in-after but bars of 8 mm dia complete all as specified.
Demolition of brick work/stone masonry built in cement mortar including all quoins arches, pillars all as directed.
M&L for pre-cast cement concrete block Type B1 1:2:4 masonary with solid blocks, exc. 10 cm in width and setting in CM 1:4 complete all as specified and as directed.
M&L rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:6 complete all as specified
M&L rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces with WPC 3% complete all as specified and directed.
M&L for rendering 5mm thick to celing concrete surfaces in CM 1:3 complete all as specified and directed.
Supply only for Integral waterproofing compound complete all as specified and directed.
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 25 cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
M&L for 75 mm thick PCC (1:3:6) type C 2 (usin 20 mm gradded stone aggregate) as in plinth protection complete all as specified and directed.
M & L for preparation of new plastered surfaces of walls and applying two coat of oil bound distemper including application of white cement based wall care putty finish (3mm thick) for smooth finish.etc complete all as specified and directed.
M&L for preparation of new plastered surfaces on ceiling and applying three coat of white wash etc complete all as specified and directed
M/L for rendering 10mm thick in cm 1:4 on concrete,wall, roof and chajja surface finished even and smooth without using extra cement to get a uniform level surface for laying of membrane treatment complete all as specified and directed..
M/L for applying oil based bituminous primer @ 0.10 Kg/Sqm providing and laying 4mm thick. APP modified water proofing membrane weighing not less than 4kg/sqm re-inforced with non woven polyester matt weighing not less than 160 gm/sqm having softening point not less than 140 degree centigrade longitudinal tensile strength not less than 650 N/Sqm, tearing strength of 180N and with thermal insulation with the mineral / graved finish on upper side and laying with torches application and with 10 cm minimum lap in both direction length wise and width wise all as specified and directed by Engr-in-charge.
M&L for Screed bed or bedding layer of mortar 20 mm thick for laying floor finishes in CM 1:6 etc: complete all as specified and directed.
M&L for Rendering 10 mm thk in CM (1:4) as in backing coat of cement plaster for laying of wall tiles etc: complete all as specified and directed.
M/L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqm in floors/vertical surfaces etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed in CM 1:6 laying floor finishesed complete all as specified and directed.
M&L for preparation of old decorated painted surfaces of walls by applying two coat of acrylic based distemper emulsion of any tint/shade including a coat of wall care putty to get a even and smooth surfaces of walls complete all as specified and directed.
Taking down existing doors/windows/ventilators (without taking off shutters and guard bars) of exe 1.5 sqm & n. exc 4 sqm etc complete all as specified and as directed incl stacking the materials properly.
S&F for factory made Solid PVC door frame of size 50mm x 47 mm made out of prelaminated wood grain PVC solid core reinforced with MS square tube, supplying & fixing in opening as per spcification & drawing etc, complete all as specified and as directed.
S&F for 35 mm Factory made Moulded door shutter(Wood grain) consisting of solid core single leaf flush door of 30 mm thickness,lipped with 15 mm (5mm x 3) thick x30 mm width on the other stiles & bottom rails & 10mm (5mm x 2) thick x 30 mm width on other stiles & bottom rails , The inner panel laminated with 2 mm thick termite proof, water proof and fire resistant molded PVC sheet with 2,4,6 raised panel designs in different plain and / or prelam colours after routing the Moulded design on one side & 2 mm plain and / or prelam PVC sheet on other side using rubber adhesive on flush door & solvent cement adhesive on the PVC Lipping and manufacturer's specification & drawing etc, complete all as specified and directed.
S&F Butt hinges,125mm stainless steel, with stainless steel hinge pin complete all as specified and directed..
S&F aluminium handles cast type anodised 150mm sizecomplete all as specified and directed.
S&F aluminium anodised barrel tower bolts of extruded section and fixed 200 mm sizecomplete all as specified and directed.
S&F aluminium alloy anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of sextruded sections or cast aluminium alloy and fixed 300mm length.
Supply installation, Testing & Commissioning of ECO friendly Diesel Engine driven generating set of 15 KVA CPCB-II nearest higher side 400/440 volts, AC 3 phase, 50 HZ , 4 wire, 0.8 PF directly coupled alternator and engine liquid cooled with AMF Panel and other accessories comprising of following : A) ENGINE- Diesel engine, liquid cooled, turbocharged with after cooler, Vertical , electric start, compression ignition, 4 stroke, designed to run continuously at 1500 RPM confirming to IS 10002, ISO-3046, BS 5514 standard with an overload capacity of 10 % for one hour in every 12 hrs. operation. Diesel Engine will comply with present CPCB norms. The diesel engine will comprise of following: - i) Radiator with Fan , ii) 12 V Electric starting system ,iii) Mico pump., iv) Battery charging alternator ., v) Dry type air cleaner ., vi) K-Cool Super plus coolant . , vii) Exhaust Silencer., viii) Fuel Oil filter (Spin on type ). , ix) Lubricantion oil filter (Spin on type) , x)First fill of Lube oil , xi) Centrifugal by-pass filter., xii) In- line Monoblock fuel pump with mechanical governer and fuel pump. , xiii) Front & rear engine mounting supports. , xiv) Engine control panel consisting of OFF/ON/START keys lub oil pressure gauge, Ammeter, electronic Hour meter, speedometer. , xv) Safety against low lub oil pressure. , xvi) Engine operation/Maintenance, spare parts Manual., xvii) Engine test certificate. B) ALTERNATOR - Alternator, suitable for continuous operation rated at 1500 rpm 415 V, 0.8 PF, 50Hz, 3 Ph. in SPDP enclosure, self- excited & self- regulated, Brush less, floor mounted with Ball or Bearings on end shields. The alternator conforms to IS: 4722, BS EN 60034-1 & will be suitable for tropical condition. C) BASE FRAME: -Suitable to couple above Engine & Alternator made from steel sheet metal. D) FUEL TANK : - 8 Hrs Capacity, with Inlet & Outlet arrangement, air vent & drain plug arrangement. E) BATTERIES: - 1 No.12 V batteries with Leads and Battery Cable F) STANDARD GENSET CONTROL PANEL WITH CONTROLLER UNIT :- 1. 1 No. MCCB of Suitable capacity 2. Control Switch 3. Genset controller unit ‘KG 645’ with totally enclosed, steel construction control panel suitable for indoor floor / wall mounting installation having following safeties and display parameters: - G) AMF CONTROL PANEL -The panel shall be made out of fabricated sheet steel suitable for indoor floor mounting installation hinged from panel door for easy accessibility and suitable rated bus bar internal wiring fuses with suitable provision for connection incoming/out going leads complete. H) Acoustic enclosure - Supply & install of Acoustic Enclosure suitable for 25 KVA DG set as under., i) Fabricated out of CRCA sheet of suitable thickness as per manufacture design. Polyster based powder coated internaly and externaly with lockable type door handle. All nuts and handles shall be zinc coated. , ii) The doors are gasketed with EPDM gaskets., iii) Sound proofing with high quality rock wool/mineral wool confirming to IS 8183 of 50mm thickness and density at 96 Kg /M3 coverd with fiber glass cloth and perforated powder coats sheet specialy designed allenuators (Sound controller) at air entry and exit of the container noice level shall be not exceed 75 Db at 1 meter distance as per CPCB norms. , iv) Adequate ventilation to meet air requirement for combustion and heat removal with provn of a blower. , v) Emergency stop push button out side the container., vi) Provn of light inside the canopy providing of FTL fitting 1x20 watt with wiring and control switch. (Location-air force)
M & L for DG Set TRIANGLE Shed,Plinth 3 x 3 x .5 mtr, shed 3 x 3 x 3.3 mtr, made up of steel work in tubular trusses square section size (50x50x3)mm including, special shaped washer etc. complete unsing ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St-240, pre-painted galvaturme aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in wall, fixed with self tapping screws as specified and as directed by Engineer-In - Charge.
Supply and installation of Earthing rods as per following specifications (a) Earthing rod 25mm pure copper hollow Earthing Rod with strip I pipe Design Length 3m. Copper Terminal of 100x50x5 (b) BFC Compound The BFC is carbide based having very high electrical conductivity. BFC having high moisture retaining capacity BFC is hygroscopic, nonmagnetic and non - corrosive in nature and in ROHS compliant (c ) Installation The Earthing electrode will be placed in the ground after a bore is drilled to the depth of 3.5m The Bore drilling will be done with the help of pneumatic boring machine. 50KG BFC will be placed in the bore to cover the Earthing rod from all sides. BFC will be poured in slurry form in properly mixed condition Earth pit cover square 300x300x240mm to be provided to cover the Earth pit. The Earth pit cover shall be made of Reinforced FRP and should be capable of carrying The weight of 5 tones. Make : U-Protect,Ashok,JEFF Techno. Note : Electrode must be tested for short crcuit test of minimum 40ka at CPRI/NABL 2) After installation company testing & checked test with earth value certificate provide by contractor.
Excavatioin in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and taking out soft/loose soil for laying of cable /erection of pole/stay pit excavation
M&L for crushed stone sand for cable cushoining laid in trenches for protection of cable
Supply and laying factory cast, unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm laid in trenches as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core.Including taking down old unserviceable cable any size by dismantling of all electrical connection etc all as diercted NOTE: All Cable properly secured by saddle as per cable size with long nut and bolts and under GI pipe or under ground as per site requirment all as diercted by Engr in charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25.0 sq mm 4 core. Including taking down old unserviceable cable any size by dismantling of all electrical connection etc all as diercted. NOTE: All Cable properly secured by saddle as per cable size with long nut and bolts and under GI pipe or under ground as per site requirment all as diercted by Engr in charge.
S & F Outdoor Type, weather and vermin proof Bus bar panel made out of 2 mm thick stainless steel sheet with front opening and locking arrangement, 200 Amps capacity aluminium bus bar for phase, 3 No's and 1 No 200 Amp bus bar for neutral, mounted on epoxy insulator including neccessary copper control wiring, heat shrinkable, RYB coloured sleeves over bus bar for identification, earth shields, circular holes at bottom / top to receive incoming and outgoing cable, cable lugs, cable gland of sizes as required floor mounting angle iron frame made out mild steel angle iron of size 40 x 40 x 6 mm grouted on PCC (1:3:6) upto required height all as specified and as directed by Engr-In-Charge .
S&F LT pannels cubical indoor type weather and vermin proof made out of 2 mm CRCA sheet of suitable size with front and rear opening and locking arrangement epoxy powder coated having colour siemens grey 200 Amps capacity aluminium bus bar for phase 3 Nos and 1 No 200 amps bus bar for neutral mounted on epoxy insulator necessary copper control capacity control wiring heat shrinkable RYB coloured sleaves over bus bar for identification floor mounting angle iron base earth shields circular holes at bottom/top to receive incoming and outgoing cable. cable lugs, cable gland of size as required pannel suitable for the following control/filments sensible for 3 phase 50Hz 415V system complete comprising the following and including necessary PCC/Brick work for mounting of pannel. (a) 4 Nos bus bar high conductivity aluminium alloy strips proper insulated for phase (RYB) with 200 Amps & neutral rating 200 amps and mounting on porcelain support.- 01 Set (b) MCCB 125 Amp 4 pole 36 KA 415 Volt ( Incoming) - 01 No (c) MCCB 63 Amps 16 kA 4 pole -03 Nos (d) LED Indicator lamp RYB -Set of three-01No (e) Digital multifunction meter (V, A, F, PF, KW, KVA) with conected as per load required CT conection Note : CPRI approved report and testing and commisning report submited by contrector.
S&F in repairs SPN Distribution Board, 4 Way ,Double door complete all as specified and as directed. Make havells/legrande/L&T
M&L for sub main wiring drawing through PVC casing and capping with Wiring alongwith earth wire size 2x2.5 sq. mm + 1x2.5 sq. mm earth wire of FRLS is PVC insulated copper conductor, single core cable in surface/recessed as required .Note:- Two run of 2.5 sqmm wire and One run of 2.5 sqmm wire and One run of PVC casing caping will be measured as one running meter.
M & L Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.’25 mtr below normal ground level) with top edge of the plate not less 1.5 mtr below normal ground level using galvanised iron strip 25×4mm as earthing lead by means of suitable size of GI nuts, bolts, check nuts and washers all as specified in electrical plate SSR Part I including necessary .Exc & earth work, providing charcoal and salt dust layers and construction of PCC pit in 1:3:6 using 20 mm size graded stone aggregate, precast RCC 40 mm thick cover in 1:2:4 type B 1 with 12 mm dia steel MS plain bar, lifting handle GI pipe of 50 mm bore for earth lead protection andGI pipe 15 mm dia for watering, with funnel and wire mesh including testing on completion. All as specified and as directed incl dismentling existing unsserviciable earthing .
Taking down carefully unserviceable aluminium/copper point wiring (light, fan, socket or power) including unserviceable light fittings, switch board complete, switch sockets, ceiling roses, pendants, regulators, sockets, etc and removing materials from site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M & L for Point wiring with 1.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including providing PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed. (A) One light point or one fan point or bell point controlled by one switch
One 3 pin socket outlet, 5 Amp independent
One 3 pin socket outlet, 5 Amp on the same board with other switches
One bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sq mm size.
All as per item No.2 here in before but wiring with cables of size 2.5 sqmm for wiring & cables of size 2.5 sqmm both (FRLS) as continuous earth wire for one 15 Amps, 3 pin Switch/Socket outlet on Independent board complete all as specified and directed. (Note : cutting chases & making good of disturbed surfaces shall be measured and paid separately).
S & F switch piano, 5 Amp, single pole, flush type one way 230 volts complete all as specified and as directed.
S & F socket out let, 2 in 1, 3 pin, 5 Amps, 240 volts complete all as specified and directed.
S & F Switch socket combination, 2 in 1, 5 Amps, flush type, 240 volts complete all as specified and directed.
S & F Switch socket combination, 5 in 1, 5/15 Amps, 240 volts, flush type with fuse & neon incator complete all as specified and directed.
S & F Ceiling rose, 3 way PVC insulated body complete all as specified and directed by engineer in charge.
4. Suppy and fixing exhaust fan 300 mm sweep, 900 RPM trans air, with louver shutter 220V, single phase AC including 1.0sqmm copper flexible cable twiested three core alongwith flelxible PVC condiut from ceiling rose to fan testing including cutting holes thruogh cement mortor wall for fixing 300mm sweep exhaust fan grouting the bolts, plastering and making good surface internally and externally wth existing colour. complete all as specified and directed .Make :- Havells (Turboforce Heavy duty Exhaust fan ) Crompton/Bajaj.
M & L for cutting/making hole for fixing of ser item No 8 and making good disturbed surface with existing surface all as specified and directed by Engr-in-charge.
M&L sub main wiring of PVC FRLS insulated unsheathed two single core 4.00sqmm copper multi stranded conductor including one run of single core copper conductor of size 2.5 sqmm as earth wire drawing into PVC conduit on surface complete all as specified and directed.
Supply and fixing LED lights fitting for 1x 36W, 220V,AC with driver, holder including LED tube light connecting up with three core flexiblecopper conductor cable of suitable size from ceiling rose complete.Make: Havells cat no. LUMILINES+S36WLED865SPCWH or equivlent Philips/Bajaj.
Supply and fixing LED lights fitting Rod and Batten for 1x 18W, 220V,AC decorative type with driver, holder including LED tube light connecting up with three core flexiblecopper conductor cable of suitable size from ceiling rose complete.Make: Bajaj(BLRB-DB 118 for Batten and BLRB 18W LED Rod,18W LED) or equivlent Philips/Havells
S/F switch bell push, flush type 5 Amp.
S&F in repairs bell, electronic type AC, 230 Volts single pole.
M&L lamp holder, PVC/ poly carbonate type with black plate suitable for batten fittings.
Supply and fix new adore LED lamp 9 Watt confirming to Cat No LHLDBWH4L8R009 of Havell's or euivalent in Philips / Bajaj
Labour only for taking down and fixing repairs to Ceiling Fan with Fan regulator/Exhaust Fan, any Make & any Sweep Oiling, Greasing , removing all dust with painting and Rewinding of fan by super ennameled copper insulated wire as per existing gauge, varnishing, heating assembling and testing for serviceable condition complete all as directed by Engineer-in-Charge.
S&F in repairs fan regulator electronic step type complete all as directed by EIC at site
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.Make: Crompton or equivlent Bajaj/Philips/Havells
Taking down electric meter of any type and any make single/three phase by dismantling of all electrical connection checked the meter ,and Refixed same Nos of meter on wooden board in metal box of suitable size in same Nos of qtr after repair works completed
S&F in replacemen MCB DB SPN 8 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
S&F in repairs MCB SPN 40 to 63 AMP, 240 Volts 10KA 'C' curve , Complete all as specified and directed.
S&F in repairs MCB SP 5 To 32 AMP, single pole 240 Volts 10KA 'C' curve, Complete all as specified and directed.
Taking down sub main wiring of any size from the ceiling, walls etc and incl making good to disturb surface of wall and match with the existing surface.
M&L for sub main wiring drawing through PVC casing and capping with four runs of single core 6 sq mm and two runs of 6.0 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade all as directed.Note:- Two run of 6 sqmm wire and One run of 6 sqmm wire and One run of PVC casing caping will be measured as one running meter.
S&F in replacement Triple pole and neutral (8 Way) Double door, (VTPN) suitable for and including MCCB 4 pole, 200 amps, 16 KA as incoming (compact) Earth and neutral bus bar of capacity upto 300 amp 8 ways,IP 43 protection , shrouded neutral bar & pan assembly with flexible connecting link in the wall with suitable nut and bolt including matching the existing surface all as specified and directed , Make Havells (DHDLVDOBGSFE08)HSN CODE 8537 or equivalent indoasian/Standered.
Supply and fix in repairs Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of rating upto10/20 Apms
M&L for Concealed point wiring rigid PVC conduits ( concealed ) exclusive of boxes (Junction /terminal ) but incusive of all tees , bends elbow , reducer bell mouth tube and fixing all accessories such as couplers , lock nut , saddle , pipe hooks etc ( from meter box on each floor to DB in individual dwelling unit with PVC FRLS multi strandard copper conductor unsheathed cable of size 1.5 sqmm by using PVC FRLS copper conductor unsheathed cable of size 1.5 sqmm(for earthing connections to common earth dolly/earth lugs in MS sunken box/switch board) drawning in concealed conduits 20/25mm dia with all arrangements & PVC accessories as required to site requirement inlcuding fixing of switch board with new machine brass screw & washers complete all as specified & directed. Note :- 1. Colour code of Phase cable is Red,Yellow and Blue . (2) colour code of Neutral is BLACK. (3) Colour code of Earth wire is GREEN.
Supply and fixing LED light fitting 1x40 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
Supply and fixing Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V
S&F in replacement MCB DB TPN 8 ways double door with 440 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
S&F in repairs MCB TPN 40 To 100 AMP, 415V 10KA 'C' curve, Complete all as specified and directed.
S&F IN REPLACEMENT OFFLOAD CHANGEVER SWITCH AC21 (SIDE HANDLE ) rating 200 Amp FP IN SHEET ENCLOUSER 415V AC ,50HZ Complete all as specified and directed by Engr-in charge . Note:- All existing cable are proper seure with saddle or 'U claimp.
KGN builders
United Engineers and Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .